MS 009 Plumbing Fixtures.pdf

PDF 24 MB Posted

Attached to
Repair Maintenance Shop BLDG 8040
Solicitation number
FA4661-21-R-0001
Issued by

View the file

Other files

File Type Posted
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
12-0053 Addendum Four - New Contractor (11-19-20) v2.doc DOC document
12-0053 Addendum Three - New Contractor (11-9-20).pdf PDF
Solicitation Amendment FA466121R00010001 SF 30.pdf PDF
12-0053 Attachment C - Contractor Pricing Breakdown 11.29.16.xlsx XLSX spreadsheet
MS 004 Staging Plan.pdf PDF
MS 039 HM Doors Frames and Hardware.pdf PDF
MS 026 Cove Base Submittal.pdf PDF
MS 032 Concrete Vapor Barrier.pdf PDF
MS 042A Overhead Coiling Doors.pdf PDF
MS 030 Steel Shop Drawings.pdf PDF
MS 024 MBCI Panel Roof and Color Chart.pdf PDF
MS 037 MBCI and Welding Certifications.pdf PDF
AF Form 3065 Dyess Progress Report 42 Gov.pdf PDF
MS 044 Casework.pdf PDF
MS 079 Radius Bullnose for Doorways.pdf PDF
MS 007 Mech and Plumb Consumables.pdf PDF
MS 027-028 Metal Slat Fencing - Color.pdf PDF
MS 011 Fire Alarm and Mass Notification MS 005a.pdf PDF
MS 025 VCT.pdf PDF
MS 070 Water Meter Specifications.pdf PDF
MS 073 Breakroom Sink Type and Color.pdf PDF
MS 031A Toilet Partions and Accessories.pdf PDF
MS 016 HVAC Controls.pdf PDF
MS 055 South Structural Steel.pdf PDF
MS 006 Mech and Plumb.pdf PDF
MS 008 Abatement Plan.pdf PDF
MS 069 Sidewall Sprinkler Head.pdf PDF
MS 076 Backflow Preventer.pdf PDF
MS 064 Dryvit Backstop Air Barrier.pdf PDF
MS 021 HVAC.pdf PDF
MS 050 Welder Certification.pdf PDF
MS 083 Aerospace Air Shower Substitution.pdf PDF
MS 030 Steel Shop Drawings Page 2.pdf PDF
MS 029 Anchor Rod Shop Drawings and Details.pdf PDF
MS 001 QC Plan.pdf PDF
MS 065 Concrete Test Reports.pdf PDF
MS 020A Electrical Transformer.pdf PDF
MS 041 Toilet Accessories and Fire Ext.pdf PDF
MS 022 Louvers and Color Chart.pdf PDF
MS 035 Geotech Compaction Testing.pdf PDF
MS 078 078A Overhead Doors Warranty.pdf PDF
MS 023 Metal Panels.pdf PDF
MS 047 28 Day Concrete Test Results.pdf PDF
MS 061 Masonry Sealant Substitution.pdf PDF
MS 066 Roof Flashing.pdf PDF
REF 12 0053 PR 42 Thru 09 30 2019.xlsx XLSX spreadsheet
MS 010 Insulation.pdf PDF
MS 067 Steel Building Certifications.pdf PDF
MS 052 CMU Specs and Certs.pdf PDF
Show 40 more

Latest 50 of 163 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

MATERIAL APPROVAL SUBMITTAL

(See Instructions on Reverse)

Form Approved OMB No 9000-0062

Expires May 31, 2005

Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington Headquarters Services, Directorate for Information Operations and

Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-0062, Washington DC 20503. Please DO NOT RETURN your form to either of these addresses. Send your completed form to: SAF/AQCP, 1060 Air Force Pentagon, Washington DC

TO: (Contracting Officer) FROM: (Contractor) DATE

CONTRACT NUMBER SUBMISSION NUMBER SUBMITTAL

PREVIOUS SUBMISSION NUMBER PROJECT NUMBER

TO BE COMPLETED BY CONTRACTOR FOR GOVERNMENT USE ONLY

ITEM

NO.

