805CM3048CNCColumBidSet_Bk_24.pdf
PDF 16 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are architectural engineering drawings for the Calverton National Cemetery Columbarium Improvements project, specifically Sheet 10 and Sheet 11 (Drawing Numbers CS190 and CS191). The documents detail existing conditions and restoration elevations for multiple columbarium walls (Walls 14-18), showing precise photographic and schematic representations of concrete wall panels requiring restoration work. The drawings include technical restoration notes indicating cleaning requirements, with specific annotations about concrete panels, sealants, concrete caps, and flatwork. The project is located in Suffolk County, New York, and is part of the U.S. Department of Veterans Affairs' Office of Construction and Facilities Management, with design work completed by The LA Group from Saratoga Springs, NY. The drawings are dated March 25, 2025, and are part of the bid document set for solicitation number 36C78625B0029, which involves comprehensive repairs and improvements to multiple columbarium sections at the Calverton National Cemetery.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM L EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 10
CS190
68 of 99LTM BMD
COLUMBARIUM L - WALL 16A ELEVATION8 COLUMBARIUM L - WALL 16B ELEVATION9Scale: 1" = 5'
COLUMBARIUM L KEY1 COLUMBARIUM L - WALL 16C ELEVATION10
COLUMBARIUM L - WALL 15B ELEVATION5 COLUMBARIUM L - WALL 15C ELEVATION6 COLUMBARIUM L - WALL S16 ELEVATION7
COLUMBARIUM L - WALL 14A ELEVATION2 COLUMBARIUM L - WALL 14B ELEVATION3 COLUMBARIUM L - WALL 15A ELEVATION4
CS190
W
ALL 12
W
ALL 13
W
ALL 13
W
ALL 12
WALL 12
WALL 13
W
ALL 14
WALL 15
WALL 16
W
ALL 18
WALL 17
WALL 18
CS190
CS190
CS190
CS190
CS190
CS190
CS190
CS190
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM L
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
LEGEND:
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS501
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM L EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 11
CS191
69 of 99LTM BMD
COLUMBARIUM L - WALL 18B ELEVATION8 COLUMBARIUM L - WALL 18C ELEVATION9Scale: 1" = 5'
COLUMBARIUM L KEY1 COLUMBARIUM L - WALL 18D ELEVATION10
COLUMBARIUM L - WALL 17C ELEVATION5 COLUMBARIUM L - WALL 17D ELEVATION6 COLUMBARIUM L - WALL 18A ELEVATION7
COLUMBARIUM L - WALL 16D ELEVATION2 COLUMBARIUM L - WALL 17A ELEVATION3 COLUMBARIUM L - WALL 17B ELEVATION4
WALL 11
WALL 10
W
ALL 11
W
ALL 10
W
ALL 12
W
ALL 13
W
ALL 13
W
ALL 12
WALL 12
WALL 13
W
ALL 14
WALL 15
WALL 16
W
ALL 16
W
ALL 18
W
ALL 18
WALL 17
WALL 18
CS191
CS191
CS191
CS191
CS191
CS191
CS191
CS191
CS191
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM L
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
LEGEND:
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS501
| 68_CS190_COLUMBARIUM L RESTORATION-L-10 |
| Sheets and Views |
| L-10 |
| 69_CS191_COLUMBARIUM L RESTORATION-L-11 |
| Sheets and Views |
| L-11 |
File details come from the government source that posted it. Updated .