Robins AFB Facility Standard
BASE FACILITY STANDARD (BFS) -- ROBINS AFB, GA
(Also known as Installation Design Guide)
FOR ARCHITECT-ENGINEER FIRMS AND CONTRACTORS
PERFORMING DESIGN SERVICES AND CONSTRUCTION FOR ROBINS AFB
PART 4 - ARCHITECTURAL GENERAL AND
ARCHITECTURAL COMPATIBILITY STANDARD
NOTE: This document is in two parts
The first part contains the architectural general standards.
The second part is the architectural compatibility standard.
Revised 24 Aug 2005
ARCHITECTURAL GENERAL
1. GENERAL CONSIDERATIONS:
a. This is one part of the Robins AFB Base Facility Standards. Refer questions or exception requests to the Design Chief in 778 CES/CEPD. Any exceptions granted to these requirements shall be noted clearly in the project design analysis by using a Deviation Request.
b. The buildings on Robins AFB are organized into four architectural compatibility zones.
Facility operations and location determine the functional zones. This designation identifies desired exterior treatment as well as other design considerations as contained in the Robins Architectural Compatibility Standards. These zones are as follows:
(1) Industrial Flightline
(2) Operational Flightline
(3) Admin & Industrial
(4) Housing
c. Desired architectural styles: Buildings of various styles are dispersed throughout the Base. In a few instances, their styles conflict with present use. It is desired that the styles of the new buildings relate to the older buildings. It is also desired that a sense of order be applied to the present random distribution of architectural styles throughout the Base. Further guidelines and/or questions concerning architectural styles, materials, colors, etc. are available from the Base Architectural Compatibility Officer in 778 CES/CEPD.
d. All design shall be in accordance with applicable UFC's, AFI's, ETL's, and all other applicable codes and regulations as referenced herein. Also conform to NFPA 101 - Life Safety Code and the current International Building Code (IBC). If there is a conflict, normally use the more stringent requirement. The specifications shall require all materials and equipment to be current production items.
All drawings and specifications on all submittal phases shall be stamped (labeled) “FOR
OFFICIAL USE ONLY”.
e. All construction materials and skilled labor are available within the area of Warner Robins, Macon, and Atlanta - approximately within a 120-mile radius of the project site. No borrow or fill material is available on Robins Air Force Base. All necessary fill in excess of that obtained from excavation on the project must be obtained from sources from off the Base.
f. The facility shall be barrier-free and designed to meet the Uniform Federal Disability Act and Americans with Disabilities Act (ADA).
2. ARCHITECTURAL COMPATIBILITY STANDARDS:
a. The intent of our Architectural Compatibility Standards is to produce designs that reflect the Air Force goal of quality, creative designs with "understated excellence." Understated excellence is characterized by these considerations:
(1) Simplicity in design
(2) Durability of materials and finishes
(3) Reliability in utility and building systems
(4) Efficiency in function
(5) Completeness and appropriateness of detail
(6) Coordination in appearance and maintainability in configuration and layout
(7) Avoidance of grand scale and plushness
b. Facility floor plans and finish schedule for interior/exterior shall comply with the following publications:
(1) Robins Architectural Compatibility Standards
(2) AFP 88-41, Interior Design Guide
(3) AFH 32-1084, Facility Requirements
(4) AFM 88-4, Chapter 9, Raised Floor Systems
(5) UFC 3-120-01, Sign Standards
(6) AFR 85-10, Operation and Maintenance of Real Property
(7) AFI 32-1050, Roof Systems Management
(8) AFR 88-25, Military Family Housing Design and Construction Management and Robins AFB Housing Community Plan
(9) Air Force Carpet Policy ETL 07-4
(10) Air Force Materiel Command Commander’s Guide to Interior Design
(11) Air Force Materiel Command Commander’s Guide to Facility Excellence
c. Automatic data processing support: Provide raised floors similar to the aluminum type made by Floating Floors, Inc.
d. Interior/Exterior color and material presentation boards are required for approval on all projects. Provide 8 1/2 x 11 boards in binder format with heavy samples mechanically fastened. Color boards are required with the Preliminary (60%) and First Final (85%) submittals.
e. All exterior paint colors must conform to the Base exterior color scheme as defined in the Robins Architectural Compatibility standards. Certain exterior materials such as brick are standardized also. The Base’s standard brick is Boral Brick Corporation’s Red Matex. In some cases, the brick must match adjacent facilities to achieve a uniform architectural appearance. Obtain approval from the Base Project Manager for the brick and mortar selection.
3. INTERIOR DESIGN STANDARDS
a. Interior finishes and furnishings are an important and integral part of facility construction, upgrade, and maintenance programs. While we often have design guidelines and budget limitations, we still expect quality professional design that does not have a "military" look. For instance, the use of dark wood paneling is no longer a required status symbol for executive offices. Dark blue or black doorframes are also outdated. If we are to achieve a clean, efficient "corporate look," we do not wish to perpetuate the mistakes of the past. We want to exceed the "minimum needs of the government" by addressing physical and psychological needs and providing a comfortable work or living environment.
Function, maintainability, energy efficiency, and a pleasing general atmosphere are all-important elements of the design.
b. Interior structural materials and finishes are part of the design of all buildings. This includes anything attached to the building such as wall covering, wall bases, flooring, door and window trim, millwork and cabinetwork, hardware, interior signage, and all items with colors, patterns, or textures.