SPECIFICATION SECTION/

PARA NO./DRAWING NO.

DESCRIPTION OF MATERIAL

(Include Type, Model Number, Catalog Number, Mfg., etc.)

AP-

PROVED

DISAP-

SEE

REVERSE

INITIAL

BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT

THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.

DATE (YYYYMMDD) TYPE OR PRINT NAME AND GRADE SIGNATURE

FOR GOVERNMENT USE ONLY

TO: (Base Civil Engineering Officer)

For Evaluation and Action RNLT ________________ OR SOONER

TO: (AF Contracting Office)

RECOMMEND APPROVAL DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE

TO: (Contractor)

APPROVED

DISAPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE. REQUEST

RESUBMITTAL ON DISAPPROVED ITEMS WITHIN ____ DAYS OF DATE SHOWN BELOW.

AF IMT 3000, 20030901, V1 PREVIOUS EDITION IS OBSOLETE.

New Resubmittal

COMMENTS

(Number to correspond with applicable Item Number on reverse)

INSTRUCTIONS TO CONTRACTORS

1. The term "material" is defined as articles, supplies, raw materials, equipment, parts, components, and end items that are to be incorporated into the work required by the contract.

2. This form is to be used by contractors for submitting Shop Drawings, Equipment Data, Manufacturer's Literature and Certificates and samples of Materials to the Government for approval in accordance with the provisions of this contract. Unless otherwise specified, it is to be prepared in 4 copies, signed, and provided to the contracting officer with appropriate attachments.

3. Item(s) to be approved will be clearly tabbed or identified. Data pertaining to item(s) to be approved will be clearly identified or tabbed, particularly where documents are voluminous, in order to properly evaluate the materials or articles to be incorporated in the work. Each attachment will be numbered to correspond with the item number shown on the face of this form.

4. Requests submitted shall be numbered consecutively, by contract, in the space entitled "Submission No.". This number, in addition to the Contract No., will be used to identify each Material Approval Submittal. Resubmissions will be indicated in the appropriate block and the insertion of previous submission number and data in addition to a new submission number. A single submission should be used for all work of a section of the specifications, but in NO instance should the submission include work for more than one (1) contract. Submittals requiring priority handling will be submitted by separate submittal using the form and so marked across the face of the form.

5. This Material Approval Submittal is not valid unless it is signed by the contracting officer. This approval is required as called for by the contracting officer under the terms of this contract.

AF IMT 3000, 20030901, V1 (REVERSE)

242 SOUTH TREADAWAY

ABILENE, TX 79602

Contact: MITCHELL DRINNON

Submittal Data

DYESS AFB-8040

REPAIR MAINTENANCE SHOP-BLDG. 8040

Submitted by:

BATJER AND ASSOCIATES

2825 PINE STREET

ABILENE, TX 79601

Table of Contents

Spec # Section Manufacturer Doc Name Doc #

P-1

KOHLER K-96053-0 WELLCOMME ULTRA TOP SPUD FLR

MNT BWL 1.1GPF-1.6GPF

P-1A

GEMLINE GL212SSCWH EL O/F PLST SSC SEAT L/C WH 2

P-1B

SLOAN 3450049 ROYAL OPT 111-1.28ESS HWIRE WC FV

1.28

P-2

KOHLER K-4991-ET-0 BARDON 1/8 GPF URINAL TOP 4

SLOAN ROYAL OPTIMA SENSOR ACTIVATED

FLUSHOMETERS, MODEL 186 ES-S TMO

JAY R SMITH 0636-M32 SUPPORT L/BPLT URN 6

P-4

ELKAY/HALSEY TAYLOR SERVICE SINK, WALL MOUNTED, WITH

DRAINBOARD, DOUBLE PEDAL CONTROL,

MODELS ESS4924RFC AND ESS4924R

DEARBORN BRASS BRASS TUBULAR 1-1/2" P-TRAP WITHOUT

CLEANOUT

P-5

ELKAY/HALSEY TAYLOR ELKAY ENHANCED EZH2O BOTTLE FILLING

STATION & SINGLE ADA COOLER FILTERED 8

GPH STAINLESS, MODEL LZS8WSSP

DEARBORN BRASS BRASS TUBULAR 1-1/4" P-TRAP WITHOUT

CLEANOUT

JONES STEPHENS FAUCET FLEXIBLE STAINLESS-STEEL PLUMBING

CONNECTORS, S04200-S04205

BRASS CRAFT 1/2X1/2IN CHR COMP STP 12

JONES STEPHENS POLY BAGGED ESCUTCHEONS, E01-049, E01-050 13

P-6

BRADLEY WS-1WCA-EF-S15-ST 14

P-7

FIAT 36WL 15

P-8

KOHLER BELLERA PULL-DOWN KITCHEN SINK FAUCET,

K-560

ELKAY/HALSEY TAYLOR SINK ACCESORIES DRAIN FITTING, MODEL LK35,

LK35B, LK35L

DEARBORN BRASS BRASS TUBULAR 1-1/2" SEMI-CAST P-TRAPS 18

BRASS CRAFT 1/2X1/4IN CHR COMP STOP 19

JONES STEPHENS CHROME PLATED BRASS PIPE NIPPLE, N16300 20

MCGUIRE MANUFACTURING ALL CAST BRASS NIPPLES AND SET SCREW

FLANGES, MODEL 1127-N200060

LEONARD VALVE THERMOSTATIC MIXING VALVE MODEL 210 22

P-9

BRADLEY FL-1L-S53-SHANK-TMA-NSD-(STD COLOR)-COAL 23

P-10

CRANE PLUMBING TERRAZZO MOP SERVICE BASIN 12" DEPTH WITH

6" DROP FRONT

KOHLER KINLOCK SERVICE SINK FAUCET, K-8907 25

P-11

GE APPLIANCE GUD27ESSJWW 26

P-12

BRADLEY MF2949-AST4-STD-NSD-TMA 27

P-13

SMITH JAY R FLOOR OR SHOWER DRAINS WITH ADJUSTABLE

STRAINER HEADS_2005

PRO-SET TRAP GUARD 29

P-13A

SMITH JAY R FUNNEL-CEPTOR INDIRECT WASTE DRAINS

WITH ADJUSTABLE STRAINER HEADS_3510

PRO-SET TRAP GUARD 31

P-14

A. O. SMITH WATER PRODUCTS

COMPANY

CUSTOM XI HEAVY DUTY COMMERCIAL

ELECTRIC WATER HEATERS, MODEL

DSE-5-DSE-120

P-15

EH512L Submittal 33

1221W120H-6A17J Submittal 34

GB-36-100 35

LB-3602 36

GA-400AAF40 37

1520-20 38

P-16

BRADLEY S19314SBFW 39

P-17

LAWLER 008470123 MIXING VALVE 40

P-18

ARROWHEAD BRASS 465-04LF 41

ARROWHEAD BRASS 59ABP 42

P-19

