08.00_AI101 - SECOND FLOOR FINISH PLAN-1.pdf
PDF 3 MB Posted
- Solicitation number
- 36C24923R0030
About this file
This document package includes plans for a federal construction project and the associated solicitation. The plans depict the second floor layout and finishes for renovating Building 200, Wing D2 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee to create an isolation ward. Key areas include 12 isolation rooms, toilet and anteroom spaces, support spaces for nourishment, soiled linen, clean linen, electrical and mechanical areas. The solicitation is for Project #621-20-107 to conduct these renovations. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The response due date is not provided. The plans include notes on finish materials, slopes and details.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P N M L K I H G F E C
35.1
D B.5 B A.5 A
30.1
32.8
O
ISO ROOM 1
D201B
RF-1 ACT-1
P-3RF-1
ISO ROOM 2
D202B
RF-1 ACT-1
P-3RF-1
ISO ROOM 3
D203B
RF-1 ACT-1
P-3RF-1
ISO ROOM 4
D204B
RF-1 ACT-1
P-3RF-1
ISO ROOM 5
D205B
RF-1 ACT-1
P-3RF-1
ISO ROOM 6
D206B
RF-1 ACT-1
P-3RF-1
ISO ROOM 7
D207B
RF-1 ACT-1
P-3RF-1
ISO ROOM 8
D208B
RF-1 ACT-1
P-3RF-1
ISO ROOM 9
D209B
RF-1 ACT-1
P-3RF-1 ISO ROOM 10
D210B
RF-1 ACT-1
P-3RF-1
ISO ROOM 11
D211B
RF-1 ACT-1
P-3RF-1
ISO ROOM 12
D212B
RF-1 ACT-1
P-3RF-1
TOILET
D201C
RF-2 P-6
PT-1RF-2
ANTEROOM
D201A
RF-1 ACT-1
P-3RF-1
TOILET
D202C
RF-1 P-6
PT-1RF-2
ANTEROOM
D202A
RF-1 ACT-1
P-3RF-1
TOILET
D204C
RF-1 P-6
PT-1RF-2
TOILET
D203C
RF-1 P-6
PT-1RF-2
ANTEROOM
D203A
RF-1 ACT-1
P-3RF-1
ANTEROOM
D204A
RF-1 ACT-1
P-3RF-1
ANTEROOM
D205A
RF-1 ACT-1
P-3RF-1
TOILET
D205C
RF-1 P-6
PT-1RF-2
TOILET
D-206C
RF-1 P-6
PT-1RF-2
ANTEROOM
D206A
RF-1 ACT-1
P-3RF-1
ANTEROOM
D207A
RF-1 ACT-1
P-3RF-1
TOILET
D208C
RF-1 P-6
PT-1RF-2
TOILET
D207C
RF-1 P-6
PT-1RF-2
ANTEROOM
D208A
RF-1 ACT-1
P-3RF-1
ANTEROOM
D209A
RF-1 ACT-1
P-3RF-1
TOILET
D210C
RF-1 P-6
PT-1RF-2
TOILET
D209C
RF-1 P-6
PT-1RF-2
ANTEROOM
D210A
RF-1 ACT-1
P-3RF-1
ANTEROOM
D211A
RF-1 ACT-1
P-3RF-1
TOILET
D212C
RF-1 P-6
PT-1RF-2
TOILET
D211C
RF-1 P-6
PT-1RF-2
ANTEROOM
D212A
RF-1 ACT-1
P-3RF-1
CHART ALCOVE
D201D
LVT-1 ACT-2
P-2RB-1
CHART ALCOVE
D203D
LVT-1 ACT-2
P-2RB-1
CHART ALCOVE
D205D
LVT-1 ACT-2
P-2RB-1
CHART ALCOVE
D207D
LVT-1 ACT-2
P-2RB-1
CHART ALCOVE
D209D
LVT-1 ACT-2
P-2RB-1
CHART ALCOVE
D211D
LVT-1 ACT-2
P-2RB-1
EQUIPMENT
D214
RF-1 ACT-2
P-3RB-1
ELECTRICAL
D233
RF-1 EXP
P-3RB-1
NOURISHMENT
D215
LVT-2 ACT-2
P-3RB-2
HUDDLE
D216
LVT-2 ACT-2
P-4RB-2
CLEAN
D219
RF-1 ACT-2
P-3RF-1
LINEN
D220
RF-1 ACT-2
P-3RF-1
SOILED
D221
RF-1 ACT-2
P-3RF-1
NURSE STATION
D223
LVT-1 ACT-2
P-2RB-1
OIT
D222
RF-1 EXP
P-3RF-1
MED
D224
LVT-2 ACT-2
P-3RB-2
NURSE MANAGER
D227
LVT-1 ACT-2
P-2RB-1
LAB ALCOVE
D226
LVT-1 ACT-2
P-2RB-1
BIOMED
D235
CPT-1 EXP
P-3RB-2
MECHANICAL
H.A.C.
STAIRS
S1
STAFF TOILET
D230
RF-1 P-6
PT-1RF-2
LOUNGE
D228
LVT-1 ACT-2
P-4RB-1
CORRIDOR
D2C3
LVT-1 ACT-2
*RB-1
RESTROOM
D218
RF-1 P-6
PT-1RF-2
ALCOVE
D217
LVT-1 P-5
P-2RB-1
ALCOVE
D213
LVT-1 P-5
P-2RB-1
WOMEN'S LOCKER
D231
LVT-2 ACT-2
P-4RB-2
MEN'S LOCKER
D232
LVT-2 ACT-2
P-4RB-2
STORAGE
D229
LVT-1 ACT-2
P-4RB-1
X-RAY ALCOVE
D225
LVT-1 P-5
P-2RB-1
PNEUMATIC TUBE
SHAFT
CORRIDOR
D2C5
LVT-1 ACT-2
*RB-1
CORRIDOR
CORRIDOR
D2C4B
LVT-1 ACT-2
*RB-1
CORRIDOR
D2C2
LVT-1 ACT-2
*RB-1
CORRIDOR
D2C1
LVT-1 ACT-2
*RB-1
CONSULT
D234
CPT-1 ACT-2
P-2RB-2
CORRIDOR
D2C3B
LVT-1 ACT-2
P-3RB-1
VESTIBULE
D236
ELEVATOR LOBBY
D2EL2
LVT-1 ACT-2
-RB-1
CORRIDOR
D2C3A
LVT-1 ACT-2
P-2RB-1
CORRIDOR
D2-C4A
LVT-1 ACT-2
-RB-1
SLOPE =
¼" / 1'-0"
AE502
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
SLOPE =
¼" / 1'-0"
1 1
1 1
9' - 6" 19' - 0" 1' - 8" 22' - 4" 22' - 6" 23' - 0" 22' - 6" 26' - 0" 26' - 0" 26' - 0" 10' - 0" 4' - 6" 10' - 3" 10' - 0" 10' - 0" 10' - 0"
1'
9'
9'
0"
6'
9'
G E N E R A L F I N I S H N O T E S
A. ALL WALLS SHALL BE PAINTED P-1 AND ALL CEILING SHALL BE PAINTED P-3 UNLESS OTHERWISE NOTED. REFER TO FINISH
PLAN/RCP FOR ACCENT WALLS/CEILINGS.
B. PROVIDE METAL BACKING AND / OR METAL BLOCKING IN WALLS AS REQUIRED AT ALL WALL-MOUNTED ITEMS. VERIFY HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT. REFER TO METAL BACKING AND BLOCKING DETAIL ON A800.
C. CAULK ALL COUNTERTOPS, BACK SPLASHES, AND CABINETS AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-OUTS IN
COUNTERTOPS.
D. EPOXY FLOORING IN PATIENT RESTROOM SLOPES AT 1/4" PER FOOT - SEE DETAIL 4 ON SHEET AE502.
CEILING
WALL
FLOOR
BASE
WSF-1 ACT-1
WSF-1 P-1
F I N I S H K E Y
BUILDING 200
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1100 Boulders Pkwy | Suite 503 Richmond, VA 23225
804.355.2067
A u to d e s k D o c s /M t H o m e
I s o la ti o n W a rd
D
/F F
E
M t H o m e
D rv t
/1
/2
:0
:3
P
M
AI101
SECOND FLOOR FINISH PLAN
11/04/2022 ET TD
RENOVATE D-WING FOR ISOLATION
WARD
621-20-107
MOUNTAIN HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: MT Home VA
N
1/8" = 1'-0"
SECOND FLOOR FINISH PLAN
N
NTS
KEYPLAN
D R A W I N G N O T E S
1 EPOXY FLOORING ON BONDING AGENT/ADMIXTURE PRODUCT AND PRIMER. SLOPE TO DRAIN A MAXIMUM OF ¼” PER FOOT WITHIN THE TOILET/SHOWER AREA. PROVIDE A GENTLE TRANSITION SLOPE OF FINISHED EPOXY FLOOR WITHIN PATIENT ROOM TO EDGE OF SLIDING DOOR FRAME TO A MAXIMUM OF ¼” PER FOOT. MAINTAIN EPOXY FINISH FLOOR LEVEL AT ALUMINUM SLIDING DOOR AND FRAME LOCATION. COORDINATE FINISHED EPOXY FLOORING INSTALLATION
WITH SLIDING DOOR INSTALLATION.
No. Revisions: Date:
BID DOCUMENTS 11/04/2022
1 ADDENDUM #1 06/28/2023
2 ADDENDUM #2 07/13/2023
| Sheets |
| AI101 - SECOND FLOOR FINISH PLAN |
File details come from the government source that posted it. Updated .