About this file

These are architectural bid documents for the Calverton National Cemetery Columbarium Improvements project, specifically focusing on Columbarium H. The documents detail existing conditions and restoration elevations for multiple wall sections, including wall numbering, niche column configurations, and restoration requirements. Key restoration activities include removing and replacing cracked precast concrete panels, reinstalling loose wall caps, replacing joint sealants, removing existing vegetation, adding gravel strips, and replacing mulch with decorative stones.

The project involves comprehensive improvements to the columbarium structures, with specific notes on protecting existing pavement, maintaining utilities and structures, and implementing traffic control measures. The drawings provide a detailed overview of wall sections (Walls 1-10), include a plant list for landscaping (such as Arborvitae and Dwarf Hinoki Cypress), and specify construction techniques like removing and resetting precast concrete caps and installing perimeter safety railings. The bid documents are part of a larger federal contract opportunity (Solicitation Number 36C78625B0029) for the Department of Veterans Affairs National Cemetery Administration, located in Suffolk County, New York.

View the file

Other files

File Type Posted
Virtual BID Opening New Date - 29 July 2025 - Calverton Natl Cem - FY-25.pdf PDF
A0004 - Calverton National Cemetery - 36C78625B0029 - FY-25.pdf PDF
805CM3048CNCColumBidSet_Bk_27.pdf PDF
A0003- Questions and Answers to RFIs - Calverton NC - 805CM3048 - FY-25.pdf PDF
Amandment A0003 - Claverton Natl Cem - 36C78625B0029 - FY-25.pdf PDF
805CM3048CNCColumBidSet_Bk_11.pdf PDF
Wage Determination - DB - Nassau - Suffolk Counties - Calverton Natl Cem.pdf PDF
SCHEDULE - Calverton Natl Cem - FY-25.pdf PDF
805CM3048CNCColumBidSet_Bk_33.pdf PDF
805CM3048CNCColumBidSet_Bk_14.pdf PDF
805CM3048CNCColumBidSet_Bk_19.pdf PDF
805CM3048CNCColumBidSet_Bk_12.pdf PDF
805CM3048CNCColumBidSet_Bk_13.pdf PDF
805CM3048CNCColumBidSet_Bk_35.pdf PDF
805CM3048CNCColumBidSet_Bk_30.pdf PDF
805CM3048CNCColumBidSet_Bk_29.pdf PDF
805CM3048CNCColumBidSet_Bk_32.pdf PDF
805CM3048CNCColumBidSet_Bk_21.pdf PDF
805CM3048CNCColumBidSet_Bk_28.pdf PDF
805CM3048CNCColumBidSet_Bk_23.pdf PDF
805CM3048CNCColumBidSet_Bk_18.pdf PDF
805CM3048CNCColumBidSet_Bk_16.pdf PDF
805CM3048CNCColumBidSet_Bk_31.pdf PDF
805CM3048CNCColumBidSet_Bk_34.pdf PDF
A0001 - Calverton National Cemetery - IFB No 36C78625B0029 - FY-25.pdf PDF
805CM3048CNCColumBidSet_Bk_24.pdf PDF
Attachment No 09 - DOL Payroll Form - FY-25.pdf PDF
Attachment No 01 - VIRTUAL BID OPENING -CALVERTON NATL CEM - IFB NO 36C78625B0029 - PROJECT NO 805CM3048.pdf PDF
805CM3048CNCColumBidSet_Bk_08.pdf PDF
805CM3048CNCColumBidSet_Bk_05.pdf PDF
805CM3048CNCColumBidSet_Bk_01.pdf PDF
805CM3048 Calverton NC Construction SOW.pdf PDF
36C78625B0029.docx DOCX document
Attachment No 08 - UEI for BID.pdf PDF
805CM3038 Calverton NC Col L-M Bk02.pdf PDF
805CM3048CNCColumBidSet_Bk_09.pdf PDF
805CM3048CNCColumBidSet_Bk_06.pdf PDF
805CM3048CNCColumBidSet_Bk_02.pdf PDF
Attachment No 10 - Davis-Bacon Act Poster.pdf PDF
Attachment No 07 - NCA Contractor Safety Checklist - FY-25.pdf PDF
Attachment No 05 - RFI Form - Calverton Natl Cem - PO No 805CM3048 - FY-25_01.pdf PDF
Attachment No 04 - Standard Form 1413 - FY-25.pdf PDF
Attachment 03 - LIMITATIONS ON SUBCONTRACTING_CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION - JAN 2023 - DEVIATION.pdf PDF
Attachment 02 - Cost Estimate Worksheet - Calverton Natl Cemtery - PO No 805CM3048 - FY-25_01.xlsx XLSX spreadsheet
805CM3048CNCColumBidSet_Bk_10.pdf PDF
805CM3048CNCColumBidSet_Bk_07.pdf PDF
805CM3048CNCColumBidSet_Bk_03.pdf PDF
805CM3038 Calverton NC Col L-M Bk01.pdf PDF
805CM3048 CNC Columb Specs.pdf PDF
Revised Specs - 805CM3048_CNC Columbarium Revised Specs Merge.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