SIOUX CHIEF ADJUSTABLE ON-GRADE FLOOR DRAIN,

832-36PNR

HOT WATER CIRCULATING PUMP

BELL & GOSSETT XYLEM INC WET ROTOR CIRCULATORS AND ACCESSORIES

FOR POTABLE WATER APPLICATIONS

FLOOR CLEANOUT

SMITH JAY R FINISHED FLOOR CLEANOUTS WITH

"TWIS-TO-FLOOR" ADJUSTABLE TOPS, ROUND

NICKEL BRONZE TOP, 4031 SERIES

WALL CLEANOUT

JAY R. SMITH 4530Y 46

PROJECT: DYESS AFB

BUILDING 8040

CONTRACTOR: BATJER AND ASSOCIATES

P-1

K-96053-0 KOHLER K-96053-0 WELLCOMME ULTRA TOP SPUD FLR MNT BWL

1.1GPF-1.6GPF

P-1A

GL212SSCWH GEMLINE GL212SSCWH EL O/F PLST SSC SEAT L/C WH

P-1B

3450049 SLOAN 3450049 ROYAL OPT 111-1.28ESS HWIRE WC FV 1.28

P-2

K-4991-ET-0 KOHLER K-4991-ET-0 BARDON 1/8 GPF URINAL TOP

3452643 SLOAN ROYAL OPTIMA SENSOR ACTIVATED FLUSHOMETERS,

MODEL 186 ES-S TMO

0636-M32 JAY R SMITH 0636-M32 SUPPORT L/BPLT URN

P-4

ESS4924RFC ELKAY/HALSEY TAYLOR SERVICE SINK, WALL MOUNTED, WITH DRAINBOARD,

DOUBLE PEDAL CONTROL, MODELS ESS4924RFC AND

ESS4924R

704DFBN-1 DEARBORN BRASS BRASS TUBULAR 1-1/2" P-TRAP WITHOUT CLEANOUT

P-5

LZS8WSSP ELKAY/HALSEY TAYLOR ELKAY ENHANCED EZH2O BOTTLE FILLING STATION &

SINGLE ADA COOLER FILTERED 8 GPH STAINLESS, MODEL

LZS8WSSP

701DFBN-1 DEARBORN BRASS BRASS TUBULAR 1-1/4" P-TRAP WITHOUT CLEANOUT

S04203 JONES STEPHENS FAUCET FLEXIBLE STAINLESS-STEEL PLUMBING

CONNECTORS, S04200-S04205

KTCR19X-C BRASS CRAFT 1/2X1/2IN CHR COMP STP

E01050 JONES STEPHENS POLY BAGGED ESCUTCHEONS, E01-049, E01-050

P-6

BRADLEY WS-1WCA-EF-S15-ST

P-7

FIAT 36WL

P-8

K-560-CP KOHLER BELLERA PULL-DOWN KITCHEN SINK FAUCET, K-560

LK35 ELKAY/HALSEY TAYLOR SINK ACCESORIES DRAIN FITTING, MODEL LK35, LK35B,

LK35L

510-1 DEARBORN BRASS BRASS TUBULAR 1-1/2" SEMI-CAST P-TRAPS

KTR17X-C BRASS CRAFT 1/2X1/4IN CHR COMP STOP

N16300 JONES STEPHENS CHROME PLATED BRASS PIPE NIPPLE, N16300

127050 MCGUIRE

MANUFACTURING

ALL CAST BRASS NIPPLES AND SET SCREW FLANGES,

MODEL 1127-N200060

210-TB LEONARD VALVE THERMOSTATIC MIXING VALVE MODEL 210

P-9

BRADLEY FL-1L-S53-SHANK-TMA-NSD-(STD COLOR)-COAL

P-10

TSBC1610501 CRANE PLUMBING TERRAZZO MOP SERVICE BASIN 12" DEPTH WITH 6" DROP

FRONT

K-8907-CP KOHLER KINLOCK SERVICE SINK FAUCET, K-8907

P-11

GE APPLIANCE GUD27ESSJWW

P-12

BRADLEY MF2949-AST4-STD-NSD-TMA

P-13

2005L03 SMITH JAY R FLOOR OR SHOWER DRAINS WITH ADJUSTABLE STRAINER

HEADS_2005

PRO-SET TRAP GUARD

P-13A

3510L03(-F11

05NB)

