These are technical architectural drawings for the Calverton National Cemetery Columbarium Improvements project, specifically Sheet 3 and Sheet 4 of the bid documents. The drawings provide detailed existing conditions and restoration elevations for Columbarium I, showing multiple wall sections (Walls 2A, 2B, 2C, 2D, 2E, 3A, 3B, 3C) with precise architectural details. The documents include restoration notes indicating requirements for cleaning, joint repairs, and surface treatments, along with existing conditions notes describing the current state of concrete and pavement. The drawings are part of project number 805CM3048, issued by the U.S. Department of Veterans Affairs Office of Construction and Facilities Management, located in Suffolk County, New York, with an issue date of March 25, 2025. The technical drawings include key elevation views, restoration annotations, and a columbarium key layout, representing a comprehensive architectural plan for improvements to the cemetery's columbarium structures.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM I EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 3
CS123
18 of 99LTM BMD
COLUMBARIUM I - WALL 2A ELEVATION2 COLUMBARIUM I - WALL 2B ELEVATION3
COLUMBARIUM I - WALL 2C ELEVATION4 COLUMBARIUM I - WALL 2D ELEVATION5Scale: 1" = 5'
COLUMBARIUM I KEY1
W
ALL 1
W
ALL 1
W
ALL 2
WALL 2
CS123
CS123
CS123
WALL 1
W
ALL 2
WALL 3
CS123
2 / D
2 / D 2 / D
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM I
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES: 2 / D
5 / G
1 / B (ALL JOINTS
IN ELEVATION)
SEE 2/CS123
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
A
LEGEND:
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS501
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM I EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 4
CS124
19 of 99LTM BMD
COLUMBARIUM I - WALL 2E ELEVATION2 COLUMBARIUM I - WALL 3A ELEVATION3
COLUMBARIUM I - WALL 3B ELEVATION4 COLUMBARIUM I - WALL 3C ELEVATION5Scale: 1" = 5'
COLUMBARIUM I KEY1
W
ALL 3
W
ALL 1
W
ALL 2
WALL 3
CS124
CS124
CS124
W
ALL 2
CS124
W
ALL 4
PERGOLA
5 / G
2 / D
5 / G
2 / D
2 / D 2 / D
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM I
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES:
A
5 / G
1 / B (ALL JOINTS
IN ELEVATION)
A
A
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
5 / G
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS500
CS501
| 18_CS123_COLUMBARIUM I RESTORATION-I-3 |
| Sheets and Views |
| I-3 |
| 19_CS124_COLUMBARIUM I RESTORATION-I-4 |
| Sheets and Views |
| I-4 |