Projects that contain only interior finishes are referred to as a Structural Interior Design (SID).
c. A project with furnishings is identified as a Comprehensive Interior Design (CID).
Furnishings must include systems furniture or conventional office furniture, artwork, plants, window treatment, bedspreads, waste receptacles, and other decorative or functional accessories.
d. Systems furniture (Prewired workstations) shall be included as part of the construction requirements for all new administrative facilities and all administrative areas of any new facility when the administrative area contains at least 1,000 square feet of contiguous net office area. Refer to Engineering Technical Letters (ETL’s) 90-2, 88-10, and 90-04 for systems furniture guidelines.
e. Furniture shall be durable, easily maintained, and selected from current GSA vendors.
Upholstery shall be selected from manufacturer’s standard fabrics. Avoid using Customer's Own Material (C.O.M.) except in unique situations.
f. Equipment and furniture catalog cuts and price, presentation color/material boards, and interior perspectives shall be submitted for approval as part of the CID package.
g. All interior finishes shall be easily maintained, durable, and classic rather than trendy. The following guidelines apply to the majority of our projects:
(1) Permanent finishes such as ceramic tile, toilet partitions, and plastic laminate countertops shall be in neutral colors.
(2) Accent colors in brighter hues must be used in limited quantities such as a tile border or painted accent wall.
(3) Light colors shall be avoided for floor covering and high traffic areas.
(4) Type II vinyl wall covering must be used in neutral colors and subtle textures for upgraded areas.
(5) Corner guards, chair rails, or bumper guards shall be used depending upon the degree of wall protection required.
(6) Commercial vinyl tile shall be used in maintenance or industrial shop areas as well as break rooms.
(7) Walk off matting shall be used at all building entrances and in transition from shop areas to carpeted administrative areas.
(8) Wall colors shall be neutral, light-reflecting colors in a semi-gloss finish, if not directed otherwise.
(9) Ceilings shall be off-white in a flat or eggshell finish.
(9) Dark accent walls and murals are not recommended because of difficulty of repairing or maintaining.
(10) Semi-gloss or gloss paint is required for all trim, doors, and walls in areas that have moisture such as kitchens, restrooms, and bathrooms.
(11) For previously painted areas, site investigation is mandatory to determine proper surface preparation for new coatings or wall covering.
h. All carpet must comply with Air Force Carpet Policy (ETL 07-4). A patterned design or multicolored bold tweed has soil-hiding capabilities, where solid colors are recommended only for narrow borders and some billeting areas. Carpet tile is required only in areas with systems furniture or access floors. Avoid stripes and lines running parallel to walls and corridors.
i. Lighting solutions need to be explored to avoid boring uniformity and glare. Combinations of natural light, indirect lighting, general and task lighting can produce a more flexible and efficient plan.
Fixtures shall be easily maintained and have easily obtainable replacement bulbs (or lamps). Consider the color rendition of lamp selection for its appropriateness to the area and function.
j. Interior signage shall be part of SID (Structural Interior Design) and shall include building directories. Workstation identification signs shall be included with systems furniture packages in the CID (Comprehensive Interior Design).
k. The current custodial contractor shall be able to maintain easily the toilet accessories such as soap and towel dispensers. Avoid expensive multiple function units that are difficult to maintain.
l. Furnishings shall reflect the general style of the building but shall not be so trendy that they will be outdated in four or five years. Upholstery fabrics shall be durable and soil-hiding with brighter colors and patterns allowed. GSA vendors offer a wide variety of styles and upholstery options. Avoid using COM (customer’s own material) because of expense and complication of ordering process.
m. Artwork and plants are finishing touches that shall be included if the budget allows.
Landscapes or local themes are appropriate for public areas. Frames shall harmonize with other furnishings. Artificial plants soften formal arrangements and fill awkward corners.
n. The following Air Force publications are applicable to interior design and can be obtained from the applicable Design Section in 778 CES/CEC:
------- AFMC Facility Quality Standards ------- AF Carpet Selection Handbook ------- AF Interior Design Presentation Format ETL 07-4 Air Force Carpet Standard UFC 3-120-01 Sign Standards AFP 88-41 Interior Design Guidance ETL 90-7 AF General Interior Design Policy ETL 90-2 General Policy for Prewired Workstations and Systems Furniture ETL 90-4 Systems Furniture Guide Specifications ETL 89-10 Pre-Wired Workstations Guide Specifications
5. INTERIOR DESIGN - DORMITORIES
a. General: Well-coordinated, neutral color schemes hold up over longer periods. Good design extends beyond aesthetics to provide durability, acoustical, and energy-saving value, as well as morale enhancement for the inhabitants.
b. Finishes, Materials, and Colors: All permanent finishes shall be neutral colors. Medium range accent colors may be used only in small areas. Select neutral colors for surfaces that will have a long life, such as ceramic tile, mosaic, corian, laminates, window blinds, etc., to facilitate future finish material upgrades. Provide a pleasing color scheme in durable finish materials. Use color in non-permanent finishes to add interest and vitality, but do not allow color to dominate the environment.
