Att. 10 - Set 8 of 8 Final Drawings By Building 590 22 700.pdf
PDF 37 MB Posted
- Attached to
- Y1DA--590-22-700 | Construct EHRM Infrastructure Upgrade | Hampton, VA | Federal contract opportunity
- Solicitation number
- 36C77626R0041
About this file
This file is a set of final construction drawings for the EHRM Infrastructure Upgrades project at Hampton VA Medical Center in Hampton, Virginia. The document is the 8th set of 8 drawing packages containing detailed architectural, engineering, and technology plans for multiple buildings (137, 138, 138A, 144, and 146) involved in the renovation project.
The drawings encompass comprehensive infrastructure upgrades including telecommunications and data network installations across the campus. Key work involves upgrading all telecommunications cabling from Category 6 and below to Category 6A (CAT6A) throughout the buildings, installing fiber optic backbone cables (OS2 24-strand fiber cables designated as Core A and Core B) routed through new conduit systems and cable trays, and establishing multiple telecommunications rooms (TRs) with fiber distribution cabinets. The project specifies 24-strand OS2 fiber optic cables connecting to Building 135, with new cable tray systems, pull boxes, and fire-stop sleeves at penetrations. Construction documents are dated July 18, 2025, for 100% completion stage, prepared by IMEG Corporation and Stamp Consultant. Work includes phasing plans showing ICRA (Infection Control Risk Assessment) classifications and coordination requirements with the VA for room closures to complete data wiring, with demolition of existing equipment and infrastructure as needed. The project address is 509-22-700 EHRM, located at Hampton VA Medical Center, Hampton, Virginia.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
TR
A85
PHYSICIAN
A89
B
A
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
K
TR
A85
B
A
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
DD
TR
B105B
STAIRWELL
NO. 1
BS1
B
A1
WORK IN ROOM
BY OTHER
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
DD
TR
B105B
STAIRWELL
NO. 1
BS1
B
A
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-2025
REGIS
TE
R
ED
CO
MMUNICA T IONS DISTRIBUT IO
N
DESIGNER
RCDD
225 W WASHINGTON STREET
SUITE 2700
CHICAGO, IL 60606
P: 312.294.0501 F: 312.294.0003 www.imegcorp.com
PROJECT #22010109.00
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/1
/2
:4
:1
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /5
-7
.B
.T R
.r v t
137T-400
BLDG.137 TECHNOLOGY ENLARGED PLANS
EW IMEG
100% CONSTRUCTION
DOCUMENTS
05/09/2025
509-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
N O R
HT
1/2" = 1'-0"
TELECOM ROOM ENLARGEMENT PLAN TR #A85
N O R
HT
1/2" = 1'-0"
TELECOM ROOM PATHWAY PLAN TR #A85
N O R
HT
1/2" = 1'-0"
TELECOM ROOM ENLARGEMENT PLAN - TR #B105B
N O R
HT
1/2" = 1'-0"
TELECOM ROOM PATHWAY PLAN - TR #B105B
NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR ROOM LAYOUT AND RACK ELEVATIONS.
2. ROUTE OPTICAL FIBER CABLE TO OVERHEAD CABLE TRAY AND TERMINATE IN FIBER DISTRIBUTION CABINET.
KEYNOTES:
1. THROUGH WALL PENETRATION FOR BACKBONE CONDUIT. OPTICAL FIBER CABLE CONTINUES ON CABLE TRAY TO RACKS.
NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR ROOM LAYOUT AND RACK ELEVATIONS.
2. ROUTE OPTICAL FIBER CABLE TO OVERHEAD CABLE TRAY AND TERMINATE IN FIBER DISTRIBUTION CABINET.
KEYNOTES:
1. THROUGH WALL PENETRATION FOR BACKBONE CONDUIT. OPTICAL FIBER CABLE CONTINUES ON CABLE TRAY TO RACKS.
Revisions: Date: 601 of 713
FIBER
DISTRIBUTION
CABINET
FIBER
DISTRIBUTION
CABINET
FIBER
DISTRIBUTION
CABINET
TELECOMMUNICATIONS ROOM TR-137-##
24 STRANDS OS2 FIBER OPTIC
CABLE, CORE "A" , TO BUILDING 135
24 STRANDS OS2 FIBER OPTIC
CABLE, CORE "B" , TO BUILDING 135
CHANNEL RACK
LEVEL 01
TR #B105B
TELECOMMUNICATIONS ROOM TR #A85
24 STRANDS OS2 FIBER OPTIC
CABLE, CORE "A" , TO BUILDING 135
24 STRANDS OS2 FIBER OPTIC
CABLE, CORE "B" , TO BUILDING 135
CHANNEL RACK
LEVEL 01
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT
SHOW ACTUAL ROUTING OR QUANTITIES OF
MATERIALS SHOWN. THIS RISER IS SHOWN FOR
CLARIFICATION OF CONNECTION(S), LOCATIONS
AND CABLE TYPE. ALL INFORMATION OUTLETS
ARE TYPICAL OF THE OUTLETS IN THE AREA
SHOWN. REFER TO FLOOR PLANS FOR MORE
SPECIFIC ROUTING INFORMATION. REFER TO
SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
2. REFER TO ELECTRICAL DRAWINGS FOR CHANNEL
RACK AND FIBER OPTIC DISTRIBUTION CABINET
SPECIFICATIONS
TELECOMMUNICATIONS ROOM TR #1C142
24 STRANDS OS2 FIBER OPTIC
CABLE, CORE "A" , TO BUILDING 135
24 STRANDS OS2 FIBER OPTIC
CABLE, CORE "B" , TO BUILDING 135
CHANNEL RACK
LEVEL 01
N
TR
1C142
A
B
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
N
TR
1C142
A
B
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
F G
TR
C175
STORAGE ROOM
C177
A
B
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
F G
TR
C175
STORAGE ROOM
C177
A
B
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (A)
(1) 4"C - (1) 24-STRAND OS2 FIBER CABLE (B)
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-2025
REGIS
TE
R
ED
CO
MMUNICA T IONS DISTRIBUT IO
N
DESIGNER
RCDD
225 W WASHINGTON STREET
SUITE 2700
CHICAGO, IL 60606
P: 312.294.0501 F: 312.294.0003 www.imegcorp.com
PROJECT #22010109.00
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/1
/2
:4
:1
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /5
-7
.B
.T R
.r v t
137T-401
BLDG.137 TECHNOLOGY ENLARGED PLANS
EW IMEG
100% CONSTRUCTION
DOCUMENTS
05/09/2025
509-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR ROOM LAYOUT AND RACK ELEVATIONS.
2. ROUTE OPTICAL FIBER CABLE TO OVERHEAD CABLE TRAY AND TERMINATE IN FIBER DISTRIBUTION CABINET.
KEYNOTES:
1. THROUGH WALL PENETRATION FOR BACKBONE CONDUIT. OPTICAL FIBER CABLE CONTINUES ON CABLE TRAY
TO RACKS.
NO SCALE
FIBER RISER DIAGRAM
N O R
HT
1/2" = 1'-0"
TELECOM ROOM PATHWAY TR #1C142
N O R
HT
1/2" = 1'-0"
TELECOM ROOM ENLARGEMENT PLAN TR #1C142
N O R
HT
1/2" = 1'-0"
TELECOM ROOM ENLARGEMENT PLAN TR #C175
N O R
HT
1/2" = 1'-0"
TELECOM ROOM PATHWAY TR #C175
NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR ROOM LAYOUT AND RACK ELEVATIONS.
2. ROUTE OPTICAL FIBER CABLE TO OVERHEAD CABLE TRAY AND TERMINATE IN FIBER DISTRIBUTION CABINET.
KEYNOTES:
1. THROUGH WALL PENETRATION FOR BACKBONE CONDUIT. OPTICAL FIBER CABLE CONTINUES ON CABLE TRAY
TO RACKS.