SUFFOLK COUNTY, NEW YORK

805CM3048

MARCH 25, 2025

U.S. Department of Veterans Affairs

STAMP

Revisions: Date:

Drawing Title

Approved:

Phase

Building Number

VA FORM 08 - 6231

321 4 5 6 7 8 9 10

CALVERTON NATIONAL CEMETERY

COLUMBARIUM IMPROVEMENTS

ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management

BID DOCUMENTS

INTEGRITY FEDERAL SERVICES /

THE LA GROUP JOINT VENTURE

Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg

WV 25401

(304)-725-8456

The LA Group 40 Long Alley Saratoga Springs

NY 12866

(518)-587-8100

COLUMBARIUM H EXISTING CONDITIONS

/ RESTORATION ELEVATIONS - SHEET 10

CS111

12 of 99LTM BMD

COLUMBARIUM H - WALL 8B ELEVATION2 COLUMBARIUM H - WALL 8C ELEVATION3

COLUMBARIUM H - WALL 8D ELEVATION4 COLUMBARIUM H - WALL 8E ELEVATION5Scale: 1" = 5'

COLUMBARIUM H KEY1

CS111

CS111

CS111

CS111

2 / D

5 / G

2 / D

2 / D

2 / D

WALL 6

W

ALL 7

W

ALL 8

WALL 6

WALL 8

WALL 8

W

ALL 8

W

ALL 9

WALL 9

W

ALL 9

A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND

SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL

PANELS TO BE CLEANED. SEE SPECIFICATIONS.

B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN

PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE

SPECIFICATIONS.

C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE

DETAIL 1/CS501

D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.

SEE SPECIFICATIONS.

E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER

WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT

PER SPECIFICATIONS.

F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501

G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE

DETAIL 10/CS500

H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500

I. NOT APPLICABLE IN COLUMBARIUM H

RESTORATION NOTES:

1. FAILING PANEL JOINT SEALANT, TYP.

2. FAILING COPING JOINT SEALANT, TYP.

3. CRACKED PRECAST CONCRETE CAP, TYP.

4. STAINED PRECAST CONCRETE PANELS, TYP.

5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.

6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.