Coordinate materials, finishes, color, and texture selection to compliment the overall building design and image.
c. Carpet: Removal of carpet to be replaced (if applicable) should be handled according to pre-approved plan for recycling. Carpet must be capable of recycling by down-cycling, waste-to-energy-conversion or another disposal strategy that keeps the carpet out of a landfill. Carpet shall comply with Carpet and Rug Institute’s Green Label Indoor Air Quality. Carpet must comply with guidelines of Presidential Executive Order 13101 and meet the intent of Section 6002 of the resource and Recovery Act (RCRA). Carpet with a small pattern, tweed design, or random design is preferred for its appearance retention. Solid color carpet is not authorized. Level-loop or combination or loop and cut pile carpet is recommended for corridors. Select a pattern that will not accentuate the length of corridor. A cut pile is recommended for living unit. Provide a solid walk-off area if the living unit opens to the exterior.
Heavy-duty commercial quality carpet cushion may be used in the living units, but cannot be used in the corridors. Living /bedroom areas have a heavy wear classification for carpet, and public areas (corridors, television and game rooms, etc.) have a severe wear classification.
d. Walk Off: Provide hard surface walk-off areas at exterior entrances to type B or C modules.
e. Hard Surface Flooring: Use commercial quality sheet vinyl composition tile (VCT) with a full depth pattern in the walk off area, vanity area, and the kitchen. Avoid white as a predominant color, “No wax” surfaces are not recommended, due to low durability.
f. Walls:
(1) Use vinyl wall covering as over smooth walls. Accent walls are optional, but must not be so bright or so dark as to shorten the room or negatively affect the interior lighting.
Consider a texture wall covering as an accent instead of dramatic contrasting colors.
Accent colors can also be used as textiles such as draperies and upholstery fabrics.
(2) Paint may be substituted for vinyl wall covering (VWC), but VWC is preferred.
Where paint is used, multi-colored, speckled paint systems are preferred.
g. Ceiling: Paint ceilings off-white in a flat or eggshell finish or provide a light colored acoustical textured treatment.
h. Bathrooms: Use slip resistant ceramic floor tiles in bathrooms. Specify a mottled or shaded tile to hide discoloration from detergents, etc. Use ceramic wall tiles from floor to ceiling around bathtubs s and showers. Colored grout matching the ceramic tile is recommended for low maintenance and good appearance. Other areas may be at wainscot height. Install shower curtain rod instead of glass shower doors for ease in maintenance. Specify rod at proper height for conventional shower curtains 1800 mm x 11800 mm (72”x 72”).
i. Window Treatment: Mini blinds, vertical blinds, draperies or combination are authorized. All window treatments must pass NFPA 701-1/702-2 Standard Method Fire Test for Flame Resistant Textiles and Films.
j. Furnishings. Furnishings shall reflect the general style of the building but shall not be so trendy that they will be outdated in four or five years. Upholstery fabrics shall be durable and soil-hiding with brighter colors and patterns allowed. GSA vendors offer a wide variety of styles and upholstery options. Avoid using COM (customer’s own material) because of expense and complication of ordering process. Refer to Dorm Design Guide and QIP (Quarters Improvement Plan) for additional guidance on standards.
6. LOCKING DEVICES:
a. The door hardware shall be compatible with the Base Master Keying System. The keying system shall have seven pin interchangeable cores and interchangeable construction cores. The interchangeable cores as a design basis shall be Best Lock or equivalent. The lockset shall be compatible with the Base Master System and shall be equal to Arrow, Falcon, Best Lock, or other locks that will accept the 7-pin Best-type core.
b. For those facilities that are not covered by the Base Master Keying System, provide keys and locks for any addition or renovation that are compatible with any existing master key and lock system that is to remain.
c. Furnish two master keys. These are to be sent direct to the Government's representative by registered mail.
d. Furnish two copies of keying control transcripts with 100% expansion per complex as listed in hardware set. These are to be sent direct to the Government's representative by registered mail or other certified means of delivery.
e. Maintenance Control: Furnish maintenance repair kits and manuals as listed in hardware set.
These are to be sent direct to the Government's representative by registered mail or other certified means of delivery.
f. All padmounted transformers, exterior padmounted switchgear cabinets, etc. are to be equipped with a Best Lock Corporation padlock, lock number 21B720L-R with core number 8A59, 1 1/2" short shank. This is the same lock that is used on all other high voltage equipment on Robins AFB, and it is imperative that exterior electrical personnel have one-key access to all high voltage equipment.
7. SCREENING MECHANICAL EQUIPMENT: Mechanical equipment, transformers, etc. shall be screened. Follow force protection requirements where more stringent than those below.
a. Low visitor or low aesthetic areas of the base: Use chain link fences
b. Administrative, community, recreation areas, and other areas as applicable for aesthetic purposes: Provide Rohn fences with an asphalt or concrete mowing strip at least 2’ wide (one feet on each side) to prevent grass growth next to the fence. Alternate methods include brick or pressure treated wood screens. Design to not block airflow for cooling the equipment.
c. Consider bushes and small trees if they do not block airflow for cooling the equipment, and if they provide the necessary visual screening.
8. WINDOWS: Follow force protection requirements to prevent flying glass shards. (Under Development)
a. Industrial Casement
b. Storefront
c. Residential
9. EXTERIOR DOORS: Keep these to a minimum. The following doors are required:
a. Main ingress and egress doors for personnel.
b. Utility room exterior doors.
(1) Main Mechanical and Electrical Rooms shall be located on the exterior walls of the facility, and their doors shall be on the exterior walls to improve accessibility for CEG shop personnel and to minimize disruptions to user personnel.
(2) Comm Rooms and non-main utility rooms may be located in the interior of the facility with interior doors.