Revisions: Date: 602 of 713
27B
27 31
27A
110A
110B
110D
13W
148-D
148-S
148-A
148T
146B
146A
138A136
137A
137C
137D
137B
137C
148B
173A
148-C
170 150
110C
143 167
G R
A V
E L
R O
A D
FRANKLIN BOULEVARD
FRANKLIN BOULEVARD
AVERILL AVENUE
AVERILL AVENUE
A M
E S
S T
R E
E T
HARRIS AVENUE
JONES CREEK
K N
O X S
T R
E E
T
T H
O M
P S
O N
S T
R E
E T
F R A N
K
LI
N B
O U
LE
V A R
D
MALLORY STREET
M A
R T
IN
L. K
IN
G
JR
. B O
U L E
V A R
D
M A R
TIN
L. K
IN
G
JR
. B O U
LE
V
AR
D
E M
A N
C
IP
A T
IO
N D
R
SHORE ROAD
H A R R
IS
A V E N
U E
HARRIS AVENUE
M c C
L E
L L A
N
S E
W E
LL
A
V E
N U
E
A V
E N
U E
KEY AREA SHOWN
TRUE
NORTH
A B C D E F G H I
146 SF
GROUP ROOM
AG34
103 SF
CASE MGR,
SUICIDE PREV
AG32
189 SF
CORRIDOR
CG04
103 SF
HBPC, CLINICAL
PSYCH
AG30
103 SF
BUPRENORPHINE
PRGM, NP
AG28
97 SF
WAITING AREA
AG26
108 SF
WWII WOUNDED
WARRIORS
AG24
69 SF
CORRIDOR
CG03 112 SF
PSYCHOLOGIST
FELLOW
AG22
47 SF
COMM CLOSET
AG20
46 SF
MECHANICAL
ROOM
AG18
104 SF
EXAM ROOM
AG16
60 SF
M/F TOILET
AG14
104 SF
EXAM ROOM
AG12
172 SF
C&P
PSYCHOLOGIST
AG10
357 SF
CORRIDOR
CG02
117 SF
ADDICTION
THERAPIST
AG08
121 SF
OCCUPATIONAL
THERAPIST
AG06
147 SF
CORRIDOR
CG01
132 SF
C&P
PSYCHOLOGIST
AG07
132 SF
C&P
PSYCHOLOGIST
AG17
132 SF
PSYCHOLOGIST
FELLOW
AG19
132 SF
BUPRENORPHINE
SOCIAL WORKER
AG23
132 SF
SUICIDE PREV
COORDINATOR
AG35
132 SF
OEF-OIF MED
FOSTER CARE
AG37
132 SF
POLYTRAUMA
PSYCH
AG39
132 SF
POLYTRAUMA
COORDINATOR
AG05
316 SF
CORRIDOR
CG05
123 SF
POLYTRUMA
CASE MGR
AG36
118 SF
DR. SUBSTANCE
ABUSE PRGM
AG38
118 SF
BURPENORPHINE
PRGM PHYSICIAN
AG40
43 SF
FEMALE TOILET
AG01A
43 SF
MALE TOILET
AG01B
140 SF
LOBBY
AG01
138 SF
RECEPTION AREA
AG02
139 SF
WAITING ROOM
AG04
FE
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
BUILDING 138
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/0 /2
:4
:1 a m
B
IM
/5
-2
-7
V A
H a m p to n
E H
R M
/B L D
G
.r v t
138AS101
BUILDING 138 - LEVEL 01 - PHASING PLAN
MA CA
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
LEGENDLEGEND
KEY PLAN
1/4" = 1'-0"
BUILDING 138 - LEVEL 01 - PHASING PLAN
PROJECT
NORTH
0' 2' 4' 8'
NOTE:
BUILDING TO BE DEMOLISHED. DUCT BANK AND HANDHOLDS TO
BUILDING 138 SHALL BE PROVIDED TO SERVE FUTURE BUILDING IN THIS SITE.
Revisions: Date: 603 of 713
27B
27 31
27A
110A
110B
110D
13W
148-D
148-S
148-A
148T
146B
146A
138A 138136
137A
137C
137D
137B
137C
148B
173A
148-C
170 150
110C
143 167
G R
A V
E L
R O
A D
FRANKLIN BOULEVARD
FRANKLIN BOULEVARD
AVERILL AVENUE
AVERILL AVENUE
A M
E S
S T
R E
E T
HARRIS AVENUE
JONES CREEK
K N
O X S
T R
E E
T
T H
O M
P S
O N
S T
R E
E T
F R A N
K
LI
N B
O U
LE
V A R
D
MALLORY STREET
M A
R T
IN
L. K
IN
G
JR
. B O
U L E
V A R
D
M A R
TIN
L. K
IN
G
JR
. B O U
LE
V
AR
D
E M
A N
C
IP
A T
IO
N D
R
SHORE ROAD
H A R R
IS
A V E N
U E
HARRIS AVENUE
M c C
L E
L L A
N
S E
W E
LL
A
V E
N U
E
A V
E N
U E
KEY AREA SHOWN
TRUE
NORTH
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
A B C D E F G
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA
FOR ROOM CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN THIS AREA.
226 SF
GROUP ROOM
BG02
110 SF
WAITING ROOM
BG01
133 SF
EXAM ROOM
BG05
130 SF
OFFICE
BG04
127 SF
OFFICE
BG06
129 SF
OFFICE
BG08
130 SF
OFFICE
BG10
139 SF
OFFICE
BG12
187 SF
CORRIDOR
CG10
149 SF
CORRIDOR
CG11
106 SF
OFFICE
CG06
114 SF
OFFICE
CG08
116 SF
OFFICE
CG07
124 SF
OFFICE
CG09
421 SF
RECREATION
AREA
CG13
166 SF
CHECK IN
CG12
60 SF
BATHROOM
CG14
333 SF
MULTI-PURPOSE
ROOM
CG15
225 SF
CLASSROOM
CG16
167 SF
BREAK ROOM
BG11
128 SF
OFFICE
BG09
362 SF
CORRIDOR
CGB1
52 SF
DATA CLOSET
BG07A
22 SF
ELECTRICAL
CLOSET
BG07
116 SF
ROOM
BG01.1
BUILDING 138A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/0 /2
:4
:4 a m
B
IM
/5
-2
-7
V A
H a m p to n
E H
R M
/B L D
G
A
.r v t
138AAS100
BUILDING 138A - LEVEL 00 - PHASING PLAN
138A
MA CA
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
LEGENDLEGEND
KEY PLAN
3/16" = 1'-0"
BUILDING 138A - LEVEL 00 - PHASING PLAN
0' 2' 4' 8'
PROJECT
NORTH
FE FE
FE
Revisions: Date: 604 of 713
WAP WAP
WAP
WAP
WAP
WAP
WAP
A B C D E F G H I
138TN401
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE SERVED
FROM TELECOMMUNICATIONS ROOM 90A IN BUILDING 146A.
138TN401
GROUP
ROOM
AG34
CASE MGR,
SUICIDE
PREV
AG32
CORRIDOR
CG04
HBPC,
CLINICAL
PSYCH
AG30
BUPRENORPHINE
PRGM, NP
AG28
WAITING
AREA
AG26
WWII
WOUNDED
WARRIORS
AG24
CORRIDOR
CG03
PSYCHOLOGIST
FELLOW
AG22
COMM
CLOSET
AG20
MECHANICAL
ROOM
AG18
EXAM ROOM
AG16
M/F TOILET
AG14
EXAM ROOM
AG12
C&P
PSYCHOLOGIST
AG10
CORRIDOR
CG02
ADDICTION
THERAPIST
AG08
OCCUPATIONAL
THERAPIST
AG06
CORRIDOR
CG01
C&P
PSYCHOLOGIST
AG07
C&P
PSYCHOLOGIST
AG17
PSYCHOLOGIST
FELLOW
AG19
BUPRENORPHINE
SOCIAL
WORKER
AG23
SUICIDE
PREV
COORDINATOR
AG35
OEF-OIF
MED
FOSTER
CARE
AG37
POLYTRAUMA
PSYCH
AG39
POLYTRAUMA
COORDINATOR
AG05
CORRIDOR
CG05
POLYTRUMA
CASE MGR
AG36
DR.
SUBSTANCE
ABUSE
PRGM
AG38
BURPENORPHINE
PRGM
PHYSICIAN
AG40
FEMALE
TOILET
AG01A
MALE
TOILET
AG01B
LOBBY
AG01
RECEPTION
AREA
AG02
WAITING
ROOM
AG04
2 2
DD3 DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3 DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3DD3
DD3
DD3
DD3
TYP.
TYP.
1N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2 N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2N2
N2
N2
N2 N2
N2
N2
N2
N2
N2
N2
N2 N2
N2
N2
N2 N2N2
N2N2N2
N2
138TN401
138TN401
BLDG 138
Y
D# N#
Y
D# N#
OUTLET, DATA OR VOIP TELEPHONE. THE FOLLOWING INFORMATION
INDICATED ON THE SYMBOL:
"#" = QUANTITY OF OUTLET PORTS.
"D" = EXISTING CABLES TO BE DEMOLISHED.
"N" = REPLACEMENT CABLES TO BE PROVIDED.
REFERENCE SHEET TNG002 FOR ADDITIONAL INFORMATION.
