08.00_AI101 - SECOND FLOOR FINISH PLAN-1.pdf

PDF 3 MB Posted

Attached to
Y1DZ--Project 621-20-107 Renovate Bldg. -200_Wing D2 for Isolation Ward
Solicitation number
36C24923R0030
Issued by

About this file

This document package includes plans for a federal construction project and the associated solicitation. The plans depict the second floor layout and finishes for renovating Building 200, Wing D2 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee to create an isolation ward. Key areas include 12 isolation rooms, toilet and anteroom spaces, support spaces for nourishment, soiled linen, clean linen, electrical and mechanical areas. The solicitation is for Project #621-20-107 to conduct these renovations. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The response due date is not provided. The plans include notes on finish materials, slopes and details.

View the file

Other files

File Type Posted
07.09_AE403 - CASEWORK ELEVATIONS.pdf PDF
P6.01 - PLUMBING DETAILS.pdf PDF
08.01_AI601 - FINISH SCHEDULE1.pdf PDF
FXD2.02 - SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN.pdf PDF
08.05_WP101 - WALL PROTECTION PLAN.pdf PDF
P2.01 - FIRST FLOOR PLUMBING NEW WORK PLAN 02.pdf PDF
P3.02 - SECOND FLOOR MEDICAL GAS NEW WORK PLAN.pdf PDF
000110 Table of Contents.pdf PDF
FX2.02 - SECOND FLOOR FIRE PROTECTION NEW WORK PLAN.pdf PDF
102600 Wall and Door Protection.pdf PDF
FX1.00 - FIRE PROTECTION LEGEND AND NOTES.pdf PDF
07.08_AE402 - CASEWORK ELEVATIONS.pdf PDF
36C24923R0030 0006.docx DOCX document
Addendum 02 Summary R1.pdf PDF
07.05_AC141 - SECOND FLOOR REFLECTED CEILING PLAN.pdf PDF
07.07_AE401 - ENLARGED RESTROOM PLANS AND ELEVATIONS.pdf PDF
087100 Door Hardware.pdf PDF
E3.02 - SECOND FLOOR LIGHTING NEW WORK PLAN.pdf PDF
36C24923R0030 0005.docx DOCX document
M2-02 - SECOND FLOOR HVAC NEW WORK PLAN.pdf PDF
36C24923R0030 0004.docx DOCX document
08.01_AI601 - FINISH SCHEDULE.pdf PDF
08.00_AI101 - SECOND FLOOR FINISH PLAN.pdf PDF
09.04_QT403 - ENLARGED EQUIPMENT PLAN.pdf PDF
36C24923R0030 0003.docx DOCX document
36C24923R0030 0002.docx DOCX document
36C24923R0030 0001.docx DOCX document
CALCULATION OF SELF PERFORMED WORK.docx DOCX document
Contractor EMR Certification Form.docx DOCX document
C27_UUpdated 621-20-107 Drawings Part 3 of 3.pdf PDF
C27_Updated 621-20-107 Drawings Part 2 of 3.pdf PDF
C27 Updated 621-20-107 Drawings Part 1 of 3.pdf PDF
UEI _ TAX ID.docx DOCX document
36C24923R0030_1.docx DOCX document
C28_621-20-107 Specifications.pdf PDF
P07_Wage Determination_621-20-107 Renovate Bldg.-200 - Wing D2 for Isolation Ward.pdf PDF
RFI Form.docx DOCX document
PERFORMANCE QUESTIONNAIRE.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P N M L K I H G F E C

