C27 Updated 621-20-107 Drawings Part 1 of 3.pdf
PDF 19 MB Posted
- Solicitation number
- 36C24923R0030
About this file
This file provides details for a federal contract opportunity to renovate Building 200 at the James H. Quillen VAMC Mountain Home facility in Tennessee. The solicitation number is 36C24923R0030 to renovate the D Wing of Building 200 for an Isolation Ward. The opportunity type is a solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The solicitation seeks bids to complete Project #621-20-107, which involves renovating the D Wing of Building 200 to establish an Isolation Ward at the James H. Quillen VAMC Mountain Home medical center in Tennessee. No further details on pricing, response dates, or award timing are provided in this file.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S. FIRST
ST.
MRI
8"
8"
T R A
IL
O R
TO JCMC
(MED. CENTER)
TO
E
TS
U
SO
UT
HE
RN
R R
40 41
8"
6"
4"
6" 6"
4"
6" 4"
6"
6"
8"
12"12"
12"
12" 8"
6"
8"
6"
6" 6"
4" PVC
(2/99)ESG
CONST.
TRAILOR
(6/90)
8" PVC
(6/90)
8" PVC
5"N.H C.I.
(6/90)
(6/90) C.I.
5"N.H
12" 12" 12" 12"
6" 4" 4"
8" 8"
6"
6"
6" 6"
4"
4"
8"
15"
15"
6"
24"
24" 18"
15"
24"
24"
24"
8"
10" 15"
15"
15"
15"
C.O.
C.O.
6"
8" 8"
8"
8"
8"
6"
8"
8" 3"
BRUSH
CREE
K
LA
KE
D R.
E
AS
T
LAKE DR. WEST
DOGWOOD
AVE.
F
IF
T H
S T
MAPLE
AVE.
MEMORIAL AVE.
F O U R T H
S T . T H
IR
D
S T
MEMORIAL AVE.
MAPLE
AVE.
MAGNOLIA
AVE.
S E C O N D
S T
F
IR
ST
S T.
LAMONT
ST.
S
ID
N E Y
S T
DOGWOOD
AVE.
BROWNLOW
CI
RC
LE
LAKE
BRUSH
CREE
K
ASHE
AVE.
BRADFORD PEAR LANE
S. FIRST
ST.
PEA
CE
AVE
CEMETERY
M
AIN
T.
R D.
PEACE AVE.
S U N S E T
D R
FREEDOM RD.
CEMETERY
VI
CT
OR
Y
LN
SUNSET
DR.
FRE
EDO
M R D.
VICTORY LN.
JAMES H. QUILLEN VA MEDICAL CENTER
#621-20-107
DEPARTMENT OF VETERANS AFFAIRS
LAMONT AND VETERANS WAY,
MOUNTAIN HOME, TENNESSEE 37684
RENOVATE D-WING
FOR ISOLATION WARD
D R A W I N G L I S T
G E N E R A L N O T E S
A. THE CONTRACT DRAWINGS AND SPECIFICATIONS (INDICATED BY THE SAME PROJECT NUMBER) ARE COMPLEMENTARY. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.) OF ANY DISCREPANCIES FOUND DURING
BIDDING AND THROUGH CONSTRUCTION.
B. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN.
C. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE CONTRACTING OFFICER
REPRESENTATIVE.
D. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND
CONSTRUCTION.
E. THE CONTRACTOR SHALL MAINTAIN ACCESSIBLE EGRESS FOR THE DURATION OF THE PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK AND THE ROUTES MUST BE
RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF THE PROJECT.
F. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE C.O.R. FOR THE SCHEDULED TIME OF CONSTRUCTION ACTIVITIES. THE CONTRACTING OFFICER REPRESENTATIVE RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED SPACES.
G. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE SAFE’D TO ACHIEVE THE
REQUIRED FIRE RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH DAY.
H. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODES AND FEDERAL AUTHORITIES, RULES AND REGULATIONS.
I. THESE DOCUMENTS SHOW DESIGN INTENT WITH MINIMUM CONSTRUCTION REQUIREMENTS AND MINIMUM QUALITY OF WORK EXPECTED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR CONSTRUCTION
AND EXPECTED QUALITY.
J. ALL MATERIALS UTILIZED ON THIS PROJECT SHALL BE NEW UNLESS OTHERWISE NOTED TO BE SALVAGED AND REFURBISHED.
MATERIAL QUALITY SHALL MEET OR EXCEED APPLICABLE INDUSTRY STANDARDS.
K. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES EXACT SIZE AND LOCATION OF ROOF, WALL AND FLOOR OPENINGS SHALL
BE VERIFIED WITH CORRESPONDING CONTRACTING TRADES PRIOR TO CONSTRUCTION.
L. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.
M. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VARYING ALL REQUIRED ROUGH OPENINGS AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER AND C.O.R. PRIOR TO CONSTRUCTION.
N. WHERE EXISTING SURFACES ARE TO BE RE-FINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE ATTACHMENT OF NEW CONSTRUCTION, PREPARE EXISTING SURFACES AS NECESSARY TO RECEIVE THE NEW MATERIALS FOR A LEVEL AND SMOOTH
FINISH.
O. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES APPARATUSES IMPACTING NEW CONSTRUCTION. DETERMINE EXACT SIZE AND LOCATION OF PENETRATION WITHIN NEW CONSTRUCTION, TIGHTLY SEAL AND CAULK.
P. GENERAL CONTRACTOR SHALL HOST SUBMITTAL EXCHANGE SOFTWARE FOR THE DURATION OF THE PROJECT.
Q. ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE PLUS-OR-MINUS (+/-) UNLESS NOTED OTHERWISE. VERIFY IN FIELD AND
REPORT ANY DISCREPANCIES TO VA C.O.R. AND ARCHITECT.
PROPOSED FENCED AND
GRAVELED CONTRACTOR
LAYDOWN AREA
SOUTH F
IR
ST S
TREET
PROJECT LOCATION
BUILDING 200
CEMETERY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/4 /2
:3
:0
P
M
GI000
COVER SHEET
11/04/2022 ET TD
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
GENERAL
GI000 COVER SHEET
GI001 ABBREVIATIONS AND GENERAL DETAILS
GI002 PARTITION TYPES AND NOTES
GI101 CODE SUMMARY AND LIFE SAFETY PLAN
GI102 LIFE SAFETY
GI103 ICRA PLAN
GI104 ICRA CLASS III REQUIREMENTS
GI105 PHASING PLAN
STRUCTURAL
S501 STRUCTURAL DETAILS
ARCHITECTURAL
AD101 SECOND FLOOR DEMOLITION PLAN
AD141 SECOND FLOOR DEMOLITION CEILING PLAN
AE101 OVERALL SECOND FLOOR PLAN
AE111 PARTIAL ENLARGED SECOND FLOOR PLAN
AE112 PARTIAL ENLARGED SECOND FLOOR PLAN
AC141 SECOND FLOOR REFLECTED CEILING PLAN
AE150 ROOF PLAN
AE401 ENLARGED RESTROOM PLANS AND ELEVATIONS
AE402 CASEWORK ELEVATIONS
AE403 CASEWORK ELEVATIONS
AE404 NURSES STATION DETAILS
AE500 COLUMN DETAILS
AE501 COLUMN DETAILS
AE502 DETAILS
AE601 DOORS, WINDOWS, DETAILS, AND SCHEDULES
INTERIORS
AI101 SECOND FLOOR FINISH PLAN
AI601 FINISH SCHEDULE
AI602 FINISH IMAGES
AI603 FINISH IMAGES
AW101 SECOND FLOOR WAYFINDING
WP101 WALL PROTECTION PLAN
EQUIPMENT
QT101 D2 OVERALL EQUIPMENT PLAN
QT401 ENLARGED EQUIPMENT PLAN
QT402 ENLARGED EQUIPMENT PLAN
QT403 ENLARGED EQUIPMENT PLAN
FIRE ALARM
FA1.00 FIRE ALARM LEGEND AND NOTES
FAD2.02 SECOND FLOOR FIRE ALARM DEMOLITION PLAN
FA2.02 SECOND FLOOR FIRE ALARM NEW WORK PLAN
FIRE PROTECTION
FX1.00 FIRE PROTECTION LEGEND AND NOTES
FXD2.02 SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN
FX2.02 SECOND FLOOR FIRE PROTECTION NEW WORK PLAN
FX7.00 FIRE PROTECTION DETAILS
PLUMBING
P1.00 PLUMBING LEGEND AND NOTES
PD2.01 FIRST FLOOR PLUMBING DEMOLITION PLAN
PD2.02 SECOND FLOOR PLUMBING DEMOLITION PLAN
PD3.02 SECOND FLOOR MEDICAL GAS DEMOLITION PLAN
PD2.03 ROOF DEMOLITION PLUMBING PLAN
P2.01 FIRST FLOOR PLUMBING NEW WORK PLAN
P2.02A SECOND FLOOR PLUMBING NEW WORK PLAN - WATER
P2.02B SECOND FLOOR PLUMBING NEW WORK PLAN - SANITARY/STORM
P2.03 ROOF NEW WORK PLUMBING PLAN
P3.02 SECOND FLOOR MEDICAL GAS NEW WORK PLAN
P4.01 PLUMBING ENLARGED PLANS
P5.01 WATER RISER DIAGRAM - PART A
P5.02 WATER RISER DIAGRAM - PART B
P5.03 SANITARY RISER DIAGRAM - PART A
P5.04 SANITARY RISER DIAGRAM - PART B
P6.01 PLUMBING DETAILS
MECHANICAL
M1.00 MECHANICAL LEGEND AND NOTES
MD2.02 SECOND FLOOR HVAC DEMOLITION PLAN
MD3.02 SECOND FLOOR HVAC PIPING DEMOLITION PLAN
M2.02 SECOND FLOOR HVAC NEW WORK PLAN
M3.02 SECOND FLOOR HVAC PIPING NEW WORK PLAN
M2.03 ROOF HVAC NEW WORK PLAN
M3.03 ROOF HVAC PIPING NEW WORK PLAN
M4.00 MECHANICAL SECTION VIEWS
M5.00 MECHANICAL DETAILS
M5.01 MECHANICAL DETAILS
M5.02 MECHANICAL DETAILS
M5.03 MECHANICAL DETAILS
M5.04 MECHANICAL DETAILS
M6.00 MECHANICAL SCHEDULES
M6.01 MECHANICAL SCHEDULES
M6.02 MECHANICAL SCHEDULES
M6.03 MECHANICAL SCHEDULES
M7.00 MECHANICAL CONTROLS
M7.01 MECHANICAL CONTROLS
ELECTRICAL
E1.00 ELECTRICAL LEGEND AND NOTES
E1.01 ELECTRICAL LIGHTING SCHEDULES
ED2.02 SECOND FLOOR POWER DEMOLITION PLAN
ED3.02 SECOND FLOOR LIGHTING DEMOLITION PLAN
E2.02 SECOND FLOOR POWER NEW WORK PLAN
E2.03 ROOF POWER NEW WORK PLAN
E3.02 SECOND FLOOR LIGHTING NEW WORK PLAN
E4.02 SECOND FLOOR HVAC POWER NEW WORK PLAN
E5.00 ELECTRICAL DETAILS
E6.00 ELECTRICAL ONE-LINE DIAGRAM AND WIRING GIUDELINES
E6.01 ELECTRICAL PANEL SCHEDULES
E6.02 ELECTRICAL PANEL SCHEDULES
TELECOMMUNICATION
T1.00 TECHNOLOGY LEGEND
TD2.02 SECOND FLOOR COMM DEMO PLAN
T2.02 SECOND FLOOR COMM NEW WORK PLAN
T3.02 SECOND FLOOR LOW VOLTAGE NEW WORK PLAN
T5.0 OIT TECHNOLOGY ENLARGED PLANS
T5.1 BIOMED TECHNOLOGY ENLARGED PLANS
T6.0 TECHNOLOGY RISER DIAGRAM
T7.0 TECHNOLOGY DETAILS
T7.1 TECHNOLOGY DETAILS
Grand total: 97
N
KEY PLAN
NTS
N
BUILDING 200
NTS
PROPOSED CONTRACTOR LAYDOWN AREA
NTS
CAMPUS MAP
NTS
VICINITY MAP
D WING
PROJECT LOCATION
N
N
No. Revisions: Date:
BID DOCUMENTS 11/04/2022
ffe-s Snapshot
MIN
1'-3"
C
LR
K N
E E
S P
A C
E
2' -3
M
IN
M A
X T
O R
IM
2' -1
0"
R E
F
LE
C T
E D
S U
R F
A C
E O
F M
IR
R
O R
3' -4
M
A X
T O
B O
MIRROR - VERIFY SIZE WITH
PLANS AND ELEVATIONS
MIN
8" DEEP
T O
R
IM
2' -1
0" M
A X
2'-1" MAX
1'-5" MIN
9" M
IN
9" M
IN
SIDE VIEW FRONT VIEW
CLEARANCE
6" MAX TOE
1'-5" MIN
LAVATORY
PLUMBING LINES
WITHIN HATCHED
AREA REQUIRED
TO BE INSULATED
LINES OF REQUIRED
CLEARANCE
FINISH FLOOR
4'-0" MIN CLR
2' -5
M
IN
5"
2' -3
M
IN
CLEAR SPACE
ALLOWABLE FOR
ACCESSIBILITY
MIRROR
2' -5
M
IN
LINES OF REQUIRED
CLEARANCE
5"
MAX
1'-0" 3'-6" MIN
1' -7
M
A X
T O
S E
A T
1' -5
M
IN
T O
O U
T
LE
T O
F D
IS
P
E N
S E
R
1' -3
M
IN
T
O
'-0
M A
X A
F F
3' -0
M
A X
T O
B A
R
2' -9
M
IN
9" MAX
7" MIN
GRAB BAR
1"
SANITARY NAPKIN
DISPOSAL AT WOMEN OR
UNISEX, SUGGESTED
LOCATION
GRAB BAR
3' -0
M
A X
T O
B A
R
2' -9
M
IN
1'-6" MAX
1'-4" MIN
SANITARY NAPKIN DISPOSAL AT
WOMEN OR UNISEX, SUGGESTED
LOCATION
1 1/2"
3'-0" MIN
6" MAX
2'-0" MIN 1'-0" MIN.
3'-0" MAX
3' -5
M
A X
3' -3
M
IN
1'
-6
M
IN
3'-5" MAX
3'-3" MIN VERTICAL GRAB BAR
TOILET PAPER
DISPENSER
4'-6" MIN
3' -5
M
A X
3' -3
M
IN
1'
-6
M
IN
SIDE WALL REAR WALL
VERTICAL GRAB BAR
FLOOR CLEARANCE
5'-0"
(4) 3/8" ANCHOR BOLTS
2'
O P
E R
A T
IN
G
M E
C H
A N
IS
M
M A
X T
O
POSTURE MIRRORPAPER TOWEL
DISPENSER WALL MTD
GARMENT HOOK SOAP DISH
RECESS
SANITARY NAPKIN
DISPOSAL
(WOMEN'S ONLY)
COMBINATION PAPER TOWEL
DISPENSER / WASTE RECEPTACLE
T O
C O
IN
S
L O
T
SANITARY NAPKIN/
TAMPON VENDOR
(WOMEN'S ONLY)
D
IS
P E
N S
E R
S L
O T
TOILET SEAT
COVER DISPENSER
6' -6
SHOWER CURTAIN ROD
T O
B O
T T
O M
M
A X
SOAP DISH
U F
C G
U
ID
E L
IN
E
DIAPER CHANGING
STATION
TOWEL BAR
TOWEL PIN
M
A X
M
IN
HAND DRYER
HAND HELD
SHOWER
SHOWER HEAD
MIN 59"
LONG HOSE
U F
C G
U
ID
E L
IN
E
M
A X
M
IN
M
A X
M
IN
M A
X A
F F
A
B O
V E
S
IN
K T
O B
/O R
E F
L S
U R
F A
C E
MIRROR TOILET PAPER
DISPENSER
M
A X
M
INVARIES FROM 3'-4" HEIGHT
FOR MAX 6" DEPTH, TO
4'-0" HEIGHT FOR MAX 1/2"
DEPTH
VARIES FROM 3'-0" HEIGHT
FOR MAX 9" DEPTH, TO
4'-0" HEIGHT FOR MAX 1/2"
DEPTH
CENTER OF OPERATING
MECHANISM
1' - 3 3/16"
4' -0
M
IN
2'-6" MIN
1' -5
M
IN
1' -7
M
A X
SINK
CLEAR FLOOR
SPACE
4' -0
M
IN
2'-6" MIN
5'-0"
4' -1
1" F
LO
O
R M
O U
N T
4' -8
W
A
LL
H U
N G
1'-6" MAX
1'-4" MIN
1' -5
M
IN
1' -7
M
A X
WATER CLOSET
SINK
CLEAR FLOOR
SPACE5'-0"
4' -1
1" F
LO
O
R M
O U
N T
4' -8
W
A
LL
H U
N G
1'-6" MAX
1'-4" MIN
4'-0" MIN
2' -6
M
IN
1'-7" MAX
WATER CLOSET
SINK
CLEAR FLOOR SPACE
CLEARANCE AT WATER CLOSET CLEARANCE AT WATER CLOSET
CLEARANCE AT SINK
5'-6" TURNING RADIUS
5'-0"
CLEARANCE AT SHOWER
MIN.
3'-0"
WATER CLOSET
A B B R E V I A T I O N S
A.B. ANCHOR BOLT
A.C.M. ASBESTOS CONTAINING MATERIALS
A.C.P. ASPHALT CONCRETE PAVING
A/C AIR CONDITIONING
ACOUS. ACOUSTIC
A.C.T. ACOUSTICAL CEILING TILE
A.D. AREA DRAIN
ADJ. ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGG. AGGREGATE
AL. ALUMINUM
ALT. ALTERNATE
APPROX. APPROXIMATE
ARCH. ARCHITECT
ASPH. ASPHALT
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
BM. BENCH MARK OR BEAM
BOT. BOTTOM
BRG. BEARING
BRK. BRICK
BRZ. BRONZE
BTWN. BETWEEN
B.U.R BUILT-UP ROOFING
CAB. CABINET
CARP. CARPET
C.B. CATCH BASIN
C.B.B. CEMENTITIOUS BACKER BOARD
CEM. CEMENT
CER. CERAMIC
CER.T. CERAMIC TILE
C.F.C.I. CONTRACTOR
FURNISH/CONTRACTOR INSTAL
C.F.O.I. CONTRACTOR FURNISH/OWNER
INSTALL
C.HK. COAT HOOK
C.I. CAST IRON
CIR. CIRCLE
C.J. CONSTRUCTION JOINT
CLG. CEILING
CLG.J. CEILING JOINT
CLKG. CAULKING
CLO. CLOSET
CLR. CLEAR
CLS. CLOSURE
CMU CONCRETE MASONRY UNIT
CNTR. COUNTER
C.O. CLEAN OUT
COL. COLUMN
COMB. COMBINATION
COMP. COMPOSITION
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONV.O. CONVECTION OVEN
C.O.R. CONTRACTING OFFICER'S
REPRESENTATIVE
CTR. CENTER
C.W. COLD WATER
CW. CURTAINWALL
DET. DETAIL
DF. DOUGLAS FIR
D.F. DRINKING FOUNTAIN
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DISP. DISPOSAL
DIV. DIVISION
DN. DOWN
D.O. DOOR OPENING
DR. DOOR
D.S. DOWN SPOUT
D.T. DRAIN TILE
D.W. DISHWASHER
DWG(S). DRAWING(S)
DWR. DRAWER
(E) EXISTING
EA. EACH
E.C. ELECTRICAL CONTRACTOR
E.E. EACH END
E.F. EXHAUST FAN
E.J. EXPANSION JOINT
ELEC. ELECTRICAL
ELEV. ELEVATION
E.N. EDGE NAIL
ENCL. ENCLOSURE
EQUIV. EQUIVALENT
E.S. EACH SIDE
E.W. EACH WAY
E.W.C. ELECTRICAL WATER CLOSET
EXP. EXPANSION
EXP.B. EXPANSION BOLT
EXPO. EXPOSURE
EXT. EXTERIOR
F. FACE
F.A. FIRE ALARM
F.B. FACE BRICK
F.BD. FIRE BOARD
F.BELL FIRE BELL
F.B.O. FURNISHED BY OTHERS
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.F. FINISH FLOOR
F.G. FINISH GRADE
FGL. FIBERGLASS
F.H. FIRE HYDRANT
FH.M.S. FLAT HEAD MACHINE SCREW
FIN. FINISH
FIXT. FIXTURE
F.J. FLOOR JOIST
F.L. FLOOR LINE
FLASH FLASHING
FLOUR FLUORESCENT
FLR. FLOOR
F.N. FACE NAIL
F.O.B. FACE OF BUILDING
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.M. FACE OF MASONRY
F.O.S. FACE OF STUD
F.R.T.W. FIRE RETARDANT TREATED WOOD
F.S.C. FIRE SUPPRESSION CONTRACTOR
F.S.E.C. FOOD SERVICE EQUIPMENT
CONTRACTOR
FTG. FOOTING
FUT. FUTURE
F.V.C. FIRE VAULT CABINET
GA. GAUGE
GALV. GALVANIZED
G.C. GENERAL CONTRACTOR
G.B. GRAB BAR
G.D. GARBAGE DISPOSAL
G.E. GRATE ELEVATION
G.I. GALVANIZED IRON
GL. GLASS
GLB. GLUE LAMINATED BEAM
GND. GROUND
GR. GRADE
G.S.M. GALVANIZED SHEET METAL
GYP.BD. GYPSUM BOARD
H.B. HOSE BIB
HC. HANDICAPPED
HDR. HEADER
HDWD. HARDWOOD
HDWE. HARDWARE
HGT. HEIGHT
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
H.P. HIGH POINT
HR. HOUR
H.S.S. HOLLOW STRUCTURAL STEEL
HTG. HEATING
H.V.A.C. HEATING, VENTILATION & AIR
CONDITIONING
H.W. HOT WATER
I.D. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
INV. INVERT
JAN. JANITOR
J.H. JOIST HANGER
JST. JOIST HANGER
JT. JOINT
KIT. KINTCHEN
LAB LABORATORY
LAM. LAMINATE
LAV. LAVATORY
L.B. LAG BOLT
L.H. LEFT HAND
L.L. LIVE LOAD
L.P. LOW POINT
LT. LIGHT
MAT. MATERIAL
MAX. MAXIMUM
M.B. MACHINE BOLT
M.C. MEDICINE CABINET
MECH. MECHANICAL
MED. MEDIUM
MEMB. MEMBRANE
M.E.P. MECHANICAL, ELECTRICAL,
PLUMBING
MFG. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MOD. MODULAR
MP.H. MOP HOLDER
MR. FRAMED MIRROR
M.R. MOISTURE RESISTANT
M.T. METAL THRESHOLD
MTD. MOUNTED
MTL. METAL
(N) NEW
N. NORTH
NAT. NATURAL
N.I.C. NOT IN CONTRACT
(NOT PART OF OSA APPROVAL)
NO. NUMBER
NOM. NOMINAL
NON/COM NON-COMBUSTIBLE
N.T.S. NOT TO SCALE
O/ OVER
O.A. OVERALL
OBS. OBSCURE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OVERFLOW
OFF. OFFICE
O.F.S. OUTSIDE FACE OF STUD
O.H.W.S. OVAL HEAD WOOD SCREW
OPP. OPPOSITE
P. PAINT
P.C. PLUMBING CONTRACTOR
P.C.F. POUNDS PER CUBIC FOOT
P.E.N. PANEL EDGE NAILING
PERF. PERFORATED
PL. PLATE
P.LAM PLASTIC LAMINATE
PLAS. PLASTER
P.L.F. POUNDS PER LINEAR FOOT
PLYWD. PLYWOOD
P.M.F. PRESSED METAL FRAME
PR. PAIR
PROP. PROPERTY
P.S.F. POUNDS PER SQUARE FOOT
P.S.I. POUNDS PER SQUARE INCH
P.STA. PULL STATION
PTD. PAINTED
P.T.D. PAPER TOWEL DISPENSER
PT. POINT
P.T.D.F. PRESSURE TREATED DOUGLAS
FIR
PTN. PARTITION
P.T.R. PAPER TOWEL RECEPTACLE
P.V.C. POLYVINYL-CHLORIDE
Q.T. QUARRY TILE
RAD. RADIUS
R.B. RUBBER BASE
R.C.P. REFLECTED CEILING PLAN
R.D. ROOF DRAIN
RDWD. REDWOOD
REF. REFERENCE
REFR. REFRIGERATOR
REINF. REINFORCING
REQD. REQUIRED
RESIL. RESILIENT
R.H. ROOF HATCH
R.HK. ROBE HOOK
R.H.M.S. ROUND HEAD METAL SCREW
R.H.W.S. ROUND HEAD WOOD SCREW
RM. ROOM
R.O. ROUGH OPENING
R.W.L. RAIN WATER LEADER
S. SOUTH
S.A.B. SOUND ATTENUATION BATT
S.A.D. SEE ARCHITECTURAL DRAWINGS
S.A.F.F. SELF ADHERED FLEXIBLE FLASHING
S.A.S.M. SELF ADHERED FLEXIBLE MEMBRANE
S.BLKG. SOLID BLOCKING
SCWD. SOLID CORE WOOD DOOR
S.C.D. SEE CIVIL DRAWINGS
S.D. STORM DRAIN
S.DISP. SOAP DISPENSER
SEAL. SEALANT
SECT. SECTION
S.E.D. SEE ELECTRICAL DRAWINGS
SHR. SHOWER
SHT. SHEET
SHTG. SHEATHING
SIM. SIMILAR
SL. SLIDING
S.L.D. SEE LANDSCAPE DRAWINGS
S.M.D. SEE MECHANICAL DRAWINGS
S.N.D. SANITARY NAPKIN DISPOSAL
S.N.V. SANITARY NAPKIN DISPENSER
S.P. SOUNDPROOF
SPEC. SPECIFICATION
SQ. SQUARE
SQ.FT. SQUARE FOOT (FEET)
S.S. SANITARY SEWER
S.S.D. SEE STRUCTURAL DRAWINGS
STA. STATION
STD. STANDARD
STL. STEEL
S.STL. STAINLESS STEEL
STO. STORAGE
STRUC. STRUCTRUAL
SUSP. SUSPENDED
T.B. TACKBOARD
T&B. TOP AND BOTTOM
TEL. TELEPHONE
TEMP. TEMPERED
TER. TERRAZZO
T&G. TOUNGE AND GROOVE
THK. THICK
T.J. TOOL JOINT
T.N. TOE NAIL
T.O.C. TOP OF CURB
T.O.P TOP OF PAVEMENT
T.O.PL. TOP OF PLATE
T.O.S. TOP OF SEAT
T.O.W. TOP OF WALL
T.P.D. TOILET PAPER DISPENSER
T.S. TUBE STEEL
T.V. TELEVISION
TYP. TYPICAL
UNF. UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
UR. URINAL
U/S. UNDERSIDE
V.C.T. VINYL COMPOSITION TILE
VERT. VERTICAL
VEST. VESTIBULE
V.G. VERTICAL GRAIN
V.I.F. VERIFY IN FIELD
V.T. VINYL TILE
V.T.R. VENT TO ROOF
V.W.C. VINYL WALL COVERING
(VC) V.A. FURNISHED / CONTRACTOR
INSTALLED
(VV) V.A. FURNISHED AND INSTALLED
W. WEST
W/ WITH
W/IN WITHIN
W.C. WATER CLOSET
WD. WOOD
WDW. WINDOW
W.F. WATER COOLER
W.H. WATER HEATER
W/O WITHOUT
W.P. WATER PROOF
W.R. WATER RESISTANT
WT. WEIGHT
W.W.F. WELDED WIRE FABRIC
YD. YARD
P1
A101
SIM
A101
SIM
A101
SIM
A101
SIM
LEVEL NAME W/ ELEVATION
NEW GRID HEAD
CALL OUT HEAD W/ SHEET NUMBER
ROOM NAME W/ ROOM NUMBER, AREA
& OCCUPANCY
BUILDING SECTION NUMBER W/ SHEET
NUMBER
WALL SECTION NUMBER W/
SHEET NUMBER
DOOR NUMBER
WALL TAG
KEYNOTE
REVISION TAG
FINISH TAG
DETAIL SECTION NUMBER W/
SHEET NUMBER
NORTH ARROW
LEVEL
ELEVATION
150 SF
S Y M B O L S
N
WINDOW TAGA
0 EXISTING GRID HEAD
10'-0" CEILING HEIGHT TAG
ROOM NAME
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/4 /2
:3
:1
P
M
GI001
ABBREVIATIONS AND GENERAL
DETAILS
11/04/2022 ET TD
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
No. Revisions: Date:
BID DOCUMENTS 11/04/2022
CONTINUOUS SEALANT AT BOTH SIDES OF RUNNER (TOP & BOTTOM)
SCHEDULED BASE
CONTINUOUS METAL "C" RUNNER AND FASTENERS @ 16" O.C. MIN.
FULL HEIGHT SOUND ATTENUATION BLANKET
(1) LAYER GYPSUM BOARD ON EACH SIDE
EXISTING STRUCTURE ABOVE
CONTINUOUS DEEP LEG DEFLECTION TRACK FOR 1/2" STRUCTURE
DEFLECTION.
SCHEDULED CEILING
SECTION AT FLOOR
SECTION AT CEILING
CONTINUOUS OR ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK ON
BOTH SIDES OF PARTITION.
HOLD STUD 1/2" FROM TOP OF DEFLECTION TRACK, ATTACH GWB TO
STUDS ONLY AND ATTACH STUDS TO THE DEFLECTION TRACK.
TOP OF STRUCTURAL SLAB & SCHEDULED FLOOR FINISH
SECTION AT
STRUCTURE ABOVE
COLD FORMED STEEL FRAMING
BRACING AT 48" O.C. WITHIN THE TOP 12" OF WALL.
FIRESTOP SEALANT AT EACH SIDE OF PARTITION
TOP OF STRUCTURAL SLAB WITH SCHEDULED FLOOR FINISH
CONTINUOUS SEALANT AT RUNNER (TOP & BOTTOM)
SCHEDULED BASE AND WALL FINISH.
CONTINUOUS METAL "C" RUNNER AND FASTENERS @ 16" O.C. MIN.
COLD FORMED STEEL FRAMING
EXISTING STRUCTURE ABOVE
HOLD STUD 1/2" FROM TOP OF DEFLECTION TRACK, ATTACH GWB
TO STUDS ONLY AND ATTACH STUDS TO THE DEFLECTION TRACK.
CONTINUOUS DEEP LEG DEFLECTION TRACK
FOR 1/2" STRUCTURE DEFLECTION
SCHEDULED CEILING
FULL HEIGHT SOUND ATTENUATION BLANKET
(1) LAYER GYPSUM BOARD
SECTION AT FLOOR
SECTION AT CEILING
SECTION AT
STRUCTURE ABOVE
CONTINUOUS OR ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK
BRACING AT 48" O.C. WITHIN THE TOP 12" OF WALL.
FIRESTOP SEALANT AT EACH SIDE OF PARTITION
FIRESTOP SEALANT
SCHEDULED CEILING
COLD FORMED STEEL FURRING CHANNEL
SCHEDULED BASE
CONT. MTL "C" RUNNER AND FASTENERS @ 16" O.C. MIN.
1/2" GAP BETWEEN CHANNEL AND EXISTING STRUCTURE.
EXISTING STRUCTURE ABOVE
SECTION AT FLOOR
SECTION AT CEILING
SECTION AT
STRUCTURE ABOVE
(1) LAYER 5/8" GYPSUM BOARD
EXISTING STRUCTURE
TOP OF STRUCTURAL SLAB WITH SCHEDULED FLOOR FINISH
EXTEND CHANNEL TO STRUCTURE ABOVE
CONTINUOUS DEEP LEG DEFLECTION TRACK
FOR 1/2" STRUCTURE DEFLECTION
FIRESTOP SEALANT AT EACH SIDE OF PARTITION
G E N E R A L P A R T I T I O N N O T E S
A. PROVIDE TYPE "X" GYPSUM BOARD AT ALL WALLS AND PARTITIONS INDICATED TO BE FIRE RATED.
B. LABEL ALL FIRE RATED AND SMOKESTOP PARTITIONS ABOVE CEILING WITH PLAQUE OR STENCILED SIGN READING: "FIRE AND SMOKE BARRIER: SEAL AND PROTECT ALL OPENINGS. SIGN SHALL BE PLACED ON BOTH SIDES OF WALLS AT 6'-0" ON CENTER MAXIMUM, WITH AT LEAST ONE SIGN PER ROOM.
C. PROVIDE CONTINUOUS FIRE RATED SEALANT AT THE PERIMETER OF ALL FIRE RATED WALLS AND CHASES, INCLUDING THE TOP, BOTTOM AND SIDE EDGES ON
BOTH SIDES OF WALL.
D. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD
PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
E. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINTS OF GYPSUM BOARD
PANELS SHALL BE STAGGERED, TAPED AND SEALED.
F. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT OPPOSITE OF WALLS.
G. PROVIDE WALL REINFORCEMENT BETWEEN STUDS WHERE REQUIRED BY INSTALLATION OF MILLWORK AND/OR WALL HUNG EQUIPMENT.
H. PROVIDE 16 GAUGE OR HEAVIER COLD FORMED STEEL FRAMING AT ALL DOOR JAMBS AND HEADERS. PROVIDE DOUBLE STUD EXTENDED TO SLAB ABOVE ON
DOOR OPENINGS, AT ALL OUTSIDE CORNER, AND FREE END WALLS.
I. SEE PLANS, ELEVATIONS, AND DETAILS FOR ADDITIONAL INFORMATION REGARDING INTERIOR WALLS AND PARTITIONS.
J. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL WALL STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER REQUIREMENTS FOR MAXIMUM ALLOWED
HEIGHT AND DEFLECTION.
K. ALL WALLS ARE FULL HEIGHT TO STRUCTURE ABOVE.
CONTINUOUS SEALANT AT BOTH SIDES OF RUNNER (TOP & BOTTOM)
SCHEDULED BASE
CONTINUOUS METAL "C" RUNNER AND FASTENERS @ 16" O.C. MIN.
FULL HEIGHT MINERAL BATT INSULATION
(1) LAYER TYPE "X" GYPSUM BOARD ON EACH SIDE
EXISTING STRUCTURE ABOVE
CONTINUOUS DEEP LEG DEFLECTION TRACK FOR 1/2" STRUCTURE
DEFLECTION
SCHEDULED CEILING
SECTION AT FLOOR
SECTION AT CEILING
CONTINUOUS ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK ON BOTH
SIDES OF PARTITION.
HOLD STUD 1/2" FROM SLIP TRACK, ATTACH GWB TO STUDS ONLY AND
ATTACH STUDS TO THE SLIP TRACK
SCHEDULED FLOOR FINISH
SECTION AT
STRUCTURE ABOVE
COLD FORMED STEEL FRAMING
BRACING AT 48" O.C. WITHIN THE TOP 12" OF WALL.
FIRESTOP SEALANT AT EACH SIDE OF PARTITION
FIRESTOP SEALANT AT BOTH SIDES OF PARTITION CONTINUOUS SEALANT AT BOTH SIDES OF RUNNER (TOP & BOTTOM)
SCHEDULED BASE
CONTINUOUS METAL "C" RUNNER AND FASTENERS @ 16" O.C. MIN.
FULL HEIGHT MINERAL WOOL INSULATION
(1) LAYER TYPE "X" GYPSUM BOARD
EXISTING STRUCTURE ABOVE
CONTINUOUS DEEP LEG DEFLECTION TRACK FOR 1/2" STRUCTURE
DEFLECTION
SCHEDULED CEILING
SECTION AT FLOOR
SECTION AT CEILING
CONTINUOUS OR ACOUSTIC SEALANT IN ALL VOIDS ABOVE TRACK ON
BOTH SIDES OF PARTITION.
HOLD STUD 1/2" FROM SLIP TRACK, ATTACH GWB TO STUDS ONLY AND
ATTACH STUDS TO THE SLIP TRACK
SCHEDULED FLOOR FINISH
SECTION AT
STRUCTURE ABOVE
CH STUD - COLD FORMED STEEL FRAMING
(1) LAYER 1" GYPSUM LINER PANELS (UL TYPE SLX)
BRACING AT 48" O.C. WITHIN THE TOP 12" OF WALL.
FIRESTOP SEALANT AT EACH SIDE OF PARTITION
SHAFT SIDE OF
PARTITION
FIRESTOP SEALANT AT BOTH SIDES OF PARTITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/4 /2
:3
:1
P
M
GI002
PARTITION TYPES AND NOTES
11/04/2022 PQ TD
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
P. TYPICAL PARTITION
P.3 9 1/4" (1) 5/8" GYPSUM BOARD COLD FORMED STEEL (1) 5/8" GYPSUM BOARD 8" BATT 8" 20G 16" O.C. - - 46
P.2 7 1/4" (1) 5/8" GYPSUM BOARD COLD FORMED STEEL (1) 5/8" GYPSUM BOARD 6" BATT 6" 20G 16" O.C. - - 46
P.1 4 7/8" (1) 5/8" GYPSUM BOARD COLD FORMED STEEL (1) 5/8" GYPSUM BOARD 3 1/2" BATT 3 5/8" 20G 16" O.C. - - 44
NUMBER
WALL
THICKNESS
SUBSTRATE [1] CORE STRUCTURE SUBSTRATE [2] INSULATION / BATT
STUD
SIZE
STUD
GAUGE
STUD
SPACING
FIRE
RATING
UL STC
R. RATED PARTITION
F. FURR-OUT PARTITION
S.1 4 1/4" - COLD FORMED STEEL (1) 5/8" GYPSUM BOARD 3 1/2" BATT 3 5/8" 20G 16" O.C. - - -
NUMBER
WALL
THICKNESS
SUBSTRATE [1] CORE STRUCTURE SUBSTRATE [2] INSULATION / BATT
STUD
SIZE
STUD
GAUGE
STUD
SPACING
FIRE
RATING
UL STC
F.2 4 1/4" - COLD FORMED STEEL (1) 5/8" GYPSUM BOARD - 3 5/8" 20G 16" O.C. - - -
F.1 2 1/8" - COLD FORMED STEEL (1) 5/8" GYPSUM BOARD - 1 1/2" 20G 16" O.C. - - -
NUMBER
WALL
THICKNESS
SUBSTRATE [1] CORE STRUCTURE SUBSTRATE [2] INSULATION / BATT
STUD
SIZE
STUD
GAUGE
STUD
SPACING
FIRE
RATING
UL STC
S. SINGLE SIDED PARTITION
R.3 5 3/8"
(1) 5/8" TYPE "X"
GYPSUM BOARD
COLD FORMED STEEL
(1) 5/8" TYPE "X"
GYPSUM BOARD
3 1/2" BATT 3 5/8" 20G 24" O.C.
1HR
SMOKE
UL U419 52
R.1 5 3/8"
(1) 5/8" TYPE "X"
GYPSUM BOARD
COLD FORMED STEEL
(1) 5/8" TYPE "X"
GYPSUM BOARD
3 1/2" BATT 3 5/8" 20G 24" O.C. 1HR UL U419 52
NUMBER
WALL
THICKNESS
SUBSTRATE [1] CORE STRUCTURE SUBSTRATE [2] INSULATION / BATT
STUD
SIZE
STUD
GAUGE
STUD
SPACING
FIRE
RATING
UL STC
R.4 4 3/4"
(1) 1" TYPE "X"
GYPSUM BOARD
CH STUD
COLD FORMED STEEL
(1) 3/4" TYPE "X"
GYPSUM BOARD
3" MINERAL WOOL
INSULATION
4" 25G 24" O.C. 1HR
UL U415
SYSTEM C
NUMBER
WALL
THICKNESS
SUBSTRATE [1] CORE STRUCTURE SUBSTRATE [2] INSULATION / BATT
STUD
SIZE
STUD
GAUGE
STUD
SPACING
FIRE
RATING
UL STC
R. RATED PARTITION
A
A
ISO ROOM 1
D201B
ISO ROOM 2
D202B
ISO ROOM 3
D203B
ISO ROOM 4
D204B
ISO ROOM 5
D205B
ISO ROOM 6
D206B
ISO ROOM 7
D207B
ISO ROOM 8
D208B
ISO ROOM 9
D209B
ISO ROOM 10
D210B
ISO ROOM 11
D211B
ISO ROOM 12
D212B
TOILET
D201C
ANTEROOM
D201A
TOILET
D202C
ANTEROOM
D202A
TOILET
D204C
TOILET
D203C
ANTEROOM
D203A ANTEROOM
D204A ANTEROOM
D205A
TOILET
D205C
TOILET
D-206C
ANTEROOM
D206A
ANTEROOM
D207A
TOILET
D208C
TOILET
D207C
ANTEROOM
D208A
ANTEROOM
D209A
TOILET
D210C
TOILET
D209C
ANTEROOM
D210A
ANTEROOM
D211A
TOILET
D212C
TOILET
D211C
ANTEROOM
D212A
CHART
ALCOVE
D201D
CHART
ALCOVE
D203D
CHART
ALCOVE
D205D
CHART
ALCOVE
D207D
CHART
ALCOVE
D209D
CHART
ALCOVE
D211D
EQUIPMENT
D214
ELECTRICAL
D233
NOURISHMENT
D215
HUDDLE
D216
CLEAN
D219
LINEN
D220
SOILED
D221
NURSE
STATION
D223
OIT
D222
MED
D224
NURSE
MANAGER
D227
LAB ALCOVE
D226
STAIRS
S1
STAFF
TOILET
D230
LOUNGE
D228
CORRIDOR
D2C3
ALCOVE
D217
ALCOVE
D213
WOMEN'S
LOCKER
D231
MEN'S
LOCKER
D232
STORAGE
D229
X-RAY ALCOVE
D225
PATH OF TRAVEL TO EXIT ENCLOSURE - 85' < 200'
CORRIDOR
D2C4B
CONSULT
D234
BIOMED
D235
ELEVATOR
LOBBY
D2EL2
COMMON PATH OF TRAVEL - 97' < 100'
NOTE: ESCORTED EGRESS AT
THIS LOCATION. LOCKING
MECHANISM TO COMPLY
WITH NFPA 19.2.2.2.6
NOTE: ESCORTED EGRESS AT
THIS LOCATION. LOCKING
MECHANISM TO COMPLY
WITH NFPA 19.2.2.2.6
PATH OF TRAVEL TO EXIT
ENCLOSURE - 158' < 200'
P A
T H
O F
T R
A V
E L
T O
E X
IT
E
N C
LO
S
U R
E
6'
(E)
(P)
(P)
(P)
C O
M M
O N
P A
T H
O F
T R
A V
E L
PATH OF TRAVEL TO EXIT ENCLOSURE - 104' < 200'
L I F E S A F E T Y L E G E N D
1 HOUR FIRE BARRIER
HORIZONTAL EXIT PASSAGEWAYHE
EX EXIT
EP EXIT PASSAGEWAY
HAZARDOUS ROOM
NOT IN SCOPE
DIRECTIONAL EXIT SIGN
PROPOSED FIRE EXTINGUISHER
PATH OF TRAVEL
2 HOUR FIRE BARRIER
FAC FIRE ALARM CONTROL
1 HOUR FIRE/SMOKE BARRIER
WALL MOUNTED
DIRECTIONAL EXIT SIGN
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTHCARE CORRIDOR
EXISTING FIRE EXTINGUISHER
(P)
(E)
BUILDING 200
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/4 /2
:3
:2
P
M
GI101
CODE SUMMARY AND LIFE
SAFETY PLAN
11/04/2022 Checker Author
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
Project: Renovate D Wing for Isolation Ward Location: James H. Quillen VA Medical Center Project Number: 621 20 107
PROJECT SUMMARY:
LOCATED IN JAMES H. QUILLEN VAMC, THIS PROJECT CONSISTS OF DESIGN AND CONSTRUCTION OF AN ISOLATION WARD ON LEVEL D2 WING OF BUILDING 200 AT THE JAMES H. QUILLEN VA MEDICAL CENTER, MOUNTAIN HOME (JOHNSON CITY), TENNESSEE. THE PROJECT IS ANTICIPATED TO RENOVATE APPROXIMATELY 12,250 SQUARE FEET OF EXISTING ADMINISTRATION OFFICES INTO A 12 BED ISOLATION WARD. THE DESIGN WILL INCLUDE A NEW HVAC SYSTEM INCLUDING A ROOFTOP AIR HANDLING UNIT, CHILLER AND EXHAUST SYSTEM DEDICATED TO THE NEW ISOLATION WARD. EACH ROOM SHALL BE CAPABLE OF POSITIVE OR NEUTRAL PRESSURIZATION AS NEEDED. THE WORK INCLUDES DEMOLITION AND RECONSTRUCTION OF WALLS, DOORS, CEILINGS, CASEWORK, PLUMBING, SPRINKLERS, ELECTRICAL
AND DATA SYSTEMS.
BUILDING 200 IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA.
ASCE7-2016 SEISMIC DESIGN CATEGORY – D (RISK CATEGORY IV, SITE CLASS D)
2021 NFPA 101 LIFE SAFETY CODE REVIEW
AREA OF WORK:
BUILDING 200 D WING LEVEL 2 IS APPROXIMATELY 12,250 DGSF
CHAPTER 3 DEFINITIONS
3.3.32.2 SMOKE BARRIER. A CONTINUOUS MEMBRANE, OR A MEMBRANE WITH DISCONTINUITIES CREATED BY PROTECTED OPENINGS, WHERE SUCH MEMBRANE IS DESIGNED AND CONSTRUCTED TO RESTRICT THE MOVEMENT OF SMOKE.
CHAPTER 6 - CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENT
6.1.5 EXISTING HEALTHCARE OCCUPANCY (CHAPTER 19) – NO CHANGE
6.2.2 HAZARD CLASSIFICATION: ORDINARY - NO CHANGE
CHAPTER 7 - MEANS OF EGRESS:
7.3.1.2 OCCUPANT LOAD FACTOR (PROJECT AREA ONLY):
HEALTH CARE USE (INPATIENT TREATMENT DEPT.): 12,250 SF AT 240 SF / OCC. = 51 OCC.
NOTE: REFER TO 19.2.5.7.2.4 PATIENT CARE SLEEPING SUITE TRAVEL DISTANCE.
CHAPTER 8 - FEATURES OF FIRE PROTECTION: NO CHANGE
8.2.2.2 FIRE COMPARTMENTS SHALL BE FORMED WITH FIRE BARRIERS THAT COMPLY WITH SECTION 8.3.
8.2.2.4 DOOR ASSEMBLIES REQUIRED TO BE SMOKE LEAKAGE RATED IN ACCORDANCE WITH 8.2.2.4 DOOR ASSEMBLIES SHALL COMPLY
WITH THE FOLLOWING:
1. TESTED IN ACCORDANCE WITH UL 1784
2. AIR LEAKAGE RATE OF THE DOOR ASSEMBLE SHALL BE 3.0 CUBIC FT/MIN./SQUARE FEET OF DOOR OPENING AT 0.10 IN. WATER
COLUMN FOR BOTH THE AMBIENT AND ELEVATED TEMPERATURE TESTS
3. DOOR ASSEMBLIES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 105.
8.3.1.2 FIRE BARRIERS SHALL COMPLY WITH ONE OF THE FOLLOWING:
THE FIRE BARRIERS ARE CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL OR FROM ONE BARRIER TO ANOTHER, OR A COMBINATION THEREOF, INCLUDING CONTINUITY THROUGH ALL CONCEALED SPACES SUCH AS THOSE FOUND ABOVE A CEILING, INCLUDING
INTERSTITIAL SPACES.
THE FIRE BARRIERS ARE CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL OR FROM ONE BARRIER TO ANOTHER, AND FROM THE FLOOR TO THE BOTTOM OF THE INTERSTITIAL SPACE, PROVIDED THAT THE CONSTRUCTION ASSEMBLY FORMING THE BOTTOM OF THE INTERSTITIAL SPACE HAS A FIRE RESISTANCE RATING NOT LESS THAN THAT OF THE BARRIER.
8.4. SMOKE PARTITIONS
8.4.2. SMOKE PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE, THROUGH ANY CONCEALED SPACES, SUCH AS THOSE ABOVE SUSPENDED CEILINGS AND THROUGH INTERSTITIAL STRUCTURAL AND MECHANICAL
SPACES.
8.5.3. FIRE BARRIERS AS SMOKE BARRIERS
A FIRE BARRIER SHALL BE PERMITTED TO BE USED AS A SMOKE BARRIER, PROVIDED THAT IT MEETS THE REQUIREMENTS OF SECTION 8.5.
8.7. SPECIAL HAZARD PROTECTIONS
8.7.1.1 PROTECTION FROM ANY AREA HAVING A DEGREE OF HAZARD GREATER THAN THAT NORMAL TO THE GENERAL OCCUPANCY OF THE
BUILDING OR STRUCTURE SHALL BE PROVIDED BY ONE OF THE FOLLOWING MEANS:
(1) SEPARATING THE AREA FROM OTHER PARTS OF THE BUILDING WITH A FIRE BARRIER HAVING A FIRE RESISTANCE RATING OF NOT
LESS THAN 1 HOUR IN ACCORDANCE WITH SECTION 8.3 AND WITHOUT WINDOWS.
(2) PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING SYSTEMS IN ACCORDANCE WITH SECTION 9.7.
(3) APPLYING BOTH 8.7.1.1(1) AND 8.7.1.1.(2) WHERE THE HAZARD IS SEVERE OR WHERE OTHERWISE SPECIFIED IN CHAPTERS 11
THROUGH 43.
8.7.3.3 ALCOHOL BASED HAND RUB DISPENSERS. PERMITTED PROVIDED THEY MEET THE CRITERIA OF THIS SECTION.
CHAPTER 9 - BUILDING SERVICE AND FIRE PROTECTION EQUIPMENT: NO CHANGE
CHAPTER 10 - INTERIOR FINISH, CONTENTS, AND FURNISHINGS: NO CHANGE
10.2.3.1
INTERIOR WALL AND CEILING FINISH MATERIALS TESTED IN ACCORDANCE WITH NFPA 286.
10.2.3.1.1 INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE CLASSIFIED IN ACCORDANCE WITH NFPA 286 AND COMPLY WITH 10.2.3.2.
10.2.3.1.2 MATERIALS TESTED IN ACCORDANCE WITH 10.2.3.1.1 AND COMPLYING WITH 10.2.3.2 SHALL BE CONSIDERED ALSO TO COMPLY WITH THE
REQUIREMENTS OF CLASS A, CLASS B, OR CLASS C IN ACCORDANCE WITH 10.2.3.3
10.2.3.2 ACCEPTANCE CRITERIA FOR NFPA 286. THE INTERIOR FINISH SHALL COMPLY WITH THE FOLLOWING:
(1) DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD TO THE CEILING.
(2) THE FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITY OF THE SAMPLE ON ANY WALL OR CEILING.
(3) FLASHOVER, AS DESCRIBED IN NFPA 286, SHALL NOT OCCUR.
(4) THE PEAK HEAT RELEASE RATE THROUGHOUT THE TEST SHALL NOT EXCEED 800 KW.
(5) FOR NEW INSTALLATIONS, THE TOTAL SMOKE RELEASED THROUGH-OUT THE TEST SHALL NOT EXCEED 1000 M2.
10.2.3.3 WALL AND CEILING- CLASSIFICATIONS CHARACTERISTICS.
(1) CLASS A: FLAME SPREAD: 0-25; SMOKE DEV. : 0-450.
(2) CLASS B: FLAME SPREAD: 26-75; SMOKE DEV. : 0-450
(3) CLASS C: FLAME SPREAD: 76-200; SMOKE DEV. : 0-450
10.2.4.8 LOCKERS
10.2.4.8.1 COMBUSTIBLE LOCKERS. WHERE LOCKERS CONSTRUCTED OF COMBUSTIBLE MATERIALS OTHER THAN WOOD ARE USED, THE LOCKERS SHALL BE CONSIDERED INTERIOR FINISH AND SHALL COMPLY WITH 10.2.3 EXCEPT AS PERMITTED BY 10.2.4.8.2.
10.2.4.8.2 WOOD LOCKERS. LOCKERS CONSTRUCTED ENTIRELY OF WOOD AND OF NON-COMBUSTIBLE MATERIALS SHALL BE PERMITTED TO BE USED IN ANY LOCATION WHERE INTERIOR FINISH MATERIALS ARE REQUIRED TO MEET A CLASS C CLASSIFICATION IN ACCORDANCE
WITH 10.2.3.
10.2.8 AUTOMATIC SPRINKLERS
10.2.8.1 OTHER THAN AS REQUIRED IN 10.2.4 WHERE AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS INSTALLED IN ACCORDANCE WITH SECTION 9.7, CLASS C INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE PERMITTED IN ANY LOCATION WHERE CLASS B IS REQUIRED, AND CLASS B INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE PERMITTED IN ANY LOCATION WHERE CLASS A IS
REQUIRED.
10.2.8.2 WHERE AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS INSTALLED IN ACCORDANCE WITH SECTION 9.7, THROUGHOUT THE FIRE COMPARTMENT OR SMOKE COMPARTMENT CONTAINING THE INTERIOR FLOOR FINISH, CLASS II INTERIOR FLOOR FINISH SHALL BE PERMITTED IN ANY LOCATION WHERE CLASS I INTERIOR FINISH IS REQUIRED, AND WHERE CLASS II IS REQUIRED, THE PROVISIONS OF
10.2.7.2 SHALL APPLY.
CHAPTER 19 – EXISTING HEALTH CARE OCCUPANCIES: NO CHANGE
19.1.1.4.3.1 A MAJOR REHABILITATION SHALL INVOLVE THE MODIFICATION OF MORE THAN 4,500 SF GROSS OF THE AREA OF THE SMOKE COMPARTMENT. A MINOR REHABILITATION SHALL INVOLVE THE MODIFICATION OF NOT MORE THAN 50 PERCENT AND NOT MORE THAN
4,500 SF GROSS OF THE AREA OF THE SMOKE COMPARTMENT.
19.1.6.4 INTERIOR NON-BEARING WALLS IN BUILDINGS OF TYPE 1 OR 2 CONSTRUCTION SHALL BE CONSTRUCTED ON NONCOMBUSTIBLE OR
LIMITED COMBUSTIBLE MATERIALS UNLESS OTHERWISE PERMITTED BY 19.1.6.5.
19.2.2.2.10 SLIDING DOORS SHALL BE PERMITTED IN ACCORDANCE WITH 19.2.2.2.11 OR 19.2.2.2.11.2.
19.2.5.3 DEAD END CORRIDORS – EXISTING DEAD-END CORRIDORS NOT EXCEEDING 30 FEET SHALL BE PERMITTED.
19.2.5.7.2.3 PATIENT CARE SLEEPING SUITE MAXIMUM SIZE
(C) PATIENT CARE SLEEPING SUITE GREATER THAN 7,500 SF GROSS FLOOR AREA AND NOT EXCEEDING 10,000 SF GROSS FLOOR AREA
SHALL BE PERMITTED WHERE ALL OF THE FOLLOWING ARE PROVIDED IN THE SUITE:
(1) DIRECT VISUAL SUPERVISION IN ACCORDANCE WITH 19.2.5.7.2.1 (B) (1) (a)
(2) TOTAL (C0MPLETE) COVERAGE AUTOMATIC SMOKE DETECTION IN ACCORDANCE WITH 9.6.2.9 AND 19.3.4
(3) APPROVED ELECTRICALLY SUPERVISED SPRINKLER SYSTEM PROTECTION COMPLYING WITH 19.3.5.8.
19.2.5.7.2.4 PATIENT CARE SLEEPING SUITE TRAVEL DISTANCE.
(A) TRAVEL DISTANCE BETWEEN ANY POINT IN A SLEEPING SUITE AND AN EXIT ACCESS DOOR TO ANOTHER SUITE, AN EXIT ACCESS CORRIDOR DOOR, OR A HORIZONTAL EXIT DOOR FROM THAT SUITE SHALL NOT EXCEED 100 FT.
(B) TRAVEL DISTANCE BETWEEN ANY POINT IN A SLEEPING SUITE AND AN EXIT SHALL NOT EXCEED THE FOLLOWING:
(2) 200 FT IF THE BUILDING IS PROTECTED THROUGHOUT BY AN APPROVED ELECTRICALLY SUPERVISED SPRINKLER SYSTEM COMPLYING
WITH 19.3.5.7
NOTE: BUILDING 200 IS FULLY SPRINKLED.
19.2.6.2.3 THE TRAVEL DISTANCE BETWEEN ANY POINT IN A HEALTH CARE SLEEPING ROOM AND AN EXIT ACCESS DOOR IN THAT ROOM
SHALL NOT EXCEED 50 FT.
19.3.2 PROTECTION FROM HAZARDS.
19.3.2.1 HAZARDOUS AREAS. ANY HAZARDOUS AREAS SHALL BE SAFE GUARDED BY A FIRE BARRIER HAVING A 1 HOUR FIRE RESISTANCE RATING OR SHALL BE PROVIDED WITH AN AUTOMATIC EXTINGUISHING SYSTEM IN ACCORDANCE WITH 8.7.1.
19.3.2.1.3 THE DOORS SHALL BE SELF CLOSING OR AUTOMATIC CLOSING.
19.3.2.1.5 HAZARDOUS AREAS SHALL INCLUDE BUT SHALL NOT BE LIMITED TO THE FOLLOWING:
1. CENTRAL/BULK LAUNDRIES LARGER THAN 100 SF,
2. ROOMS WITH SOILED LINEN IN VOLUMES EXCEEDING 64 GAL.,
3. ROOMS WITH COLLECTED TRASH IN VOLUME EXCEEDING 64 GAL.,
4. ROOMS OR SPACES LARGER THAN 50 SF INCLUDING STORAGE OF COMBUSTIBLE SUPPLIES AND EQUIPMENT IN QUANTITIES
DEEMED HAZARDOUS BY THE AUTHORITY HAVING JURISDICTION.
19.3.3 INTERIOR FINISH
19.3.3.1 INTERIOR FINISH SHALL BE IN ACCORDANCE WITH SECTION 10.2
19.3.3.2 INTERIOR WALL AND CEILING FINISH MATERIALS COMPLYING WITH SECTION 10.2 SHALL BE PERMITTED TO BE CLASS A OR CLASS B.
19.3.3.3 INTERIOR FLOOR FINISH. NO RESTRICTIONS SHALL APPLY TO EXISTING FLOOR FINISH.
19.3.6.2 CONSTRUCTION OF CORRIDOR WALLS
19.3.6.2.1 CORRIDOR WALLS SHALL BE CONTINUOUS FROM FLOOR TO UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. THROUGH ANY CONCEALED SPACES SUCH AS THOSE ABOVE SUSPENDED CEILINGS, AND THROUGH INTERSTITIAL STRUCTURAL AND MECHANICAL
SPACES, UNLESS OTHERWISE PERMITTED BY 19.3.6.2.4 THROUGH 19.3.6.2.8
19.3.6.2.2 CORRIDOR WALLS SHALL HAVE A MINIMUM ½ HOUR FIRE RESISTANCE RATING.
19.3.6.2.3 CORRIDOR WALLS SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE.
19.5.4.3 ANY WASTE CHUTE OR LINEN CHUTE INCLUDING PNEUMATIC WASTE AND LINEN SYSTEM SHALL BE PROVIDED WITH AUTOMATIC
EXTINGUISHING PROTECTION IN ACCORDANCE WITH SECTION 9.7 (SEE SECTION 9.5).
CODE SUMMARY
N
1/16" = 1'-0"
BUILDING 200 LIFE SAFETY PLAN
N
NTS
KEYPLAN
BUILDING 200
P N M L K I H G F E C
35.1
D B.5 B A.5 A
30.1
32.8
O
ISO ROOM 1
D201B
ISO ROOM 2
D202B
ISO ROOM 3
D203B
ISO ROOM 4
D204B
ISO ROOM 5
D205B
ISO ROOM 6
D206B
ISO ROOM 7
D207B
ISO ROOM 8
D208B
ISO ROOM 9
D209B
ISO ROOM 10
D210B
ISO ROOM 11
D211B
ISO ROOM 12
D212B
TOILET
D201C
ANTEROOM
D201A
TOILET
D202C
ANTEROOM
D202A
TOILET
D204C
TOILET
D203C
ANTEROOM
D203A
ANTEROOM
D204A
ANTEROOM
D205A
TOILET
D205C
TOILET
D-206C
ANTEROOM
D206A
ANTEROOM
D207A
TOILET
D208C
TOILET
D207C
ANTEROOM
D208A
ANTEROOM
D209A
TOILET
D210C
TOILET
D209C
ANTEROOM
D210A
ANTEROOM
D211A
TOILET
D212C
TOILET
D211C
ANTEROOM
D212A
CHART ALCOVE
D201D
CHART ALCOVE
D203D
CHART ALCOVE
D205D
CHART ALCOVE
D207D
CHART ALCOVE
D209D
CHART ALCOVE
D211D
EQUIPMENT
D214
ELECTRICAL
D233
NOURISHMENT
D215 HUDDLE
D216
CLEAN
D219
LINEN
D220
SOILED
D221
NURSE STATION
D223
OIT
D222
MED
D224
NURSE MANAGER
D227
LAB ALCOVE
D226
BIOMED
D235
MECHANICAL
H.A.C.
STAIRS
S1
STAFF TOILET
D230
LOUNGE
D228
CORRIDOR
D2C3
RESTROOM
D218
ALCOVE
D217
ALCOVE
D213
WOMEN'S LOCKER
D231
MEN'S LOCKER
D232
STORAGE
D229
X-RAY ALCOVE
D225
PATH OF TRAVEL TO EXIT ENCLOSURE
85' < 200'
TRAVEL DISTANCE TO EXIT
(101' < 200')
PATIENT ROOM
D252
TOILET
D252ANURSING OFFICE
D247
HAC
D257SURGERY OFFICE
D259
DINING
D232
353 SF
CORRIDOR
D2C4B
172 SF
CORRIDOR
D2C5
275 SF
CORRIDOR
D2-C4A
276 SF
ELEVATOR LOBBY
D2EL2
265 SF
CORRIDOR
D2C2
71 SF
CORRIDOR
D2C3A
205 SF
CORRIDOR
D2C3B
82 SF
CONSULT
D234
66 SF
VESTIBULE
D236
FULLY SPRINKLED
NON SLEEPING
SUITE 735 SF
FULLY SPRINKLED
NON SLEEPING
SUITE 967 SF
FULLY SPRINKLED
SLEEPING SUITE
9,835 SF
(P)
(P)
(P)
(E)
9' - 6" 19' - 0" 1' - 8" 22' - 4" 22' - 6" 23' - 0" 22' - 6" 26' - 0" 26' - 0" 26' - 0" 10' - 0" 4' - 6" 10' - 3" 10' - 0" 10' - 0" 10' - 0"
1'
9'
9'
0"
6'
9'
9" 9'
C O
M M
O N
P A
T H
O F
T R
A V
E L
L I F E S A F E T Y L E G E N D
1 HOUR FIRE BARRIER HORIZONTAL EXIT PASSAGEWAYHE
EX EXIT
EP EXIT PASSAGEWAY
HAZARDOUS ROOM
EXIT STAIR OR PASSAGEWAY
DIRECTIONAL EXIT SIGN
FIRE EXTINGUISHER
PATH OF TRAVEL2 HOUR FIRE BARRIER FAC FIRE ALARM CONTROL
1 HOUR FIRE/SMOKE BARRIER
WALL MOUNTED
DIRECTIONAL EXIT SIGN
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTHCARE CORRIDOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/4 /2
:3
:5
P
M
GI102
LIFE SAFETY
11/04/2022 ET TD
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
N
NTS
KEYPLAN
N
1/8" = 1'-0"
PARTIAL SECOND FLOOR LIFE SAFETY PLAN
P N M L K I H G F E C
35.1
D B.5 B A.5 A
30.1
32.8
O
ISO ROOM 1
D201B
ISO ROOM 2
D202B
ISO ROOM 3
D203B
ISO ROOM 4
D204B
ISO ROOM 5
D205B
ISO ROOM 6
D206B
ISO ROOM 7
D207B
ISO ROOM 8
D208B
ISO ROOM 9
D209B
ISO ROOM 10
D210B
ISO ROOM 11
D211B
ISO ROOM 12
D212B
TOILET
D201C
ANTEROOM
D201A
TOILET
D202C
ANTEROOM
D202A
TOILET
D204C
TOILET
D203C
ANTEROOM
D203A
ANTEROOM
D204A
ANTEROOM
D205A
TOILET
D205C
TOILET
D-206C
ANTEROOM
D206A
ANTEROOM
D207A
TOILET
D208C
TOILET
D207C
ANTEROOM
D208A
ANTEROOM
D209A
TOILET
D210C
TOILET
D209C
ANTEROOM
D210A
ANTEROOM
D211A
TOILET
D212C
TOILET
D211C
ANTEROOM
D212A
CHART ALCOVE
D201D
CHART ALCOVE
D203D
CHART ALCOVE
D205D
CHART ALCOVE
D207D
CHART ALCOVE
D209D
CHART ALCOVE
D211D
EQUIPMENT
D214
ELECTRICAL
D233
NOURISHMENT
D215 HUDDLE
D216
CLEAN
D219
LINEN
D220
SOILED
D221
NURSE STATION
D223
OIT
D222
MED
D224 NURSE MANAGER
D227
LAB ALCOVE
D226
BIOMED
D235
MECHANICAL
H.A.C.
STAIRS
S1
STAFF TOILET
D230
LOUNGE
D228
CORRIDOR
D2C3
RESTROOM
D218
ALCOVE
D217
ALCOVE
D213
WOMEN'S LOCKER
D231
MEN'S LOCKER
D232
STORAGE
D229X-RAY ALCOVE
D225
CORRIDOR
D2C5
CORRIDOR
C6
CORRIDOR
D2C4B
CORRIDOR
D2C2
CORRIDOR
D2C1
CONSULT
D234
CORRIDOR
D2C3B
CORRIDOR
D2C3A
VESTIBULE
D236
9' - 6" 19' - 0" 1' - 8" 22' - 4" 22' - 6" 23' - 0" 22' - 6" 26' - 0" 26' - 0" 26' - 0" 10' - 0" 4' - 6" 10' - 3" 10' - 0" 10' - 0" 10' - 0"
1'
9'
9'
0"
6'
9'
9" 9'
CORRIDOR
D2-C4A
ELEVATOR LOBBY
D2EL2
BUILDING 200
I C R A L E G E N D
PROJECT SCOPE
NOT IN CONTRACT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/4 /2
:3
:5
P
M
GI103
ICRA PLAN
11/04/2022 ET NM
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
A. TEMPORARY PARTITIONS ARE TO BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS AND SHALL BE SMOKE AND DUST TIGHT. PARTITIONS SHALL EXTEND FROM THE FLOOR TO HARD CEILING OR DECK ABOVE. THEY ARE TO BE INSTALLED PRIOR TO START OF CONSTRUCTION.
B. DUST BARRIERS ARE REQUIRED IN ALL OCCUPIED AREAS IN ADDITION TO TEMPORARY PARTITIONS.
C. ALL AREAS UNDER CONSTRUCTION TO BE UNDER NEGATIVE AIRFLOW USING A NEGATIVE AIR MACHINE EXHAUSTING OUTSIDE.
D. PROVIDE NEGATIVE AIR MONITORING DEVICES OUTSIDE OF EACH CONSTRUCTION AREA DURING EACH CONSTRUCTION PHASE.
E. ISOLATE AND SEAL ALL OPENINGS IN DUCTS INTO CONSTRUCTION AREA FOR EACH PHASE PRIOR TO STARTING ANY NEW WORK IN NEXT
PHASE.
F. COORDINATE ANY WORK THAT WILL CREATE EXCESS VIBRATION OR NOISE TO AREAS SURROUNDING THE CONSTRUCTION AREA WITH VA
COR.
G. CONTRACTOR SHALL PROVIDE 24 HOUR FIRE WATCH DURING DOWN TIME OF FIRE PROTECTION SYSTEM.
H. REFER TO SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS FOR ADDITIONAL INFECTION CONTROL INFORMATION.
I. COORDINATE ALL WORK ASSOCIATED WITH THIS PROJECT FOLLOWING SITE SPECIFIC INFECTION CONTROL RISK ASSESSMENT AS PUBLISHED
BY THIS VAMC CAMPUS.
J. ANY DUST GENERATED FROM DEMOLITION OR CONSTRUCTION ACTIVITIES SHALL BE IMMEDIATELY CLEANED IF TRACKED OR FOUND OUTSIDE
OF THE CONSTRUCTION PHASING LIMITS/PERIMETERS.
K. CONTRACTOR PERSONNEL SHALL MONITOR DUST PARTITION CONDITION AND PERFORM MAINTENANCE DURING PHASED CONSTRUCTION ACTIVITIES. DUST PARTITIONS SHALL BE CAREFULLY REMOVED TO MINIMIZE THE SPREAD OF DUST.
L. CONTRACTOR SHALL INSTALL INTERIM PLASTIC DUST BARRIERS (MIN. 6 MIL THICKNESS) PRIOR TO THE REMOVAL OF DUST PARTITIONS.
M. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY PARTITION LAYOUT AS TO NOT TO IMPEDE CODE REQUIRED EXITING OR INTERFERE
WITH HOSPITAL OPERATIONS.
N. PHASED SITE ACCESS SHALL HAVE DEFINED ENTRY AND EXIT PROCEDURES, EGRESS PATHS AND BE FREE OF DEBRIS, TOOLS, EQUIPMENT OR
CONTAINERS.
O. INSTALL SIGNAGE TO DIRECT GENERAL PEDESTRIAN TRAFFIC AWAY FROM CONSTRUCTION AREAS.
N
1/8" = 1'-0"
PARTIAL SECOND FLOOR ICRA PLAN
N
NTS
KEYPLAN
G E N E R A L I N F E C T I O N C O N T R O L N O T E SD R A W I N G N O T E S
1 FULL HEIGHT ONE HOUR RATED TEMPORARY CONSTRUCTION PARTITION WITH 3'-0" X 7-0" 20 MIN. RATED ACCESS DOOR WHERE SHOWN. PAINT
TEMPORARY WALL AND PROVIDE WALL BASE.
2 PROVIDE TEMPORARY CONSTRUCTION SIGNAGE TO READ "DANGER - CONSTRUCTION AREA, AUTHORIZED PERSONNEL ONLY."
3 PROVIDE STICKY WALK OFF MATS AT ENTRANCE INTO CONSTRUCTION AREA.
A A
SUSPENDED PLASTIC ZIPPER WALL
CURTAIN BARRIER
POST ICRA, ILSM, FIRE INSPECTION SHEETS
VISIBLE TO PUBLIC
PROVIDE STICKY MATS (CHANGED END OF
SHIFT OR MORE IF NECESSARY TO MAINTAIN
CLEANLINESS)
INDICATOR MUST BE AT -0.01 OR GREATER (VERIFY DAILY).
IF NOT, VERIFY ALL OPENINGS, SUCH AS DOORS, ARE
CLOSED AND / OR CHANGE OUT NEGATIVE AIR PRE-FILTER
PROVIDE A 6'-0" x 4'-0" WALK OFF MAT
INSIDE OF WORK AREA (CHANGE
WHEN NECESSARY TO MAINTAIN
CLEANLINESS)
FIRE EXTINGUISHER ON PORTABLE
FLOOR BRACKET (ILSM MAY REQUIRE
MORE THAN ONE)
TAPE ALL SERVICES TO PROTECT
AGAINST CONTAMINATION
OPTIONAL EXHAUST DUCTS (COVER
THE GRATES AND THE DIFFUSERS)
SUPPLY DUCTS EITHER KEEP
RUNNING OR COVER WHEN
RUNNING TO KEEP DUST OUT
COVER ALL RETURNS AT THE
GRATE / DIFFUSERS
OUTSIDE OF BUILDING
E
A
O
V
MONTHLY CHANGED HEPA
FILTER
HEPA NEGATIVE AIR UNIT
WEEKLY CHANGED (OR
MORE AS NEEDED) PRE-
FILTER
FIRE RATED PLYWOOD (REFER TO
ELEVATION)
F
LE
X D
U C
T
FINISHED FLOORING TO BE KEPT CLEAN. FLOORS
NOT BEING REPLACED TO BE PROTECTED OR
COVERED WITH ROSEN PAPER / FIRE RATED
PLYWOOD
FIRE / U.L. RATED PLASTIC TO
PREVENT DUST INFILTRATION
(INSTALL PRIOR TO
CONSTRUCTION)
FIRE / U.L. RATED PLASTIC TO
PREVENT DUST INFILTRATION
(INSTALL PRIOR TO
CONSTRUCTION)
EXISTING FIRE
SPRINKLER SYSTEM
EXISTING WALLEXISTING WALL
EXISTING CONCRETE SLAB FLOORING
HEATED DETECTOR CUT-OFF
HEPA NEGATIVE AIR UNIT
FIRE RATED PLYWOOD
(TEMP. REMOVE GLASS
PANEL)
EXISTING WINDOW FRAME
POST ICRA, ILSM, FIRE
INSPECTION SHEETS VISIBLE
TO PUBLIC
SUSPENDED PLASTIC ZIPPER WALL
CURTAIN BARRIER
PLASTIC ZIPPER WALL NOT
ALLOWED FOR MORE THAN 48
HOURS. COORDINATE WITH COR
FOR SPECIFC REQUIREMENTS.
A P
P R
O X
. 4 8"
A .F
.F
INDICATOR MUST BE AT -0.01 OR GREATER (VERIFY
DAILY), IF NOT VERIFY ALL OPENINGS, SUCH AS DOORS,
ARE CLOSED AND/OR CHANGE OUT NEGATIVE AIR PRE-
FILTER.
INDICATOR (REFER TO PLAN
& ELEVATION)
C.O.R. CONTACT INFO
CONST. SUPERVISOR
NAME AND CELL
PHONE
CHILLER PLANT AFTER HOURS
CONTACT PHONE NUMBER FIRE
EMERGENCY DIAL 911
PERSONNEL ENTERING MUST HAVE: HARD HAT, SAFETY GLASSES
AND PROPER I.D.
THIS IS A
RESTRICTED AREA
AREA UNDER CONSTRUCTION
PAPER CADDY
ICRA, ILSM, FIRE WATCH,
MISC. FORMS
FRAMED COPY OF C.O.R.
CERTIFICATION
C L A
S S
I
II
1. REMOVE OR ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO
PREVENT CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH
PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS IF INDICATED.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
6. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL
DEPARTMENT AND THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL SERVICES
DEPARTMENT.
1. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
2. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.
4. WET MOP AREA WITH DISINFECTANT.
5. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
PRIOR TO ANY CONSTRUCTION
POST CONSTRUCTION
7. PLACE A WALK-OFF MAT AND A STICKY MAT AT ENTRANCE AND EXIT WORK AREAS.
3. REMOVE AND DISCARD WALK-OFF MAT AND STICKY MAT AT ENTRY AND WORK AREAS.
8. PROVIDE INSPECTED/DATED FIRE EXTINGUISHER(S) IN THE WORK AREAS.
CLASS III WORK ITEMS NOTES:
ALL PERSONNEL ENTERING THE CONSTRUCTION SITE AREA MUST WEAR A HARD HAT AND SAFETY GLASSES ALONG
WITH ANY OTHER PPE REQUIRED IN THAT AREA.
ALL APPLICABLE FORMS SHALL BE COMPLETED AND APPROVED PRIOR TO STARTING WORK.
PERMITS TO INCLUDE:
ICRA, ILSM, ABOVE CEILING, FIRE SPRINKLER SYSTEM, UTILITY SHUT-DOWN, FIRE / SMOKE WALL, FIRE ALARM
SYSTEM.
THE CONSTRUCTION AREA MUST MAINTAIN A NEGATIVE PRESSURE VENTILATION. NEGATIVE AIR UNIT SHALL BE MAINTAINED WITH FILTER REPLACEMENT(S) PER SPECIFICATIONS (WEEKLY REPLACEMENT OF PRE-FILTER OR AS NECESSARY). HEPA FILTER SHALL BE REPLACED MONTHLY. CLEAN ALL EXTERIOR SURFACES OF CARTS AND TOOLS AT THE END OF EACH SHIFT. MONITOR NEGATIVE PRESSURE AND POST LOG AT THE END OF EACH SHIFT.
CONSTRUCTION CLASS WILL BE DETERMINED BY THE CONSTRUCTION SAFETY COMMITTEE.
DURING CONSTRUCTION BE CERTAIN THAT:
• BARRIERS ARE INTACT AND MAINTAINED.
• PARTICLE COUNT METER IS AVAILABLE.
• NEGATIVE INDICATOR IS AVAILABLE.
• INSPECTED / DATED FIRE EXTINGUISHER(S) ARE AVAILABLE AND MOUNTED PROPERLY.
• ICRA REQUIREMENTS ARE INTACT AND VERIFY THAT THEY ARE BEING MAINTAINED.
• WALK-OFF MATS AND STICKY MATS ARE MAINTAINED PROPERLY.
CONTRACTOR SHALL MAINTAIN BARRIERS, CONFIRM NEGATIVE CONSTRUCTION SPACES, AND DOCUMENT ICRA
REQUIREMENTS DAILY.
SEE SPECIFICATIONS FOR MORE INFECTION CONTROL INFORMATION.
A
B
C
D
E
F
G E N E R A L N O T E S
G
H
LOW RISK
OFFICE AREAS
PATIENT RISK GROUPS
MEDIUM RISK HIGH RISK HIGHEST RISK
CARDIOLOGY CCU ANY AREA CARING FOR
ECHOCARDIOGRAPHY
ENDOSCOPY
NUCLEAR MEDICINE
PHYSICAL THERAPY
RADIOLOGY/MRI
RESPIRATORY THERAPY
EMERGENCY ROOM
LABOR & DELIVERY
LABORATORY (SPECIMEN)
NEWBORN NURSERY
OUTPATIENT SURGERY
PEDIATRICS
IMMUNOCOMPROMISED PATIENTS
BURN UNIT
CARDIAC CATH LAB
CENTRAL STERILE SUPPLY
INTENSIVE CARE UNITS
MEDICAL UNIT
PHARMACY
POST ANESTHESIA CARE UNIT
SURGICAL UNITS
NEGATIVE PRESSURE ISOLATION ROOMS
ONCOLOGY
OPERATING ROOMS INCLUDING
C-SECTION ROOMS
LOW RISK GROUP
CONSTRUCTION PROJECT TYPE
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
RISK RELATED GROUP TYPE A TYPE B TYPE C TYPE D
I II II III/IV
II
II III/IV
III/IV
III
III/IV
IV
IV
IV
I
I
II
CONSTRUCTION PROJECT BY PATIENT RISK
IC MATRIX - CLASS OF PRECAUTIONS:
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISKNOTE:
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
32…