AREA SHOWN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/1
/2
:2
:5
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /E
E
B L D
G
.r v t
138TN101
BLDG 138 - LEVEL 01 - TELECOMMUNICATIONS
PLAN
KG BCL/GPB
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
- 1/4" = 1'-0"
1 BLDG 138 - LEVEL 01 - TELECOMMUNICATIONS PLAN 2'0 4' 8'
PROJECT
NORTH
TRUE
NORTH
GENERAL NOTES
KEY PLAN
KEY NOTES
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER AND SIGNAL DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE
NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, FINISHES AND THE LIKE, SHALL BE
REPAIRED OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING, IF REQUIRED. COORDINATE WITH ARCHITECTURAL
DRAWINGS AS REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING. PROVIDE RACEWAYS TO EXTEND TO ASSOCIATED TR.
6. A TELECOMMUNICATIONS OUTLET UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING EXISTING DEVICES AND CABLES; PROVIDING ALL LABOR,
MATERIALS, TOOLS, TEST INSTRUMENTS, AND CONSUMABLES REQUIRED FOR THE
INSTALLATION, TERMINATION, TESTING, LABELING, AND CERTIFICATION OF A FULLY
FUNCTIONAL CATEGORY 6A OUTLET WITH THE PORT QUANTITY INDICATED.
7. WHERE NEW DATA OUTLETS ARE BEING PROVIDED AND EXISTING DATA OUTLET
CURRENTLY DOES NOT EXIST, PROVIDE (1) 1" CONDUIT FROM NEW BACKBOX TO
ACCESSIBLE CEILING SPACE TO SECURELY ROUTE DATA CABLING FROM OUTLET TO
TR VIA CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND RACEWAY FROM
OUTLET TO TR AS REQUIRED.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION
OF HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL
IN AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250 INCH (6.35mm) (4) CAT6A CABLES WITH AN 0.250 INCH (6.35mm) OD OR
SMALLER CAN BE INSTALLED IN A ¾” CONDUIT SUPPORTING A 40% FILL RATIO.
12. CONTRACTOR TO BID AN ADDITIONAL 10% OF THE TOTAL NUMBER OF WAO's PER
FLOOR. A WAO IS DEFINED AS TWO CAT6A OUTLETS.
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE DETAIL '1' ON SHEET TN501 AND
THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION. COORDINATE
WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FED WITH (2) CAT6A CABLES.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON SHEET TN501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET TN701. WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO
HORIZONTAL FIRE STOP SLEEVES [(2) 4", MINIMUM]. WHERE EXISTING CABLE TRAY IS
PRESENT, IT SHALL BE DEMOLISHED AND REPLACED AS INDICATED. EXISTING SLEEVES
MAY BE UTILIZED IF SUITABLE FOR REUSE, BUT NOT IN PLACE OF FIRE STOP SLEEVES
AS MENTIONED ABOVE. WHERE CLEARANCES OR OBSTRUCTIONS DO NOT PERMIT
INSTALLATION OF CABLE TRAY, PROVIDE J-HOOKS AS REQUIRED FOR CABLE
DISTRIBUTION.
Revisions: Date: 605 of 713
WAP
360°
360°
WAP
WAP
360°
WAP
AREA SHOWN
A B C D E F G
TYP.
C
C
DD2
DD2
DD2DD2
DD2
DD2
DD2
DD2
DD2
DD2
DD2
DD2DD2
DD2
DD2
DD2
DD2
DD2DD2
DD2
DD2
DD2
TYP.
DD2
DD2
DD2
DD2
N2
N2N2N2
N2
N2 N2
N2
N2
N2
N2
N2
N2N2
N2N2
N2N2
N2
N2
N2
N2
N2
N2
N2
N2
DD2
DD2
N2
N2
DD2
N2
DD2
N2
GROUP
ROOM
BG02
WAITING
ROOM
BG01
EXAM ROOM
BG05
OFFICE
BG04
OFFICE
BG06
OFFICE
BG08
OFFICE
BG10
OFFICE
BG12
CORRIDOR
CG10
CORRIDOR
CG11
OFFICE
CG06
OFFICE
CG08
OFFICE
CG07
OFFICE
CG09
RECREATION
AREA
CG13
CHECK IN
CG12
BATHROOM
CG14
MULTI-PURPOSE
ROOM
CG15
CLASSROOM
CG16
BREAK
ROOM
BG11
OFFICE
BG09
CORRIDOR
CGB1
DATA
CLOSET
BG07A
ELECTRICAL
CLOSET
BG07
ROOM
BG01.1
BLDG 138A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/1
/2
:2
:4
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /E
E
B L D
G
A
.r v t
138ATN100
BLDG 138A - LEVEL 00 -
TELECOMMUNICATIONS PLAN
138A
KG BCL/GPB
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
- 1/8" = 1'-0"
1 BLDG 138A - LEVEL 00 - TELECOMMUNICATIONS PLAN
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE SERVED
FROM TELECOMMUNICATIONS ROOM 90A IN BUILDING 146A.
4'0 8' 16'
PROJECT
NORTH
Revisions: Date:
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE DETAIL '1' ON SHEET TN501 AND
THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION. COORDINATE
WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FED WITH (2) CAT6A CABLES.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON SHEET TN501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET TN701. WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO
HORIZONTAL FIRE STOP SLEEVES [(2) 4", MINIMUM]. WHERE EXISTING CABLE TRAY IS
PRESENT, IT SHALL BE DEMOLISHED AND REPLACED AS INDICATED.
EXISTING SLEEVES MAY BE UTILIZED IF SUITABLE FOR REUSE, BUT NOT IN PLACE OF
FIRE STOP SLEEVES AS MENTIONED ABOVE. WHERE CLEARANCES OR OBSTRUCTIONS
DO NOT PERMIT INSTALLATION OF CABLE TRAY, PROVIDE J-HOOKS AS REQUIRED FOR
CABLE DISTRIBUTION.
KEY PLAN
KEY NOTES
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER AND SIGNAL DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE
NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, FINISHES AND THE LIKE, SHALL BE
REPAIRED OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING, IF REQUIRED. COORDINATE WITH ARCHITECTURAL
DRAWINGS AS REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING. PROVIDE RACEWAYS TO EXTEND TO ASSOCIATED TR.
6. A TELECOMMUNICATIONS OUTLET UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING EXISTING DEVICES AND CABLES; PROVIDING ALL LABOR,
MATERIALS, TOOLS, TEST INSTRUMENTS, AND CONSUMABLES REQUIRED FOR THE
INSTALLATION, TERMINATION, TESTING, LABELING, AND CERTIFICATION OF A FULLY
FUNCTIONAL CATEGORY 6A OUTLET WITH THE PORT QUANTITY INDICATED.
7. WHERE NEW DATA OUTLETS ARE BEING PROVIDED AND EXISTING DATA OUTLET
CURRENTLY DOES NOT EXIST, PROVIDE (1) 1" CONDUIT FROM NEW BACKBOX TO
ACCESSIBLE CEILING SPACE TO SECURELY ROUTE DATA CABLING FROM OUTLET TO
TR VIA CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND RACEWAY FROM
OUTLET TO TR AS REQUIRED.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION
OF HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL
IN AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250 INCH (6.35mm) (4) CAT6A CABLES WITH AN 0.250 INCH (6.35mm) OD OR
SMALLER CAN BE INSTALLED IN A ¾” CONDUIT SUPPORTING A 40% FILL RATIO.
12. CONTRACTOR TO BID AN ADDITIONAL 10% OF THE TOTAL NUMBER OF WAO's PER
FLOOR. A WAO IS DEFINED AS TWO CAT6A OUTLETS.
TRUE
NORTH
GENERAL NOTES
W W
D
39 SF
COMM CLOSET
AG20
TELECOM
PANEL
TELEPHONE
TERMINAL
BOARDS
TELEPHONE
DATA RACK
D
39 SF
COMM CLOSET
AG20
FIRE ALARM
PANEL
TELECOM
PANEL
TELEPHONE
TERMINAL
BOARDS
TELEPHONE
D
39 SF
COMM CLOSET
AG20 2
TYP.
AG20
D
39 SF
COMM CLOSET
AG20
AREA SHOWN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/1
/2
:2
:0
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /E
E
B L D
G
.r v t
138TN401
BLDG 138 - LEVEL 01 - ENLARGED
TELECOMMUNICATIONS PLANS
KG BCL/GPB
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
KEY PLAN
GENERAL NOTES
PROJECT
NORTH
EXISTING DATA RACK TO BE DECOMMISIONED BY VA. CONTRACTOR SHALL
COORDINATE WITH VA AS REQUIRED.
EXISTING CABLE TRAY TO BE DEMOLISHED.
EXISTING HORIZONTAL CABLING SLEEVE TO BE PRESERVED. EXISTING FIBER OPTIC
AND/OR EXISTING VERTICAL CABLING RELATED TO EXISTING TR RACKS TO BE
DEMOLISHED.