(3) All shall be provided with locks such that only CE has the keys for these rooms.
10. ACOUSTICAL AND SUSPENDED CEILINGS: Center the tile grid on the center of the room.
Space the tiles such that fractional pieces are of identical shape on the outside edges on opposite sides of the room.
11. Paint for Hangar Floors; AFMC Policy on Painting Concrete Floors
<<<<< END OF ARCHITECTURAL GENERAL SECTIONS >>>>>
ARCHITECTURAL COMPATIBILITY STANDARD
Sections
1.0 Executive Summary
2.0 Architectural Districts
3.0 Historic Preservation
4.0 Handicapped Accessibility
5.0 Base Comprehensive Planning
6.0 Architectural Finishes
7.0 Roofing
8.0 Exterior Signage
9.0 Traffic Considerations
10.0 Landscaping
11.0 Interior Design
12.0 Self-Help Store
13.0 Energy Conservation
14.0 References
1.0 EXECUTIVE SUMMARY
“The intention is not to limit creativity, but to aid the designer in reaching decisions consistent with the goal of this program and to create a unified AFMC image.”
AFMC Facility Quality Program (1996)
1.1 INTRODUCTION
In accordance with the goals of the AFMC Facility Quality Program, Robins AFB has developed the following Architectural Compatibility Standards to ensure consistency in future design and construction projects.
This plan is not intended to stifle creativity, nor does it advocate “cookbook” architecture.
It simply communicates and illustrates current design standards which will unify and strengthen the architectural fabric of Robins Air Force Base (RAFB) and the Warner Robins Air Logistics Center (WR-ALC). Exterior standards apply to all organizations on base including hosted units, AAFES, Commissary, and commercial organizations.
1.2 How to Use This Document
Critical elements of this plan are identified in the table of contents. Specific compatibility standards and illustrations are included on the pages that follow. In addition, more detailed reference documents are listed at the end of this document. This planning document is intended to be a useful reference tool to ensure architectural compatibility in all future maintenance and repair and construction projects.
1.3 Architectural Compatibility Manager
78 CEG/CE has assigned a Base Architectural Compatibility Manager in accordance with the goals and directives of the AFMC Facility Quality Program. The compatibility manager is responsible for ensuring that all facility projects are compatible with the standards set forth in this document.
The Architectural Compatibility Manager is responsible for maintaining and updating this plan.
2.0 Architectural Districts
For Purposes of this plan, Robins AFB has been divided into four Architectural Districts which identify specific areas where compatibility with adjacent facilities shall be stressed. Some architectural issues, such as paint and signage, do not vary from district to district and become unifying elements in the base master plan. The four Architectural Districts are summarized below and described in further detail on the pages that follow.
District 1 – Industrial Flightline
This district is best described as the secure area which defines the active Flightline excluding District 2. A great majority of the facilities are metal hangars with secondary maintenance and administrative facilities constructed of concrete block.
District 2 – Operational Flightline
District 2 is the remaining portion of the secure Flightline located to the east and west of the runway. A majority of the facilities in this district will be brick with bronze standing seam metal roofs.
District 3 – Administrative/Industrial
This district identifies all remaining facilities found throughout the base excluding the Flightline and all family housing units.
District 4 – Housing
District 4 is comprised of 807 Military Family Housing units found at various locations throughout the base.
DISTRICT 1 – Industrial Flightline
District 1 is best described as the secure area which defines the active Flightline excluding District 2 to the east and west. A great majority of the facilities are large hangars to support the Programmed Depot Maintenance (PDM) of the F-15, C-130, and C-141 aircraft. Secondary maintenance and administrative facilities are also scattered throughout District 1.
2.1 Industrial Flightline
The Industrial Flightline District is dominated by large aircraft hangars with related ancillary buildings. In an industrial setting such as District 1, it is obvious that buildings such as hangars and maintenance shops can be unappealing built forms. Careful attention to massing and scale is critical in order to assure compatibility with existing facilities.
Designers should carefully proportion the buildings’ facades such that doorways, entries, windows, and other like elements maintain a human scale.
Mechanical equipment should be screened from view and protected from vehicular traffic.
The majority of District 1 facilities are metal skinned. Future construction projects will specify factory-painted metal finishes with a 20-year warranty, which are compatible with existing facilities and the color standards in Section 6.0.
Avoid the use of brick. Use pre-finished metals or concrete block construction.
Roof surfaces shall be compatible with the lighter-colored base color standards in order to reflect the heat.
Building 125 serves as an excellent example upon which to build.
District 2 – Operational Flightline
As illustrated above, District 2 is the remaining portion of the secure Flightline located to the east and west of the active runway. It also includes the newer Air National Guard area. Compatibility within this district is based upon the Air Combat Command (ACC) Architectural and Landscape Design Standards which have been prepared and approved by both Robins AFB and ACC in an effort to define compatibility standards for the new construction supporting the completed Joint STARS mission beddown. These standards were also followed in the recently completed ANG beddown.
2.2 Operational Flightline
A majority of the facilities within District 2 will be brick with bronze standing seam metal roofs in compliance with the architectural standards of the Joint STARS and Air National Guard mission beddowns. Existing administrative and maintenance facilities are predominantly constructed of concrete block and painted to match the base color scheme.
Several metal hangars and other industrial facilities are also found in District 2.
