805CM3048CNCColumBidSet_Bk_27.pdf
PDF 14 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These engineering design drawings depict the existing conditions and restoration elevations for Columbarium M at Calverton National Cemetery in Suffolk County, New York. The document (Sheet CS205 and CS206) shows detailed architectural plans and photographic documentation of multiple concrete wall elevations, pavement cracks, and restoration requirements. Key visual elements include:
- Comprehensive site layout with multiple wall sections labeled (Walls 1-7)
- Photographic evidence of concrete wall panels, pavement conditions, and structural details
- Restoration notes indicating requirements for concrete panel repairs, sealant applications, and concrete cap treatments
- Specific elevation views of Columbarium M walls, showing numbered sections (A-D) and condition assessments
- Annotations for protecting existing pavement and cleaning wall surfaces
- Part of a larger project (Project Number 805CM3048) for improvements to Columbarium facilities at the national cemetery, dated March 25, 2025
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 5
CS205
76 of 99LTM BMD
COLUMBARIUM M - WALL 8A ELEVATION8 COLUMBARIUM M - WALL 8B ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL 8C ELEVATION10
COLUMBARIUM M - WALL 7E ELEVATION5 COLUMBARIUM M - PAVEMENT CRACK6 COLUMBARIUM M - WALL S9/8 ELEVATION7
COLUMBARIUM M - WALL 7C ELEVATION2 COLUMBARIUM M - WALL 7D ELEVATION3 COLUMBARIUM M - PAVEMENT CRACK4
CS205
WALL 1
W
ALL 8
W
ALL 1
WALL 2
W
ALL 7
W
ALL 6
W
ALL 6
W
ALL 7
WALL 7
WALL 6
CS205
CS205
W
ALL 9
WALL 9
WALL 8
W
ALL 11
W
ALL 10
WALL 12
WALL 13
W
ALL 18
W
ALL 1
WALL 11
WALL 10
CS205
CS205
CS205
CS205
CS205
CS205
5 / G,B
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
A,B
8 / H
8 / H
5 / G
A,B
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
PROTECT EXISTING
PAVEMENT TO REMAIN
PROTECT EXISTING
PAVEMENT TO REMAIN
H
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS500
CS501
CS206
W
ALL 9
WALL 9
WALL 8
W
ALL 11
W
ALL 10
WALL 12
WALL 13
W
ALL 18
W
ALL 1
WALL 11
WALL 10
CS206
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 6
CS206
77 of 99LTM BMD
COLUMBARIUM M - WALL 9C ELEVATION8 COLUMBARIUM M - WALL 9D ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL S11/10 ELEVATION10
COLUMBARIUM M - WALL S8/9 ELEVATION5 COLUMBARIUM M - WALL 9A ELEVATION6 COLUMBARIUM M - WALL 9B ELEVATION7
COLUMBARIUM M - PAVEMENT CRACK2 COLUMBARIUM M - WALL 8D ELEVATION3 COLUMBARIUM M - PAVEMENT CRACK4
WALL 1
W
ALL 8
W
ALL 1
WALL 2
W
ALL 7
W
ALL 6
W
ALL 6
W
ALL 7
WALL 7
WALL 6
CS206
CS206
CS206
CS206
CS206
CS206
CS206
5 / G,B
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
A,B
8 / H
8 / H
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
PROTECT EXISTING
PAVEMENT TO REMAIN PROTECT EXISTING
PAVEMENT TO REMAIN
H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS500
CS501
| 76_CS205_COLUMBARIUM M RESTORATION-M-5 |
| Sheets and Views |
| M-5 |
| 77_CS206_COLUMBARIUM M RESTORATION-M-6 |
| Sheets and Views |
| M-6 |
File details come from the government source that posted it. Updated .