5b. 578-26-016 CLIN1 100 Percent Bid Drawings -Part 2.pdf
PDF 20 MB Posted
- Solicitation number
- 36C25226B0028
About this file
This file contains 100% construction documents (bid drawings) for renovations to Building 217 at Edward J. Hines Jr. VAMC under VA Contract No. 578-26-016. The drawings depict architectural plans, elevations, and details for the renovation of a multi-story healthcare facility, including floor plans for the first and second floors showing patient rooms, administrative spaces, dining areas, and support facilities. The construction scope encompasses dementia patient units with 12 dedicated patient rooms (240-242 SF each) featuring associated bathrooms, bariatric patient rooms (298-308 SF), high fall-risk patient rooms (442-465 SF), conference rooms, dining facilities, equipment storage, and staff areas. Key architectural specifications include metal stud partition framing with gypsum board, acoustical tile ceilings (8'-0" standard height), concrete floor preparation with 3/4" skim coating, various partition types rated for fire and sound attenuation, and detailed casework for sinks, countertops, shelving, and millwork throughout. The drawings indicate multiple design phases completed between November 2023 and June 2026, with the final 100% Construction Documents issued on 06/10/2026. Materials and finishes specified include solid surface countertops, porcelain tile, LVT flooring, metal ceiling systems, and various hardware and equipment per referenced schedules and specifications in accompanying drawing series (AF, QH, and other related sheets).
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FEC
FE
C
FEC
FE
C
FE
C
FECFEC
FEC
J
K
H
M
L
N
O
P
Q
S
R
G
F1
E
D
C
B
A
23456789
1010.11111.111.21213141515.11617
181920212223242526
S16
S15
S14
S13
S12
S11
S10
S9
S8
S7 S6
S5
S4
S3
S2
S1
N19
N17
N15.1
N14.1
N16 N15
S19
S18
S17
S16.1
S15.1
S14.1
N14
N13
N12
N11
N10
N9
N8
N7
N6
N5
N4
N3
N2
N1
AE401
1 AE410
AE402
AE407
AE405
AE405
AE408
AE408
AE409
BEDROOM
B120
BEDROOM
B122
BEDROOM
B123
BEDROOM
B126
BEDROOM
B127
BEDROOM
B130
BEDROOM
1B131
BEDROOM
B118
LINEN
B115
STR
B115A
BEDROOM
B114
BEDROOM
B111
BEDROOM
B110
BEDROOM
B107
BEDROOM
B106 4
BEDROOM
B104
PANTRY
CONFERENCE
ROOM
B133
OFFICE
B139
SOILED
UTILITY
B146
SHOWER
ROOM
1B135
MED
ROOM
B138
OFFICE
B141
STAFF
WORK
AREA
1B142
ELECTRICAL
A139
BEDROOM
1C106
BEDROOM
1C107
BEDROOM
1C110
BEDROOM
1C111
BEDROOM
1C114
BEDROOM
1C115
BEDROOM
1C118
TOILET
1C119
BEDROOM
1C120
BEDROOM
1C122
BEDROOM
1C123
BEDROOM
1C126
BEDROOM
1C127
BEDROOM
1C130
BEDROOM
1C131
BEDROOM
1C151
BEDROOM
1C152
BEDROOM
1C155
BEDROOM
1C156
BEDROOM
1C159 1
BEDROOM
C160
BEDROOM
C162
BEDROOM
1C164
BEDROOM
1C167
BEDROOM
1C168
BEDROOM
1C171
BEDROOM
1C172
BEDROOM
1C175
BEDROOM
1C176
PHYSICAL
THERAPY
A123
P.T.
OFFICE
A124
DIETICIAN
A125
OFFICE
A128
MECHANICAL
A132
ELECTRICAL
A139
ELEVATOR
MACHINE
ROOM
A140
SOILED
LAUNDRY
HOLDING
A130
TRASH
ROOM
A131
CLEAN
LINEN
STORAGE
1B151
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - FIRST FLOOR - FLOOR
PLAN
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CR AM
578-26-016
AE101
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/16" = 1'-0"
ARCHITECTURAL - FIRST FLOOR - OVERALL PLAN
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
DN
DN
FEC
FECFEC
J
K
H
M
L
N
O
P
Q
S
R
G
F1
E
D
C
B
A
23456789
1010.11111.111.21213141515.11617
181920212223242526
S16
S15
S14
S13
S12
S11
S10
S9
S8
S7
S6
S5
S4
S3
S2
S1
N19
N17
N15.1
N14.1
N16 N15
S19
S18
S17
S16.1
S15.1
S14.1
N14
N13
N12
N11
N10
N9
N8
N7
N6
N5
N4
N3
N2
N1
AE403
AE406
AE408
AE408
AE404
AE409
AE409
TOILET
2C79
HIGH
FALL-RISK
PATIENT
ROOM
2C78
OFFICE
2B20
OFFICE
2B22
OFFICE
2B23
OFFICE
2B26
OFFICE
2B27
OFFICE
2B30
OFFICE
2B31
OFFICE
2B49
BEDROOM
2B51
BEDROOM
2B52
BEDROOM
2B55
BEDROOM
2B56
BEDROOM
2B59
BEDROOM
2B60
BEDROOM
2B62
OFFICE
2B64
BEDROOM
2B67
BEDROOM
2B68
BEDROOM
2B71
BEDROOM
2B72
BEDROOM
2B75
BEDROOM
2B76
OFFICE
2B18
OFFICE
2B15
OFFICE
2B14
OFFICE
2B11
OFFICE
2B10
OFFICE
2B07
OFFICE
2B06
OFFICE
FELLOWS
2B04
LAUNDRY
2A32
PSYCH
OFFICE
2A33
OFFICE
2A34
OCCUPATIONAL
THERAPY
2A34A
O.T.