Every effort shall be made to coordinate new construction or maintenance and repair projects with the design standards prepared for the Joint STARS mission beddown. Brick shall be the architectural finish of choice for all administrative facilities. Hangars shall be prefinished metals consistent with the base color standards found in Section 6.0 or a combination of brick and metal.
DISTRICT 3 – Administrative/Industrial
District 3 identifies the largest land use area on Robins AFB. This district identifies all remaining administrative and industrial facilities found throughout the base excluding the Flightline and all family housing units. It is an assemblage of complex and unique operational and functional areas with irregular boundaries.
2.3 Administrative/Industrial
District 3 is comprised of many facilities which have been constructed with a multitude of architectural finishes. Careful attention to compliance with the standard architectural materials and finishes defined in Section 6.0 is critical. Additionally, architects and engineers must pay careful attention to compatibility with existing materials used when designing projects where an existing condition must be considered.
Landscaping and screening is also a critical element within District 3. Designers shall make every effort to provide visual barriers to undesirable elements through the means of masonry construction, fencing, and landscaping in accordance with the Robins AFB recommended plantings list.
The Weapons System Support Center, B/301, is a 1992 Air Force Design Award winner and is a focal point for successful renovation of an existing facility. Similar projects should strive to emulate this quality of design while taking into consideration consistency with the Base Architectural Compatibility Standards.
DISTRICT 4 – Housing
District 4 is comprised of 807 military family housing (MFH) units found at various locations throughout the base.
2.4 Housing
The various segments of District 4 are comprised of General Officers’ Quarters (GOQ), Field
Grade Officer Quarters, Company Grade Officer Quarters, and Enlisted military family housing units. These housing types are generally found in neighborhoods throughout the base.
For the most part, MFH units are typically brick with trim painted in a variety of accent colors.
All existing MFH facilities with non-white paint applications shall use the base paint standards found in Section 6.0 when future painting is required.
Those military family housing units in District 4 that are considered historical, as well as those facilities near the Officers Club, will be painted white.
3.0 Historic Preservation
Robins AFB and the Air Force Materiel Command are dedicated to complying with all federal legislation pertaining to the preservation of historic facilities. Careful coordination between the base and the State Historic Preservation Officer (SHPO) is essential.
3.1 Aging Facilities
All facilities 50 years of more must be considered as candidates for the National Register of Historic Places.
Examples of Robins AFB facilities considered for historic preservation are Building 220 (HQ
AFRC), Building 110 (Base Ops), and Building 125 (Depot Maintenance Hangar), and all General Officers’ Quarters (GOQs).
3.2 Base Historic Preservation Officer (BHPO)
Environmental Management (WR-ALC/EM) is responsible for assigning an individual to coordinate all historic preservation issues with the State of Georgia, 78 CEG/CE, and all appropriate using agencies.
All potential candidates for the National Register of Historic Places at Robins AFB shall be determined by the BHPO and approved by the SHPO.
3.3 State Historic Preservation Officer (SHPO)
Throughout the state of Georgia, The State Historic Preservation Officer (SHPO) is responsible for validating candidates for the National Register of Historic Places. The SHPO is the sole authority in the approval of candidates for the National Register of Historic Places.
Once a facility has been identified as a potential candidate, or actually placed on the National
Register, all potential designs to maintain, repair, or alter the facility in any way whatsoever must be approved by the SHPO.
Design documents for potential construction projects must be sent to the SHPO for approval.
The state of Georgia has thirty days to approve or deny proposed construction projects.
4.0 Handicapped Accessibility
Robins AFB is dedicated to providing adequate handicapped accessibility in all facilities basewide. All accessibility issues shall conform to the codes and guidance provided by the Uniform Federal Accessibility Standards (UFAS) or the Americans with Disabilities Act (ADA) which ever is more restrictive. Both maintenance-repair and new construction projects must be carefully reviewed to assure compliance with these standards.
4.1 Uniform Federal Accessibility Standards (UFAS)
The UFAS and the ADA are the applicable standards pertaining to handicapped accessibility in facilities at Robins AFB. The UFAS standardizes handicapped accessibility requirements in all DOD facilities.
The UFAS and ADA documents present uniform standards for the design, construction, and alternation of buildings so that physically handicapped persons will have ready access to them and use of them.
4.2 Maintenance and Repair
If existing elements, spaces, essential features, or common areas are altered, then each such altered element, space, feature, or area shall comply with the applicable provisions of the ADA.
To the maximum extent possible, handicapped accessibility should be included in design, with the exception of some test areas where only able-bodied civilians can work.
4.3 Military Exclusions
As a goal, Robins AFB will strive to provide adequate accessibility to all facilities regardless of the military exclusions granted by the USAS in Section 4.1.4.
5.0 Base Comprehensive planning
Careful and proper planning is critical to successful architectural compatibility.
5.1 Facility Siting
Proper facility sitting in accordance with the Robins AFB land use plan is critical to ensure that every effort is made to avoid incompatible land usage. Through the base’s Facility Board, the Air Logistics Center Commander will approve all sitting requests for new construction.
5.2 Area Development Plans (ADP)
When proposed construction requires planning beyond the limits of a single facility, designers should pursue the creation of area development plans in order to facilitate thoughtful planning of the relationship facilities have with one another.
5.3 Air Installation Compatibility Use Zone (AICUZ)
The Robins AFB study provides an assessment of noise levels, and statistical analysis to determine aircraft Accident Potential Zones (APZ). The goal of the study is to provide protection of the public and compatible development adjacent to the airfield.
