805CM3048CNCColumBidSet_Bk_29.pdf
PDF 12 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are bid documents for the Calverton National Cemetery Columbarium Improvements project, specifically focusing on existing conditions and restoration elevations for Columbarium M. The documents, prepared by the U.S. Department of Veterans Affairs Office of Construction and Facilities Management, detail comprehensive restoration and repair plans for multiple concrete walls and pavement areas. The drawings include detailed elevation views of Walls 12F through 16B, with annotations highlighting specific restoration requirements such as cleaning, sealant application, concrete cap repairs, and protection of existing pavement. Each wall section is meticulously documented with photographic evidence of current conditions, including crack assessments and structural integrity observations, providing a comprehensive visual and technical overview of the required improvements for the cemetery's columbarium infrastructure.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
ALL 9
WALL 9
WALL 8
W
ALL 11
W
ALL 10
WALL 12
WALL 13
W
ALL 18
W
ALL 1
WALL 11
WALL 10
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 9
CS209
80 of 99LTM BMD
COLUMBARIUM M - WALL 13C ELEVATION8 COLUMBARIUM M - WALL S13/14 ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - PAVEMENT CRACK10
COLUMBARIUM M - PAVEMENT CRACK5 COLUMBARIUM M - WALL 13A ELEVATION6 COLUMBARIUM M - WALL 13B ELEVATION7
COLUMBARIUM M - WALL 12F ELEVATION2 COLUMBARIUM M - WALL 12G ELEVATION3 COLUMBARIUM M - WALL S12/13 ELEVATION4
WALL 1
W
ALL 8
WALL 12
WALL 14
W
ALL 14
W
ALL 13
W
ALL 15
W
ALL 12
W
ALL 17
W
ALL 18
WALL 17
CS209
CS209
CS209
CS209
CS209
CS209
CS209
CS209
CS209
5 / G,B
5 / G,B
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
A,B
5 / G,B
A,B
A,B 8 / H
A,B
8 / H
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
PROTECT EXISTING
PAVEMENT TO REMAIN
H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS500
CS501
CS210
CS210
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 10
CS210
81 of 99LTM BMD
COLUMBARIUM M - WALL S16 ELEVATION8 COLUMBARIUM M - WALL 16A ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL 16B ELEVATION10
COLUMBARIUM M - WALL 15A ELEVATION5 COLUMBARIUM M - WALL 15B ELEVATION6 COLUMBARIUM M - WALL 15C ELEVATION7
COLUMBARIUM M - WALL 14A ELEVATION2 COLUMBARIUM M - WALL 14B ELEVATION3 COLUMBARIUM M - PAVEMENT CRACK4
WALL 11
WALL 10
WALL 12
WALL 13
WALL 12
WALL 14
W
ALL 14
W
ALL 13
W
ALL 15
W
ALL 12
W
ALL 17
W
ALL 18
W
ALL 16
W
ALL 17
W
ALL 18
WALL 16
WALL 17 WALL 18
CS210
CS210
CS210
CS210
CS210
CS210
CS210
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
8 / H
GRAVEL
STRIP
CS500
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
PROTECT EXISTING
PAVEMENT TO REMAIN
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS500
CS501
| 80_CS209_COLUMBARIUM M RESTORATION-M-9 |
| Sheets and Views |
| M-9 |
| 81_CS210_COLUMBARIUM M RESTORATION-M-10 |
| Sheets and Views |
| M-10 |
File details come from the government source that posted it. Updated .