STORAGE
2A35
OFFICE
2A36
CLEAN
LINEN
STORAGE
2A02
ELECTRICAL
2A03
MECHANICAL
2A05
HAC
SUPPLIES
2A06
STORAGE
2A07
OFFICE
2A08
BREAK
ROOM
2A14
SOCIAL
OFFICE
2A15
P.T.
OFFICE
2A16
KINESIO
THERAPY
2A17
OFFICE
2A25
BEDROOM
2C76
BEDROOM
2C75
BEDROOM
2C72
BEDROOM
2C71
BEDROOM
2C68
BEDROOM
2C67
BEDROOM
2C64
BEDROOM
2C62
BEDROOM
2C60
BEDROOM
2C59
BEDROOM
2C56
BEDROOM
2C55
BEDROOM
2C52
BEDROOM
2C51
STORAGE
C231
BEDROOM
2C30
BEDROOM
2C27
BEDROOM
2C26
BEDROOM
2C23
BEDROOM
2C22
BEDROOM
2C20
FAMILY
ROOM
2C18
BEDROOM
2C15
BEDROOM
2C14
BEDROOM
2C11
BEDROOM
2C10
BEDROOM
2C07
BEDROOM
2C06
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - SECOND FLOOR - FLOOR
PLAN
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CR AM
578-26-016
AE102
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/16" = 1'-0"
ARCHITECTURAL - SECOND FLOOR - OVERALL PLAN
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 03/28/2025
FECFEC
K
M
L
N
1111.111.21213141515.1
2247 SF
DINING
ROOM
2A18
2A18A
/1 AE403.1
A E
.1
A E
.1
/4 AE403.1
1A104D
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - ENLARGED PLAN - DINING
ROOM 2A18
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE403
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - DINING 2A26
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
AE551
Sim
RB-1
WP-1
RB-1 RB-1
WP-1
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
WP-13 WP-13 WP-13
PNL-2 PNL-2 PNL-2 PNL-2 PNL-2 PNL-2 PNL-2 PNL-2
SS-3
EQ EQ EQ EQ EQ EQ EQ EQ
5'
- 0
AE552
Sim
AE551
Sim
RB-1
WP-1
RB-1
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0225 F0225
F0225
F0225 F0780
F0225WP-1
WP-13
AE551
Sim
AE551
Sim
F0225
F0225
F0780
F0225
F0225 F0225 F0225 F0225 F0225
SS-3
WP-1
WP-1
WP-1
F0225 F0225 F0225
RB-1WP-13
SS-3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ENLARGED PLAN - DINING
ROOM 2A18
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE403.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - 2A18 EAST
1/2" = 1'-0"
ELEVATION - 2A18 NORTH
1/2" = 1'-0"
ELEVATION - 2A18 WEST
1/2" = 1'-0"
ELEVATION - 2A18 SOUTH
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
O
P
1111.111.212
MOVABLE PARTITION
31' - 7 5/16"
463 SF
CONFERENCE
ROOM
2A12A
309 SF
CONFERENCE
ROOM
2A12B
A E
.1
/3 AE404.1
A E
.1
/1 AE404.1
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
CONFERENCE ROOMS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE404
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - CONFERENCE ROOMS
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
WP-1
RB-1
WP-1
WP-1
RB-1
MOVABLE WALL PARTITION
WP-1
RB-1 RB-1
MOVABLE WALL PARTITION
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ELEVATIONS -
CONFERENCE ROOMS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE404.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - 2A12 EAST
1/2" = 1'-0"
ELEVATION - 2A12 NORTH
1/2" = 1'-0"
ELEVATION - 2A12 WEST
1/2" = 1'-0"
ELEVATION - 2A12 SOUTH
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
E
D
S19
S18
S17
N9
N8
308 SF
BARIATRIC
PATIENT
ROOM
B149
72 SF
TOILET
B148
8' - 0"
B148
B149
A E
.1
/1 AE405.1
A E
.1
A E
.1
/4 AE405.1
/5 AE405.1
A E
.1
/8
AE405.1
2' - 0"
E
DS9 S8
N19
N17
8' - 0"
8'
- 0
298 SF
BARIATRIC
PATIENT
ROOM
C149
73 SF
TOILET
C148
4 1 3/1
6"
C149
C148
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
BARIATRIC ROOMS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE405
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - BARIATRIC B149
N
1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - BARIATRIC C149
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
F0400 F0315
RB-1
SS-1
AE541
Typ.