1/2" = 1'-0"138TN101
1 RM AG20 - DEMOLITION FLOOR PLAN
1/2" = 1'-0"138TN101
2 RM AG20 - TELECOMMUNICATIONS PLAN
1/2" = 1'-0"138TN101
3 RM AG20 - DEMOLITION OVERHEAD PLAN
1/2" = 1'-0"138TN101
4 RM AG20 - OVERHEAD PLAN1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
KEY NOTES
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER AND SIGNAL DEVICES AND ASSOCIATED CIRCUITRY AS
REQUIRED. ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO
BE DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, FINISHES AND THE LIKE, SHALL BE
REPAIRED OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE
ACCEPTANCE OF THE OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING, IF REQUIRED. COORDINATE WITH ARCHITECTURAL
DRAWINGS AS REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED.
6. A TELECOMMUNICATIONS OUTLET UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING EXISTING DEVICES AND CABLES; PROVIDING ALL LABOR,
MATERIALS, TOOLS, TEST INSTRUMENTS, AND CONSUMABLES REQUIRED FOR THE
INSTALLATION, TERMINATION, TESTING, LABELING, AND CERTIFICATION OF A FULLY
FUNCTIONAL CATEGORY 6A OUTLET WITH THE PORT QUANTITY INDICATED.
7. WHERE NEW DATA OUTLETS ARE BEING PROVIDED AND EXISTING DATA OUTLET
CURRENTLY DOES NOT EXIST, PROVIDE (1) 1" CONDUIT FROM NEW BACKBOX TO
ACCESSIBLE CEILING SPACE TO SECURELY ROUTE DATA CABLING FROM OUTLET TO
TR VIA CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND RACEWAY FROM
OUTLET TO TR AS REQUIRED.
8. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION
OF HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL
IN AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
9. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL
SYSTEMS. WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN
RACEWAY. WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL
SYSTEMS CABLE TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS;
ADDITIONALLY, CABLE TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS
REQUIRED TO SEGREGATE SYSTEMS FROM ONE ANOTHER.
10. ALL TELECOMMUNICATION ROOMS SHALL BE PROVIDED WITH FIRE-RATED PLYWOOD
BACKBOARDS. REFERENCE EXACT PLACEMENTS WITH ARCHITECTURE DRAWINGS
AS REQUIRED.
Revisions: Date: 607 of 713
27B
27 31
27A
110A
110B
110D
13W
148-D
148-S
148-A
148T
146B
146A
138A 138136
137A
137C
137D
137B
137C
148B
173A
148-C
170 150
110C
143 167
G R
A V
E L
R O
A D
FRANKLIN BOULEVARD
FRANKLIN BOULEVARD
AVERILL AVENUE
AVERILL AVENUE
A M
E S
S T
R E
E T
HARRIS AVENUE
JONES CREEK
K N
O X S
T R
E E
T
T H
O M
P S
O N
S T
R E
E T
F R A N
K
LI
N B
O U
LE
V A R
D
MALLORY STREET
M A
R T
IN
L. K
IN
G
JR
. B O
U L E
V A R
D
M A R
TIN
L. K
IN
G
JR
. B O U
LE
V
AR
D
E M
A N
C
IP
A T
IO
N D
R
SHORE ROAD
H A R R
IS
A V E N
U E
HARRIS AVENUE
M c C
L E
L L A
N
S E
W E
LL
A
V E
N U
E
A V
E N
U E
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
1 HR FIRE BARRIER
A B C D E F
121 SF
MHC SOC
WRK TEAM 2
109 SF
MHC
PYSCHOL
TEAM 2
116 SF
MHC SOC
WRK TEAM 2
225 SF
MHC PYSCH
TEAM 2
122 SF
MHC SUP
TEAM 2
106 SF
MHC PYSCH
RES
107 SF
MHC NURSE
TEAM 3
111 SF
MHC PYSCH
TEAM 3
109 SF
MHC
PYSCHOL
TEAM 3
110 SF
MHC
PYSCHOL
111 SF
MHC SOC
WORK
TEAM 3
125 SF
TELECOM
107 SF
HSKP / STOR.
104 SF
PLUMBING
189 SF
MHAC
GROUP 1
195 SF
MHAC
GROUP 2
50 SF
ELEV
MACH
213 SF
ART
THERAPY /
GROUP
208 SF
ART
THERAPY /
GROUP
157 SF
ART
THERAPY /
GROUP
148 SF
ART
THERAPY /
GROUP
212 SF
RECEPT
109B
108 SF
MHC NURSE
TEAM 4
112 SF
MHC NURSE
TEAM 5
108 SF
MHC SOC
WORK TEAM
111 SF
MHC
PYSCHOL
TEAM 5
109 SF
MHC SOC
WRK TEAM 4
110 SF
MHC SUPP
TEAM 5
73 SF
MSA SUP
109A
109 SF
MHC
PYSCHOL
TEAM 4
109C
110 SF
MHC PYSCH
TEAM 5
52 SF
TOILET
102C
50 SF
TOILET
102D
53 SF
TOILET
80 SF
SUIC PREV
CSWKR
78 SF
SUIC PREV
CSWKR
110 SF
MHC
PYSCHOL
TEAM 4
110 SF
MHC PYSCHO
TEAM 4
84 SF
ELEC
54 SF
SOILED
STORAGE
113 SF
MHC NURSE
TEAM 1
113 SF
MHC SOC
WORK
TEAM 1
98 SF
MHC SUPP
TEAM 4
98 SF
PHARM
218 SF
PYSCHOL
STUDENTS
94 SF
MHC SOC
WRK TEAM 5
96 SF
MHC SOC
WRK TEAM 5
92 SF
MHC
PYSCHOL
TEAM 5
123 SF
MHC EXAM
189 SF
NURSE
WRK/TRIAGE
424 SF
MSA HUB
109E
118 SF
MHC SOC
WORK
TEAM 1
118 SF
MHC
PYSCHOL
TEAM 1
118 SF
MHC
PYSCHOL
TEAM 1
120 SF
MHC
PYSCHOL
TEAM 1
111 SF
MHC
SUPP
TEAM 1
166 195 SF
STAFF
BREAK
110 SF
MHC
PYSCHOL
TEAM 2
187 SF
MSA HUB
109 SF
MHC SOC
WORK
TEAM 3
111 SF
MHC SUPP
TEAM 3
51 SF
SPKLR
RISER
SR-1
227 SF
STAIR #1
S1-1
102 SF
VEST
98 SF
VENDING
102A
972 SF
WAITING
110 SF
SUIC PREV
CS WKR
109F
110 SF
SUIC PREV
MSA
108 SF
SUIC PREV
COORD
215 SF
MAIN ELEC
154 SF
HALL
C1-2
199 SF
HALL
C1-1
173 SF
HALL
C1-4
183 SF
HALL
C1-5
229 SF
HALL
C1-3
128 SF
HALL
C1-6
308 SF
HALL
C1-7
377 SF
HALL
C1-9
200 SF
HALL
C1-8
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA
FOR ROOM CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN THIS AREA.
SECTION 1B:
CONTRACTOR TO COORDINATE WITH VA
FOR ROOM CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN THIS AREA.
FE
FE
FE
FE
FE
222 SF
STAIR
109D
KEY AREA SHOWN
TRUE
NORTH
BUILDING 144
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/0 /2
:4
:3 a m
B
IM
/5
-2
-7
V A
H a m p to n
E H
R M
/B L D
G
.r v t
144AS101
BUILDING 144 - LEVEL 01 - PHASING PLAN
MA ME
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
LEGEND
KEY PLAN
1" = 10'-0"
BUILDING 144 - LEVEL 01 - PHASING PLAN
PROJECT
NORTH
0' 5' 10' 20'
Revisions: Date: 608 of 713
DN
27B
27 31
27A
110A
110B
110D
13W
148-D
148-S
148-A
148T
146B
146A
138A 138136
137A
137C
137D
137B
137C
148B
173A
148-C
170 150
110C
143 167
G R
A V
E L
R O
A D
FRANKLIN BOULEVARD
FRANKLIN BOULEVARD
AVERILL AVENUE
AVERILL AVENUE
A M
E S
S T
R E
E T
HARRIS AVENUE
JONES CREEK
K N
O X S
T R
E E
T
T H
O M
P S
O N
S T
R E
E T
F R A N
K
LI
N B
O U
LE
V A R
D
MALLORY STREET
M A
R T
IN
L. K
IN
G
JR
. B O
U L E
V A R
D
M A R
TIN
L. K
IN
G
JR
. B O U
LE
V
AR
D
E M
A N
C
IP
A T
IO
N D
R
SHORE ROAD
H A R R
IS
A V E N
U E
HARRIS AVENUE
M c C
L E
L L A
N
S E
W E
LL
A
V E
N U
E
A V
E N
U E
A B C D E F
104 SF
ELEC
134 SF
RECEPT
202A
121 SF
TELECOM
315 SF
PTSD.