7. NOT APPLICABLE IN COLUMBARIUM H

8. PITTED AND SPALLING CONCRETE FLATWORK

EXISTING CONDITIONS NOTES:

1 / B (ALL JOINTS

IN ELEVATION)

5 / G

1 / B (ALL JOINTS

IN ELEVATION)

1 / B (ALL JOINTS

IN ELEVATION)

1 / B (ALL JOINTS

IN ELEVATION)

NOTE: ALL WALLS ON THIS SHEET TO

RECEIVE CLEANING (E)

LEGEND:

REMOVE EX. VEGETATION & MULCH. NEW GRAVEL

& DECORATIVE STONE PER SPECIFICATIONS

CS501

Project Title

Location

Issue Date Checked Drawn

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

SUFFOLK COUNTY, NEW YORK

805CM3048

MARCH 25, 2025

U.S. Department of Veterans Affairs

STAMP

Revisions: Date:

Drawing Title

Approved:

Phase

Building Number

VA FORM 08 - 6231

321 4 5 6 7 8 9 10

CALVERTON NATIONAL CEMETERY

COLUMBARIUM IMPROVEMENTS

ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management

BID DOCUMENTS

INTEGRITY FEDERAL SERVICES /

THE LA GROUP JOINT VENTURE

Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg

WV 25401

(304)-725-8456

The LA Group 40 Long Alley Saratoga Springs

NY 12866

(518)-587-8100

COLUMBARIUM H EXISTING CONDITIONS

/ RESTORATION ELEVATIONS - SHEET 11

CS112

13 of 99LTM BMD

COLUMBARIUM H - WALL S8/9 ELEVATION2 COLUMBARIUM H - WALL 9A ELEVATION3

COLUMBARIUM H - WALL 9B ELEVATION4 COLUMBARIUM H - WALL 9C ELEVATION5Scale: 1" = 5'

COLUMBARIUM H KEY1

CS112

CS112

CS112

CS112

2 / D

2 / D

5 / G

2 / D

W

ALL 8

WALL 8

W

ALL 8

W

ALL 9

WALL 9

W

ALL 9

5 / G

A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND

SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL

PANELS TO BE CLEANED. SEE SPECIFICATIONS.

B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN

PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE

SPECIFICATIONS.

C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE

DETAIL 1/CS501

D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.

SEE SPECIFICATIONS.

E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER

WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT

PER SPECIFICATIONS.

F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501

G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE

DETAIL 10/CS500

H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500

I. NOT APPLICABLE IN COLUMBARIUM H

RESTORATION NOTES:

1. FAILING PANEL JOINT SEALANT, TYP.

2. FAILING COPING JOINT SEALANT, TYP.

3. CRACKED PRECAST CONCRETE CAP, TYP.

4. STAINED PRECAST CONCRETE PANELS, TYP.

5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.

6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.

7. NOT APPLICABLE IN COLUMBARIUM H

8. PITTED AND SPALLING CONCRETE FLATWORK

EXISTING CONDITIONS NOTES:

1 / B (ALL JOINTS

IN ELEVATION)

1 / B (ALL JOINTS

IN ELEVATION)

1 / B (ALL JOINTS

IN ELEVATION)

SEE 4/CS112

NOTE: ALL WALLS ON THIS SHEET TO

RECEIVE CLEANING (E)

A

LEGEND:

REMOVE EX. VEGETATION & MULCH. NEW GRAVEL

& DECORATIVE STONE PER SPECIFICATIONS

CS501

Project Title

Location

Issue Date Checked Drawn

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

SUFFOLK COUNTY, NEW YORK

805CM3048

MARCH 25, 2025

U.S. Department of Veterans Affairs

STAMP

Revisions: Date:

Drawing Title

Approved:

Phase

Building Number

VA FORM 08 - 6231

321 4 5 6 7 8 9 10

CALVERTON NATIONAL CEMETERY

COLUMBARIUM IMPROVEMENTS

ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management

BID DOCUMENTS

INTEGRITY FEDERAL SERVICES /

THE LA GROUP JOINT VENTURE

Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg

WV 25401

(304)-725-8456

The LA Group 40 Long Alley Saratoga Springs

NY 12866

(518)-587-8100

COLUMBARIUM H EXISTING CONDITIONS

/ RESTORATION ELEVATIONS - SHEET 12

CS113

14 of 99LTM BMD

COLUMBARIUM H - WALL S9 ELEVATION2 COLUMBARIUM H - WALL E2 ELEVATION3Scale: 1" = 5'

COLUMBARIUM H KEY1

2 / D

W

ALL 8

WALL 8

W

ALL 8

W

ALL 9

WALL 9

W

ALL 9

A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND

SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL

PANELS TO BE CLEANED. SEE SPECIFICATIONS.

