07.05_AC141 - SECOND FLOOR REFLECTED CEILING PLAN.pdf
PDF 862 KB Posted
- Solicitation number
- 36C24923R0030
About this file
This document contains plans for a second floor reflected ceiling at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The project involves renovating D Wing of Building 200 to create an isolation ward. Key details include specifications for different types of ceiling tiles, lighting fixtures, HVAC diffusers, and other ceiling-mounted equipment throughout the ward and support areas. Medical gas and power requirements are also identified on the plans. The related federal contract opportunity is for project number 621-20-107 to complete the renovation work according to the plans and specifications. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 9 for an isolation ward in D Wing of Building 200 at the James H. Quillen VAMC in Mountain Home, Tennessee.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DD D D
D D
D D
D
D
D
D
" R
EL
AY
RA
C
K
FR
O
N T
" R
EL
AY
RA
C
K
FR
O
N T
S S
S S S
P N M L K I H G F E C
35.1
D B.5 B A.5 A
30.1
32.8
O
ISO ROOM 1
D201B
ISO ROOM 2
D202B
ISO ROOM 3
D203B
ISO ROOM 4
D204B
ISO ROOM 5
D205B
ISO ROOM 6
D206B
ISO ROOM 7
D207B
ISO ROOM 8
D208B
ISO ROOM 9
D209B
ISO ROOM 10
D210B
ISO ROOM 11
D211B
ISO ROOM 12
D212B
TOILET
D201C
ANTEROOM
D201A
TOILET
D202C
ANTEROOM
D202A
TOILET
D204C
TOILET
D203C
ANTEROOM
D203A
ANTEROOM
D204A
ANTEROOM
D205A
TOILET
D205C
TOILET
D-206C
ANTEROOM
D206A ANTEROOM
D207A
TOILET
D208C
TOILET
D207C
ANTEROOM
D208A
ANTEROOM
D209A
TOILET
D210C
TOILET
D209C
ANTEROOM
D210A
ANTEROOM
D211A
TOILET
D212C
TOILET
D211C
ANTEROOM
D212A
CHART ALCOVE
D201D
CHART ALCOVE
D203D
CHART ALCOVE
D205D
CHART ALCOVE
D207D
CHART ALCOVE
D209D
CHART ALCOVE
D211D
EQUIPMENT
D214
ELECTRICAL
D233
NOURISHMENT
D215
HUDDLE
D216
CLEAN
D219
LINEN
D220 SOILED
D221
NURSE STATION
D223
OIT
D222
MED
D224
NURSE MANAGER
D227
LAB ALCOVE
D226
BIOMED
D235
MECHANICAL
H.A.C.
STAIRS
S1
STAFF TOILET
D230
LOUNGE
D228
CORRIDOR
D2C3
RESTROOM
D218
ALCOVE
D217
ALCOVE
D213
WOMEN'S LOCKER
D231
MEN'S LOCKER
D232
STORAGE
D229
X-RAY ALCOVE
D225
1 1
1 1
2 2
CONSULT
D234
8' - 0"
8' - 0"
8' - 0"
CORRIDOR
D2C2
4 4
4 4
4 4
4 4
4 4
8' - 0"
10' - 0"
4 4
CORRIDOR
D2C4B
CORRIDOR
D2C5
CORRIDOR
C6
ELEVATOR LOBBY
D2EL2
10' - 0"
CORRIDOR
D2C1
9' - 6" 19' - 0" 1' - 8" 22' - 4" 22' - 6" 23' - 0" 22' - 6" 26' - 0" 26' - 0" 26' - 0" 10' - 0" 4' - 6" 10' - 3" 10' - 0" 10' - 0" 10' - 0"
1'
9'
9'
0"
6'
9'
9" 9'
10' - 0"
ALIGN
15' - 7 3/4"
1' - 11"
/2
1' - 0"
ALIGN
ALIGN
ALIGNALIGN
ALIGN 1
/4
ALIGN 1
/4
5 5 5
5 5 5 5
CORRIDOR
D2C3B
10' - 0"
G E N E R A L C E I L I N G N O T E S
A. REFER TO AI601 FINISH LEGEND FOR FINISH INFORMATION.
B. PROVIDE GYPSUM BOARD AND COLD FORMED STEEL FRAMING BULKHEADS WHERE CEILINGS OF DIFFERENT HEIGHTS ABUT. DO NOT
BUILD BULKHEADS OF ACOUSTICAL CEILING MATERIAL UNLESS SPECIFICALLY DETAILED.
C. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES. SCRIBE
CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
D. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC. SCRIBE
CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
E. ALL CEILINGS ARE AT 9'-0" A.F.F. UNLESS OTHERWISE NOTED
F. VERIFY CEILING HEIGHTS WITH STRUCTURE AND DUCTWORK.
G. AVOID CUTTING TILES SMALLER THAN 6".
H. CENTER SPRINKLER HEADS WITHIN CEILING TILES. COORDINATE WITH OTHER CEILING MOUNTED ACCESSORIES.
I. ALL VERTICAL FACES OF SOFFITS OR BULKHEADS SHALL BE FINISHED TO MATCH ADJACENT SURFACES.
J. ALL PATIENT ROOMS RECEIVE CEILING-MOUNTED PATIENT LIFT - SEE STRUCTURAL DRAWINGS.
BUILDING 200
C E I L I N G L E G E N D
2'-0" x 2'-0" ACOUSTICAL TILE CEILING
GYPSUM BOARD CEILING
2'-0" x 2'-0" SUPPLY AIR DIFFUSER
2'-0" x 1'-0" EXHAUST AIR GRILLE
2'-0" x 1'-0" RETURN AIR GRILLE
4'-0" LINEAR DIFFUSER
6" CAN LIGHT
SPEAKER
DATA OUTLET
NURSE CALL DOME LIGHT
2'-0" x 2'-0" LED LIGHT FIXTURE
4'-0" LINEAR LED LIGHT FIXTURE
S
D2'-0" x 2'-0" EXHAUST AIR GRILLE
2'-0" x 2'-0" RETURN AIR GRILLE
CABLE TRAY
EXIT SIGN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/1
/2
:0
:4
P
M
AC141
SECOND FLOOR REFLECTED
CEILING PLAN
11/04/2022 ET TD
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
D R A W I N G N O T E S
1 GYPSUM WALLBOARD BULKHEAD AT 8'-0" AFF.
2 OMIT CEILING IN THIS LOCATION.
3 GYPSUM BOARD CEILING AND ASSOCIATED SUPPORT SYSTEM.
4 2'-0" X 2'-0" WASHABLE CLEAN ROOM GRADE ACOUSTICAL CEILING TILE AND GASKETED CEILING WITH ASSOCIATED SUSPENDED SUPPORT SYSTEM. SUPPORT TO STRUCTURE ABOVE PER MANUFACTURER'S RECOMMENDATION AND VA
SPECIFICATION REQUIREMENTS.
5 CEILING MOUNTED PATIENT LIFT.
6 1000 POUND RATED CEILING MOUNTED PATIENT LIFT.
N
1/8" = 1'-0"
SECOND FLOOR REFLECTED CEILING PLAN
N
NTS
KEYPLAN
No. Revisions: Date:
BID DOCUMENTS 11/04/2022
2 ADDENDUM #2 07/13/2023
GYPSUM BULK HEAD ABOVE CASEWORK - REFER TO CASEWORK DETAILS.7
| Sheets |
| AC141 - SECOND FLOOR REFLECTED CEILING PLAN |
File details come from the government source that posted it. Updated .