GROUP 3
104 SF
PTSD.
PSYCH.
323 SF
HALL
C2-9
773 SF
WAIT
110 SF
MHICM
PSYCH
87 SF
PTSD. TMS
95 SF
OBSERV
128 SF
VIRTUAL
PTSD
112 SF
MHICM NUR
110 SF
MHICM SOC.
WRK.
159 SF
MHICM
CROUP
111 SF
MHICM SOC.
WRK.
109 SF
MHICM EXAM
119 SF
MHICM SOC.
WRK.
101 SF
MHICM SOC.
WRK.
209 SF
STAIR # 2
S2-2
121 SF
OFF. SOC.
WRK.
104 SF
PTSD. NURSE
113 SF
OEF. SOC.
WRK.
178 SF
PTSD. SOC.
WRK.
107 SF
PTSD. NURSE
98 SF
PTSD.
PSYCHOL
23669 SF
WORK
57 SF
TLT
107 SF
PTSD.
PSYCHOL
57 SF
TLT
96 SF
PTSD.
PSYCHOL
55 SF
TLT
101 SF
PTSD.
PSYCHOL
164 SF
MHICM
GROUP
285 SF
PTSD GROUP
281 SF
PTSD GROUP
92 SF
PTSD.
PSYCHOL
99 SF
WKR
99 SF
PTSD. SOC.
WKR.
53 SF
TLT
202C
53 SF
TLT.
202B
221 SF
STAIR # 1
S2-1
132 SF
PTSD.
PSYCHOL
248 125 SF
PTSD.
PSYCH. RES.
114 SF
PTSD.
PSYCH. RES.
109 SF
PTSD.
PSYCH. RES.
115 SF
PTSD.
PSYCH. RES.
177 SF
STAFF
BREAK
102 SF
OEF.
PSYCHOL.
106 SF
PTSD.
PSYCHO
113 SF
PTSD.
PSYCHOL.
173 SF
PTSD.
COORD/DIRECT
109 SF
PTSD.
PSYCHOL.
109 SF
PTSD.
PSYCHOL.
111 SF
PTSD.
PSYCHOL.
111 SF
PTSD.
PSYCH.
402 SF
PTSD.
GROUP 4
371 SF
PTSD. / OEF
GROUP
130 SF
HALL
C2-4
298 SF
HALL
C2-3
218 SF
HALL
C2-2
239 SF
HALL
C2-7
135 SF
HALL
C2-8
309 SF
HALL
C2-5
FE
FE
FE
FE
FE
97 SF
PTSD.
SOC. WKR
108 SF
HALL
C2-1
130 SF
HALL
109G
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA
FOR ROOM CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN THIS AREA.
SECTION 1B:
CONTRACTOR TO COORDINATE WITH VA
FOR ROOM CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN THIS AREA.
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
1 HR FIRE BARRIER
KEY AREA SHOWN
TRUE
NORTH
BUILDING 144
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/0 /2
:4
:3 a m
B
IM
/5
-2
-7
V A
H a m p to n
E H
R M
/B L D
G
.r v t
144AS102
BUILDING 144 - LEVEL 02 - PHASING PLAN
MA ME
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
1" = 10'-0"
BUILDING 144 - LEVEL 02 - PHASING PLAN
LEGEND
KEY PLAN
PROJECT
NORTH
0' 5' 10' 20'
Revisions: Date: 609 of 713
A B C D E F
MSA SUP
109A
MHC SOC
WRK TEAM 2
MHC
PYSCHOL
TEAM 2
MHC SOC
WRK TEAM 2
MHC PYSCH
TEAM 2
MHC SUP
TEAM 2
MHC PYSCH
RES
MHC NURSE
TEAM 3
MHC PYSCH
TEAM 3
MHC
PYSCHOL
TEAM 3
MHC
PYSCHOL
MHC SOC
WORK
TEAM 3
TELECOM
HSKP / STOR.
PLUMBING
MHAC
GROUP 1
MHAC
GROUP 2
ELEV
MACH
ART
THERAPY /
GROUP
ART
THERAPY /
GROUP
ART
THERAPY /
GROUP
ART
THERAPY /
GROUP
RECEPT
109B
MHC NURSE
TEAM 4
MHC NURSE
TEAM 5
MHC SOC
WORK TEAM
MHC
PYSCHOL
TEAM 5
MHC SOC
WRK TEAM 4
MHC SUPP
TEAM 5
MHC
PYSCHOL
TEAM 4
109C
MHC PYSCH
TEAM 5
TOILET
102C
TOILET
102D
TOILET
SUIC PREV
CSWKR
SUIC PREV
CSWKR
MHC
PYSCHOL
TEAM 4
MHC PYSCHO
TEAM 4
ELEC
SOILED
STORAGE
MHC NURSE
TEAM 1
MHC SOC
WORK
TEAM 1
MHC SUPP
TEAM 4
PHARM
PYSCHOL
STUDENTS
MHC SOC
WRK TEAM 5
MHC SOC
WRK TEAM 5
MHC
PYSCHOL
TEAM 5
MHC EXAM
NURSE
WRK/TRIAGE
MSA HUB
109E
MHC SOC
WORK
TEAM 1
MHC
PYSCHOL
TEAM 1
MHC
PYSCHOL
TEAM 1
MHC
PYSCHOL
TEAM 1
MHC
SUPP
TEAM 1
STAFF
BREAK
MHC
PYSCHOL
TEAM 2
MSA HUB
MHC SOC
WORK
TEAM 3
MHC SUPP
TEAM 3
SPKLR
RISER
SR-1
STAIR #1
S1-1VEST
VENDING
102A
WAITING
SUIC PREV
CS WKR
109F
SUIC PREV
MSA
SUIC PREV
COORD
MAIN ELEC
HALL
C1-2
HALL
C1-1
HALL
C1-4
HALL
C1-5
HALL
C1-3
HALL
C1-6
HALL
C1-7
HALL
C1-9
HALL
C1-8
Room
STAIR
109D
144T-400
TR-144-149
(1) 4"C - (1) 24 STRAND
OS2 FIBER CABLE (A)
AND (1) 4"C - SPARE
HANDHOLE
A
A
DASHED OUTLINE
OF TR #251 AT
FLOOR ABOVE
4"C - (1) 24
STRAND OS2
FIBER CABLE (A)
B B
4"C - (1) 24 STRAND
OS2 FIBER CABLE (B)
B
HANDHOLE
PULLBOX, TYP.
REFER TO TS01 FOR
CONTINUATION
(1) 4"C - (1) 24 STRAND
OS2 FIBER CABLE AND
(1) 4"C - SPARE
144T-400
(1) 4"C - (1) 24 STRAND OS2 FIBER CABLE (B)
(1) 4"C - (1) 24 STRAND OS2 FIBER CABLE (A)
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-2025
REGIS
TE
R
ED
CO
MMUNICA T IONS DISTRIBUT IO
N
DESIGNER
RCDD
225 W WASHINGTON STREET
SUITE 2700
CHICAGO, IL 60606
P: 312.294.0501 F: 312.294.0003 www.imegcorp.com
PROJECT #22010109.00
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/2
/2
:0
:3
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /5
-7
.B
.T R
.r v t
144T-101
LEVEL 01 PLAN - TECHNOLOGY
EW IMEG
100% CONSTRUCTION
DOCUMENTS
05/09/2025
509-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
N O R
HT
1/8" = 1'-0"
LEVEL 01 PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO SITEPLAN TS001 FOR ADDITIONAL INFORMATION.
2. REFER TO T500 AND T501 FOR CAMPUS OPTICAL FIBER CABLE
RISER DIAGRAMS.
3. REFER TO 2/T400 FOR HANDHOLE DETAIL.
4. NEW BACKBONE OPTICAL FIBER CABLES SHALL BE
INDOOR/OUTDOOR TYPE.
5. ALL BACKBONE OPTICAL FIBER CABLE PATHWAYS SHALL BE NEW.
DO NOT RE-USE EXISTING BACKBONE CABLE PATHWAYS FOR NEW
BACKBONE CABLES.
6. TRANSITION PVC CONDUITS TO GRC IN CRAWL SPACE OR
EXPOSED EXTERIOR LOCATIONS. TRANSITION TO EMT CONDUITS
AT INTERIOR OF BUILDING. SEAL ALL PENETRATIONS TO MAINTAIN
FIRE-RATINGS OF WALL, CEILING AND FLOORS.