SMITH JAY R FUNNEL-CEPTOR INDIRECT WASTE DRAINS WITH

ADJUSTABLE STRAINER HEADS_3510

PRO-SET TRAP GUARD

P-14

DSE-120-208V

-30KW

A. O. SMITH WATER

PRODUCTS COMPANY

CUSTOM XI HEAVY DUTY COMMERCIAL ELECTRIC WATER

HEATERS, MODEL DSE-5-DSE-120

P-15

EH512L Submittal

1221W120H-6A17J Submittal

GB-36-100

LB-3602

GA-400AAF40

1520-20

P-16

BRADLEY S19314SBFW

P-17

LAWLER 008470123 MIXING VALVE

P-18

ARROWHEAD BRASS 465-04LF

ARROWHEAD BRASS 59ABP

P-19

832-4PNR SIOUX CHIEF ADJUSTABLE ON-GRADE FLOOR DRAIN, 832-36PNR

HOT WATER CIRCULATING PUMP

103401LF BELL & GOSSETT XYLEM

INC

WET ROTOR CIRCULATORS AND ACCESSORIES FOR POTABLE

WATER APPLICATIONS

FLOOR CLEANOUT

4031L04-NS SMITH JAY R FINISHED FLOOR CLEANOUTS WITH "TWIS-TO-FLOOR"

ADJUSTABLE TOPS, ROUND NICKEL BRONZE TOP, 4031

SERIES

WALL CLEANOUT

JAY R. SMITH 4530Y

F3000 #9

12-0053 Rpr 8040 - MS #09 - Plumbing Fixtures ( )

