Attachment 7 668-18-109_Project Drawings 3 of 6.pdf

PDF 17 MB Posted

Attached to
Y1DA--CON-NRM 668-18-109 Refurbish and Upgrade Elevators in Bldg 1 and 27
Solicitation number
36C26024R0009
Issued by

About this file

This file attachment is related to a federal contract opportunity to refurbish and upgrade elevators in two buildings at a Veterans Affairs medical center. The solicitation number is 36C26024R0009 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20. The opportunity type is a solicitation to refurbish and upgrade elevators in Building 1 and Building 27 at the medical center. The file attachment appears to contain project drawings related to the elevator refurbishment and upgrade work being solicited. No pricing terms, response dates, or other contract details are provided in this attached file or associated opportunity description.

View the file

Other files

File Type Posted
Wage Determination 1.19.24.pdf PDF
36C26024R0009 0006.pdf PDF
36C26024R0009 0005.pdf PDF
Wage Determination 1.5.24.pdf PDF
Wage Determination 12.22.23.pdf PDF
36C26024R0009 0004.pdf PDF
36C26024R0009 0003.pdf PDF
36C26024R0009 0002.pdf PDF
36C26024R0009 0001.pdf PDF
WD 11.24.23.pdf PDF
668-18-109_Pre Bid Site Walk Sign In Sheet_2023.12.03.pdf PDF
Attachment 17 Security Requirements.pdf PDF
Attachment 18 Contractor Rules of Behavior.pdf PDF
Attachment 4 668-18-109_Supplement to SPEC 01 00 00 Part 1-6-I.pdf PDF
Attachment 10 668-18-109_Project Drawings 6 of 6.pdf PDF
Attachment 15 Wage Determination 11.17.23.pdf PDF
Attachment 2 668-18-109_Project Specifications 1 of 2_R1.pdf PDF
Attachment 5 668-18-109_Project Drawings 1 of 6.pdf PDF
Attachment 13 668-18-109_Lead Sampling Report.pdf PDF
Attachment 6 668-18-109_Project Drawings 2 of 6.pdf PDF
Attachment 19 Calculation of Self Performed Work REV 1.pdf PDF
36C26024R0009.pdf PDF
Attachment 12 668-18-109_Limited Asbestos Good Faith Survey - Addendum 1.pdf PDF
Attachment 16 Price Breakout.xlsx XLSX spreadsheet
Attachment 3 668-18-109_Project Specifications 2 of 2_R1.pdf PDF
Attachment 1 668-18-109_SOW-CON_2023-08-15.pdf PDF
Attachment 8 668-18-109_Project Drawings 4 of 6.pdf PDF
Attachment 11 668-18-109_Limited Asbestos Good Faith Survey.pdf PDF
Attachment 9 668-18-109_Project Drawings 5 of 6.pdf PDF
Attachment 14 668-18-109_DWG Clarification Document_2023-06-22.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E-001 GENERAL NOTES, ABBREVIATIONS AND LEGENDS

ED101-1 BUILDING 1 - BASEMENT FLOOR: ELECTRICAL DEMOLITION PLAN

ED101-2 BUILDING 1 - BASEMENT FLOOR: ELECTRICAL DEMOLITION PLAN

ED102 BUILDING 1 - FIRST FLOOR: ELECTRICAL DEMOLITION PLAN

ED103 BUILDING 1 - SECOND FLOOR: ELECTRICAL DEMOLITION PLAN

ED104 BUILDING 1 - THIRD FLOOR: ELECTRICAL DEMOLITION PLAN

ED105 BUILDING 1 - FOURTH FLOOR: ELECTRICAL DEMOLITION PLAN

ED106 BUILDING 1 - FIFTH FLOOR: ELECTRICAL DEMOLITION PLAN

ED107 BUILDING 1 - SIXTH FLOOR: ELECTRICAL DEMOLITION PLAN

ED108 BUILDING 1 - SEVENTH FLOOR: ELECTRICAL DEMOLITION PLAN

ED109 BUILDING 1 - EIGHTH FLOOR: ELECTRICAL DEMOLITION PLAN

ED110 BUILDING 1 - NINTH FLOOR: ELECTRICAL DEMOLITION PLAN

ED111 BUILDING 1 - MACHINE ROOM: ELECTRICAL DEMOLITION PLAN

ED112 BUILDING 27 - BASEMENT FLOOR: ELECTRICAL DEMOLITION PLAN (DEDUCTIVE BID ALTERNATE)

ED113 BUILDING 27 - FIRST FLOOR: ELECTRICAL DEMOLITION PLAN (DEDUCTIVE BID ALTERNATE)

ED114 BUILDING 27 - SECOND FLOOR: ELECTRICAL DEMOLITION PLAN (DEDUCTIVE BID ALTERNATE)

EP101-1 BUILDING 1 - BASEMENT FLOOR: POWER, LIGHTING, AND SPECIAL SYSTEMS PLAN

EP101-2 BUILDING 1 - BASEMENT FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP102 BUILDING 1 - FIRST FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP103 BUILDING 1 - SECOND FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP104 BUILDING 1 - THIRD FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP105 BUILDING 1 - FOURTH FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP106 BUILDING 1 - FIFTH FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP107 BUILDING 1 - SIXTH FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP108 BUILDING 1 - SEVENTH FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP109 BUILDING 1 - EIGHTH FLOOR: POWER AND SPECIAL SYSTEMS PLAN

EP110 BUILDING 1 - NINTH FLOOR: POWER, LIGHTING, AND SPECIAL SYSTEMS PLAN

EP111 BUILDING 1 - MACHINE ROOM: POWER AND SPECIAL SYSTEMS PLAN

EP112 BUILDING 27 - BASEMENT FLOOR: POWER AND SPECIAL SYSTEMS PLAN (DEDUCTIVE BID ALTERNATE)