KEYNOTES:
1. PROVIDE PULLBOX ON EXTERIOR WALL AT HEIGHT OF FIRST
FLOOR CEILING. ROUTE CONDUIT FROM HANDHOLE UP WALL
INTO PULLBOX. PROVIDE PENETRATIONS THRU WALLS AND
CONTINUE ROUTE ABOVE CORRIDOR FINISHED CEILING OVER
INTO TR #149.
2. ROUTE CONDUITS INTO TR #149 AT ABOVE HEIGHT OF CABLE
TRAY. PROVIDE PULLBOX AND ROUTE CONDUIT TO LOCATION
BELOW TR #251. PROVIDE PENETRATIONS THRU CEILING DECK
AND ROUTE CONDUITS UP INTO TR #251.
Revisions: Date: 610 of 713
A B C D E F
97 SF
PTSD.
SOC. WKR
104 SF
ELEC
134 SF
RECEPT
202A
121 SF
TELECOM
315 SF
PTSD.
GROUP 3
104 SF
PTSD.
PSYCH.
323 SF
HALL
C2-9
773 SF
WAIT
110 SF
MHICM
PSYCH
87 SF
PTSD. TMS
95 SF
OBSERV
128 SF
VIRTUAL
PTSD
112 SF
MHICM NUR
110 SF
MHICM SOC.
WRK.
159 SF
MHICM
CROUP
111 SF
MHICM SOC.
WRK.
109 SF
MHICM EXAM
119 SF
MHICM SOC.
WRK.
101 SF
MHICM SOC.
WRK.
209 SF
STAIR # 2
S2-2
121 SF
OFF. SOC.
WRK.
104 SF
PTSD. NURSE
113 SF
OEF. SOC.
WRK.
178 SF
PTSD. SOC.
WRK.
107 SF
PTSD. NURSE
98 SF
PTSD.
PSYCHOL
69 SF
WORK
57 SF
TLT
107 SF
PTSD.
PSYCHOL
57 SF
TLT
96 SF
PTSD.
PSYCHOL
55 SF
TLT
101 SF
PTSD.
PSYCHOL
164 SF
MHICM
GROUP
285 SF
PTSD GROUP
281 SF
PTSD GROUP
92 SF
PTSD.
PSYCHOL
99 SF
WKR
99 SF
PTSD. SOC.
WKR.
53 SF
TLT
202C
53 SF
TLT.
202B
221 SF
STAIR # 1
S2-1
132 SF
PTSD.
PSYCHOL
125 SF
PTSD.
PSYCH. RES.
254 114 SF
PTSD.
PSYCH. RES.
109 SF
PTSD.
PSYCH. RES.
115 SF
PTSD.
PSYCH. RES.
177 SF
STAFF
BREAK
102 SF
OEF.
PSYCHOL.
106 SF
PTSD.
PSYCHO
113 SF
PTSD.
PSYCHOL.
173 SF
PTSD.
COORD/DIRECT
109 SF
PTSD.
PSYCHOL.
109 SF
PTSD.
PSYCHOL.
111 SF
PTSD.
PSYCHOL.
111 SF
PTSD.
PSYCH.
402 SF
PTSD.
GROUP 4
371 SF
PTSD. / OEF
GROUP
130 SF
HALL
C2-4
298 SF
HALL
C2-3
218 SF
HALL
C2-2
239 SF
HALL
C2-7
135 SF
HALL
C2-8
309 SF
HALL
C2-5
144T-400
4 TR-144-251
A B
144T-400
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-2025
REGIS
TE
R
ED
CO
MMUNICA T IONS DISTRIBUT IO
N
DESIGNER
RCDD
225 W WASHINGTON STREET
SUITE 2700
CHICAGO, IL 60606
P: 312.294.0501 F: 312.294.0003 www.imegcorp.com
PROJECT #22010109.00
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/2
/2
:0
:4
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /5
-7
.B
.T R
.r v t
144T-102
LEVEL 02 PLAN - TECHNOLOGY
EW IMEG
100% CONSTRUCTION
DOCUMENTS
05/09/2025
509-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
N O R
HT
1/8" = 1'-0"
LEVEL 02 PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO SITEPLAN TS001 FOR ADDITIONAL
INFORMATION.
2. REFER TO T500 AND T501 FOR CAMPUS OPTICAL FIBER
CABLE RISER DIAGRAMS.
3. REFER TO 2/T400 FOR HANDHOLE DETAIL.
4. NEW BACKBONE OPTICAL FIBER CABLES SHALL BE
INDOOR/OUTDOOR TYPE.
5. ALL BACKBONE OPTICAL FIBER CABLE PATHWAYS SHALL
BE NEW. DO NOT RE-USE EXISTING BACKBONE CABLE
PATHWAYS FOR NEW BACKBONE CABLES.
6. TRANSITION PVC CONDUITS TO GRC IN CRAWL SPACE OR
EXPOSED EXTERIOR LOCATIONS. TRANSITION TO EMT
CONDUITS AT INTERIOR OF BUILDING.
KEY NOTES:
1. ROUTE CONDUIT UP THRU FLOOR FROM TR #149 AT
FLOOR BELOW. CONTINUE ROUTE OF CONDUIT UP TO
ABOVE CABLE TRAY.
Revisions: Date: 611 of 713
FIBER
DISTRIBUTION
CABINET
FIBER
DISTRIBUTION
CABINET
C
TELECOM
BA
TELECOM
A B
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES
OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF
CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE
TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE
SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
2. REFER TO ELECTRICAL DRAWINGS FOR CHANNEL RACK AND FIBER OPTIC
DISTRIBUTION CABINET SPECIFICATIONS
TELECOMMUNICATIONS ROOM TR-144-149
24 STRANDS OS2 FIBER OPTIC
CABLE, SIDE "A" , TO BUILDING 135
24 STRANDS OS2 FIBER OPTIC
CABLE, SIDE "B" , TO BUILDING 135
TELECOMMUNICATIONS ROOM TR-144-251
24 STRANDS OS2 FIBER OPTIC
CABLE, SIDE "A" , TO BUILDING 135
24 STRANDS OS2 FIBER OPTIC
CABLE, SIDE "B" , TO BUILDING 135
CHANNEL RACK
CHANNEL RACK
LEVEL 01
LEVEL 02
TELECOM
A B
KEYNOTES:
1. THROUGH FLOOR/CEILING PENETRATION FOR BACKBONE CONDUIT. CONTINUE CONDUTI UP
TO ABOVE CABLE TRAY. OPTICAL FIBER CABLES CONTINUE ON CABLE TRAY TO RACKS.
C
TELECOM
BA
KEYNOTES:
1. THROUGH WALL PENETRATION FOR BACKBONE CONDUIT. OPTICAL FIBER CABLES CONTINUE
ON CABLE TRAY TO RACKS.
1 1
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-2025
REGIS
TE
R
ED
CO
MMUNICA T IONS DISTRIBUT IO
N
DESIGNER
RCDD
225 W WASHINGTON STREET
SUITE 2700
CHICAGO, IL 60606
P: 312.294.0501 F: 312.294.0003 www.imegcorp.com
PROJECT #22010109.00
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/2
/2
:0
:4
A
M
B
IM
/5
-2
-7
V A
H a m p to n E
H R
M /5
-7
.B
.T R
.r v t
144T-400
TECHNOLOGY ENLARGED PLANS
EW IMEG
100% CONSTRUCTION
DOCUMENTS
05/09/2025
509-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
N O R
HT
1/2" = 1'-0"
TELECOM ROOM ENLARGEMENT PLAN - TR-144-149
N O R
HT
1/2" = 1'-0"
TELECOM ROOM ENLARGEMENT PLAN - TR-144-251
NO SCALE
FIBER RISER DIAGRAM
NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR ROOM LAYOUT AND RACK ELEVATIONS.
2. ROUTE OPTICAL FIBER CABLES TO OVERHEAD CABLE TRAYS AND TERMINATE IN FIBER
DISTRIBUTION CABINET.
NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR ROOM LAYOUT AND RACK ELEVATIONS.
