805CM3048CNCColumBidSet_Bk_09.pdf
PDF 15 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are construction design documents for the Calverton National Cemetery Columbarium Improvements project, specifically sheet 10 and 11 of the bid documents. The drawings show detailed elevations and existing conditions for Columbarium I, focusing on multiple wall sections (Walls 7C, S7, 8A, 8B, 8C, 8D, and 9A). The documents include restoration notes, existing conditions notes, and a legend indicating areas for repair and restoration of precast concrete wall structures. The images provide photographic and schematic views of the columbarium walls, highlighting specific areas that require cleaning, joint repairs, and potential concrete surface restoration. The project is located in Suffolk County, New York, and is part of a larger improvement initiative for the national cemetery's columbarium sections.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM I EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 10
CS130
25 of 99LTM BMD
COLUMBARIUM I - WALL 7C ELEVATION2 COLUMBARIUM I - WALL S7 ELEVATION3
COLUMBARIUM I - WALL 8A ELEVATION5 COLUMBARIUM I - WALL 8B ELEVATION6Scale: 1" = 5'
COLUMBARIUM I KEY1
WALL 7
W
ALL 8
W
ALL 6
CS130
WALL 8
WALL 9
CS130
COLUMBARIUM I - WALL S8 ELEVATION4
CS130
CS130
2 / D
5 / G
2 / D
2 / D
CS130
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM I
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES:
A
A
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
GRAVEL
STRIP
CS500
1 / B (ALL JOINTS
IN ELEVATION)
GRAVEL
STRIP
CS500
5 / G
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS500
CS501
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM I EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 11
CS131
26 of 99LTM BMD
COLUMBARIUM I - WALL 8C ELEVATION2 COLUMBARIUM I - WALL 8D ELEVATION3
COLUMBARIUM I - CONCRETE SPALLING IN FRONT OF WALLS 8C & D4 COLUMBARIUM I - WALL 9A ELEVATION5Scale: 1" = 5'
COLUMBARIUM I KEY1
WALL 7
W
ALL 8
W
ALL 6
CS131
CS131
WALL 8
WALL 9
CS131
CS131
2 / D
2 / D 2 / F,D
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM I
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES:
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
5 / G
5 / G
8 / H
1 / B (ALL JOINTS
IN ELEVATION)
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
PROTECT EXISTING
PAVEMENT TO REMAIN
A
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE AND RESET PRECAST CONCRETE CAP
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS500
1 & 3
CS501
CS501
| 25_CS130_COLUMBARIUM I RESTORATION-I-10 |
| Sheets and Views |
| I-10 |
| 26_CS131_COLUMBARIUM I RESTORATION-I-11 |
| Sheets and Views |
| I-11 |
File details come from the government source that posted it. Updated .