EP113 BUILDING 27 - FIRST FLOOR: POWER AND SPECIAL SYSTEMS PLAN (DEDUCTIVE BID ALTERNATE)

EP114 BUILDING 27 - SECOND FLOOR: POWER, LIGHTING, AND SPECIAL SYSTEMS PLAN (DEDUCTIVE BID ALTERNATE)

EL111 BUILDING 1 - MACHINE ROOM: LIGHTING PLAN

E-501 ELECTRICAL DETAILS

E-601 BUILDING 1 - EXISTING PARTIAL ONE-LINE DIAGRAM

E-602 BUILDING 1 - REVISED PARTIAL ONE-LINE DIAGRAM

E-603 BUILDING 1 - ELECTRICAL LOAD SCHEDULES

E-604 BUILDING 1 - ELECTRICAL SCHEDULES

E-605 BUILDING 27 - EXISTING ONE-LINE DIAGRAM (DEDUCTIVE BID ALTERNATE)

E-606 BUILDING 27 - REVISED ONE-LINE DIAGRAM (DEDUCTIVE BID ALTERNATE)

E-607 BUILDING 27 - ELECTRICAL SCHEDULES (DEDUCTIVE BID ALTERNATE)

E-001

GENERAL NOTES, ABBREVIATIONS

AND LEGENDS

S H E E T I N D E X

THIS SHEET IS FOR REFERENCE ONLY AND ALL SYMBOLS, NOTES

AND ABBREVIATIONS MAY NOT APPLY TO THIS PROJECT

WALL MOUNTED TELECOMMUNICATIONS OUTLET. 18" AFF UON.

# = INDICATES QUANTITY OF VOICE AND DATA JACKS

COMMUNICATION OUTLETS

FOR ALL TELECOMMUNICATION OUTLETS, ROUTE 3/4" CONDUIT UNDERGROUND IF

NECESSARY AND STUB TO ACCESSIBLE CEILING SPACE WITH CABLING AS

DESCRIBED IN ELECTRICAL SPECIFICATIONS.

# - INDICATES QUANTITY OF VOICE AND DATA JACKS

OUTLET; LETTER INDICATES AS FOLLOWS:

A = AUDIO V = VIDEO I = INTERCOM

OUTLET, TELEVISION

BLANK = 4 11/16" MASTER ANTENNA OUTLET BOX W/BLANK COVER,

MTD. 18" AFF UNLESS OTHERWISE NOTED.

C = CAMERA (CCTV SYSTEM), MTD 18" AFF

M = MONITOR (CTTV SYSTEM).

INTERCOM; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

M-MASTER S-SUBSTATION

SHUNT TRIP PUSHBUTTON OR KEY-SWITCH

PANELBOARD, SWITCHBOARD, OR

SWITCHGEAR. DASHED BOX INDICATES

CODE REQUIRED WORKING CLEARANCE

HARDWIRED CONNECTION

THERMOSTAT

ST

T

VFD VARIABLE FREQUENCY DRIVE

DRAW OUT SWITCH/PLUG-RECEPTACLE

CONNECTION

NORMALLY OPEN CONTACT (WHEN

DE-ENERGIZED)

NORMALLY CLOSED CONTACT (WHEN

DE-ENERGIZED)

E L E C T R I C A L L E G E N D

CONDUIT OR EQUIPMENT TO BE REMOVED

HH

CONDUIT HOME RUN 3/4"C, 2#12 & 1#12 GND.

UNLESS SHOWN OTHERWISE. (EXAMPLE

SHOWN: TO PANEL L1, CIRCUIT 2)

L1-2

CONDUIT HOME RUN - SEE CONDUIT AND

WIRE SCHEDULE.

CONDUIT CONCEALED IN WALL, CEILING,

UNDER FLOOR, IN FLOOR SLAB, OR ROUTED

UNDERGROUND

CONDUIT EXPOSED

OVERHEAD ELECTRICAL

EXTRA-HARD USAGE FLEXIBLE CORD

FLEXIBLE CONDUIT

CONDUIT TURNED UP OR TOWARD

CONDUIT TURNED DOWN OR AWAY

CONDUIT CAPPED

CIRCUIT BREAKER, RATING/NO. OF

POLES WITH THERMAL MAGNETIC

CIRCUIT BREAKER TRIP, UNLESS

OTHERWISE NOTED

MANUAL OR AUTOMATIC

TRANSFER SWITCH.

JUNCTION BOX

HANDHOLE

TRANSFORMER

BATTERY

GROUND ROD IN GROUND ROD

BOX

CB

T

ROD SYMBOLS

EXISTING CONDUIT ROUTED UNDERGROUND, EXISTING TO

REMAIN UNLESS OTHERWISE NOTED

##NG

EXISTING CONDUIT EXPOSED, EXISTING TO REMAIN UNLESS

OTHERWISE NOTED

PHOTO ELECTRIC SENSOR

# NEW LUMINAIRE CONTROL. SEE LIGHTING CONTROL LEGEND

LOCATED ON LIGHTING SHEETS.

OS CEILING MOUNTED OCCUPANCY SENSOR(S). PROVIDE SHOP

DRAWINGS OF OCCUPANCY SENSOR SYSTEM AS PER PROJECT

SPECIFICATION AS PART OF THE SUBMITTAL PROCESS PRIOR TO

COMMENCEMENT OF LABOR. SEE LIGHTING CONTROL LEGEND

LOCATED ON LIGHTING SHEETS.

PE

SWITCH

2 = DOUBLE POLE SWITCH

3 = THREE WAY SWITCH

4 = FOUR WAY SWITCH

K = KEY OPERATED SWITCH

T = SWITCH WITH TIMER

MS = MASTER SWITCH TO CONTROL ALL FIXED

LUMINAIRES IN GUEST UNIT

X

LUMINAIRE, SURFACE

LUMINAIRE, RECESSED

STRIP, SURFACE

HALF SHADED FIXTURE DENOTES: EMERGENCY LUMINAIRE

LUMINAIRE, WALL MOUNT

EXIT SIGN, ARROW INDICATES DIRECTION

EMERGENCY WALL PACK

LUMINAIRE, POLE MOUNTED

LUMINAIRE, PENDANT MOUNTED

POWER

LUMINAIRES (DIMENSIONS OF SYMBOL WILL VARY DEPENDING ON LUMINAIRE)

LUMINAIRE TYPE IDENTIFICATION: LUMINAIRES INDICATED BY THE FOLLOWING NOTATIONS:

L# = NEW LUMINAIRE UON, REFER TO LUMINAIRE SCHEDULE FOR DETAILS

U# = NEW LUMINAIRE UON IN DWELLING UNIT, REFER TO LUMINAIRE SCHEDULE FOR DETAILS

S# = NEW LUMINAIRE UON, EXTERIOR SITE, REFER TO LUMINAIRE SCHEDULE FOR DETAILS

R# = EXISTING LUMINAIRE TO BE REMOVED, UNLESS OTHERWISE NOTED

ER# = EXISTING LUMINAIRE TO REMAIN

EL# = EXISTING LUMINAIRE TO BE RELOCATED

EN# = NEW LOCATION OF EXISTING LUMINAIRE

100/3

FLOOR MOUNTED TELECOMMUNICATIONS OUTLET.

# = INDICATES QUANTITY OF VOICE AND DATA JACKS

M

A B B R E V I A T I O N S

AFC

AFG

AF

AFCI

AFF

AIC

AHJ

ATS

C

CATV

CB

CCTV

CL

CO

DDC

DP

EC

EL

EM

EN

EMT

ER

EX

FAAP

FACP

FCIO

FOIC

GFCI

GFP

GND

HTR

IG

IMC

JBOX

LCP

MCA

MCB

MCC

MDP

MLO

MS

MTD

NAC

NEC

NFC

NIC

NL

NTS

OC

OH

OS

PIV

PNL

PS

PVC

R

RCPT

RMC

SAC

SB,SWBD

SG

SPD

ST

TEL

TR

TYP

UON

UL

UG

VD

VFD

W

WP

XFMR

AVAILABLE FAULT CURRENT

ABOVE FINISHED GRADE

AMP FRAME

ARC FLASH CIRCUIT INTERRUPTER

ABOVE FINISHED FLOOR

AMPERE INTERRUPTING CAPACITY

AUTHORITY HAVING JURISDICTION

AUTOMATIC TRANSFER SWITCH

CONDUIT OR CEILING

CABLE TELEVISION

CIRCUIT BREAKER

CLOSED CIRCUIT TELEVISION

CONNECTOR LIGHTING

CONDUIT ONLY

DIRECT DIGITAL CONTROLS

DISTRIBUTION PANELBOARD

ELECTRICAL CONTRACTOR

EXISTING TO BE RELOCATED

EMERGENCY

EXISTING IN NEW LOCATION

ELECTRICAL METALLIC TUBING

EXISTING TO REMAIN

EXISTING

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FURNISHED BY CONTRACTOR, INSTALLED

BY OWNER

FURNISHED BY OWNER, INSTALLED BY

CONTRACTOR

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT PROTECTION

GROUND

HEATER

ISOLATED GROUND

INTERMEDIATE METALLIC CONDUIT

JUNCTION BOX

LIGHTING CONTROL PANEL

MINIMUM CIRCUIT AMPACITY

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAIN DISTRIBUTION PANEL

MAIN LUGS ONLY

MOTOR STARTER

MOUNTED

NOTIFICATION APPLIANCE CABINET

NATIONAL ELECTRICAL CODE

NOT FOR CONSTRUCTION

NOT IN CONTRACT

NIGHT LIGHT

NOT TO SCALE

ON CENTER

OVERHEAD

OCCUPANCY SENSOR

POST INDICATOR VALVE

PANEL

POWER SUPPLY

POLYVINYL CHLORIDE

EXISTING TO BE REMOVED

RECEPTACLE

RIGID METAL CONDUIT

SMALL APPLIANCE CIRCUIT

SWITCHBOARD

SWITCHGEAR

SURGE PROTECTIVE DEVICE

SHUNT TRIP

TELEPHONE

TAMPER RESISTANT

TYPICAL

UNLESS OTHERWISE NOTED

UNDERWRITERS LABORATORIES

UNDERGROUND

VOLTAGE DROP

VARIABLE FREQUENCY DRIVE

WEATHERPROOF (WHILE IN USE)

WEATHERPROOF

TRANSFORMER

CS

WAP WIRELESS ACCESS PORT

WALL MOUNTED SPEAKER/CLOCK COMBINATION

C WALL CLOCK

CABLE TRAY

RECESSED AUDIO FLOOR BACK BOX, OUTLET AND CONDUITA/V

SPEAKER, CEILING MOUNTED

SPEAKER, WALL MOUNTED, MTD. 7'-6" AFF UON.

RADIO CHANNEL SELECTOR FACILITIES, MTD. 4'-6" AFF UON.

M = SPEAKER PROGRAM SELECTOR SWITCH & VOLUME CONTROL

3-POLE TWIST-LOCK RECEPTACLE FOR MICROPHONE,

MTD. 4'-6" AFF.

REMOTE DICTATING OUTLET MTD 1'-6" AFF. UON.

INTERCOM STATION (REFER TO SPECS. FOR FUNCTIONAL

OPERATION OF INSTRUMENT & TYPE REQUIRED).

S = STAFF STATION

FIBEROPTICS LINE = FO

TELEPHONE LINE = T

COMMUNICATION

LUMINAIRE, DOWNLIGHT

M

M

S

SPECIAL PURPOSE RECEPTACLE, RATING AS INDICATED

STANDARD RECEPTACLES: 125V, 20A 18" AFF, UON. TYPES:

SIMPLEX /DUPLEX /QUADRUPLEX /FLOOR DUPLEX /FLOOR

QUADRUPLEX

GFCI RECEPTACLES: 125V, 20A 18" AFF, UON. TYPES: SIMPLEX

/DUPLEX /QUADRUPLEX

C = CEILING MOUNTED

S = HALF SWITCHED

I = ISOLATED GROUND

TR = TAMPER RESISTANT

a = LOWER CASE LETTER INDICATES SWITCH

CONTROL

2" = MEASUREMENT INDICATES HEIGHT ABOVE

BACKSPLASH/MILLWORK

A = INDICATES MOUNT ABOVE

BACKSPLASH/MILLWORK. COORDINATE

HEIGHT WITH TRADES.

USB = INDICATES 20A 120V DUPLEX RECEPTACLE

WITH USB CHARGER.

CT = SWITCHED RECEP, INDICATES FULL

CONTROLLED DEDICATED 20A 125V DUPLEX

CH = SWITCHED RECEP, INDICATES HALF

CONTROLLED DEDICATED 20A 125V DUPLEX

200AS100AF

M

DISCONNECT SWITCH, FUSED

200=SWITCH RATING, 100=FUSE

RATING

DISCONNECT SWITCH, NON FUSED

(60A) INDICATES AMPERAGE

RATING

MAGNETIC MOTOR STARTER

W/DISCONNECT

MAGNETIC MOTOR STARTER

FVNR = FULL VOLTAGE

NON-REVERSING

FVR = FULL VOLTAGE

00 = NEMA SIZE

UTILITY WATT HOUR METER

60A

M

MOTOR RATED SWITCH. WHERE "M" INDICATED, PROVIDE A

MANUAL MOTOR STARTER W/OVERLOAD

CIRCUIT BREAKER DISCONNECT

(60A) INDICATES AMPERAGE

RATING60A

MOTOR

POWER (CONTINUED)

3 CURRENT TRANSFORMER,

NUMBER INDICATES NUMBER OF

C.T.'S

DUPLEX RECEPTACLE ON EMERGENCY POWER

3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &

RECEPTACLE

DROP CORD, SINGLE CONVENIENCE OUTLET

ELECTRICAL STRIP MOLD

ALARM, TAMPER SWITCH

DETECTION, GAS

DETECTOR, FLOW SWITCH

DETECTOR, HEAT

DETECTOR, SMOKE

DETECTOR, SMOKE, FOR DUCT

ELECTROMAGNETIC TYPE DOOR HOLDER OUTLET

CITY FIRE ALARM MASTER STATION MTD 5'-6" AFF UNLESS NOTED.

FIRE ALARM TRANSMITTER (BASE LOOP) NUMERALS DENOTE CODE.

FIRE ALARM TROUBLE TRANSMITTER (BASE LOOP) NUMERALS DENOTE

CODE.

KITCHEN HOOD FIRE SUPPRESSION SYSTEM

FIRE SPRINKLER WATER FLOW SWITCH

2-4-6

2-4-6

1. "GENERAL NOTES" APPLY TO ALL ELECTRICAL DRAWINGS. "SHEET NOTES" APPLY TO ONLY THE

SHEETS ON WHICH THEY OCCUR. "KEYNOTES" APPLY ONLY WHERE CALLED OUT.

2. ALL EQUIPMENT SHOWN IN BOLD IS TO BE PROVIDED, OR MODIFIED BY CONTRACTOR UNLESS

OTHERWISE NOTED.

3. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FROM ALL CONTROL DEVICES TO LUMINAIRES

FOR CONTROL OF LUMINAIRES SHOWN.

4. LUMINAIRES SHOWN ON DRAWINGS FOR QUANTITY AND CIRCUITING ONLY. SEE ARCHITECTURAL

DRAWINGS FOR EXACT LOCATIONS.

5. ALL FEEDERS AND BRANCH CIRCUITS SHALL CONTAIN AN EQUIPMENT GROUND CONDUCTOR

SIZED PER NEC TABLE 250.122. ALL WIRING IS BASED ON CU COPPER PER NEC TABLE 310.15(B)(16), USING 75°C AMPACITIES FOR FEEDERS.

6. BRANCH CIRCUIT CONDUCTORS, NOT OTHERWISE IDENTIFIED SHALL BE A MINIMUM 12 AWG FOR RUNS 70 FEET OR LESS AND A MINIMUM 10 AWG FOR RUNS GREATER THAN 70 FEET. QUANTITY AND SIZE SHALL BE "AS REQUIRED" TO SERVE AND CONTROL DEVICE(S) OR EQUIPMENT WITH A

MAXIMUM VOLTAGE DROP OF THREE PERCENT. WHERE CONTRACTOR CHOOSES TO RUN MORE

THAN THREE CURRENT CARRYING CONDUCTORS WITHIN ONE RACEWAY OR CABLE, CONDUCTORS

SHALL BE INCREASED IN SIZE TO COMPENSATE FOR THE DERATING REQUIRED PER NEC SECTION

310.15. CONDUCTOR AMPACITIES SHALL BE TAKEN FROM THE 75°C COLUMN.

7. MINIMUM CONDUIT IN EXTERIOR AND UNDERGROUND LOCATIONS TO BE 1" UNLESS NOTED

OTHERWISE ON PLANS. CONDUITS FROM LUMINAIRES TO LOCAL USER CONTROL DEVICES

(SWITCHES, OCCUPANCY SENSORS, ETC.) MAY BE 1/2" OR AS INDICATED IN SPECIFICATIONS.

PROVIDE ADDITIONAL CONDUCTOR FOR UNSWITCHED "HOT" TO LIGHTING LUMINAIRES WITH

EMERGENCY POWER BATTERIES OR GENERATOR TRANSFER DEVICES.

8. WIRING FOR EMERGENCY LIGHTING CIRCUITS OR OTHER EMERGENCY EQUIPMENT SHALL BE KEPT

ENTIRELY INDEPENDENT OF ALL OTHER WIRING AND EQUIPMENT AND SHALL MEET ALL

REQUIREMENTS OF NEC SECTION 700.10.

9. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FOR ALL CIRCUITS SHOWN ON DRAWINGS.

10. WHERE EQUIPMENT PART NUMBERS ARE SHOWN ON THESE PLANS THEY SHALL SUPERCEDE THE

REQUIREMENTS OF THE SPECIFICATIONS.

11. ALL CONDUITS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.

12. COORDINATE EXACT LOCATION OF ALL OUTLETS, COMBINATION CLOCK/SPEAKERS, SPEAKER, FA

DEVICES, ETC., WITH THE ARCHITECTURAL ELEVATIONS PRIOR TO COMMENCING WORK.

13. COORDINATE USE OF CEILING SPACE WITH ALL TRADES PRIOR TO COMMENCING WORK. MANY

AREAS ARE VERY CONGESTED AND REQUIRE CLOSE COORDINATION.

14. COORDINATE INSTALLATION REQUIREMENTS FOR OCCUPANCY SENSOR LIGHTING CONTROL WITH

THE MANUFACTURER. PROVIDE ALL APPURTENANCES AS REQUIRED BY THE MANUFACTURER.

PROVIDE ADDITIONAL SENSORS WHERE NECESSARY TO PROVIDE COMPLETE COVERAGE IN EACH

ROOM CONTROLLED BY OCCUPANCY SENSORS.

15. COORDINATE THE INSTALLATION OF ALL EXTERIOR OUTLET BOXES WITH THE TYPE OF MASONRY

IN EACH AREA. CUT ALL FLUTED BLOCKS SO THAT THE BOX IS INSTALLED FLUSH. SEE

ARCHITECTURAL DETAILS FOR MOUNTING REQUIREMENTS.

16. SEAL ALL CONDUIT PENETRATIONS OF FLOORS & FIRE RATED ASSEMBLIES WITH U.L. APPROVED

MATERIALS AND METHODS TO MAINTAIN FIRE RATING. PROTECT ALL OPENINGS FOR STEEL

ELECTRICAL BOXES IN FIRE RATED WALLS WITH U.L. APPROVED MATERIALS AND METHODS TO

MAINTAIN THE FIRE INTEGRITY.

17. PROVIDE ADDITIONAL CONDUIT SLEEVES THROUGH WALLS WHERE REQUIRED FOR ROUTING OF

SIGNAL SYSTEM WIRING NOT REQUIRED TO BE RUN IN CONDUIT. EACH SLEEVE SHALL BE

DEDICATED TO EACH SIGNAL SYSTEM. SLEEVES ROUTED THROUGH RATED WALLS SHALL BE

SEALED WITH U.L. MATERIALS AND METHODS TO MAINTAIN FIRE RATING OF WALL.

18. SEE MECHANICAL/PLUMBING DRAWINGS AND SUBMITTALS FOR EXACT LOCATIONS AND

ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION.

19. ALL LOW VOLTAGE SYSTEMS NOT RUN IN CONDUIT SHALL HAVE MINIMUM 3/4"C. ROUTED FROM

THE DEVICE THROUGH WALLS INTO THE ACCESSIBLE CEILING SPACE. NO CABLING SHALL BE

ROUTED IN THE WALLS OR INACCESSIBLE LOCATION WITHOUT CONDUIT.

20. GFCI RECEPTACLES ARE REQUIRED WITHIN 6 FT OF ALL SINKS, ON THE EXTERIOR BELOW 8 FT

FROM THE FINISH FLOOR, AND ON ALL ROOFS.

21. UNLESS SPECIFICALLY SHOWN ON THESE PLANS NO STRUCTURAL MEMBER SHALL BE CUT,

NEITHER DRILLED NOR NOTCHED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE

STRUCTURAL ENGINEER AND THE DIVISION OF THE STATE ARCHITECT.

G E N E R A L N O T E S

"a"

"NL"

"E"

INDICATES PANELBOARD AND CIRCUIT PROVIDING POWER TO

LUMINAIRES IN SAME ROOM/AREA, UON.

INDICATES TYPE PER LUMINAIRE SCHEDULE.

(SEE "LUMINAIRES" LEGEND ON THIS SHEET FOR MORE

INFORMATION)

INDICATES NIGHT LIGHT LUMINAIRE.

INDICATES CONTROL PER SWITCH.

INDICATES POWER TO EMERGENCY LIGHTING

CONTAINED IN SAME ROOM/AREA.

#ENLa

PNL-2

INDICATES CIRCUIT NUMBER.

INDICATES POWER SOURCE."PNL"

"2"

RECEPTACLE, TYPICAL:

LUMINAIRE, TYPICAL:

X-Xa/E

X-XE

X-Xa

X-X

C I R C U I T D E S I G N A T I O N

DETAIL1

SCALE

SECTION

A

XXX

A

XXX

XXX

XX

FIGURE OR PHOTO

DETAIL NUMBER

IF PHOTO, ARROW

DENOTES DIRECTION

TAKEN

DETAIL AREA

SHEET ON WHICH

SECTION APPEARS

SECTION LETTER

SHEET WHERE

SECTION IS TAKEN

FROM

SECTION LETTER

DETAIL NUMBER

XXX

DETAIL NUMBER

SHEET ON WHICH

DETAIL APPEARS

SHEET WHERE DETAIL

IS TAKEN FROM

CONDUIT &

WIRE TAG

FAULT CURRENT

TAG (AIC)

KEY NOTE

G E N E R A L S Y M B O L S

XX

NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER TOP UNLESS OTHERWISE

NOTED.

NURSE CALL TERMINAL CABINET.

NURSE CALL STATION.

2 = DUPLICATE FACILITIES FOR TWO BEDS (SEPARATE INDICATORS AT MASTER

STATION) MTD 5'-0" AFF UNLESS OTHERWISE NOTED.

D = DUTY STATION. MTD 5'-0" AFF UNLESS NOTED OTHERWISE.

E = MTD 6'-0" AFF FOR SHOWER LOCATION, MTD 4'-6" AFF FOR TUB LOCATION, & MTD

3'-0" AFF FOR TOILET LOCATION.

P = PSYCHIATRIC CORRIDOR STATION WITH KEY SWITCH

S = AUDIO VISUAL MALL STATION (STAFF) MTD 5'-0" AFF UNLESS OTHERWISE NOTED.

U = UTILITY CALL STATION, MTD 5'-0" AFF UNLESS OTHERWISE NOTED.

NURSE CALL STATION.

2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF LAMP) MTD 6" ABOVE DOOR.

D = CORRIDOR DOME LIGHT.

I = AUXILIARY INTERSECTIONAL DOME LIGHT.

NURSE CALL

FIRE ALARM

ALARM, FIRE, COMMUNICATOR

ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:

FACC = CENTRAL CONSOLE FACP = CONTROL PANEL

MFACP= MASTER CONTROL PANEL FAAP = ANNUNCIATOR PANEL

REMOTE ANNUNCIATOR

ADDRESSABLE RELAY

ALARM, FIRE; LETTERS INDICATE AS FOLLOWS:

BATT = BATTERIES CHR = CHARGER FAR = RECORDER

ALARM, FIRE, VALVE SUPERVISORY SWITCH.

ALARM, FIRE, TERMINAL CABINET.

ALARM, FIRE, POST INDICATOR VALVE.

ALARM, TRANSPONDER OR TRANSMITTER

ALARM, FIRE, MANUAL PULL STATION

ALARM, HORN/LIGHT, ONE ASSEMBLY

C = WITH CHIME

ALARM, HORN/LIGHT, SEPARATE ASSEMBLY

ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE

ALARM, MANUAL CONTROL

ALARM, MINI HORN

C

ALARM, SPRINKLER SYSTEM WATER FLOW BELL

ALARM, VOICE COMMUNICATION PANEL

SAFETY AND SECURITY

M = MOUNTING FOR ALL SAFETY AND SECURITY SYMBOLS:

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

SECURITY ACCESS, ANNUNCIATOR PANEL

SECURITY ACCESS, CONTROL UNIT WITH CLOSED CIRCUIT TELEVISION CAMERA

AP

SECURITY ACCESS, VIDEO CAMERA WITH LENS

SECURITY ACCESS, DOME CAMERA

M T

AUDIO DEVICE; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

B-BELL C-CHIME H-HORN K-KLAXON

L-LISTEN-IN M-MICROPHONE S-SOUNDER S-SPEAKER Z-BUZZER

M KEYPAD DEVICE

M CARD READER WITH KEYPAD

M T

CARD ACCESS READER; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

B-BARCODE F-ELEVATOR FLOOR CALL H-ELEVATOR HALL CALL

M-MAG STRIP P-PROXIMITY S-SMART CARD T-TOKEN

M T

ELECTRONIC LOCK; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

D-DEADBOLT H-HYBRID L-LATCH SET M-MAGNETIC S-STRIKE

M T

PUSH BUTTON; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

M T

DOOR CONTACT

PB PULL BOX

J

D

CP

WB

M

FTR

PIV

FATC

OSY

BATT

R

FACC

FAC

A

N

N

NCT

NCS

FTT

DH

FAT

HD

TS

K

F

R

R

S

S

B-BELL PUSH D-DURESS P-PANIC R-DOOR RELEASE X-REQUEST-FOR-EXIT

ELV-ELEVATOR LOBBY CONTROLS

EQUIPMENT CORD

FS

X

ST

ST

EQUIPMENT RACK

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

- Spokane, WA

LRL/WNM JPS/FEB 104 OF 143

CB-A2S3 P1

P2

AREA OF WORK

S

S

KEY NOTES

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

EXISTING SUMP PUMP TO BE

DEMOLISHED AND REPLACED.

COORDINATE WITH MECHANICAL AND

ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION.

EXISTING ELEVATOR PIT LIGHTING TO

BE REPLACED WITH NEW LIGHTING.

REFERENCE SHEET EP101-1 FOR

ADDITIONAL INFORMATION.

SHEET NOTES

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES, ELEVATOR PIT

LIGHTING AND EQUIPMENT, AND

FIELD DEVICES AS REQUIRED.

BUILDING 1 - BASEMENT FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED101-1

BUILDING 1 - BASEMENT FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

AREA OF WORK

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

- Spokane, WA

LRL/WNM JPS/FEB

EQ-3

EQ-1

UPS2

TRANSFORMER

RECT.

JB

AHU

X

X

X

X

X

X

X

PANEL BEQ1

XFMRXRAYA

XFMRXRAYB

CEILING

MOUNTED

PULL BOX

B016

B014B

B014A

B005

B014 B012

B010

B008

BATT

UPS1

MIB

SW

BD

'A'

AREA OF

WORK

UPS

UPS

SPACE TAKEN UP BY

EXISTING MECH/ELECT

EQUIPMENT

KEY PLAN

ED101-2

BUILDING 1 - BASEMENT FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY NOTES

EXISTING PANELBOARD "EQ-3" TO BE

REVISED TO PROVIDE LSIG ELEVATOR

FEEDER CIRCUIT BREAKER. REFERENCE

ONE-LINE DIAGRAMS ON DRAWINGS E-601

AND E-602 FOR ADDITIONAL INFORMATION.

EXISTING PANELBOARD "EQ-1" TO BE

REVISED TO PROVIDE LSIG ELEVATOR

FEEDER CIRCUIT BREAKER. REFERENCE

ONE-LINE DIAGRAMS ON DRAWINGS E-601

AND E-602 FOR ADDITIONAL INFORMATION.

EXISTING PULL BOX TO REMAIN; PRESERVE

AND PROTECT.

EXISTING RACEWAYS TO REMAIN; PRESERVE

AND PROTECT. EXISTING CONDUCTORS

WITHIN RACEWAY TO BE DEMOLISHED IN

THEIR ENTIRETY AND REPLACED.

EXISTING SWITCHBOARD "SWBD-A" TO BE

REVISED TO PROVIDE LSIG ELEVATOR

FEEDER CIRCUIT BREAKER. REFERENCE

ONE-LINE DIAGRAMS ON DRAWINGS E-601

AND E-602 FOR ADDITIONAL INFORMATION.

BUILDING 1 - BASEMENT FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/4" = 1'-0"

KEY PLAN

0 2' 4' 8'

Scale: 1/4" = 1'-0"

NN

SHEET NOTES

1. SWITCHBOARD 'A' IS NOT LOCATED AT THE

SAME ELEVATION AS ROOM B010.

SWITCHBOARD 'A' IS LOCATED AT GROUND

LEVEL, WHILE ROOM B010 IS LOCATED IN

THE BASEMENT OF THE BUILDING, BELOW

GROUND LEVEL.

AREA OF

WORK

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 106 OF 143

A119 A103

A119

S3 P1

P2

AREA OF WORK

S

KEY NOTES

SHEET NOTES

BUILDING 1 - FIRST FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED102

BUILDING 1 - FIRST FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

AREA OF

WORK

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 107 OF 143

A211

A237

A212 A235

S3 P1

P2

AREA OF WORK

S

S

KEY NOTES

SHEET NOTES

AREA OF

WORKBUILDING 1 - SECOND FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED103

BUILDING 1 - SECOND FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 108 OF 143

A-331

S3 P1

P2

AREA OF WORK

S

WAP

KEY NOTES

SHEET NOTES

BUILDING 1 - THIRD FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

AREA OF WORK

ED104

BUILDING 1 - THIRD FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 109 OF 143

A425 C4-A2

A423

S3 P1

P2

AREA OF WORK

S

AREA OF WORKBUILDING 1 - FOURTH FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED105

BUILDING 1 - FOURTH FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

KEY NOTES

SHEET NOTES

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 110 OF 143

A529

A500B

C5-A2

A527

S3 P1

P2AREA OF WORK

S

AREA OF WORKBUILDING 1 - FIFTH FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED106

BUILDING 1 - FIFTH FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

KEY NOTES

SHEET NOTES

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 111 OF 143

A600

A633

A637

A604S3 P1

P2

A635

A603

AREAS OF WORK

S

KEY NOTES

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL

DRAWINGS FOR MORE INFORMATION.

EXISTING DATA RACK.

EXISTING DATA RACK TO BE SALVAGED

BY OWNER.

EXISTING 1.5 KVA UPS.

EXISTING NURSE CALL EQUIPMENT.

EXISTING TELECOM BACKBOARD.

EXISTING CEILING MOUNTED HVAC UNIT

(1/6 HP) TO BE DEMOLISHED. EXISTING

CONDUIT AND WIRE TO REMAIN FOR

REPLACEMENT UNIT.

SHEET NOTES

BUILDING 1 - SIXTH FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED107

BUILDING 1 - SIXTH FLOOR: ELECTRICAL

DEMOLITION PLAN

AREAS OF WORK

KEY PLAN

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 112 OF 143

A729

C7-A1

S3 P1

P2

S S

AREA OF WORK

AREA OF WORKBUILDING 1 - SEVENTH FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED108

BUILDING 1 - SEVENTH FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

KEY NOTES

SHEET NOTES

EXISTING PASSENGER ELEVATOR CAB

"P1" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB

"P2" TO BE REPLACED. ALL

ASSOCIATED CONDUCTORS AND FIELD

DEVICES SHALL BE DEMOLISHED BACK

TO ITS SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES

SHALL BE DEMOLISHED BACK TO ITS

SOURCE. EXISTING ASSOCIATED

RACEWAYS TO REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK

SHALL BE PROTECTED IN PLACE OR

REMOVED AND REINSTALLED AFTER

COMPLETION OF ARCHITECTURAL

WORK AS REQUIRED. REFERENCE

ARCHITECTURAL DRAWINGS FOR MORE

INFORMATION.

