805CM3048CNCColumBidSet_Bk_28.pdf
PDF 14 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are construction bid documents for the Calverton National Cemetery Columbarium Improvements project, specifically detailing existing conditions and restoration elevations for Columbarium M. The drawings (sheets CS207 and CS208) show detailed elevation views and a key layout for multiple wall sections (Walls 1-12), including photographic documentation of current wall conditions. The documents indicate specific restoration requirements, such as cleaning of walls, protecting existing pavement, and addressing concrete panel and cap conditions. The project is located in Suffolk County, New York, with an issue date of March 25, 2025, and is part of a larger improvement project for Columbarium H, I, J, K, L, and M under VA National Cemetery Administration solicitation number 36C78625B0029.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
ALL 9
WALL 9
WALL 8
W
ALL 11
W
ALL 10
WALL 12
WALL 13
W
ALL 18
W
ALL 1
WALL 11
WALL 10
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 7
CS207
78 of 99LTM BMD
COLUMBARIUM M - WALL S10/11 ELEVATION8 COLUMBARIUM M - WALL 11A ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL 11B ELEVATION10
COLUMBARIUM M - WALL 10D ELEVATION5 COLUMBARIUM M - WALL 10E ELEVATION6 COLUMBARIUM M - WALL 10F ELEVATION7
COLUMBARIUM M - WALL 10A ELEVATION2 COLUMBARIUM M - WALL 10B ELEVATION3 COLUMBARIUM M - WALL 10C ELEVATION4
WALL 1
W
ALL 88
CS207
CS207
WALL 12
WALL 14
W
ALL 14
W
ALL 13
W
ALL 15
W
ALL 12
W
ALL 17
W
ALL 18
WALL 17
CS207
CS207
CS207
CS207
CS207
CS207
CS207
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
A,B
5 / G,B
A,B
3 / C
5 / G,B
A,B
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE AND REPLACE PRECAST CONCRETE CAP
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
CS500
1 & 3
CS501
CS501
W
ALL 9
WALL 9
WALL 8
W
ALL 11
W
ALL 10
WALL 12
WALL 13
W
ALL 18
W
ALL 1
WALL 11
WALL 10
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM M EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 8
CS208
79 of 99LTM BMD
COLUMBARIUM M - WALL 12C ELEVATION8 COLUMBARIUM M - WALL 12D ELEVATION9Scale: 1" = 5'
COLUMBARIUM M KEY1 COLUMBARIUM M - WALL 12E ELEVATION10
COLUMBARIUM M - WALL S15/12 ELEVATION5 COLUMBARIUM M - WALL 12A ELEVATION6 COLUMBARIUM M - WALL 12B ELEVATION7
COLUMBARIUM M - WALL 11C ELEVATION2 COLUMBARIUM M - WALL 11D ELEVATION3 COLUMBARIUM M - WALL 11E ELEVATION4
WALL 1
W
ALL 8
CS208
WALL 12
WALL 14
W
ALL 14
W
ALL 13
W
ALL 15
W
ALL 12
W
ALL 17
W
ALL 18
WALL 17
CS208
CS208
CS208
CS208
CS208
CS208
CS208
CS208
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 5/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. NOT APPLICABLE IN COLUMBARIUM M
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. NOT APPLICABLE IN COLUMBARIUM M
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 5/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. REPAIR STONE VENEER
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. FAILING STONE VENEER AND / OR STONE CAP
8. PITTED AND SPALLING CONCRETE FLATWORK
9. WALL FOUNDATION EXPOSED ALONG BERM
EXISTING CONDITIONS NOTES:
3 / C 3 / C
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
LEGEND:
REMOVE AND REPLACE PRECAST CONCRETE CAP
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONES PER SPECIFICATIONS.
1 & 3
CS501
CS501
| 78_CS207_COLUMBARIUM M RESTORATION-M-7 |
| Sheets and Views |
| M-7 |
| 79_CS208_COLUMBARIUM M RESTORATION-M-8 |
| Sheets and Views |
| M-8 |
| 80_CS209_COLUMBARIUM M RESTORATION-M-9 |
| Sheets and Views |
| M-9 |
File details come from the government source that posted it. Updated .