B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN

PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE

SPECIFICATIONS.

C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE

DETAIL 1/CS501

D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.

SEE SPECIFICATIONS.

E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER

WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT

PER SPECIFICATIONS.

F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501

G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE

DETAIL 10/CS500

H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500

I. NOT APPLICABLE IN COLUMBARIUM H

RESTORATION NOTES:

1. FAILING PANEL JOINT SEALANT, TYP.

2. FAILING COPING JOINT SEALANT, TYP.

3. CRACKED PRECAST CONCRETE CAP, TYP.

4. STAINED PRECAST CONCRETE PANELS, TYP.

5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.

6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.

7. NOT APPLICABLE IN COLUMBARIUM H

8. PITTED AND SPALLING CONCRETE FLATWORK

EXISTING CONDITIONS NOTES:

6 / A

(ALL PANELS)

NOTE: ALL WALLS ON THIS SHEET TO

RECEIVE CLEANING (E)

A

H

PROTECT EXISTING

PAVEMENT TO REMAIN, TYP.

H

CS113

CS113

LEGEND:

REMOVE AND REPLACE CONCRETE FLATWORK

REMOVE EX. VEGETATION & MULCH. NEW GRAVEL

& DECORATIVE STONE PER SPECIFICATIONS

CS501

CS500

Project Title

Location

Issue Date Checked Drawn

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

SUFFOLK COUNTY, NEW YORK

805CM3048

MARCH 25, 2025

U.S. Department of Veterans Affairs

STAMP

Revisions: Date:

Drawing Title

Approved:

Phase

Building Number

VA FORM 08 - 6231

321 4 5 6 7 8 9 10

CALVERTON NATIONAL CEMETERY

COLUMBARIUM IMPROVEMENTS

ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management

BID DOCUMENTS

INTEGRITY FEDERAL SERVICES /

THE LA GROUP JOINT VENTURE

Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg

WV 25401

(304)-725-8456

The LA Group 40 Long Alley Saratoga Springs

NY 12866

(518)-587-8100

WALL SECTION KEY

WALL # SECTIONS

1 A(1-7), B(8-13), C(14-19), D(20-26)

2 A(1-7), B(8-13), C(14-19), D(20-26), E(27-22)

3 A(1-7), B(8-21), C(22-29), D(30-37), E(38-45), F(46-56)

4 A(1-7), B(8-15), C(16-22)

5 A(1-8), B(9-15), C(16-23)

6 A(1-6), B(7-11)

7 A(1-8), B(9-15), C(16-23)

8 A(1-8), B(9-15), C(16-23), D(24-34)

9 A(1-6), B(7-17), C(18-29)

10 A(1-8), B(9-16), C(17-24), D(25-30), E(31-36), F(37-42), G(43-49)

1 B2 B

E

3 B

E

D

C

B

A

B

7 B 7 C

8 B8 C

9 B9 C

B

C

10 E10 F

A

B

C

1. PRIOR TO CONSTRUCTION CONTRACTOR SHALL ARRANGE

PRE-CONSTRUCTION MEETING WITH RE/COR TO REVIEW ALL

APPLICABLE PERMIT CONDITIONS, THE CONSTRUCTIONS PLANS AND

GENERAL CONSTRUCTION SCHEDULE

2. NO WORK SHALL COMMENCE UNTIL UNDERGROUND UTILITIES WITHIN

THE WORK AREA HAVE BEEN IDENTIFIED, LOCATED AND MARKED.

THIS SHALL INCLUDE ALL CEMETERY INFRASTRUCTURE WITHIN THE

PROPOSED WORK AREA WITHIN THE PROPOSED WORK AREA THAT

MAY NOT BE PART OF TRADITIONAL UTILITY PLANS SUCH AS STORM

SEWERS, IRRIGATION, CONTROL WIRES, ETC.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE

WITH THE RE/COR ON ALL CONSTRUCTION WASTE MATERIALS TO BE

REMOVED AND RECYCLED / DISPOSED OF OFF SITE. ALL HANDLING

OF CONSTRUCTION WASTE MATERIALS TO BE REMOVED, RECYCLED

OR DISPOSED OF MUST BE DONE SO IN A SAFE, LEGAL MANNER IN

ACCORDANCE WITH ALL LOCAL, COUNTY, STATE, FEDERAL AND ANY

OTHER APPLICABLE REGULATIONS.

4. ALL ITEMS REQUIRING REMOVAL SHALL BE REMOVED TO FULL

DEPTH, INCLUDING BASE MATERIAL AND FOOTINGS OR

FOUNDATIONS AS APPLICABLE UNLESS OTHERWISE NOTED.

EXCAVATED MATERIALS UNSUITABLE FOR REUSE SHALL BE

REMOVED FROM THE SITE AND PROPERLY DISPOSED OF BY THE

CONTRACTOR.

5. EXISTING ITEMS INDICATED TO BE SALVAGED SHOULD BE

CAREFULLY REMOVED AND STORED AS DIRECTED BY THE RE/COR.

SITE PREPARATION AND DEMOLITION NOTES:

1. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE INSIDE OR

OUTSIDE THE LIMIT OF WORK DUE TO THEIR CONTRACT

OPERATIONS.

2. THE CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL

SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT,

ROADWAYS AND DRIVEWAYS .

3. THE CONTRACTOR SHALL FURNISH, INSTALL AND MAINTAIN

NECESSARY TRAFFIC CONTROL DEVICES, DRUMS, DELINEATORS,

SIGNS, FENCES AND BARRICADES IN ACCORDANCE WITH THE LATEST

EDITION OF THE NATIONAL MUTCD WITH NEW YORK STATE

SUPPLEMENT TO PROPERLY PROTECT WORK, EQUIPMENT, PERSONS

AND PROPERTY FROM DAMAGE.

4. REPAIR AND/OR RESTORE ALL DAMAGED EXISTING AREAS,

GOVERNMENT FURNISHED PROPERTY, STRUCTURES, ROADS,

UTILITIES AND OTHER ITEMS USED FOR AND/OR DURING

CONSTRUCTION TO THEIR ORIGINAL CONDITION OR BETTER.

PROTECTION AND RESTORATION NOTES:

PROPOSED

GRAVEL STRIP

PROPOSED

GRAVEL STRIP

PROPOSED

GRAVEL STRIP

PROPOSED

GRAVEL STRIP

PROPOSED

GRAVEL STRIP

REMOVE AND REPLACE

CONCRETE PAVEMENT, TYP.

CS500

CS500

CS500

CS500

CS500

COLUMBARIUM I OVERALL KEY PLAN1

GRAPHICAL SCALE: 1"=5'