P-1

K-96053-0 WELLCOMME ULTRA TOP SPUD FLR MNT BWL 1.1GPF-1.6GPF

P-1A

GL212SSCWH EL O/F PLST SSC SEAT L/C WH

P-1B

3450049 ROYAL OPT 111-1.28ESS HWIRE WC FV 1.28

P-2

K-4991-ET-0 BARDON 1/8 GPF URINAL TOP

ROYAL OPTIMA SENSOR ACTIVATED FLUSHOMETERS, MODEL 186 ES-S TMO

0636-M32 SUPPORT L/BPLT URN

P-4

SERVICE SINK, WALL MOUNTED, WITH DRAINBOARD, DOUBLE PEDAL CONTROL, MODELS ESS4924RFC AND ESS4924R

BRASS TUBULAR 1-1/2" P-TRAP WITHOUT CLEANOUT

P-5

ELKAY ENHANCED EZH2O BOTTLE FILLING STATION & SINGLE ADA COOLER FILTERED 8 GPH STAINLESS, MODEL LZS8WSSP

BRASS TUBULAR 1-1/4" P-TRAP WITHOUT CLEANOUT

FAUCET FLEXIBLE STAINLESS-STEEL PLUMBING CONNECTORS, S04200-S04205

1/2X1/2IN CHR COMP STP

POLY BAGGED ESCUTCHEONS, E01-049, E01-050

P-6

WS-1WCA-EF-S15-ST

P-7

36WL

P-8

BELLERA PULL-DOWN KITCHEN SINK FAUCET, K-560

SINK ACCESORIES DRAIN FITTING, MODEL LK35, LK35B, LK35L

BRASS TUBULAR 1-1/2" SEMI-CAST P-TRAPS

1/2X1/4IN CHR COMP STOP

CHROME PLATED BRASS PIPE NIPPLE, N16300

ALL CAST BRASS NIPPLES AND SET SCREW FLANGES, MODEL 1127-N200060

THERMOSTATIC MIXING VALVE MODEL 210

P-9

FL-1L-S53-SHANK-TMA-NSD-(STD COLOR)-COAL

P-10

TERRAZZO MOP SERVICE BASIN 12" DEPTH WITH 6" DROP FRONT

KINLOCK SERVICE SINK FAUCET, K-8907

P-11

GUD27ESSJWW

P-12

MF2949-AST4-STD-NSD-TMA

P-13

FLOOR OR SHOWER DRAINS WITH ADJUSTABLE STRAINER HEADS_2005

TRAP GUARD

P-13A

FUNNEL-CEPTOR INDIRECT WASTE DRAINS WITH ADJUSTABLE STRAINER HEADS_3510

TRAP GUARD

P-14

CUSTOM XI HEAVY DUTY COMMERCIAL ELECTRIC WATER HEATERS, MODEL DSE-5-DSE-120

P-15

EH512L Submittal

1221W120H-6A17J Submittal

GB-36-100

LB-3602

GA-400AAF40

1520-20

P-16

S19314SBFW

P-17

008470123 MIXING VALVE

P-18

465-04LF

59ABP

P-19

ADJUSTABLE ON-GRADE FLOOR DRAIN, 832-36PNR

HOT WATER CIRCULATING PUMP

WET ROTOR CIRCULATORS AND ACCESSORIES FOR POTABLE WATER APPLICATIONS

FLOOR CLEANOUT

FINISHED FLOOR CLEANOUTS WITH "TWIS-TO-FLOOR" ADJUSTABLE TOPS, ROUND NICKEL BRONZE TOP, 4031 SERIES

WALL CLEANOUT

4530Y

TO Contracting Officer: Capt. Hillary Ince

FROM Contractor: FARR Builders LLC S. Gevers, San Antonio, TX 78210

DATE: 30 Aug 17

CONTRACT NUMBER: FA4661-15-D-0001

SUBMISSION NUMBER: 009

PREVIOUS SUBMISSION NUMBER:

PROJECT NUMBER: FNWZ 12-0053

ITEM NORow1: 1

SPECIFICATION SECTION PARA NODRAWING NORow1: Per Sow

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow1: plumbing fixture submittals

INITIALRow1: PR

ITEM NORow2:

SPECIFICATION SECTION PARA NODRAWING NORow2:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow2:

INITIALRow2:

ITEM NORow3:

SPECIFICATION SECTION PARA NODRAWING NORow3:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow3:

INITIALRow3:

ITEM NORow4:

SPECIFICATION SECTION PARA NODRAWING NORow4:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow4:

INITIALRow4:

ITEM NORow5:

SPECIFICATION SECTION PARA NODRAWING NORow5:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow5:

INITIALRow5:

ITEM NORow6:

SPECIFICATION SECTION PARA NODRAWING NORow6:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow6:

INITIALRow6:

ITEM NORow7:

SPECIFICATION SECTION PARA NODRAWING NORow7:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow7:

INITIALRow7:

ITEM NORow8:

SPECIFICATION SECTION PARA NODRAWING NORow8:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow8:

INITIALRow8:

ITEM NORow9:

SPECIFICATION SECTION PARA NODRAWING NORow9:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow9:

INITIALRow9:

ITEM NORow10:

SPECIFICATION SECTION PARA NODRAWING NORow10:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow10:

INITIALRow10:

ITEM NORow11:

SPECIFICATION SECTION PARA NODRAWING NORow11:

DESCRIPTION OF MATERIAL Include Type Model Number Catalog Number Mfg etcRow11:

INITIALRow11:

DATE YYYYMMDD: 2017-08-2

TYPE OR PRINT NAME AND GRADE: Rene Garcia

TO Base Civil Engineering Officer: 502 CE

RNLT:

DATE YYYYMMDD_2:

TYPE OR PRINT NAME AND GRADE_2:

TO AF Contracting Office:

DATE YYYYMMDD_3: 20171215

TYPE OR PRINT NAME AND GRADE_3: Patrick Rolan, GS-12

TO Contractor:

DATE YYYYMMDD_4:

TYPE OR PRINT NAME AND GRADE_4:

2017-12-15T10:36:36-0600

ROLAN.PATRICK.M.1515150249

Text5:

Check Box6: Yes

Check Box7: Off

Check Box8: Off

Check Box9: Off

Check Box10: Off

Check Box11: Off

Check Box12: Off

Check Box13: Off

Check Box14: Off

Check Box15: Off

Check Box16: Off

Check Box17: Off

Check Box18: Off

Check Box19: Off

Check Box20: Off

Check Box21: Off

Check Box22: Off

Check Box23: Off

Check Box24: Off

Check Box25: Off

Check Box26: Off

Check Box27: Off

Check Box28: Off

Check Box29: Off

Check Box30: Off

Check Box31: Off

Check Box32: Off

Check Box33: Off

Check Box34: Off

Check Box35: Off

Check Box36: Off

Check Box37: Off

Check Box38: Off

Check Box3: Yes

Check Box50: Off

Check Box4: Yes

Check Box5: Off

Check Box39: Off

Check Box40: Off

COMMENTS Number to correspond with applicable Item Number on reverseRow1:

MATERIAL APPROVAL SUBMITTAL

(See Instructions on Reverse)

Form Approved OMB No 9000-0062 Expires May 31, 2005

Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-0062, Washington DC 20503. Please DO NOT RETURN your form to either of these addresses. Send your completed form to: SAF/AQCP, 1060 Air Force Pentagon, Washington DC

TO: (Contracting Officer) FROM: (Contractor) DATE

CONTRACT NUMBER SUBMISSION NUMBER SUBMITTAL

PREVIOUS SUBMISSION NUMBER PROJECT NUMBER

TO BE COMPLETED BY CONTRACTOR FOR GOVERNMENT USE ONLY

ITEM

NO.

SPECIFICATION SECTION/

PARA NO./DRAWING NO.

DESCRIPTION OF MATERIAL

(Include Type, Model Number, Catalog Number, Mfg., etc.)

AP-

DISAP-

SEE

REVERSE INITIAL

BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT

THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.

FOR GOVERNMENT USE ONLY

TO: (Base Civil Engineering Officer)

For Evaluation and Action RNLT ________________ OR SOONER

TO: (AF Contracting Office)

RECOMMEND APPROVAL DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE

TO: (Contractor)

APPROVED DISAPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE. REQUEST

RESUBMITTAL ON DISAPPROVED ITEMS WITHIN ____ DAYS OF DATE SHOWN BELOW.

AF IMT 3000, 20030901, V1 PREVIOUS EDITION IS OBSOLETE.

Capt. Hillary Ince FARR Builders LLC S. Gevers, San Antonio, TX 78210 30 Aug 17

FA4661-15-D-0001 009

FNWZ 12-0053

1 Per Sow plumbing fixture submittals PR

2017-08-2 Rene Garcia

502 CE

20171215 Patrick Rolan, GS-12 Digitally signed by ROLAN.PATRICK.M.1515150249 Date: 2017.12.15 10:36:36 -06'00'

20171215 SrA Vitaliy Poprozhuk

20171215 Capt Hilary Ince

X

COMMENTS

(Number to correspond with applicable Item Number on reverse)

INSTRUCTIONS TO CONTRACTORS

1. The term "material" is defined as articles, supplies, raw materials, equipment, parts, components, and end items that are to be incorporated into the work required by the contract.

2. This form is to be used by contractors for submitting Shop Drawings, Equipment Data, Manufacturer's Literature and Certificates and samples of Materials to the Government for approval in accordance with the provisions of this contract. Unless otherwise specified, it is to be prepared in 4 copies, signed, and provided to the contracting officer with appropriate attachments.

3. Item(s) to be approved will be clearly tabbed or identified. Data pertaining to item(s) to be approved will be clearly identified or tabbed, particularly where documents are voluminous, in order to properly evaluate the materials or articles to be incorporated in the work. Each attachment will be numbered to correspond with the item number shown on the face of this form.

4. Requests submitted shall be numbered consecutively, by contract, in the space entitled "Submission No.". This number, in addition to the Contract No., will be used to identify each Material Approval Submittal. Resubmissions will be indicated in the appropriate block and the insertion of previous submission number and data in addition to a new submission number. A single submission should be used for all work of a section of the specifications, but in NO instance should the submission include work for more than one (1) contract. Submittals requiring priority handling will be submitted by separate submittal using the form and so marked across the face of the form.

5. This Material Approval Submittal is not valid unless it is signed by the contracting officer. This approval is required as called for by the contracting officer under the terms of this contract.

AF IMT 3000, 20030901, V1 (REVERSE)

2017-12-15T15:08:48-0600

POPROZHUK.VITALIY.NIKOLAYEVI.1462881092

2017-12-15T15:10:32-0600

INCE.HILARY.RAE.1368173785

File details come from the government source that posted it. Updated .