1. REFERENCE ARCHITECTURAL

DRAWINGS AND ELEVATOR

SPECIFICATIONS FOR ADDITIONAL

DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING ELEVATOR LOBBY

LUMINAIRES AND FIELD DEVICES

AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

LRL/WNM JPS/FEB 113 OF 143

A800D

A800AA800C

S3 P1

P2

S

WAP

S

AREA OF WORK

AREA OF WORKBUILDING 1 - EIGHTH FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED109

BUILDING 1 - EIGHTH FLOOR:

ELECTRICAL DEMOLITION PLAN

KEY PLAN

KEY NOTES

SHEET NOTES

EXISTING PASSENGER ELEVATOR CAB "P1"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES SHALL

BE DEMOLISHED BACK TO ITS SOURCE.

EXISTING ASSOCIATED RACEWAYS TO

REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB "P2"

TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES SHALL

BE DEMOLISHED BACK TO ITS SOURCE.

EXISTING ASSOCIATED RACEWAYS TO

REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3" TO

BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES SHALL

BE DEMOLISHED BACK TO ITS SOURCE.

EXISTING ASSOCIATED RACEWAYS TO

REMAIN FOR REUSE.

EXISTING LUMINAIRES, FIRE ALARM

DEVICES, CAMERAS, AND ANY OTHER

ELECTRICAL EQUIPMENT LOCATED IN

ELEVATOR LOBBY AREA OF WORK SHALL

BE PROTECTED IN PLACE OR REMOVED

AND REINSTALLED AFTER COMPLETION OF

ARCHITECTURAL WORK AS REQUIRED.

REFERENCE ARCHITECTURAL DRAWINGS

FOR MORE INFORMATION.

EXISTING PANEL "8LS1" TO BE MODIFIED.

REFERENCE SHEET E-604 FOR

ADDITIONAL INFORMATION.

EXISTING CARD READER COMMUNICATION

CABINET TO BE DEMOLISHED AND

REPLACED. DEMOLISH CONDUIT AND WIRE

ASSOCIATED WITH CABINET. CONDUIT

AND WIRE ASSOCIATED WITH EXISTING

CARD READERS SHALL BE PRESERVED

FOR REUSE WITH NEW CABINET.

1. REFERENCE ARCHITECTURAL DRAWINGS

AND ELEVATOR SPECIFICATIONS FOR

ADDITIONAL DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY ALL

EXISTING ELEVATOR LOBBY LUMINAIRES

AND FIELD DEVICES AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

- Spokane, WA

LRL/WNM JPS/FEB

A900

S3 P1

P2 4

HD

HD

AREA OF WORK

KEY NOTES

SHEET NOTES

AREA OF WORKBUILDING 1 - NINTH FLOOR: ELECTRICAL DEMOLITION PLAN

Scale: 1/2" = 1'-0"

ED110

BUILDING 1 - NINTH FLOOR:

ELECTRICAL DEMOLITION PLAN

EXISTING PASSENGER ELEVATOR CAB "P1" TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES SHALL BE DEMOLISHED BACK TO ITS SOURCE.

EXISTING ASSOCIATED RACEWAYS TO REMAIN FOR REUSE.

EXISTING PASSENGER ELEVATOR CAB "P2" TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES SHALL BE DEMOLISHED BACK TO ITS SOURCE.

EXISTING ASSOCIATED RACEWAYS TO REMAIN FOR REUSE.

EXISTING SERVICE ELEVATOR CAB "S3" TO BE REPLACED. ALL ASSOCIATED

CONDUCTORS AND FIELD DEVICES SHALL BE DEMOLISHED BACK TO ITS SOURCE.

EXISTING ASSOCIATED RACEWAYS TO REMAIN FOR REUSE.

EXISTING EQUIPMENT POWER PANELBOARD "9EQ4" TO BE MODIFIED. REFERENCE

LOAD SCHEDULES ON SHEET E-604 FOR MORE INFORMATION.

EXISTING NORMAL POWER PANELBOARD "9N1" TO BE MODIFIED. REFERENCE LOAD

SCHEDULES ON SHEET E-604 FOR MORE INFORMATION.

EXISTING EQUIPMENT POWER PANELBOARD "9EQ2".

EXISTING MOTOR CONTROL CENTER "MCC3".

EXISTING SWITCHBOARD "9EQ1" TO BE MODIFIED. REFERENCE LOAD SCHEDULES ON

SHEET E-603 FOR ADDITIONAL INFORMATION.

EXISTING FIRE ALARM FIELD DEVICES TO BE DEMOLISHED AND REPLACED.

EXISTING ELEVATOR TOP OF SHAFT LIGHTING TO BE REPLACED WITH NEW LIGHTING.

REFERENCE SHEET EP110 FOR ADDITIONAL INFORMATION.

KEY PLAN

1. REFERENCE ARCHITECTURAL DRAWINGS AND ELEVATOR SPECIFICATIONS FOR

ADDITIONAL DEMOLITION INFORMATION.

2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING ELEVATOR LIGHTING, RECEPTACLES,

AND FIELD DEVICES AS REQUIRED.

0 1' 2' 4'

Scale: 1/2" = 1'-0" N0 1' 2' 4'

Scale: 1/2" = 1'-0" N

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

A/E:

625 First Ave #301 Seattle, WA, 98104

(206) 590 - 2118

RAY SPEES, PRESIDENT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

668-18-109

Revisions: Date:

SPEES DESIGN BUILD

REFURBISH AND UPGRADE

ELEVATORS IN BLDG

1 AND 27

11/16/2021

Mann-Grandstaff VA Medical Center

- Spokane, WA

LRL/WNM JPS/FEB

File details come from the government source that posted it. Updated .