B.3.4 - 01020D - Appendix D NFPA 780 LP Determination Explanation.doc

NFPA Standard DOC document 27 KB Posted

Attached to
A&E DESIGN/BUILD FIRST ARTICLE TESTING STORAGE FACILITY
Solicitation number
F3QCCL1025A008
Issued by

About this file

Appendix D NFPA 780 LP Requirements Determination

View the file

Other versions and copies of NFPA 780

Who attaches NFPA 780

Other files

File Type Posted
Site Visit Attendees.pdf PDF
First Article Testing Storage Facility questions 06APR11.docx DOCX document
BFS Part 7 - Communications 2007.pdf PDF
BFS Part 4 - Architectural General and Compatibility.pdf PDF
K - 01560 - Environmental Requirements - Jun 10.doc DOC document
O - UHHZ 100138 Appendix C Safety Plan.docx DOCX document
BFS Part 3 - Civil-Structural.pdf PDF
J.1 - 01540 - Green Procurement ATTACHMENT 2.doc DOC document
F - 01310 - CADD As-Built Drawings.doc DOC document
BFS Part 5 - Mechanical.pdf PDF
E.1 - 01300A - AF Form 66_Example.pdf PDF
N.0 - 133419 - Pre-engineered Metal Building.doc DOC document
BFS Part 6 - Electrical.pdf PDF
BFS Part 2 - Environmental .pdf PDF
J.2 - 01540 - Green Procurement ATTACHMENT 3.doc DOC document
001 Index of Drawings.pdf PDF
L - 01580 - Safety Requirements.doc DOC document
301 Bldg Section.pdf PDF
J.3 - 01540 - Green Procurement ATTACHMENT 7.doc DOC document
B.3.0 - 01020 - Construction Design Performance Requirements.doc DOC document
Wage Determination.pdf PDF
I.1 - 01503 - Contract Administration.doc DOC document
E.0 - 01300 - Submittals Contractor-Furnished Items.doc DOC document
BFS Part 1 - Intro and General .pdf PDF
101 Floor Plan.pdf PDF
B.3.3 - 01020C - Appendix C GEC Soils Report - First Art TestStor Fa.pdf PDF
B.3.1 - 01020A - Appendix A References.doc DOC document
M - 01730 - Operations and Maintenance Data.doc DOC document
J.0 - 01540 - Green Procurement.doc DOC document
B.2 - 01005 - Statement Of Work.doc DOC document
B.3.2 - 01020B - Appendix B Fire Protection Life Safety.doc DOC document
201 Elevations.pdf PDF
101 Site Demolition Plan.pdf PDF
B.3.5 - 01020E - Appendix D NFPA 780 LP Requirement Determination.xls XLS spreadsheet
FA8501-11-R-0018 solicitation.doc DOC document
D - 01040 - Site Requirements.doc DOC document
G - 01501 - Temporary Services - Contractor.doc DOC document
102 Site Plan.pdf PDF
C - 01030 - Design-Build Design After Award.doc DOC document
H - 01502 - Temporary Services - Cont Occupancy.doc DOC document
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

October 15, 2004

APPENDIX D -- NFPA 780 Lightning Risk Assessment

The NFPA 780 Lightning Risk Assessment is designed to assist engineers and building owners in determining the risk of damage to a facility due to lightning strike. Several factors such as the size and height of a structure, occupancy, contents, and geographical location help to determine the need for a lightning protection system. Each factor is given a particular number or coefficient that is entered into a formula to determine the expected lightning stroke frequency and the tolerable lightning stroke frequency to a structure.

The first coefficient is based on the location of a structure and its relationship to its surroundings and other structures. A structure located close to other buildings is assigned a low coefficient and a structure isolated from other buildings and located on a hilltop would be assigned the highest coefficient. This coefficient is used separate from the other coefficients to determine the expected lightning frequency.

The second coefficient applies to the physical construction of the structure. A structure with a metal roof and metal walls is assigned the lowest coefficient. A structure constructed of wood or other flammable materials is given the highest coefficient.

The third coefficient considers the contents of the structure. If the contents of the structure are of low value and non-flammable, a low coefficient is assigned. If the contents are flammable, exceptional value or irreplaceable items the highest coefficient is assigned.

The fourth coefficient considers the occupancy and ability to evacuate the structure. Unoccupied structures are given the lowest coefficient. Structures such a schools or stadiums that are difficult to evacuate are assigned the highest coefficient.

The fifth coefficient is determined by the consequence of a lightning strike to the structure. If the services of the structure provide no environmental impact then the lowest coefficient is assigned. If interruption of services results in consequences to the environment then the highest coefficient is assigned.

The structural, contents, occupancy, and lightning consequence coefficients are then applied to a formula that determines the tolerable lightning frequency. Tolerable lightning frequency measures the damage risk to a structure, the environment, and monetary loss. The tolerable lightning frequency is compared to the expected lightning frequency in determining the need for a lightning protection system.

The expected lightning frequency is formulated using the lightning flash density for the region where the structure is located, the collective area of the structure, and the environmental coefficient.

The lightning flash density is a number corresponding to the location of the structure. A map shows the lightning flash density in flash/km(/year provided by Global Atmospherics and U.S. National Lightning Detection Network.

The collective area of a structure is simply determined by the height, width, and length of the structure.

After the results of the expected lightning frequency and the tolerable lightning frequency have been calculated then the determination of a lightning protection system can be made. If the expected lightning frequency figure is less than the tolerable lightning frequency (Nd < Nc), then the need for a lightning protection system is optional. If the expected lightning frequency is higher than the tolerable lightning frequency (Nd > Nc), then a lightning protection system should be installed on the structure.

There are a lot of factors involved in determining the need for a lightning protection system. The safety of the occupants and the monetary loss are the most important when determining that need. The NFPA Lightning Risk Assessment provides valuable information to engineers and owners when deciding on that important investment.

File details come from the government source that posted it. Updated .