35.1

D B.5 B A.5 A

30.1

32.8

O

ISO ROOM 1

D201B

RF-1 ACT-1

P-3RF-1

ISO ROOM 2

D202B

RF-1 ACT-1

P-3RF-1

ISO ROOM 3

D203B

RF-1 ACT-1

P-3RF-1

ISO ROOM 4

D204B

RF-1 ACT-1

P-3RF-1

ISO ROOM 5

D205B

RF-1 ACT-1

P-3RF-1

ISO ROOM 6

D206B

RF-1 ACT-1

P-3RF-1

ISO ROOM 7

D207B

RF-1 ACT-1

P-3RF-1

ISO ROOM 8

D208B

RF-1 ACT-1

P-3RF-1

ISO ROOM 9

D209B

RF-1 ACT-1

P-3RF-1 ISO ROOM 10

D210B

RF-1 ACT-1

P-3RF-1

ISO ROOM 11

D211B

RF-1 ACT-1

P-3RF-1

ISO ROOM 12

D212B

RF-1 ACT-1

P-3RF-1

TOILET

D201C

RF-2 P-6

PT-1RF-2

ANTEROOM

D201A

RF-1 ACT-1

P-3RF-1

TOILET

D202C

RF-1 P-6

PT-1RF-2

ANTEROOM

D202A

RF-1 ACT-1

P-3RF-1

TOILET

D204C

RF-1 P-6

PT-1RF-2

TOILET

D203C

RF-1 P-6

PT-1RF-2

ANTEROOM

D203A

RF-1 ACT-1

P-3RF-1

ANTEROOM

D204A

RF-1 ACT-1

P-3RF-1

ANTEROOM

D205A

RF-1 ACT-1

P-3RF-1

TOILET

D205C

RF-1 P-6

PT-1RF-2

TOILET

D-206C

RF-1 P-6

PT-1RF-2

ANTEROOM

D206A

RF-1 ACT-1

P-3RF-1

ANTEROOM

D207A

RF-1 ACT-1

P-3RF-1

TOILET

D208C

RF-1 P-6

PT-1RF-2

TOILET

D207C

RF-1 P-6

PT-1RF-2

ANTEROOM

D208A

RF-1 ACT-1

P-3RF-1

ANTEROOM

D209A

RF-1 ACT-1

P-3RF-1

TOILET

D210C

RF-1 P-6

PT-1RF-2

TOILET

D209C

RF-1 P-6

PT-1RF-2

ANTEROOM

D210A

RF-1 ACT-1

P-3RF-1

ANTEROOM

D211A

RF-1 ACT-1

P-3RF-1

TOILET

D212C

RF-1 P-6

PT-1RF-2

TOILET

D211C

RF-1 P-6

PT-1RF-2

ANTEROOM

D212A

RF-1 ACT-1

P-3RF-1

CHART ALCOVE

D201D

LVT-1 ACT-2

P-2RB-1

CHART ALCOVE

D203D

LVT-1 ACT-2

P-2RB-1

CHART ALCOVE

D205D

LVT-1 ACT-2

P-2RB-1

CHART ALCOVE

D207D

LVT-1 ACT-2

P-2RB-1

CHART ALCOVE

D209D

LVT-1 ACT-2

P-2RB-1

CHART ALCOVE

D211D

LVT-1 ACT-2

P-2RB-1

EQUIPMENT

D214

RF-1 ACT-2

P-3RB-1

ELECTRICAL

D233

RF-1 EXP

P-3RB-1

NOURISHMENT

D215

LVT-2 ACT-2

P-3RB-2

HUDDLE

D216

LVT-2 ACT-2

P-4RB-2

CLEAN

D219

RF-1 ACT-2

P-3RF-1

LINEN

D220

RF-1 ACT-2

P-3RF-1

SOILED

D221

RF-1 ACT-2

P-3RF-1

NURSE STATION

D223

LVT-1 ACT-2

P-2RB-1

OIT

D222

RF-1 EXP

P-3RF-1

MED

D224

LVT-2 ACT-2

P-3RB-2

NURSE MANAGER

D227

LVT-1 ACT-2

P-2RB-1

LAB ALCOVE

D226

LVT-1 ACT-2

P-2RB-1

BIOMED

D235

CPT-1 EXP

P-3RB-2

MECHANICAL

H.A.C.