Designers shall pay careful attention to the noise contours of the study to provide protection of the public and compatible development adjacent to the airfield.
5.4 Joint Land Use Study (JLUS)
Robins AFB’s relationship with the surrounding communities outside the base limits cannot be overlooked. This study provides a comprehensive assessment of the compatibility of the base’s land use and its positive or adverse impact on adjacent communities in central Georgia.
5.5 The Base Comprehensive Plan
The Base Comprehensive Plan is on the Robins AFB Web at www.gis.robins.af.mil. The plan features detailed narratives and figures (maps). There are four primary categories: (1) Constraints and Opportunities; (2) Land use; (3) Infrastructure; and (4) Capital Improvements.
New projects should be compatible with the comprehensive plan.
6.0 Architectural Finishes
Careful and consistent selection of construction materials and finishes is the most critical element of architectural compatibility.
6.1 Metal and Plastic
Metal siding is used extensively in most hangar and industrial facility construction. All metals shall be factory-finished with the manufacturer’s standard paint colors to match the Robins AFB standard paint scheme as closely as possible.
Metal conduit and cables are often mounted on the sides of facilities. These shall be factory-finished with the manufacturer’s standard paint colors, or field-finished (minimum two covering coats), to match the Robins AFB standard paint scheme as closely as possible.
6.2 Concrete
Although precise concrete elements provide an acceptable accent to masonry construction, concrete should be avoided as an entire architectural finish.
6.3 Brick
Brick is the desired architectural finish throughout all non-Flightline districts at Robins AFB due to its low maintenance needs and durability. All bricks shall be laid in a running bond except accent elements.
Design basis for the Robins AFB standard brick is Red Mattex manufactured by Boral Bricks, Inc., Burns Division; or equal approved by the Base Architectural Compatibility Manager.
Designers shall give careful attention to matching both brick and mortar color for all maintenance and repair projects to assure compatibility with existing facilities.
Mortar color to be used with the standard Red Mattex should normally be gray. Colored mortar for accent purposes may be used if approved by the Architectural Compatibility manager.
http://www.gis.robins.af.mil/�
6.4 Concrete Masonry Unit(s) (CMU)
Concrete masonry units are an acceptable and common building material at Robins AFB.
Standard 8- by 12- by 16-inch CMUs shall be laid in a running bond and are acceptable with the following finishes:
Smooth
- Standard smooth-finished CMUs are also acceptable when specified to be painted in accordance with the base color scheme or when selected with the inherent color to match the design basis shown below.
Design basis for CMUs shall be Blue Circle, Williams Brothers, Inc., IVORY 7L, or equal approved by the Base Architectural Compatibility Manager. All mortar color shall match the CMU color.
6.5 Exterior Insulation Finish System (EIFS)
When compatible with the base standard colors, use of EIFS products such as Dryvit, Synergy, and Durock are acceptable to accents to masonry construction.
This product shall not be designed to grade. Brick wainscots provide a more desirable and durable alternative.
6.6 Paint
Industrial and Commercial: All painting shall conform to the following color standards.
Color Scheme 1 Base Color Contrast Color Accent Colors Highlight Color Robins 42 Robins 62 Robins 68
Robins 48 Devoe 1UM21A Garrison
Main Walls Downspouts Vents/Louvers
Standing Seam Roofs Meta Fascia Gutters Doors/Door Frames
Hangars Other Buildings Contrast Colors for Large Buildings Option for Small Doors Transformers
Handrails Lamp Posts
Exempt Buildings
300 301 541 542 545 547 551 552 553 557 560 591 593 594 595 Museum
Officers Club and Conference Center: Because of the historical nature at the Officer’s Club and the architectural style of it and the Conference Center, those facilities should be painted white.
Housing: Housing paint colors shall be a combination of these pastel and accent color combinations randomly dispersed throughout the units. The Turner Park housing units provide the best example of these standards. Historical houses and those adjacent to the Officer’s Club area are to be painted white to provide compatibility in this area.
Color Scheme 1
Siding Trim, Soffits, & Posts Louvers and Doors
SW-2079
Avenue Tan SW White SW-2259
Dense Forest
Color Scheme 2
SW-2074
Fence Post White SW-White SW-2301
Farmhouse BGY
I) Color Scheme 3
SW-2114
Gris
SW-White SW-2118 Gunmetal Grey
Color Scheme 4 Color scheme 4 is all white
7.0 Roofing
Roofing plays a significant role in the visual integrity of architectural compatibility at Robins AFB. Past maintenance problems with built-up roofing must be avoided. Careful attention must be paid to compliance with the current Air Force policy for sloped roof conversion.
7.1 USAF Sloped Roof Policy
HQ USAF has published policy directives for the conversion of flat roofs to sloped roofs. This policy authorizes conversion of built-up roofs to sloped roofs provided.
- The existing roof needs to be replaced due to its deteriorated condition.
- No functional space is added to the facility.
- The useful life of the facility exceeds the life of the roof system selected.
- The selection of the sloped roof system is justified as the most economical method based on a life-cycle economic analysis.
7.2 Built-Up Roofing (BUR)
BUR shall be avoided whenever possible in all forms of construction of new facilities.
In some instances of less significant application of BUR, such as in military family housing
(District 4), repair of the existing roof type is practical and acceptable under the Base Architectural Compatibility Standards. Also, existing industrial facilities may be reroofed with a BUR when metal roofs are not economical or practical.
