805CM3048CNCColumBidSet_Bk_21.pdf
PDF 15 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are technical engineering drawings for the Calverton National Cemetery Columbarium Improvements project, specifically Columbarium L's existing conditions and restoration elevations. The documents, issued by the U.S. Department of Veterans Affairs Office of Construction and Facilities Management on March 25, 2025, detail comprehensive restoration and repair specifications for multiple columbarium walls (Walls 3-7). The drawings include existing condition photographs, elevation views, and a site key layout, with restoration notes indicating requirements such as cleaning, surface preparation, concrete panel repairs, and preservation of existing pavement. The project is located in Suffolk County, New York, and is part of a broader cemetery improvement initiative involving multiple columbarium sections (H through M).
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CS184
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM L EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 4
CS184
62 of 99LTM BMD
COLUMBARIUM L - PAVEMENT HEAVING8 COLUMBARIUM L - WALL S5/6 ELEVATION9Scale: 1" = 5'
COLUMBARIUM L KEY1 COLUMBARIUM L - WALL 6A ELEVATION10
COLUMBARIUM L - WALL 5A ELEVATION5 COLUMBARIUM L - WALL 5B ELEVATION6 COLUMBARIUM L - WALL 5C ELEVATION7
COLUMBARIUM L - WALL 4A ELEVATION2 COLUMBARIUM L - WALL 4B ELEVATION3 COLUMBARIUM L - WALL 4C ELEVATION4
W
ALL 1
WALL 1
W
ALL 1
W
ALL 2
WALL 2
WALL 3
W
ALL 2
W
ALL 3
W
ALL 7
W
ALL 4
W
ALL 6
W
ALL 5
WALL 5
WALL 7
WALL 8
WALL 9
WALL 6
WALL 7
CS184
CS184
CS184
CS184
CS184
CS184
CS184
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM L
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
PROTECT EXISTING
PAVEMENT TO REMAIN
8 / H
CS184
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS500
CS501
CS185
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM L EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 5
CS185
63 of 99LTM BMD
COLUMBARIUM L - WALL 7D ELEVATION8 COLUMBARIUM L - WALL 7E ELEVATION9Scale: 1" = 5'
COLUMBARIUM L KEY1 COLUMBARIUM L - WALL 7F ELEVATION10
COLUMBARIUM L - WALL 7A ELEVATION5 COLUMBARIUM L - WALL 7B ELEVATION6 COLUMBARIUM L - WALL 7C ELEVATION7
COLUMBARIUM L - WALL 6B ELEVATION2 COLUMBARIUM L - WALL 6C ELEVATION3 COLUMBARIUM L - WALL S6/7 ELEVATION4
W
ALL 1
WALL 1
W
ALL 1
W
ALL 2
WALL 2
WALL 3
W
ALL 2
W
ALL 3
W
ALL 7
W
ALL 4
W
ALL 6
W
ALL 5
WALL 5
WALL 7
WALL 8
WALL 9
WALL 6
WALL 7
CS185
CS185
CS185
CS185
CS185
CS185
CS185
CS185
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. NOT APPLICABLE IN COLUMBARIUM L
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
LEGEND:
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS501
| 62_CS184_COLUMBARIUM L RESTORATION-L-4 |
| Sheets and Views |
| L-4 |
| 63_CS185_COLUMBARIUM L RESTORATION-L-5 |
| Sheets and Views |
| L-5 |
File details come from the government source that posted it. Updated .