AE541
Typ.
AE541
Typ.
RB-1
A5082 A5075
M7010
F0400SS-3
PL-2
PL-2
RB-1
M0506
F0315
RB-1
PT-2
PT-3
P-17
PT-2
PT-3
P-17
AE541
Typ.
A5082 A5075
A1067
SS-3
PT-2
PT-3
P-17
PL-2
A5082
PT-2
PT-3
P-17
308 SF
BARIATRIC
PATIENT
ROOM
B149
72 SF
TOILET
B148
8' - 0"
B148
B149
2' - 0"
F0400 F0315
M7010
M0506
A5082
A1067
A5075
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
BARIATRIC ROOMS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE405.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - B149 EAST
1/2" = 1'-0"
ELEVATION - B149 NORTH
1/2" = 1'-0"
ELEVATION - B149 SOUTH
1/2" = 1'-0"
ELEVATION - B149 WEST
1/2" = 1'-0"
ELEVATION - B148 WEST
1/2" = 1'-0"
ELEVATION - B148 NORTH
1/2" = 1'-0"
ELEVATION - B148 SOUTH
1/2" = 1'-0"
ELEVATION - B148 EAST
N
1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - BARIATRIC B149
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
FE
C
FEC
FEC
H
G
F1
E
D
C
B
A
1515.11617
N16
N15 S19
S18
S17
S16.1
S15.1
S14.1
N14
N13
N12
N11
N10
N9
N8
N6
109 SF
CLEAN
UTILITY
1B152
240 SF
DEMENTIA
PATIENT
ROOM
1B155
239 SF
DEMENTIA
PATIENT
ROOM
1B156
245 SF
DEMENTIA
PATIENT
ROOM
1B159
149 SF
MULTIPURPOSE
ROOM
1B160
238 SF
DEMENTIA
PATIENT
ROOM
1B162
236 SF
DEMENTIA
PATIENT
ROOM
1B164
232 SF
DEMENTIA
PATIENT
ROOM
1B167
238 SF
DEMENTIA
PATIENT
ROOM
1B168
235 SF
DEMENTIA
PATIENT
ROOM
1B171
239 SF
DEMENTIA
PATIENT
ROOM
1B172
235 SF
DEMENTIA
PATIENT
ROOM
1B175
8' -
3/4
242 SF
DEMENTIA
PATIENT
ROOM
1B176
0"
8' - 5 7/16"
14'
- 1
1 9 /16
14'
- 1
0 1 1/1
6"
15'
- 2
/16
0 1 /8"
1/
8"
0 1
1/1 6"
9 9 /16
1' - 0"
72 SF
BATHROOM
1B165
64 SF
BATHROOM
1B166
66 SF
BATHROOM
1B169
65 SF
BATHROOM
1B170
67 SF
BATHROOM
1B173
65 SF
BATHROOM
1B174
75 SF
BATHROOM
1B177
67 SF
BATHROOM
1B154
65 SF
BATHROOM
1B157
67 SF
BATHROOM
1B158
60 SF
PUBLIC
TOILET
1B161
78 SF
BATHROOM
1B163
1B135A
1B80B
1B80A
1B176
1B175
1B171
1B168
1B167
1B164
1B158
1B
1B154
1B180C
1B172
AE
7.
AE
7.
110 SF
SOILED
UTILITY
1B153
27 SF
CLEAN
LINEN
1B151
1B151
3' - 6"
5' - 6"
7' - 8 1
/4"
6' - 9 9
/16
13'
- 4
7/1 6"
16'
- 9
/16
6' - 8 1
5/1 6"
A E
.3
7 5 /16
3'
- 0
3'
- 0
3'
- 0
3'
- 0
3'
- 0
3'
- 0
3'
- 0
1' - 6 7/16"
1' - 2 9/16"
1' - 3 1/8"
1' - 0 5/16" 3' -
0"
3' - 0"
3' - 0"
3' - 0"
1' - 0 1/4"
1' - 0 1/4"
44 SF
STAFF
TOILET
1B135A
347 SF
STAFF
WORK
AREA
1B142
210 SF
SHOWER
ROOM
1B135
6' - 7 1/8"
AE
7.
AE407.1
AE407.2
AE407.6
A E
.2
A E
.2
1B159 1B156
1B155
1B
1B153
1B162
1B
1B165
1B
1B169
1B
1B173
1B
1B177
AE
7.
8 3 /4"
9 5 /8"
7 3 /4"
5/
8"
1/ 8"
7'
- 1
1/ 8"
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
DEMENTIA UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/8" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - DEMENTIA UNIT
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
DEMENTIA
PATIENT
ROOM
1B168
BATHROOM
1B1692' - 0"
M7010
F0400
M7040 F0315
A5075 A1067
F2010
A5082
M0506
F2010
A5082
A5075
AE543
M7040
M7010
F0400 F0315
RB-1
AE551
SimF0315
RB-1
SS-1
AE542
Typ.