7.3 Roof-Top Equipment
If at all possible, placement of roof-top mechanical and utility equipment shall be avoided.
However, if no other viable alternative exists, the designer shall consider concealment of this equipment through color or screening compatible with the existing facility.
7.4 Standing Seam Metal Roofs
The base standard of a dark bronze standing seam metal roof with a 3:12 slope is recommended for use as much as possible basewide and must be used throughout District 2. Lower sloped roofs may be used, depending on the application, with the approval of the project architect.
7.5 Low Slope Roofs
Light colored roofs provide significant heat radiation benefits in most situations. They should be considered by the designer in industrial areas and/or where the roof has limited or no visibility from the ground. Obtain approval from Base Architectural Compatibility manager.
8.0 Exterior Signage
Consistent, compatible signage throughout the base can serve as an excellent tool to visually tie together various built and natural environments. Every effort must be made to reduce unnecessary or outdated signs which provide visual clutter and serve only to adversely affect architectural compatibility efforts on this base.
8.1 Standard Facility Signs
Exterior facility signs at Robins AFB are the sole responsibility of the Base Sign Manager and the 78 CEG sign shop. The Robins AFB Sign Standards have been developed in accordance with UFC 3-120-01, Sign Standards. Types B1 and B2 are modified to replace the logo at the top with the building number.
TYPE B1 – Facility Sign (upper echelon)
TYPE B2 – Facility Sign (lower echelon)
TYPE B4 – Building Entry Sign
TYPE D2 – Directional Sign
Traffic Signs – Follow the Manual on Uniform Traffic Control Devices
8.2 Facility Identification
Given the approval of the Base Sign Manager and the Architectural Compatibility Manager, lettering will be allowed on the exterior of prominent facilities. Size, type, and color of lettering will be approved on a case by case basis.
8.3 Logos and Supergraphics
Painted logos and racing stripes are no longer acceptable. The Base Sign Manager will strive to reduce any existing supergraphics and self-help organizational logos.
8.4 Special Signs
Special Signs will be permitted for unique situations subject to the approval of the Base Architectural Compatibility Manager.
9.0 Traffic Considerations
Parking problems, curbing details, landscaping
9.1 Parking
Parking has traditionally been a problem at Robins AFB.
78 SPS is the authority for assigning reserved parking spaces. Requests for reserved parking should be submitted to them along with justification and organization point-of-contact.
Parking stall width should be determined by the use of the lot. For example, parking spaces for
BX or Commissary lots where drivers have to deal with packages should be wider than employee parking with low turnover. In general, spaces should not be smaller than 9 feet wide.
Handicapped parking spaces should match the required standard from the UFAS or the ADA, whichever is predominant.
9.2 Curbing Standards
78 CEG/CEZ has developed a Curbing Plan to improve the Base infrastructure.
Base standard is a 24-inch curb and gutter unless existing site conditions require compatibility with existing curb and gutter of a different size. Curbs should normally not be painted. In special circumstances, the curbs may be painted dark brown or yellow depending on the visibility requirements. Obtain approval from the architectural compatibility manager.
Curbing standards will conform to the handicapped accessibility requirements defined by
UFAS or the ADA, whichever is predominant.
10.0 Landscaping
Landscape themes include planting treatments, site elements, barriers and screening, pedestrian environments, and open space; all of which contribute to the environment and visual quality of Robins AFB.
10.1 Recommended Plantings
All landscape plantings shall conform to the list of Robins AFB Recommended Plantings. This list is available in the Base Facility Standards.
10.2 Site Elements
Consistency is the most critical factor in the selection of various site elements such as benches, trash receptacles, lighting fixtures, small shelters, and street furniture.
Designers shall pay considerable attention to maintaining compatibility with similar site elements within a particular architectural district on Robins AFB. When no true compatibility exists, the designer shall coordinate material selection with the Base Architectural Compatibility Manager.
When practical, a dark bronze anodized finish shall be selected for all site elements on base.
10.3 Fencing and Screening
Comprehensive screening considerations are a major element in strengthening the visual image of this base. Properly designed barriers dramatically improve the visual appearance of both facilities and the base as a whole.
Three screening types are acceptable to reduce visual clutter on this base. Consistency and durability are critical. Well-designed screens should not draw attention and shall be kept to a minimum. Screening shall be considered/incorporated into the design of facilities to address the following types of items: Dumpsters, exterior mechanical and electrical equipment, storage/service areas, etc.
Brick Fencing
- Selection of brick must be compatible with the standards defined in Section 6.0 of this document.
- Brick fencing may be solid
Brick Fence Brick fence to have limestone or exposed precast coping. Height not to exceed 7’-0”. All bricks shall be laid in a running bond.
- or a combination of brick and wrought iron.
Wrought Iron Fence & Gate Pacific style fencing. Hot dipped uniform zinc – Black.
Metal fencing
- Provide metal fencing in the “shadow box configuration.
- This is the preferred fencing method in all except special situations requiring brick.
Privacy Paneling blends with the surrounding environment or nearby buildings while providing privacy, security, and screening. Base color is Robins 48 in the Industrial Flightline and Robins 62 elsewhere.
Vinyl Fencing
- White vinyl fencing may be acceptable in residential applications.