2. ROUTE OPTICAL FIBER CABLES TO OVERHEAD CABLE TRAYS AND TERMINATE IN FIBER
DISTRIBUTION CABINET
N O R
HT
1/2" = 1'-0"
TELECOM ROOM PATHWAYS - TR-144-251
N O R
HT
1/2" = 1'-0"
TELECOM ROOM PATHWAYS - TR-144-149
Revisions: Date:
N O R
HT
1/2" = 1'-0"
LEVEL 02
27B
27 31
27A
110A
110B
110D
13W
148-D
148-S
148-A
148T
138A 138136
137A
137C
137D
137B
137C
148B
173A
148-C
170 150
110C
143 167
G R
A V
E L
R O
A D
FRANKLIN BOULEVARD
FRANKLIN BOULEVARD
AVERILL AVENUE
AVERILL AVENUE
A M
E S
S T
R E
E T
HARRIS AVENUE
JONES CREEK
K N
O X S
T R
E E
T
T H
O M
P S
O N
S T
R E
E T
F R A N
K
LI
N B
O U
LE
V A R
D
MALLORY STREET
M A
R T
IN
L. K
IN
G
JR
. B O
U L E
V A R
D
M A R
TIN
L. K
IN
G
JR
. B O U
LE
V
AR
D
E M
A N
C
IP
A T
IO
N D
R
SHORE ROAD
H A R R
IS
A V E N
U E
HARRIS AVENUE
M c C
L E
L L A
N
S E
W E
LL
A
V E
N U
E
A V
E N
U E
TR
ICRA PHASING LINE
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
FEC
FE
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
XFEC EXISTING FIRE EXTINGUISHER
CABINET
2 HR FIRE BARRIER
1 HR SMOKE BARRIER
A B C
D
D
E
E
F
F
G
G
H
H
L
L
M
M
N
N
O
O
P
P
Q
Q
R
R
S
S
T
T
U
U
V
V
W
W
X
X
Y
Y
Z
Z
2 2
3 3
4 4
5 5
6 6
6.5
18.5
19.5
31 SF
ELECT
CLOSET
E1
127 SF
SOCIAL
WORKER
127 SF
TR
47 SF
MECH
ROOM
263 SF
CONFERENCE ROOM
159 SF
ACNS EXT
CARE NURSING
125 SF
NURSE
PRACTITIONER
7130 SF
NURSE
PRACTITIONER
114 SF
MEN'S
TOILET
130 SF
WOMEN'S
TOILET
484 SF
PATIENT ROOM (4)
484 SF
LIBRARY
48 SF
TOILET
100 SF
BATH
70 SF
BATH
47 SF
TOILET
254 SF
PATIENT ROOM (2)
466 SF
PATIENT ROOM (4)
185 SF
QUIET ROOM
122 SF
CLEAN LINEN
S F
O S
T O
R A
G E
109 SF
TOILET
295 SF
CONGREGATE BATH
60 SF
BATH
24 250 SF
PATIENT
ROOM
(2)
249 SF
PATIENT
ROOM
(2)
38 SF
TOILET
38 SF
STORAGE
512 SF
DAY / DINING ROOM
43 SF
TOILET
42 SF
TOILET
249 SF
PATIENT
ROOM
(2)
155 SF
PATIENT
ROOM
(1)
53 SF
TOILET
36 SF
SHOWER
ROOM
155 SF
PATIENT
ROOM
(1)
155 SF
PATIENT
ROOM
(1)
35 SF
SHOWER
ROOM
53 SF
TOILET
154 SF
PATIENT
ROOM
(1)
249 SF
PATIENT
ROOM
(2)
41 SF
TOILET
43 SF
TOILET
374 SF
NURSE STATION
S F
N O
U R
IS
H
M E
N T
R O
O M
92 SF
MEDICATION
ROOM
43 SF
TOILET
249 SF
PATIENT
ROOM
(2)
250 SF
PATIENT
ROOM
(2)
39 SF
TOILET
375 SF
STAFF LOUNGE
122 SF
CLEAN SUPPLY
111 SF
SOILED UTILITY
86 SF
NUTRITION ROOM
55A
85 SF
BATH
58 SF
HAC
336 SF
NURSE STATION
32 SF
TOILET
6 SF
CLOSET
89 SF
MEDICATION
ROOM
6139 SF
TOILET
250 SF
PATIENT
ROOM
(2)
252 SF
PATIENT ROOM (2)
43 SF
TOILET
249 SF
PATIENT ROOM (2)
249 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
253 SF
PATIENT
ROOM
(2)
252 SF
PATIENT ROOM (2)
43 SF
TOILET
43 SF
TOILET
245 SF
PATIENT ROOM (2)
244 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
256 SF
PATIENT
ROOM
(2)
254 SF
PATIENT ROOM (2)
43 SF
TOILET
179 SF
OFFICE
5A
124 SF
ENTRANCE
C1A
9 SF
DATA
CLOSET
T1
63 SF
BATH
23A
36 SF
TOILET
34A
39 SF
TOILET
41A
8 SF
ELEC CLOSET
E3
8 SF
DATA CLOSET
T2
147 SF
PATIENT
ROOM
(1)
48 SF
STAFF TOILET
48 SF
TOILET
148 SF
SOCIAL WORK
171 SF
SUPPLY ROOM
153 SF
AREA MAINT
433 SF
MECHANICAL ROOM
244 SF
MECHANICAL ROOM
2409 SF
MECHANICAL ROOM
154 SF
STORAGE
145 SF
PATIENT LAUNDRY
35 SF
HAC
125 SF
STAFF OFFICE
387 SF
SPD STORAGE
49 SF
O/T STORAGE
40 SF
HAC
641 SF
OT CLINIC
56 SF
UNISEX TOILET
58 SF
UNISEX TOILET
120 SF
OT OFFICE
120 SF
K / T OFFICE
51 SF
K / T STORAGE
640 SF
KT CLINIC
2208 SF
ECRC DINING
117 SF
ECRC KITCHEN
1373 SF
ECRC DAYROOM
128 SF
VENDING
77 SF
HYDRO
244 SF
LUGGAGE
203 SF
FILE STORAGE
713 SF
BEAUTY SALON / BARBER SHOP
151 SF
PATIENT
ROOM
(1)
48 SF
TOILET
48 SF
TOILET
155 SF
PATIENT
ROOM
(1)
44 SF
TOILET
254 SF
PATIENT
ROOM
(2)
255 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
245 SF
PATIENT
ROOM
(2)
243 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
510 SF
PATIENT
ROOM
(4)
253 SF
PATIENT ROOM (2)
43 SF
TOILET
43 SF
TOILET
250 SF
PATIENT ROOM (2)
43 SF
TOILET
251 SF
PATIENT
ROOM
(2)
249 SF
PATIENT ROOM (2)
84 SF
BATH
59 SF
HAC
360 SF
NURSE
STATION
97 SF
MED
ROOM
39 SF
TOILET
33 SF
TOILET
110 SF
SOILED
UTILITY
122 SF
CLEAN
LINEN
374 SF
NURSE TRAINING
39 SF
TOILET
249 SF
PATIENT
ROOM
(2)
251 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
246 SF
PATIENT
ROOM
(2)
251 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
249 SF
PATIENT
ROOM
(2)
156 SF
PATIENT
ROOM
(1)
50 SF
TOILET
67 SF
BATH
154 SF
PATIENT
ROOM
(1)
155 SF
PATIENT
ROOM
(1)
50 SF
TOILET
69 SF
BATH
156 SF
PATIENT
ROOM
(1)
250 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
253 SF
PATIENT
ROOM
(2)
246 SF
PATIENT
ROOM
(2)
43 SF
TOILET
43 SF
TOILET
250 SF
PATIENT
ROOM
(2)
250 SF
PATIENT
ROOM
(2)
64 SF
BATH
288 SF
CONGREGATE BATH
175109 SF
TOILET
96 SF
NUR. MGR
177A
121 SF
CLEAN LINEN
60 SF
OXYGEN
STORAGE
182 SF
QUIET ROOM
250 SF
PATIENT ROOM (2)
181 477 SF
PATIENT
ROOM
(4)
48 SF
TOILET
69 SF
BATH
102 SF
BATH
48 SF
TOILET
489 SF
PATIENT ROOM (4)
482 SF
DEN
9 SF
ELECT
CLOSET
E8
9 SF
DATA
CLOSET
T5
88 SF
NUTRITION
177B
61 SF
BATH
175A
139 SF
CORRIDOR
C6A
45 SF
ELECT CLOSET
E5
47 SF
DATA CLOSET
T3
529 SF
COOKING CHILL STAGING
104A
1635 SF
CORRIDOR
C6
64 SF
STORAGE /
WORK AREA
111a
449 SF
CORRIDOR
C7
853 SF
CORRIDOR
C8
56 SF
DATA
CLOSET
T4
47 SF
ELECT
CLOSET
E6
1060 SF
CORRIDOR
C10
935 SF
CORRIDOR
C9
1106 SF
CORRIDOR
C1
1104 SF
CORRIDOR
C2
938 SF
CORRIDOR
C3
99 SF
NURSE MANAGER
55B
867 SF
CORRIDOR
C4
131 SF
CORRIDOR
C9A
1871 SF
CORRIDOR
C5
124 SF
CORRIDOR
C8A
143 SF
TR
90A
PHASE 1:
CONTRACTOR TO COMPLETE THE WORK OF THIS TR
AND ASSOCIATED DATA DROPS. COMPLETE ONE
SECTION AT A TIME AS DIRECTED TO COR.