2'
- 9
1/ 2"
SS-3
PL-2
RB-1
F2010
M0506
AE541
Typ.
AE541
Typ.
AE541
Typ.
RB-1
F2010
A5075
A5082
SS-3
PL-2
PL-2
2' - 11"
2' - 10"
F2010
A5170
PT-2
PT-3
P-17
PT-2
PT-2
PT-3
PT-2
A5082
F2010
PT-2
PT-3
P-17
AE541
Typ.
A1067
A5170
A5075
SS-3 PL-2
3' - 0"
2'
- 1
0"
PT-2
PT-3
P-17
PT-2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
DEMENTIA UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - TYP DEMENTIA PATIENT ROOM
1/2" = 1'-0"
ELEVATION - 1B168 NORTH
1/2" = 1'-0"
ELEVATION - 1B168 SOUTH
1/2" = 1'-0"
ELEVATION - 1B168 WEST
1/2" = 1'-0"
ELEVATION - 1B168 EAST
1/2" = 1'-0"
ELEVATION - 1B169 EAST
1/2" = 1'-0"
ELEVATION - 1B169 SOUTH
1/2" = 1'-0"
ELEVATION - 1B169 NORTH
1/2" = 1'-0"
ELEVATION - 1B169 WEST
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
WP-1 WP-2
WP-3
WP-6
RB-1
WP-1
RB-1
WP-1 WP-2
WP-3 RB-1
WP-1WP-9 WP-9
WP-9
WP-9
PL-1 PL-1 PL-1
WP-1 WP-2
WP-3 RB-1
WP-1 WP-1 WP-2
WP-3 RB-1
/3 AE407.2
AE531
Typ.
WP-9
WP-9
PL-1
PL-1 PL-1PL-1
PL-1PL-1
/2 AE407.2
WP-2
WP-3 RB-1
WP-1
WP-9
STAFF
TOILET
1B135A
A5090 A5200
A5082
A1067
A5075
A5075
A5082
A1067
PT-6
WP-14
A5200
PT-6
WP-14
A1067
A5082A5075
A5200
PT-6
WP-14
A5082
A5090 A5200
PT-6
WP-14
WP-2
WP-3RB-1
WP-9
PL-1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ELEVATIONS - DEMENTIA
UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407.2
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - DEMENTIA UNIT CORRIDOR C150 - NORTH
1/2" = 1'-0"
ELEVATION - DEMENTIA UNIT CORRIDOR C150 - SOUTH A
1/2" = 1'-0"
ELEVATION - DEMENTIA UNIT CORRIDOR C150 - SOUTH B
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
N 1/2" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - STAFF TOILET 1B135A
1/2" = 1'-0"
ELEVATION - 1B135A WEST
1/2" = 1'-0"
ELEVATION - 1B135A SOUTH
1/2" = 1'-0"
ELEVATION - 1B135A NORTH
1/2" = 1'-0"
ELEVATION - 1B135A EAST
1/2" = 1'-0"9
ELEVATION - DEMENTIA UNIT CORRIDOR C150 - SOUTH C
F0780
F0225 F0225
F0780
PT-9
M0506
SS-5
PL-1
AE542
FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1
FLM-1
FLM-1 FLM-1 FLM-15'
- 3
4' - 9"4' - 7 5/16" 4' - 6 1/4" 3' - 10 7/8" 3' - 10 7/8" 3' - 10 7/8" 3' - 10 7/8" 3' - 10 7/8" 3' - 8 11/16" 3' - 8 11/16" 5' - 0 1/4" 2' - 3"
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ELEVATIONS - DEMENTIA
UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407.3
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - DEMENTIA UNIT COMMUNITY SPACE - SOUTH
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
F0225 F0225
F0780
SS-5
PL-1
FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-15'
- 3
2' - 1 9/16" 4' - 1 9/16" 4' - 1 9/16" 4' - 1 9/16" 4' - 1 9/16" 3' - 5 7/16" 3' - 5 7/16" 3' - 5 7/16" 3' - 5 7/16" 3' - 5 11/16" 3' - 4 11/16"
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ELEVATIONS - DEMENTIA
UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407.4
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - DEMENTIA UNIT COMMUNITY SPACE - NORTH
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
SS-5
PL-1
FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1 FLM-1FLM-1
5'
- 3
3' - 4 11/16" 3' - 5 11/16" 3' - 5 7/16" 3' - 5 7/16" 3' - 5 7/16" 3' - 5 7/16" 4' - 1 9/16" 4' - 1 9/16" 4' - 1 9/16" 4' - 1 9/16" 2' - 1 9/16"
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ELEVATIONS - DEMENTIA
UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407.5
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - DEMENTIA UNIT COMMUNITY SPACE - FACING SOUTH CORRIDOR
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
E
D
S18
S17
S16.1
N11
A E 407.6
A E
7.
/ 3
A E 407.6
AE
7.
/ 2
A E 407.6
AE
7.
2' - 9"
2' - 9"
12' - 10 1/16"
3' - 6 5/8"
R 1 ' - 0"
R 6 ' - 0
1' - 3 15/16"
19' - 4 1/2"
21.52°
141.66°
A E
.2
A E
.2
AE542
Typ.
AE542
Typ.
AE542
Typ.
F0225F0225F0225F0225
SS-5
PL-1
WP-7 WP-7
WP-20
WP-20
RB-1
F0225F0225F0225F0225 F0280 F0225 F0280F0280
SS-5
PL-1
WP-7 WP-7 WP-7
WP-20
WP-20
WP-20
F0280 F0280
WP-20
WP-7
F0225 F0225 F0225 WP-20
WP-7
AE541
Typ.
AE541
Typ.
AE541
Typ.
1A
AE541
Typ.5
AE541
Typ. 5
AE541
Typ.
2' - 0" 4' - 0" 4' - 0"
4' - 0"
SLOPED TOP
PL-1
PL-1
2' - 0"2' - 0"2' - 0"
SS-1
3' - 0"3' - 0"
PT-5
RB-1
F0225
WP-20
WP-7
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
DEMENTIA UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407.6
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - NURSE STATION AND NOURISHMENT
1/2" = 1'-0"2
ELEVATION - NURSE STATION - FRONT OF NURSE STATION
1/2" = 1'-0"3
ELEVATION - NURSE STATION - LOOKING BEHIND NURSE STATION
1/2" = 1'-0"4
ELEVATION - NURSE STATION - RIGHT
1/2" = 1'-0"5
ELEVATION - NURSE STATION - LEFT
1/2" = 1'-0"6
ELEVATION - NURSE STATION - BEHIND NURSE STATION
1/2" = 1'-0"7
ELEVATION - NURSE STATION - LEFT LOOKING OUT OF NURSE STATION
SS-5
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
H
G
11.212
442 SF
HIGH
FALL-RISK
PATIENT
ROOM
1C104
71 SF
TOILET
1C105
1C105
1C104
9'
- 4
1/ 8"
7"
7' - 5 3/8"
11' - 9 11/16"
/2 AE408.1
A E
.1
/5 AE408.1
A E
.1
A E
.1
/8 AE408.1
/6 AE408.1
A E
.1
2'
- 0
K
M
L
N14.1
465 SF
HIGH
FALL-RISK
PATIENT
ROOM
1C178
67 SF
TOILET
1C179
1C179
1C178
9' - 4 1/8"
7'
- 8
3/
2 1 /4"
7"
H
G
11.212
441 SF
HIGH
FALL-RISK
PATIENT
ROOM
2C4
72 SF
TOILET
2C5
2C4
2C5
9'
- 4
1/ 8"
7' - 5 3/8"
11' - 9 5/8"
7"
K
M
L
N14.1
454 SF
HIGH
FALL-RISK
PATIENT
ROOM
2C78
67 SF
TOILET
2C79
9' - 4 1/8"
7'
- 8
1/ 4"
2C78
2C79
2 1 /4"
7"
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL -ENLARGED PLAN - HIGH
FALL RISK ROOMS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE408
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECUTRAL - ENLARGED PLAN - HIGH FALL-RISK ROOM 1C104
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - HIGH FALL-RISK ROOM 1C178
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - HIGH FALL-RISK ROOM 2C204
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - HIGH FALL-RISK ROOM 2C78
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
AE541
Typ.
AE541
Typ.
AE541
Typ.
A5082 A5075
F2010
SS-3
PL-2
PL-2
M7010
F0400
M7040
RB-1
AE551
Sim
AE551
SimF0315
WP-2
RB-1
SS-1
WP-2
RB-1
F0315
WP-2 WP-2
M0506
F2010
PT-2
PT-3
P-17
A5200 PT-2
PT-3
P-17
A5075 A5082
A1067
A5200
PT-2
PT-3
P-17
SS-3
PL-2
A5082
F2010 PT-2
PT-3
P-17
WP-2
RB-1
442 SF
HIGH
FALL-RISK
PATIENT
ROOM
1C104
71 SF
TOILET
1C105
1C105
1C104
F2010A5075 A5082
F0315
A5082 A1067 A5075
F2010
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL -ENLARGED PLAN - HIGH
FALL RISK ROOMS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE408.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - 1C104 EAST
1/2" = 1'-0"
ELEVATION - 1C104 NORTH
1/2" = 1'-0"
ELEVATION - 1C104 WEST
1/2" = 1'-0"
ELEVATION - 1C105 EAST
1/2" = 1'-0"
ELEVATION - 1C105 SOUTH
1/2" = 1'-0"
ELEVATION - 1C105 WEST
1/2" = 1'-0"
ELEVATION - 1C105 NORTH
1/2" = 1'-0"
ELEVATION - 1C104 SOUTH
N 1/4" = 1'-0"
ARCHITECUTRAL - ENLARGED PLAN - HIGH FALL-RISK ROOM 1C104
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
G
S15.1
61 SF
NOURISHMENT
2B41
/9 AE409.1
/10 AE409.1
A E
.1
A E
.1
H
G
1515.116
S14.1
472 SF
FAMILY
ROOM
2B78
A E
.1
/7 AE409.1
A E
.1
/8 AE409.1
H
G
1515.116
S14.1
260 SF
EQUIPMENT
STORAGE
1B178A
7' - 0" 5 5/8" 8' - 0 1/4" 9' - 3 5/16"
8'
- 4
1/ 4"
4'
- 8
7/ 8"
6"58 SF
TOILET
ROOM
1B179
108 SF
WOUND
CARE
STORAGE
1B178B
1B178B
1B178A
1B
7'
- 5
1/ 8"
/2 AE409.1
/4 AE409.1
A E
.1
A E
.1
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
EQUIPMENT STORAGE
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE409
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - NOURISHMENT 2B41
N 1/4" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - FAMILY ROOM 2B78
N 1/4" = 1'-0"
ARCHITECTURAL -ENLARGED PLAN - EQUIPMENT 1B178
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
A5082
F2010
A5200A5090
PT-6
A1067
A5075
PT-6
A1067
A5082
F2010
PT-6
RB-1
2'
- 1
0"
1' - 9" 2' - 0"2' - 0"
SS-3
PL-1
SS-3 PL-1
AE551
Sim
AE551
Sim
SS-1
RB-1 RB-1RB-1
2' - 6"
2'
- 1
0"
2'
- 8
3/ 4"
2' - 0" 2' - 0"
SS-3
SS-3
PL-1
PL-1
RB-1
RB-1
SS-3
PL-1
SLOPED TOP
RB-1
PL-1
SS-3
4' - 0"
3'
- 0
1/ 8"
1 1/2" CABINET FILLER
3'
- 2
8"
1' - 0"3' - 10 1/2"
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
EQUIPMENT STORAGE
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE409.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - 1B179 NORTH
1/2" = 1'-0"
ELEVATION - 1B179 EAST
1/2" = 1'-0"
ELEVATION - 1B179 SOUTH
1/2" = 1'-0"
ELEVATION - 1B179 WEST
1/2" = 1'-0"
ELEVATION - 2B78 NORTH
1/2" = 1'-0"
ELEVATION - 2B78 SOUTH
1/2" = 1'-0"
ELEVATION - 2B78 EAST
1/2" = 1'-0"
ELEVATION - 2B78 WEST
1/2" = 1'-0"
ELEVATION - 2B41 NORTH
1/2" = 1'-0"
ELEVATION - 2B41 EAST
1/2" = 1'-0"
ELEVATION - 2B41 SOUTH
1/2" = 1'-0"
ELEVATION - 2B41 WEST
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
PT-6
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO. 06/10/2026
ARCHITECTURAL - ENLARGED PLAN -
PLAYGROUND
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE411
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/8" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - PLAYGROUND
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
A. RESEED AREAS WHERE PLAYGROUND EQUIPMENT AND RAILROAD TIES
WERE REMOVED PER BELOW:
SEEDING: UNIFORMLY BROADCAST SEED AT RATE OF 8 POUNDS PER 1000
SQUARE FEET). USE BROADCAST OR DROP SEEDERS. SOW ONE-HALF SEED IN
ONE DIRECTION AND SOW REMAINDER AT RIGHT ANGLES TO FIRST SOWING.
COVER SEED UNIFORMLY TO MAXIMUM 6 MM (1/4 INCH) DEEP IN CLAY SOILS
AND 13 MM (1/2 INCH) DEEP IN SANDY SOILS BY MEANS OF SPIKE-TOOTH
HARROW, CULTIPACKER, RAKING, OR OTHER APPROVED DEVICE.
ROLLING: IMMEDIATELY AFTER SEEDING, FIRM ENTIRE AREA, EXCEPT FOR
SLOPES IN EXCESS OF 3 TO 1, WITH ROLLER NOT EXCEEDING 130 KG/M
(90 LB./FT.) OF ROLLER WIDTH. ELIMINATE ROLLING IF SEEDING IS DONE WITH
CULTIPACKER TYPE SEEDER.
B. SHRUB PLANTING
MOVE PLANT MATERIALS ONLY BY SUPPORTING ROOT BALL OR CONTAINER.
SET PLANTS ON HAND COMPACTED LAYER OF PREPARED BACKFILL SOIL
MIXTURE 150 MM (6 INCHES) THICK AND HOLD PLUMB IN CENTER OF PIT UNTIL
SOIL HAS BEEN TAMPED FIRMLY AROUND ROOT BALL.
SET PLANT MATERIALS IN RELATION TO SURROUNDING FINISH GRADE 25 TO
50 MM (1 TO 2 INCHES) ABOVE DEPTH AT WHICH THEY WERE GROWN IN
NURSERY, COLLECTING FIELD, OR CONTAINER. REPLACE PLANT MATERIAL
WHOSE ROOT BALLS ARE CRACKED OR DAMAGED EITHER BEFORE OR DURING
PLANTING PROCESS.
PLACE BACKFILL SOIL MIXTURE ON PREVIOUSLY SCARIFIED SUBSOIL TO
COMPLETELY SURROUND ROOT BALLS AND BRING TO SMOOTH AND EVEN
SURFACE, BLENDING INTO EXISTING AREAS.
BALLED AND BURLAPPED STOCK: BACKFILL WITH PREPARED SOIL MIXTURE TO
APPROXIMATELY HALF BALL DEPTH THEN TAMP AND WATER. CAREFULLY
REMOVE OR FOLD BACK EXCESS BURLAP AND TYING MATERIALS FROM TOP
TO MINIMUM 1/3 DEPTH FROM TOP OF ROOT BALL. TAMP AND COMPLETE
BACKFILL, PLACE MULCH TOPDRESSING, AND WATER. REMOVE WIRES AND
NON-BIODEGRADABLE MATERIALS FROM PLANT PIT BEFORE BACKFILLING.
GENERAL NOTES
WAP
WAP
J
J
N
OS
OS
OS
OS
N
WAP
K
M
L
N
1111.111.21213141515.1
DINING
ROOM
2A18
9' - 0"
9' - 0"
2'
- 0
3'
- 3
3' - 3 1/2"
AE531
Typ.
47' - 9 9/16"
82.64°
2'
- 2
5/ 8"
R 5' - 9"
2 3 /16
GENERAL NOTES
REFLECTED CEILING PLAN
A. REFER TO GENERAL NOTES ON GI001 AND GI002.
B. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL, ELECTRICAL, AND
STRUCTURAL DRAWINGS FOR FULL SCOPE OF CONSTRUCTION
WORK.
C. ANY FIRE PROTECTION, PLUMBING, MECHANICAL OR ELECTRICAL
ITEMS SHOWN ON THIS PLAN ARE FOR LOCATIONAL REFERENCE
ONLY. CONFLICTS BETWEEN DISCIPLINES SHALL BE BROUGHT TO
THE VA/COR’S ATTENTION FOR REVIEW BY THE ARCHITECT PRIOR
TO BID.
F. ALL CEILING HEIGHTS ARE 8'-0" UNLESS NOTED OTHERWISE.
G. CENTER ALL CEILING GRIDS WITHIN THE ROOM UNLESS NOTED
OTHERWISE.
H. CEILING MOUNTED ITEMS SHALL BE CENTERED IN TILE UNLESS
NOTED OTHERWISE.
I. REFER TO FINISH SCHEDULES FOR CEILING FINISHES.
EXISTING
CONSTRUCTION TO
REMAIN
NEW PARTITION
WALL
2'X2' ACT SYSTEM
GYPSUM BOARD
NURSE CALL,
CEILING MOUNTED
DOME LIGHT
CEILING MOUNTED
SMOKE DETECTOR
OCCUPANCY
SENSOR
RECESSED LINEAR
LED LIGHT W/
EMERGENCY
BACKUP
RECESSED 4'
DIAMETER
DOWNLIGHT
LINEAR METAL
CEILING - BASIS OF
DESIGN:
ARMSTRONG
METALWORKS
LINEAR - SYNCHRO
6" PLANK -
EFFECTS ALMOND
2'X4' LED
RECESSED
LINEAR LED
LIGHT
2'X2' LED
WIRELESS
ACCESS
POINT
EXIT SIGN
NEW SPRINKLER
HEAD
RECESSED CAN
COVE LIGHTING
SECURITY
CAMERA
DOWNLIGHT
2'X4' LED W/
EMERGENCY
BACKUP
UNDERCABINET LIGHT
NURSE CALL DOME
LIGHT
SMOKE DETECTOR
OCCUPANCY SENSOR
MECHANICAL -
RETURN
MECHANICAL -
SUPPLY
MECHANICAL -
LINEAR SUPPLY
MECHANICAL -
EXHAUST
SECURITY CAMERA
DOME
WALL MOUNTED FIRE
ALARM HORN/STROBE
DEVICE
DISTRIBUTED
ANTENNA SYSTEM
OS
S D
REFLECTED CEILING PLAN LEGEND
N
F
OS
F
DAS
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - REFLECTED CEILING
PLAN - DINING ROOM 2A26
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AC403
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - SECOND FLOOR - REFLECTED CEILING PLAN - DINING ROOM 2A26
Revisions: Date:
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
J
OS
OS
N
WAP
O
P
1111.111.212
CONFERENCE
ROOM
2A12A
CONFERENCE
ROOM
2A12B
9' - 0"
9' - 0"
AE531
Typ.
8 3 /4"
4' - 0"
3'
- 2
1/ 8"
GENERAL NOTES
REFLECTED CEILING PLAN
A. REFER TO GENERAL NOTES ON GI001 AND GI002.
B. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL, ELECTRICAL, AND
STRUCTURAL DRAWINGS FOR FULL SCOPE OF CONSTRUCTION
WORK.
C. ANY FIRE PROTECTION, PLUMBING, MECHANICAL OR ELECTRICAL
ITEMS SHOWN ON THIS PLAN ARE FOR LOCATIONAL REFERENCE
ONLY. CONFLICTS BETWEEN DISCIPLINES SHALL BE BROUGHT TO
THE VA/COR’S ATTENTION FOR REVIEW BY THE ARCHITECT PRIOR
TO BID.
F. ALL CEILING HEIGHTS ARE 8'-0" UNLESS NOTED OTHERWISE.
G. CENTER ALL CEILING GRIDS WITHIN THE ROOM UNLESS NOTED
OTHERWISE.
H. CEILING MOUNTED ITEMS SHALL BE CENTERED IN TILE UNLESS
NOTED OTHERWISE.
I. REFER TO FINISH SCHEDULES FOR CEILING FINISHES.
EXISTING
CONSTRUCTION TO
REMAIN
NEW PARTITION
WALL
2'X2' ACT SYSTEM
GYPSUM BOARD
NURSE CALL,
CEILING MOUNTED
DOME LIGHT
CEILING MOUNTED
SMOKE DETECTOR
OCCUPANCY
SENSOR
RECESSED LINEAR
LED LIGHT W/
EMERGENCY
BACKUP
RECESSED 4'
DIAMETER
DOWNLIGHT
LINEAR METAL
CEILING - BASIS OF
DESIGN:
ARMSTRONG
METALWORKS
LINEAR - SYNCHRO
6" PLANK -
EFFECTS ALMOND
2'X4' LED
RECESSED
LINEAR LED
LIGHT
2'X2' LED
WIRELESS
ACCESS
POINT
EXIT SIGN
NEW SPRINKLER
HEAD
RECESSED CAN
COVE LIGHTING
SECURITY
CAMERA
DOWNLIGHT
2'X4' LED W/
EMERGENCY
BACKUP
UNDERCABINET LIGHT
NURSE CALL DOME
LIGHT
SMOKE DETECTOR
OCCUPANCY SENSOR
MECHANICAL -
RETURN
MECHANICAL -
SUPPLY
MECHANICAL -
LINEAR SUPPLY
MECHANICAL -
EXHAUST
SECURITY CAMERA
DOME
WALL MOUNTED FIRE
ALARM HORN/STROBE
DEVICE
DISTRIBUTED
ANTENNA SYSTEM
OS
S D
REFLECTED CEILING PLAN LEGEND
N
F
OS
F
DAS
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
06/10/2026
ARCHITECTURAL - REFLECTED CEILING
PLAN - LIBRARY 2A12
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AC404
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/4" = 1'-0"
ARCHITECTURAL - SECOND FLOOR - REFLECTED CEILING PLAN - LIBRARY 2A12
Revisions: Date:
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
W A
P
N
J
W A
PS
F
F
J
J
J
N
N
WAP
E
D
S19
S18
S17
N9N8
BARIATRIC
PATIENT
ROOM
B149
TOILET
B148
AE531
Typ.
AE531
Typ.
1' - 6" 7'
- 6
7' - 0"
8' - 0"
8' - 0"
E
DS9 S8
N19
N17
BARIATRIC
PATIENT
ROOM
C149
TOILET
C148
7'
- 6
1' - 6"
8'
- 8
1/ 2"
7' - 0"
8' - 0"
8' - 0"
GENERAL NOTES
REFLECTED CEILING PLAN
A. REFER TO GENERAL NOTES ON GI001 AND GI002.
B. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL, ELECTRICAL, AND
STRUCTURAL DRAWINGS FOR FULL SCOPE OF CONSTRUCTION
WORK.
C. ANY FIRE PROTECTION, PLUMBING, MECHANICAL OR ELECTRICAL
ITEMS SHOWN ON THIS PLAN ARE FOR LOCATIONAL REFERENCE
ONLY. CONFLICTS BETWEEN DISCIPLINES SHALL BE BROUGHT TO
THE VA/COR’S ATTENTION FOR REVIEW BY THE ARCHITECT PRIOR
TO BID.
F. ALL CEILING HEIGHTS ARE 8'-0" UNLESS NOTED OTHERWISE.
G. CENTER ALL CEILING GRIDS WITHIN THE ROOM UNLESS NOTED
OTHERWISE.
H. CEILING MOUNTED ITEMS SHALL BE CENTERED IN TILE UNLESS
NOTED OTHERWISE.
I. REFER TO FINISH SCHEDULES FOR CEILING FINISHES.
EXISTING
CONSTRUCTION TO
REMAIN
NEW PARTITION
WALL
2'X2' ACT SYSTEM
GYPSUM BOARD
NURSE CALL,
CEILING MOUNTED
DOME LIGHT
CEILING MOUNTED
SMOKE DETECTOR
OCCUPANCY
SENSOR
RECESSED LINEAR
LED LIGHT W/
EMERGENCY
BACKUP
RECESSED 4'
DIAMETER
DOWNLIGHT
LINEAR METAL
CEILING - BASIS OF
DESIGN:
ARMSTRONG
METALWORKS
LINEAR -…
This is the start of the file's text. The full file is on GovTribe.