Chain Link Fencing
- This type of fencing is only acceptable when required by security regulations. When required, screen with shrubbery. If not possible, provide fabric screening attached to the fence.
10.4 Bollards
Provide bollards where required to protect structures or equipment.
Bollard shall be 6” schedule 40 steel pipe filled with concrete. Color shall be Robins 48 with a
4” wide painted strip 4” from the top. The strip shall be Robins 68 with reflective beads incorporated into the point.
10.5 Gazebos
In the past, there has been a proliferation of gazebos erected on Robins Air Force Base without a coherent architectural style, color coordination and, in some cases, site approval. Uniform standards are needed to ensure these structures enhance our facilities rather than detract from them.
All gazebos erected on Robins Air Force Base must be approved by the Base Civil Engineer.
Requesters must submit to the Base Civil Engineer a proposed site plan layout showing the distance from existing buildings and concept drawings of the proposed gazebo for approval.
Requests should be submitted to 778 CES/CEZP.
Gazebos will be normally octagonal in shape, non-ornamental in style, and constructed of quality materials. The gazebo will be constructed of a premanufactured kit of cedar or aluminum. Aluminum will be prefinished anodized dark bronze and cedar will be stained.
The screen porch behind dormitory 792 is a good example of the application of painted aluminum in conjunction with wood decks.
11.0 Interior Design Standards
Well-coordinated, neutral color schemes hold up over longer periods of time. Good design extends beyond aesthetics to provide durability, acoustical and energy-saving value, as well as morale enhancement for the inhabitants.
The goal is to ensure interior appearance of each facility is based on carefully established professional design standards rather than arbitrary personal preferences.
AFMC Facility Quality Program
11.1 Interior Finishes
All permanent finishes (ceramic tile, counter tops, vinyl tile, etc. shall be neutral colors.
Brighter accent colors may be used only in small areas; trendy patterns and colors shall be avoided.
Ease of maintenance should be foremost in the selection of interior finishes. Patterned carpet hides soil and traffic paths; semi-gloss or egg-shell finish paints are washable; white or pastel shades should be used only in low traffic areas, etc. corner guards and chair rails should be used to protect wall coverings.
Type II commercial vinyl wall coverings are recommended for all areas. Neutral colors and textures are referred to patterns. Wall covering shall be used below a chair rail with paint above.
All suspended acoustical ceilings shall be a 2-foot by 2-foot grid and tile to reduce the possibility of sagging. Recessed grid with drop-edge tile shall be used as the standard.
11.2 Carpet
USAF carpet policy requires a minimum weight of 26 ounces, textured-level loop, and patterned (multi-colored and loop graphics) of 100 percent continuous filament nylon (Type 6 or 6.6), 25% recycled content nylon.
Cut pile or solid colors may be used for borders in executive offices or distinguished visitors’
(DV) suites only.
12.0 Self-Help Program
The 78 CEG Self-Help Store provides Military Family Housing customers with the resources necessary to complete consistent and successful in-house construction projects. The self-help program is dedicated to providing housing with professional materials in a timely manner with outstanding support to accomplish many types of construction projects.
12.1 Self-Help Store
The self-help store provides military family housing occupants with many resources for use with both interior and exterior construction projects.
Housing Occupants can purchase quality construction materials and various landscaping items to improve the residential areas within District 4 of Robins AFB. Furthermore, all customers can sign out tools at no expense.
13.0 Energy Conservation
Energy costs account for a significant portion of the Defense Budget. In light of this, the Department of Defense (DOD) has established rigorous energy cost reduction objectives for all subordinate agencies. Meeting these objectives requires the scrutiny of all elements of our operations to determine areas of potential improvement. Architectural design of energy-efficient facilities is one such area.
13.1 Base Energy Manager
In accordance with DOD objectives to reduce energy consumption, Robins AFB has assigned a Base Energy Manager to focus energy conservation efforts.
The Base Energy Manager is responsible for creating and implementing the various energy plans which follow
13.2 Energy Annex to the AFMC Energy Plan
This annex outlines the Robins AFB Energy Program, defines its objectives, and describes future alternatives. The energy program addresses goals and initiatives taken and proposed to reduce energy consumption and cost and to improve energy efficiency.
13.3 WR-ALC Energy Strategic Plan
This plan identifies specific action items recommended by the Base Energy Manager, which will reduce energy consumption over time. The plan pursues items over the short term (1 year), medium term (2 years), and long-range objectives over a 5-year period.
13.4 Heating and Cooling Policy
Heating and cooling are significant energy cost drivers for Robins AFB and the WR-ALC.
Heating and cooling costs account for approximately 25-30 percent of the WR-ALC $17 million energy bill. This plan describes objectives necessary to reduce energy costs attributed to heating and cooling.
13.5 Workplace Lighting Policy
Lighting plays a major role in the effective accomplishment of the WR-ALC mission. Without sufficient lighting, our productivity and quality of work suffers. On the other hand, excessive lighting, such as operating lights during non-duty hours, wastes our energy dollars. This policy addresses the present, with the objective of curbing waste, and the future, with the objective of improving lighting efficiency.
14.0 References
This document is intended to provide references to specific details critical to successful architectural compatibility at Robins AFB.
1.0 Executive Summary
- AFMC Facility Quality Program
- AFMC Commander’s Desktop Guide to Excellence in Base Operating Support (BOS)
2.0 Architectural Districts
- AFMC Facility Quality Program
- Architectural and Landscape…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .