087100 Door Hardware.pdf
PDF 177 KB Posted
- Solicitation number
- 36C24923R0030
About this file
This document provides hardware specifications for Project 621-20-107 to renovate Building 200, Wing D2 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee for use as an isolation ward. Key hardware requirements include aluminum breakaway sliding door assemblies, fire rated storeroom locks, privacy locks, office locks, classroom locks, card access mortise locks, electronic strikes, door closers, overhead and floor door stops, wall bumpers, coordinators, gasketing, and continuous hinges. The specifications establish hardware standards, finishes, base metals, installation requirements, hardware sets for various door functions, and a list of applicable publications. The related federal contract opportunity is solicitation number 36C24923R0030 for the renovation project managed by the Department of Veterans Affairs Veterans Health Administration VISN 9.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum #2 James H. Quillen VA Medical Center
Renovation Wing D2 for Isolation Ward
VA Project Number: 621-20-107
05-01-22
087100 - 1
DOOR HARDWARE
SECTION 08 71 00
PART 1 - GENERAL
1.1 DESCRIPTION
A. Door hardware and related items necessary for complete installation and operation of doors.
1.2 RELATED WORK
A. Caulking: Section 07 92 00 JOINT SEALANTS.
B. Application of Hardware: Section 08 11 13, HOLLOW METAL DOORS AND
FRAMES
C. Section 08 14 00, WOOD DOORS
D. Painting: Section 09 91 00, PAINTING.
E. Card Readers: Section 28 13 00, PHYSICAL ACCESS CONTROL SYSTEMS.
F. Electrical: Division 26, ELECTRICAL.
1.3 GENERAL
A. All hardware shall comply with ABAAS, (Architectural Barriers Act
Accessibility Standard) unless specified otherwise.
B. Provide rated door hardware assemblies where required by most current version of the International Building Code (IBC).
C. Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that it conforms to NFPA requirements.
D. Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.
E. The following items shall be of the same manufacturer, except as otherwise specified:
1. Mortise locksets.
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
087100 - 2
4. Exit devices.
5. Floor closers.
1.4 WARRANTY
A. Automatic door operators shall be subject to the terms of FAR Clause
52.246-21, except that the Warranty period shall be two years in lieu of one year for all items except as noted below:
1. Locks, latchsets, and panic hardware: 5 years.
2. Door closers and continuous hinges: 10 years.
1.5 MAINTENANCE MANUALS
A. In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.
1.6 SUBMITTALS
A. Submittals shall be in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Submit 6 copies of the schedule per Section
01 33 23. Submit 2 final copies of the final approved schedules to VAMC
Locksmith as record copies (VISN Locksmith if the VAMC does not have a locksmith).
B. Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:
Hardware
Item
Quantity Size Reference
Publication
Type No.
Finish Mfr.
Name and
Catalog
No.
Key
Control
Symbols
UL Mark
(if fire rated and listed)
ANSI/BHMA
Finish
Designation
C. Samples and Manufacturers' Literature:
1. Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers
Association shall be submitted for approval. Tag and mark all items with manufacturer's name, catalog number and project number.
087100 - 3
2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.
D. Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates shall be accompanied by copies of reports as referenced. The testing shall have been conducted either in the manufacturer's plant and certified by an independent testing laboratory or conducted in an independent laboratory, within four years of submittal of reports for approval.
1.7 DELIVERY AND MARKING
A. Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to
COR for reference purposes. Tag shall identify items by Project
Specification number and manufacturer's catalog number. These items shall remain on file in COR's office until all other similar items have been installed in project, at which time the COR will deliver items on file to Contractor for installation in predetermined locations on the project.
1.8 PREINSTALLATION MEETING
A. Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contractor and Installer, Architect, Project Engineer and VA Locksmith, Hardware Consultant, and
Hardware Manufacturer’s Representative. Review the following:
1. Inspection of door hardware.
2. Job and surface readiness.
3. Coordination with other work.
4. Protection of hardware surfaces.
5. Substrate surface protection.
6. Installation.
7. Adjusting.
8. Repair.
9. Field quality control.
10. Cleaning.
087100 - 4
1.9 INSTRUCTIONS
A. Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols.
Symbols for hardware sets consist of letters (e.g., "HW") followed by a number. Each number designates a set of hardware items applicable to a door type.
1.10 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.
B. ASTM International(ASTM):
F883-13.................Padlocks
E2180-18................Standard Test Method for Determining the
Activity of Incorporated Antimicrobial Agent(s)
In Polymeric or Hydrophobic Materials
C. American National Standards Institute/Builders Hardware Manufacturers
Association (ANSI/BHMA):
A156.1-06...............Butts and Hinges
A156.3-08...............Exit Devices, Coordinators, and Auto Flush
Bolts
A156.4-08...............Door Controls (Closers)
A156.5-14...............Cylinders and Input Devices for Locks.
A156.6-05...............Architectural Door Trim
A156.8-05...............Door Controls-Overhead Stops and Holders
A156.13-05..............Mortise Locks and Latches Series 1000
A156.16-08..............Auxiliary Hardware
A156.18-06..............Materials and Finishes
A156.22-05..............Door Gasketing and Edge Seal Systems
A156.25-07 .............Electrified Locking Devices
A156.26-06..............Continuous Hinges
A156.28-07 .............Master Keying Systems
A156.29-07 .............Exit Locks and Alarms
087100 - 5
A156.36-10..............Auxiliary Locks
A250.8-03...............Standard Steel Doors and Frames
D. National Fire Protection Association (NFPA):
80-10...................Fire Doors and Other Opening Protectives
101-09..................Life Safety Code
E. Underwriters Laboratories, Inc. (UL):
Building Materials Directory (2008)
PART 2 - PRODUCTS
2.1 BUTT HINGES
A. ANSI A156.1. The following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:
1. Interior Doors: Type A8112/A5112 for doors 900 mm (3 feet) wide or less and Type A8111/A5111 for doors over 900 mm (3 feet) wide.
Hinges for doors exposed to high humidity areas (shower rooms, toilet rooms, kitchens, janitor rooms, etc. shall be of stainless-steel material.
B. Provide quantity and size of hinges per door leaf as follows:
1. Doors up to 1210 mm (4 feet) high: 2 hinges.
2. Doors 1210 mm (4 feet) to 2260 mm (7 feet 5 inches) high: 3 hinges minimum.
3. Doors greater than 2260 mm (7 feet 5 inches) high: 4 hinges.
4. Doors up to 900 mm (3 feet) wide, standard weight: 114 mm x 114 mm
(4-1/2 inches x 4-1/2 inches) hinges.
5. Doors over 900 mm (3 feet) to 1065 mm (3 feet 6 inches) wide, standard weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
6. Provide heavy-weight hinges where specified.
7. At doors weighing 330 kg (150 pounds) or more, furnish 127 mm (5 inch) high hinges.
C. See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above, and continuous hinges specified below.
2.2 CONTINUOUS HINGES
A. ANSI/BHMA A156.26, Grade 1-600.
1. Listed under Category N in BHMA's "Certified Product Directory."
B. General: Minimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width of 4 inches (102 mm); fabricated to full height
087100 - 6 of door and frame and to template screw locations; with components finished after milling and drilling are complete
C. Continuous, Barrel-Type Hinges: Hinge with knuckles formed around a
Teflon-coated 6.35mm (0.25-inch) minimum diameter pin that extends entire length of hinge.
1. Base Metal for Interior Hinges: Steel.
2. Base metal for double-acting. Pin and barrel hinges: Extruded aluminum.
3. Base Metal for Hinges for Fire-Rated Assemblies: Steel.
4. Provide with non-removable pin (hospital tip option) at lockable outswing doors.
5. Where required to clear adjacent casing, trim, and wall conditions and allow full door swing, provide wide throw hinges of minimum width required.
6. Provide with manufacturer’s cut-outs for separate mortised power transfers and/or mortised automatic door bottoms where they occur.
7. Where thru-wire power transfers are integral to the hinge, provide hinge with easily removable portion to allow easy access to wiring connections.
8. Where models are specified that provide an integral wrap-around edge guard for the hinge edge of the door, provide manufacturer’s adjustable threaded stud and machine screw mechanism to allow the door to be adjusted within the wrap-around edge guard.
2.3 DOOR CLOSING DEVICES
A. Closing devices shall be products of one manufacturer for each type specified.
2.4 OVERHEAD CLOSERS
A. Conform to ANSI A156.4, Grade 1.
B. Closers shall conform to the following:
1. The closer shall have minimum 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.
2. Where specified, closer shall have hold-open feature.
087100 - 7
3. Size Requirements: Provide multi-size closers, sizes 1 through 6, except where multi-size closer is not available for the required application.
4. Material of closer body shall be forged or cast.
5. Arm and brackets for closers shall be steel, malleable iron or high strength ductile cast iron.
6. Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless-steel material.
7. Closers shall have full size metal cover; plastic covers will not be accepted.
8. Closers shall have adjustable hydraulic back-check, separate valves for closing and latching speed, adjustable back-check positioning valve, and adjustable delayed action valve.
9. Provide closers with any accessories required for the mounting application, including (but not limited to) drop plates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bullnose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provide special arms, drop plates, and templating as needed to allow mounting at doors with overhead stops and/or holders.
10. Closer arms or backcheck valve shall not be used to stop the door from overswing, except in applications where a separate wall, floor, or overhead stop cannot be used.
11. Provide parallel arm closers with heavy duty rigid arm.
12. Where closers are to be installed on the push side of the door, provide parallel arm type except where conditions require use of top jamb arm.
13. Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.
14. All closers shall have a 1 ½” (38mm) minimum piston diameter.
2.5 DOOR STOPS
A. Conform to ANSI A156.16.
B. Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of
087100 - 8 building construction. For concrete, masonry or quarry tile construction, use expansion shields for mounting door stops.
C. Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.
D. Provide floor stops (Type L02141 or L02161) in office areas; Type
L02121 x 3 screws into floor elsewhere. Wall bumpers, where used, must be installed to impact the trim or the door within the leading half of its width. Floor stops, where used, must be installed within 4-inches of the wall face and impact the door within the leading half of its width.
E. Where drywall partitions occur, use floor stops, Type L02141 or L02161 in office areas, Type L02121 elsewhere.
F. Provide stop Type L02011, as applicable for exterior doors. At outswing doors where stop can be installed in concrete, provide stop mated to concrete anchor set in 76mm (3-inch) core-drilled hole and filled with quick-setting cement.
G. Omit stops where floor mounted door holders are required and where automatic operated doors occur.
H. Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.
I. Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.
J. Provide overhead surface applied stop Type C02541, ANSI A156.8 on patient toilet doors in bedrooms where toilet door could come in contact with the bedroom door.
K. Provide door stops on doors where combination closer magnetic holders are specified, except where wall stops cannot be used or where floor stops cannot be installed within 4-inches of the wall.
L. Where the specified wall or floor stop cannot be used, provide concealed overhead stops (surface-mounted where concealed cannot be used).
2.6 OVERHEAD DOOR STOPS AND HOLDERS
A. Conform to ANSI Standard A156.8. Overhead holders shall be of sizes recommended by holder manufacturer for each width of door. Set overhead
087100 - 9 holders for 110 degree opening, unless limited by building construction or equipment. Provide Grade 1 overhead concealed slide type: stop-only at rated doors and security doors, hold-open type with exposed hold-open on/off control at all other doors requiring overhead door stops.
2.7 FLOOR DOOR HOLDERS
A. Conform to ANSI Standard A156.16. Provide extension strikes for Types
L01301 and L01311 holders where necessary.
2.8 LOCKS AND LATCHES
A. Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylinders shall have seven pins. Cylinders for all locksets shall be removable core type.
Cylinder shall be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type of lock included in the Great Grand Master Key System. Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with
19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label. Provide temporary keying device or construction core to allow opening and closing during construction and prior to the installation of final cores.
B. In addition to above requirements, locks and latches shall comply with following requirements:
1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets shall have lever handles fabricated from cast stainless steel. Provide sectional (lever x rose) lever design matching existing on-site. No substitute lever material shall be accepted.
All locks and latchsets shall be furnished with 122.55 mm (4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function F02 shall be furnished with emergency tools/keys for emergency entrance. All lock cases installed on lead lined doors shall be lead lined before applying final hardware finish. Furnish armored fronts for all mortise locks.
Where mortise locks are installed in high-humidity locations or
087100 - 10 where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.
2.
2.9 FLUSH BOLTS (LEVER EXTENSION)
A. Conform to ANSI A156.16. Flush bolts shall be Type L24081 unless otherwise specified. Furnish proper dustproof strikes conforming to
ANSI A156.16, for flush bolts required on lower part of doors.
B. Lever extension manual flush bolts shall only be used at non-fire-rated pairs for rooms only accessed by maintenance personnel.
C. Face plates for cylindrical strikes shall be rectangular and not less than 25 mm by 63 mm (1 inch by 2-1/2 inches).
D. Friction-fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.
E. Provide extension rods for top bolt where door height exceeds 2184 mm
(7 feet 2 inches).
2.10 FLUSH BOLTS (AUTOMATIC)
A. Conform to ANSI A156.3. Dimension of flush bolts shall conform to ANSI
A115. Bolts shall conform to Underwriters Laboratories, Inc., requirements for fire door hardware. Flush bolts shall automatically latch and unlatch. Furnish dustproof strikes conforming to ANSI A156.16 for bottom flushbolt. Face plates for dustproof strike shall be rectangular and not less than 38 mm by 90 mm (1-1/2 by 3-1/2 inches).
B. At interior doors, provide auto flush bolts less bottom bolt, unless otherwise specified, except at wood pairs with fire-rating greater than
20 minutes; provide fire pins as required by auto flush bolt and door fire labels.
2.11 COORDINATORS
A. Conform to ANSI A156.16. Coordinators, when specified for fire doors, shall comply with Underwriters Laboratories, Inc., requirements for fire door hardware. Coordinator may be omitted on interior pairs of non-labeled open where open back strike is used. Open back strike shall not be used on labeled doors. Paint coordinators to match door frames, unless coordinators are plated. Provide bar type coordinators, except where gravity coordinators are required at acoustic pairs. For bar type coordinators, provide filler bars for full width and as required, 087100 - 11 brackets for push-side surface mounted closers, overhead stops, and vertical rod panic strikes.
2.12
2.13 FINISHES
A. Exposed surfaces of hardware shall have ANSI A156.18, finishes as specified below. Finishes on all hinges, pivots, closers, thresholds, etc., shall be as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.
B. 626 or 630: All surfaces on interior of buildings, except where other finishes are specified.
C. Miscellaneous Finishes:
1. Hinges --interior doors: 652 or 630.
2. Door Closers: Factory applied powder coat paint finish. Dull or
Satin Aluminum color.
3. Other primed steel hardware: 600.
D. Hardware Finishes for Existing Buildings: U.S. Standard finishes shall match finishes of hardware in (similar) existing spaces except where otherwise specified.
2.14 BASE METALS
A. Apply specified U.S. Standard finishes on different base metals as following:
Finish Base Metal
652 Steel
626 Brass or bronze
630 Stainless steel
PART 3 - EXECUTION
3.1 HARDWARE HEIGHTS
A. For existing buildings locate hardware on doors at heights to match existing hardware. The Contractor shall visit the site, verify location of existing hardware and submit locations to VA COR for approval.
B. Hardware Heights from Finished Floor:
1. Exit devices centerline of strike (where applicable) 1024 mm (40-
5/16 inches).
087100 - 12
2. Locksets and latch sets centerline of strike 1024 mm (40-5/16 inches).
3. Deadlocks centerline of strike 1219 mm (48 inches).
4. Hospital arm pull 1168 mm (46 inches) to centerline of bottom supporting bracket.
5. Centerline of door pulls to be 1016 mm (40 inches).
6. Push plates and push-pull shall be 1270 mm (50 inches) to top of plate.
7. Push-pull latch to be 1024 mm (40-5/16 inches) to centerline of strike.
8. Locate other hardware at standard commercial heights. Locate push and pull plates to prevent conflict with other hardware.
3.2 INSTALLATION
A. Closer devices, including those with hold-open features, shall be equipped and mounted to provide maximum door opening permitted by building construction or equipment. Closers shall be mounted on side of door inside rooms, inside stairs, and away from corridors
B. Hinge Size Requirements:
Door Thickness Door Width Hinge Height
45 mm (1-3/4 inch) 900 mm (3 feet) and less 113 mm (4-1/2 inches)
C. Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.
D. Where new hinges are specified for new doors in existing frames or existing doors in new frames, sizes of new hinges shall match sizes of existing hinges; or, contractor may reuse existing hinges provided hinges are restored to satisfactory operating condition as approved by
COR. Existing hinges shall not be reused on door openings having new doors and new frames. Coordinate preparation for hinge cut-outs and screw-hole locations on doors and frames.
E. Hinges Required Per Door:
Door Description Number butts
Doors 1500 mm (5 ft) or less in height 2 butts
Doors over 1500 mm (5 ft) high and not over 2280 mm 3 butts
087100 - 13
Door Description Number butts
(7 ft 6 in) high
Doors over 2280 mm (7 feet 6 inches) high 4 butts
Dutch type doors 4 butts
Doors with spring hinges 1370 mm (4 feet 6 inches) high or less
2 butts
Doors with spring hinges over 1370 mm (4 feet 6 inches) 3 butts
F. Fastenings: Suitable size and type and shall harmonize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted.
All fastenings exposed to weather shall be of nonferrous metal.
G. After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements.
(All keys, Master Key level and above shall be sent Registered Mail to the Medical Center Director along with the bitting list. Also, a copy of the invoice shall be sent to the COR for his records.) Installation of locks which do not meet specified keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.
3.3 FINAL INSPECTION
A. Installer to provide letter to VA Resident/Project Engineer that upon completion, installer has visited the Project and has accomplished the following:
1. Re-adjust hardware.
2. Evaluate maintenance procedures and recommend changes or additions and instruct VA personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems.
3.4 DEMONSTRATION
A. Demonstrate efficacy of mechanical hardware and electrical, and electronic hardware systems, including adjustment and maintenance procedures, to satisfaction of Resident/Project Engineer and VA
Locksmith.
087100 - 14
3.5 HARDWARE SETS (ALL HARDWARE SETS HAVE BEEN UPDATED)
A. Following sets of hardware correspond to hardware symbols shown on drawings. Only those hardware sets that are shown on drawings will be required. Disregard hardware sets listed in specifications but not shown on drawings.
B. Hardware Consultant working on a project will be responsible for providing additional information regarding these hardware sets. The numbers shown in the following sets come from BHMA standards.
C. Scheduled hardware indicates quantity of components required at individual single or double doors. Furnish hardware quantities required for every door listed at the set.
1. MK - McKinney
2. MR - Markar
3. BA – Best Access
4. RF- Rixon
5. NO – Norton
6. RO - Rockwood
7. PE – Pemko
8. ID- Identiv
9. SU – Securitron
10. PR- Precision (Best Access)
11. HS- HES
12. HO- Horton Automatics
13. VP- Von Duprin
14. BE- BEA
Hardware Sets
Set: 1.0
Doors: 10B, 11B, 12B, 1B, 2B, 3B, 4B, 5B, 6B, 7B, 8B, 9B
Description: Aluminum Breakaway Sliding Door Assemblies
Mortise, Positive Latch and
Handle Assembly Door Company 689
Notes: Balance of hardware by door manufacturer.
087100 - 15
Set: 1.1
Doors: 10A, 11A, 12A, 1A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 9A
Description: Aluminum Breakaway Sliding Door Assemblies
Mortise, Positive Latch and
Handle Assembly Door Company 689
Notes: Balance of hardware by door manufacturer.
Set: 2.0
Doors: 33
Description: Fire Rated Storeroom Function Exit - Electrical Room NEC
3 Hinge, Full Mortise TA2714 NRP 5" x 4-1/2" US26D MK
1 Rim Exit Device, Storeroom S2100 US32D PR
1 Mortise Cylinder E Series US15 BA
1 Surface Closer, Spring Stop CLP7500 SN-134 689 NO
1 Kick Plate K1050 12" High US32D RO
1 Gasketing S88BL X Head & Jambs PE
Set: 2.1EM
Doors: 18
Description: Privacy Function - Double Acting + Emergency Hardware
1 Cont Hinge, Double Swing DSH1000-84C MR
Privacy Lock + Occupancy
Indicator Mortise Lock
45HOLT3J626VIT US26D BA
1 Wall Stop 406 US32D RO
1 Emergency Stop ERSMP84C-NOTCHxHT PE
Notes: Cased opening profile at hinge jamb & head. Single rabbet profile at strike jamb.
Set: 2.2
Doors: 30
Description: Privacy Function + Closer
087100 - 16
Privacy Lock + Occupancy
Indicator Mortise Lock
45HOLT3J626VIT US26D BA
1 Surface Closer 7500 SN-134 689 NO
1 Kick Plate K1050 12" High US32D RO
1 Wall Stop 406 US32D RO
1 Gasketing S88BL X Head & Jambs PE
1 Coat Hook 796 US26D RO
Set: 2.3
Doors: 10C, 11C, 12C, 1C, 2C, 3C, 4C, 5C, 6C, 7C, 8C, 9C
Description: Privacy Function - Patient Room Toilet
Privacy Lock + Occupancy
Indicator Mortise Lock
45HOLT3J626VIT US26D BA
1 Surf Overhead Stop 9-436 630 RF
1 Kick Plate K1050 12" High US32D RO
3 Silencer 608-RKW RO
1 Coat Hook 796 US26D RO
Set: 3.0
Doors: 27
Description: Office Function
3 Hinge, Full Mortise TA2714 NRP 4-1/2" x 4-1/2" US26D MK
1 Office Mortise Lock 45H7A3H626 US26D BA
1 SFIC Permanent Core Best Cormax US15 BA
Set: 3.1
Doors: *** HARDWARE SET NOT USED
Description: Office Function
1 SFIC Permanent Core Best Cormax US15 BA
087100 - 17
Set: 3.2
Doors: 34
Description: Office Function + Closer
1 SFIC Permanent Core Best Cormax US15 BA
1 Surface Closer, Spring Stop CLP7500 SN-134 689 NO
Set: 4.0
Doors: 138
Description: Classroom Function
1 Classroom Mortise Lock 45H7R3H626 US26D BA
1 SFIC Permanent Core Best Cormax US15 BA
Set: 4.1
Doors: *** HARDWARE SET NOT USED
Description: Classroom Function
1 Classroom Mortise Lock 45H7R3H626 US26D BA
1 SFIC Permanent Core Best Cormax US15 BA
Set: SH.0
Doors: 14A *** HARDWARE SET NOT USED
Description: Storeroom Function
1 Storeroom Mortise Lock 45H7A3H626 US26D BA
087100 - 18
1 SFIC Permanent Core Best Cormax US15 BA
Set: SH.2
Doors: 32
Description: Card Access + Closer
1 Storeroom Mortise Lock 45H7D3H626 US26D BA
1 Fail Secure Electric Strike 4500C US26D HS
1 SFIC Permanent Core Best Cormax US15 BA
1 Surface Closer, HDPA PR7500 SN-134 689 NO
1 Kick Plate K1050 12" High US32D RO
1 Wall Stop 406 US32D RO
3 Silencer 608-RKW RO
1 Exit Control Motion Sensor EXMS SU
1 ElectroLynx Harness QC-C300P MK
1 Wall Card Reader 8332ABTR000 Type A Blk ID
1 Interior Flush Mount Box MB8 ID
1 Position Switch DPS-M-GR SU
1 Power Supply AQD Series as Required SU
Notes: Door position is monitored by magnetic switch for authorized egress.
Security management software and access control panel by others.
Prep door frame for electronic strike.
OPERATION: Card Reader outside temporarily unlocks electronic strike: auto-relock. Electronic strike function is fail-secure with inside RX switch. Outside trim has key override. Inside trim always allows egress.