STAIRS

S1

STAFF TOILET

D230

RF-1 P-6

PT-1RF-2

LOUNGE

D228

LVT-1 ACT-2

P-4RB-1

CORRIDOR

D2C3

LVT-1 ACT-2

*RB-1

RESTROOM

D218

RF-1 P-6

PT-1RF-2

ALCOVE

D217

LVT-1 P-5

P-2RB-1

ALCOVE

D213

LVT-1 P-5

P-2RB-1

WOMEN'S LOCKER

D231

LVT-2 ACT-2

P-4RB-2

MEN'S LOCKER

D232

LVT-2 ACT-2

P-4RB-2

STORAGE

D229

LVT-1 ACT-2

P-4RB-1

X-RAY ALCOVE

D225

LVT-1 P-5

P-2RB-1

PNEUMATIC TUBE

SHAFT

CORRIDOR

D2C5

LVT-1 ACT-2

*RB-1

CORRIDOR

CORRIDOR

D2C4B

LVT-1 ACT-2

*RB-1

CORRIDOR

D2C2

LVT-1 ACT-2

*RB-1

CORRIDOR

D2C1

LVT-1 ACT-2

*RB-1

CONSULT

D234

CPT-1 ACT-2

P-2RB-2

CORRIDOR

D2C3B

LVT-1 ACT-2

P-3RB-1

VESTIBULE

D236

ELEVATOR LOBBY

D2EL2

LVT-1 ACT-2

-RB-1

CORRIDOR

D2C3A

LVT-1 ACT-2

P-2RB-1

CORRIDOR

D2-C4A

LVT-1 ACT-2

-RB-1

SLOPE =

¼" / 1'-0"

AE502

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

SLOPE =

¼" / 1'-0"

1 1

1 1

9' - 6" 19' - 0" 1' - 8" 22' - 4" 22' - 6" 23' - 0" 22' - 6" 26' - 0" 26' - 0" 26' - 0" 10' - 0" 4' - 6" 10' - 3" 10' - 0" 10' - 0" 10' - 0"

1'

9'

9'

0"

6'

9'

G E N E R A L F I N I S H N O T E S

A. ALL WALLS SHALL BE PAINTED P-1 AND ALL CEILING SHALL BE PAINTED P-3 UNLESS OTHERWISE NOTED. REFER TO FINISH

PLAN/RCP FOR ACCENT WALLS/CEILINGS.

B. PROVIDE METAL BACKING AND / OR METAL BLOCKING IN WALLS AS REQUIRED AT ALL WALL-MOUNTED ITEMS. VERIFY HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT. REFER TO METAL BACKING AND BLOCKING DETAIL ON A800.

C. CAULK ALL COUNTERTOPS, BACK SPLASHES, AND CABINETS AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-OUTS IN

COUNTERTOPS.

D. EPOXY FLOORING IN PATIENT RESTROOM SLOPES AT 1/4" PER FOOT - SEE DETAIL 4 ON SHEET AE502.

CEILING

WALL

FLOOR

BASE

WSF-1 ACT-1

WSF-1 P-1

F I N I S H K E Y

BUILDING 200

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1100 Boulders Pkwy | Suite 503 Richmond, VA 23225

804.355.2067

A u to d e s k D o c s /M t H o m e

I s o la ti o n W a rd

D

/F F

E

M t H o m e

D rv t

/1

/2

:0

:3

P

M

AI101

SECOND FLOOR FINISH PLAN

11/04/2022 ET TD

RENOVATE D-WING FOR ISOLATION

WARD

621-20-107

MOUNTAIN HOME, TENNESSEE

BID DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

Approved: MT Home VA

N

1/8" = 1'-0"

SECOND FLOOR FINISH PLAN

N

NTS

KEYPLAN

D R A W I N G N O T E S

1 EPOXY FLOORING ON BONDING AGENT/ADMIXTURE PRODUCT AND PRIMER. SLOPE TO DRAIN A MAXIMUM OF ¼” PER FOOT WITHIN THE TOILET/SHOWER AREA. PROVIDE A GENTLE TRANSITION SLOPE OF FINISHED EPOXY FLOOR WITHIN PATIENT ROOM TO EDGE OF SLIDING DOOR FRAME TO A MAXIMUM OF ¼” PER FOOT. MAINTAIN EPOXY FINISH FLOOR LEVEL AT ALUMINUM SLIDING DOOR AND FRAME LOCATION. COORDINATE FINISHED EPOXY FLOORING INSTALLATION

WITH SLIDING DOOR INSTALLATION.

No. Revisions: Date:

BID DOCUMENTS 11/04/2022

1 ADDENDUM #1 06/28/2023

2 ADDENDUM #2 07/13/2023

Sheets
AI101 - SECOND FLOOR FINISH PLAN

File details come from the government source that posted it. Updated .