5 2.5 0 5 10 15

· REMOVE CRACKED PRECAST CONCRETE PANELS AND REPLACE WITH NEW PANELS

· REMOVE AND REINSTALL LOOSE PRECAST PANELS

· REMOVE AND REINSTALL LOOSE PRECAST WALL CAPS

· REMOVE AND REINSTALL STONE WALL CAPS OVER FLASHING MATERIAL

· REPLACE ALL WALL CAP JOINT SEALANT THROUGHOUT

· REPLACE ALL WALL PANEL JOINT SEALANT THROUGHOUT

· REMOVE AND REPLACE DAMAGED CONCRETE FLATWORK

· ADD GRAVEL STRIP AT OUTSIDE PERIMETER

· REMOVE ALL EXISTING PLANTING AND MULCH FROM PLANT BEDS WITHIN COURT, REPLACE WITH PEA

GRAVEL AND DECORATIVE STONES

· SEALING WORK AT CONCRETE PAVEMENT INCLUDES REMOVAL AND REPLACEMENT OF EXPANSION JOINT

SEALANT. PROVIDE NEW SEALANT PER SPECIFICATIONS. EXPANSION JOINTS AS SHOWN ON 12'X25' GRIDS AND WHERE PAVEMENT ABUTS WALLS. CONTRACTOR TO FIELD VERIFY EXPANSION JOINT LOCATIONS

GENERAL CONSTRUCTION NOTES:

LEGEND:

REMOVE AND REPLACE CONCRETE FLATWORK

A

1 C2 C

D

3 A

F

S 4.1

BA

CK

S 4

S 5.1

BA

CK

C

S 6

A

7 A

S

8 A

D

9 A

A

10 D

G

E 2E1

S

S 1 S 10

S 5

S 1/2

A

D

COLUMBARIUM I EXISTING CONDITIONS

OVERALL KEY PLAN

CS120

15 of 99LTM BMD

PERGOLA

W

ALL 1

WALL 1

W

ALL 1

W

ALL 2

WALL 2

W

ALL 2

WALL 3

W

ALL 3

W

AL

L

W

AL

L

W

AL

L

WALL 7

WALL 8

W

AL

L

WALL 9

W

AL

L

WALL 10

W

AL

L

NOTE: WALL SECTION KEY CORRESPONDS TO PHOTOGRAPHED

WALL ELEVATIONS AND NICHE COLUMN NUMBERS

EX: WALL #1 SECTION A(1-7) CORRESPONDS TO WALL 1,

ELEVATION A, NICHE COLUMNS 1 THROUGH 7

ALL STONE MULCH IN GRAVEL

STRIPS TO BE REPLACED, TYP.

REMOVE AND RESET PRECAST CONCRETE CAP

REMOVE AND RESET

PRECAST CONCRETE

CAP, TYP.

TEMPORARY CONSTRUCTION FENCE

TEMPORARY

CONSTRUCTION FENCE

CS500

PERIMETER

SAFETY RAILING

CS505

PERIMETER SAFETY RAILINGPLANT LIST

SYM. QTY. BOTANICAL NAME COMMON NAME SIZE H x W (75%)

SHRUBS

TO 14 Thuja occidentalis 'Anna van Vloten' Anna's Magic Ball Arborvitae 2.25' x 2.25'

DO 10 Daphne odora Winter Daphne 2.25' x 2.25'

BT 6 Berberis thunbergii 'Orange Rocket' Orange Rocket Barberry 3.75' x 2.25'

CO 12 Chamaecyparis obtusa 'Nana Gracilis' Dwarf Hinoki Cypress 4.5' x 3'

CO

TO

CO

TO

CO

CO

DO

BT

CO

DO

BT

CO

CO

DO

BT

CO

DO

BT

CO

CO

TO

CO

TO

CO

S 3

REMOVE EX. VEGETATION & MULCH. NEW GRAVEL

& DECORATIVE STONE PER SPECIFICATIONS

CS500

1 & 3

CS501

CS501

EXISTING BENCH, TYP.

PROPOSED BENCH, TYP.

EXPANSION

JOINT, TYP.

CONTROL

JOINT, TYP.

EDGE OF NEW AND

EXISTING PAVEMENT

CS500

12_CS111_COLUMBARIUM H RESTORATION-H-10
Sheets and Views
H-10
13_CS112_COLUMBARIUM H RESTORATION-H-11
Sheets and Views
H-11
14_CS113_COLUMBARIUM H RESTORATION-H-12
Sheets and Views
H-12
15_CS120_COLUMBARIUM I RESTORATION-COL. I KEY
Sheets and Views
COL. I KEY

File details come from the government source that posted it. Updated .