PHASE 2:
CONTRACTOR TO COMPLETE THE WORK
OF THIS TR AND ASSOCIATED DATA
DROPS. COMPLETE ONE SECTION AT A
TIME AS DIRECTED TO COR.
SECTION 1B:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO
COMPLETE DATA WIRING IN THIS AREA.
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO
COMPLETE DATA WIRING IN THIS AREA.
SECTION 2A:
CONTRACTOR TO COORDINATE WITH
VA FOR ROOM CLOSURES AND
AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
SECTION 2B:
CONTRACTOR TO COORDINATE WITH VA
FOR ROOM CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN THIS AREA.
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
D
IA
M O
N D
L
IN
E
D
IA
M O
N D
L
IN
E
DIAMOND LINE
DIAMOND LINE
COVERED WALKWAY
CONNECTING BUILDINGS
146, 148T AND 148A
EXISTING FE. REPLACE WITH NEW SEMI-
RECESSED FEC. REPLACE EXISTING FE
WITH NEW CLEAN AGENT EXTINGUISHER
THAT MEETS OR EXCEEDS THE ABC
RATING AND SIZE OF EXISTING
EXTINGUISHER. SEE DETAIL 3/A-603
EXISTING FE. REPLACE WITH NEW SEMI-RECESSED FEC.
REPLACE EXISTING FE WITH NEW CLEAN AGENT
EXTINGUISHER THAT MEETS OR EXCEEDS THE ABC RATING
AND SIZE OF EXISTING EXTINGUISHER. SEE DETAIL 3/A-603 BUILDING 146
KEY AREA SHOWN
TRUE
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/0 /2
:5
:2 a m
B
IM
/5
-2
-7
V A
H a m p to n
E H
R M
/B L D
G
.r v t
146AS101
BUILDING 146 - LEVEL 01 - PHASING PLAN
MA CO
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
LEGEND
KEY PLAN
1/16" = 1'-0"
BUILDING 146 - LEVEL 01 - PHASING PLAN
PROJECT
NORTH
0' 8' 16' 32'
Revisions: Date: 613 of 713
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
EXISTING LIGHTS TO DEMOLISH
NEW DOOR
NEW LIGHTS (SEE ELECTRICAL DETAILS)
PENDENT SPRINKLER
UPRIGHT SPRINKLER WITH GUARD
KEY AREA SHOWN
PROJECT
NORTH
1. ALL PRODUCTS AND WALL FINISHES SHALL MATCH EXISTING
OR ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILING WHERE
MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ARE
DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP UNPAINTED
AND VISIBLE ON THE NEW INSTALLED FRT PLYWOOD. SEE
DETAIL 5/AE421.
5. PATCH AND REPAIR GWB WHERE DOORS ARE DEMOLISHED
AND NEW DOORS ARE INSTALLED.
6. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
7. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
DEMOLISH EXISTING DOOR/FRAME. PREPARE FOR NEW
DOOR/FRAME.
DEMOLISH EXISTING FLOOR FINISH TO EXPOSE FLOOR
STRUCTURE UNDERNEATH. REMOVE EXISTING
SUBSTANCE/BONDING AGENT IF ANY. PREPARE FLOORING
FOR NEW WORK.
DEMOLISH EXISTING BASE REMOVE EXISTING ADHESIVE AND
PREPARE FOR NEW BASE.
DEMOLISH EXISTING ACT COMPLETELY INCLUDING ALL
GRIDS, SUPPORTING WIRES, CLIPS, AND PERIMETER WALL
ANGLES TO EXPOSE UNDERSIDE OF STRUCTURE ABOVE.
PATCH WALLS WHERE CEILING IS REMOVED.
INSTALL NEW DOOR/FRAME.
APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
INSTALL NEW RESILIENT RUBBER BASE AT ROOM
PERIMETER WITH SEALANT AT THE BOTTOM.
INSTALL FRT PLYWOOD OVER WALLS PER DETAIL 3/AE421,
TYPICAL.
INSTALL SPANDREL GLASS AND METAL AT INTERIOR OF
EXISTING WINDOW. REFERENCE DETAIL 1/A603.
ICRA KEYNOTES
INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER
TO SEPARATE CONSTRUCTION AREA FROM OCCUPIED
SPACE.
INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"X36", TYPICAL.
V W
DUCT TO
EXTERIOR
ANTE ROOM
127 SF
SOCIAL WORKER
127 SF
OFFICE
179 SF
OFFICE
5A
1106 SF
CORRIDOR
C1
V W
127 SF
SOCIAL
WORKER
127 SF
TR
179 SF
OFFICE
5A
1106 SF
CORRIDOR
C1
N E
W
F L O
O R
IN
G
EXISTING
FLOORING
10'x10' TR
FORM FACTOR
FOR EXCEPTION
± 8' - 3 3/4" (EXIST.)
/4
(E X
IS
T
/4
REUSE EXISTING
NOTE: EXISTING FE TO BE UPGRADED.
SEE SHEET 146AS101 FOR FE LOCATION.
V W
127 SF
SOCIAL WORKER
127 SF
OFFICE
179 SF
OFFICE
5A
1106 SF
CORRIDOR
C1
RM 3
V W
127 SF
SOCIAL
WORKER
127 SF
TR
179 SF
OFFICE
5A
1106 SF
CORRIDOR
C1
EXPOSED
2' - 2"
2' - 2"
POSITIVE ( + ) PRESSURE
CONSTRUCTION ZONE (--) PRESSURE
ANTE ROOM ( - ) PRESSURE
EXISTING WALL ACTING AS ICRA
BOUNDARY. SEAL ANY OPENINGS AND
PENETRATIONS AS REQUIRED.
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
/0 /2
:5
:1 a m
B
IM
/5
-2
-7
V A
H a m p to n
E H
R M
/B L D
G
.r v t
146A-101a
BUILDING 146 - LEVEL 01 - DEMO FLOOR PLAN,
DEMO RCP, FLOOR PLAN & RCP
MA CO
100% CONSTRUCTION
DOCUMENTS
07/18/2025
590-22-700EHRM INFRASTRUCTURE
UPGRADES - HAMPTON
HAMPTON VA MEDICAL CENTER, HAMPTON, VIRGINIA
GENERAL NOTES
KEY NOTES (THIS SHEET ONLY)
KEY PLAN
1/4" = 1'-0"
RM 3 - DEMO FLOOR PLAN
1/4" = 1'-0"
RM 3 - FLOOR PLAN
1/4" = 1'-0"
RM 3 - DEMO RCP
1/4" = 1'-0"
RM 3 - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
LEGEND
ICRA LEGEND - CLASS IV
Revisions: Date: 614 of 713
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
EXISTING LIGHTS TO DEMOLISH
NEW DOOR
NEW LIGHTS (SEE ELECTRICAL DETAILS)
PENDENT SPRINKLER
UPRIGHT SPRINKLER WITH GUARD
KEY AREA SHOWN
PROJECT
NORTH
1. ALL PRODUCTS AND WALL FINISHES SHALL MATCH EXISTING
OR ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILING WHERE
MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ARE
DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP UNPAINTED
AND VISIBLE ON THE NEW INSTALLED FRT PLYWOOD. SEE
DETAIL 5/AE421.
5. PATCH AND REPAIR GWB WHERE DOORS ARE DEMOLISHED
AND NEW DOORS ARE INSTALLED.
6. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
7. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
D E
10' - 0"
INTERIOR LINE OF
NEW WALL
DUCT TO
EXTERIOR
13 ANTE
ROOM
REMOVE ONE SIDE OF DOOR PANEL DURING
CONSTRUCTION FOR THE INSTALLATION OF ICRA
BARRIER. REINSTALL, PATCH AND REPAIR AFTER
REMOVAL OF CONSTRUCTION BARRIERS.
303 SF
STORAGE
139 SF
CORRIDOR
C6A
1635 SF
CORRIDOR
C6
D E
143 SF
TR
90A
154 SF
STORAGE
139 SF
CORRIDOR
C6A
90A
01a
NEW
FLOORING
EXISTING
FLOORING
10'x10' TR
FORM FACTOR
IN-04.02-24
10' - 0" (CLR.)
(E X
IS
T
REUSE EXISTING
NOTE: EXISTING FE TO BE UPGRADED.
SEE SHEET 146AS101 FOR FE LOCATION.
D
303 SF
STORAGE
139 SF
CORRIDOR
C6A
D
154 SF
STORAGE
139 SF
CORRIDOR
C6A
143 SF
TR
90A
EXPOSED
1' - 7"
1' - 7" 2' - 1"
2' - 1"
RM 90A
DE…
This is the start of the file's text. The full file is on GovTribe.