Set: SH.3
Doors: 31
1 Fail Secure Electronic Strike 4500C US26D HS
1 SFIC Permanent Core Best Cormax US15 BA
087100 - 19
1 Surface Closer, Spring Stop CLP7500 SN-134 689 NO
3 Silencer 608-RKW RO
1 Exit Control Motion Sensor EXMS SU
1 Interior Flush Mount Box MB8 ID
1 Wall Card Reader 8332ABTR000 Blk ID
1 Position Switch DPS-M-GR SU
Prep door frame for electronic strike.
OPERATION: Card Reader outside temporarily unlocks electronic strike: auto-relock. Electronic strike function is fail-secure with inside RX switch. Outside trim has key override. Inside trim always allows
Set: SH.4
Doors: 139
1 Fail Secure Electronic Strike 4500C US26D HS
1 SFIC Permanent Core Best Cormax US15 BA
1 Surface Closer 7500 SN-134 689 NO
1 Wall Stop 406 US32D RO
3 Silencer 608-RKW RO
1 Exit Control Motion Sensor EXMS SU
1 Interior Flush Mount Box MB8 Blk ID
1 Wall Card Reader 8332ABTR000 Blk ID
1 Position Switch DPS-M-GR SU
Prep door frame for electronic strike.
OPERATION: Card Reader outside temporarily unlocks electronic strike: auto-relock. Electronic strike function is fail-secure with inside RX switch. Outside trim has key override. Inside trim always allows
087100 - 20
Set: SH.5
Doors: 14A, 14B, 19A, 19B, 20A, 20B, 21A, 21B, 22, 24
Description: Rated Card Access + Delayed Action Closer
1 Fail Secure Electronic Strike 4500C US26D HS
1 SFIC Permanent Core Best CORMAX US15 BA
1 Surface Closer, Delayed Action 7500 DA SN-134 689 NO
1 Kick Plate K1050 12" High US32D RO
1 Wall Stop 406 US32D RO
1 Gasketing S88BL X Head & Jambs PE
1 Wall Card Reader 8332ABTR000 Blk ID
1 Interior Flush Mount Box MB8 Blk ID
1 Position Switch DPS-M-GR SU
1 Power Supply AQD Series as Required SU
1 Exit Control Motion Sensor EXMS Type A BSP SU
Prep door frame for electronic strike.
** Mount door closer on room side.
OPERATION: Card Reader outside temporarily unlocks electronic strike: auto-relock. Electronic strike function is fail-secure with inside RX switch. Outside trim has key override. Inside trim always allows
Set: SH.6
Doors: 28
3 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 5" x 4-1/2" US26D MK
1 Fail Secure Strike 4500C US26D HS
1 SFIC Permanent Core Best CORMAX US15 BA
1 Surface Closer, Spring Stop CLP7500 SN-134 689 NO
087100 - 21
1 Interior Flush Mount Box MB8 Blk ID
1 Wall Card Reader 8332ABTR000 Blk ID
1 Position Switch DPS-M-GR SU
1 Power Supply AQD Series as Required SU
1 Exit Control Motion Sensor EXMS Type A SU
Prep door frame for electronic strike.
OPERATION: Card Reader outside temporarily unlocks strike: auto-relock. Electronic strike function is fail-secure with inside RX switch. Outside trim has key override. Inside trim always allows egress.
Set: SH.10
Doors: C2
Description: Rated Double Egress Pair + Low Energy Operators
6 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 5" x 4-1/2" US26A MK
Surf Vert Rod Exit, Exit Only, ELR, RX
Von Duprin QEL US32D VD
2 Automatic Opener S4100LE 689 HO
2 Kick Plate K1050 12" High US32D RO
1 Wall Stop 406 US32D RO
1 Astragal 357SS x Door Height PE
2 ElectroLynx Harness QC-C012P MK
2 ElectroLynx Harness QC-C1500P MK
2 Door Wave Actuator Switch MS41 BE
1 Power Supply AQD Series as Required SU
2 Electric Power Transfer CEPT-10 BSP SU
Notes: Access control panel and security management software by security integrator. Prep door and hinge jamb for electronic device. Provide wire harness in door.
OPERATION: Wave actuator switch either side retract latchbolts and cycle operator. Inside pushbar always allows egress. Electronic devices are fail secure with inside RX switch.
- - -END - - -
File details come from the government source that posted it. Updated .