805CM3048CNCColumBidSet_Bk_26.pdf
PDF 15 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are architectural design and restoration elevation drawings for Columbarium M at Calverton National Cemetery in Suffolk County, New York. The documents (Sheets CS203 and CS204) detail existing conditions and restoration requirements for multiple concrete wall panels within the columbarium, including specific elevations for Walls 3, 4, 5, 6, 7, and S-series walls. The drawings include restoration notes, existing conditions notes, and a legend indicating areas requiring cleaning, repair, and restoration. Each wall elevation is photographically documented, showing current conditions, with technical annotations for sealant placement, concrete cap details, and panel restoration specifications. The drawings are part of the U.S. Department of Veterans Affairs Office of Construction and Facilities Management bid documents, dated March 25, 2025, with project number 805CM3048, prepared by The LA Group from Saratoga Springs, NY.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 3
CS203
74 of 99LTM BMD
COLUMBARIUM M - WALL 4B ELEVATION9 COLUMBARIUM M - WALL 4C ELEVATION10
Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL 5A ELEVATION11
COLUMBARIUM M - WALL S3 ELEVATION5 COLUMBARIUM M - PAVEMENT CRACK6
COLUMBARIUM M - WALL 4A ELEVATION8
COLUMBARIUM M - WALL 3C ELEVATION2 COLUMBARIUM M - WALL 3D ELEVATION3 COLUMBARIUM M - WALL 3E ELEVATION4
CS203
WALL 1
W
ALL 8
W
ALL 1
W
ALL 3
W
ALL 5
WALL 2
WALL 4
WALL 3
W
ALL 7
W
ALL 6
W
ALL 6
W
ALL 7
WALL 7
WALL 6
5 / G,B
CS203
CS203
CS203
CS203
CS203
CS203
CS203
CS203
GRAVEL
STRIP
CS500
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E) 8 / H
PROTECT EXISTING
PAVEMENT TO REMAIN
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
A,B
CS203
COLUMBARIUM M - WALL S47
GRAVEL
STRIP
CS500
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS500
CS501
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 4
CS204
75 of 99LTM BMD
COLUMBARIUM M - WALL S6/7 ELEVATION8 COLUMBARIUM M - WALL 7A ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL 7B ELEVATION10
COLUMBARIUM M - WALL 6B ELEVATION5 COLUMBARIUM M - WALL 6C ELEVATION6 COLUMBARIUM M - WALL 6D ELEVATION7
COLUMBARIUM M - WALL 5B ELEVATION2 COLUMBARIUM M - WALL S7/6 ELEVATION3 COLUMBARIUM M - WALL 6A ELEVATION4
CS204
WALL 1
W
ALL 8
W
ALL 1
W
ALL 3
W
ALL 5
WALL 2
WALL 4
WALL 3
W
ALL 7
W
ALL 6
W
ALL 6
W
ALL 7
WALL 7
WALL 6
CS204
CS204
CS204
CS204
CS204
CS204
CS204
CS204
5 / G,B
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
SEE 6/CS204A,B
LEGEND:
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS501
| 74_CS203_COLUMBARIUM M RESTORATION-M-3 |
| Sheets and Views |
| M-3 |
| 75_CS204_COLUMBARIUM M RESTORATION-M-4 |
| Sheets and Views |
| M-4 |
File details come from the government source that posted it. Updated .