This document is Addendum #2 to a federal construction contract for renovations to Building 217 at Edward J. Hines Jr. VAMC in Hines, Illinois, issued on 08/20/2026. The addendum modifies contract documents for CLIN 001 Phase 2 under Contract No. 36C25223C0071.
The addendum specifies revisions to architectural drawings and specifications. Drawing modifications include: Sheet AD407 showing demolition of Stairwell Door 1-1; Sheet AE403.1 adding dimension clarity for borrowed light panel height in Dining Room 2A18; Sheet AE407 showing installation of new stairwell door 1-1; and Sheet AE601 adding Door 1-1 to the door schedule while revising doors 1B80A, 1B80B, and 1B180C to hollow metal with paint finish, changing door C148 frame type to F3, and updating door 1B151 hardware set to HW-SH-9. Specification Section 08 71 00 (Door Hardware) incorporates two new hardware sets: HW-1A and HW-SH-9. Section 32 90 00 (Planting) adds a new specification section for re-seeding requirements. The document also includes comprehensive architectural details, door schedules, hardware specifications, and planting specifications supporting the renovation project at this Veterans Affairs Medical Center facility.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TO: Chuck Smith, COR
Edward J. Hines Jr. VAMC
5000 5th Ave, Hines, IL 60141
PROJECT NAME: Renovations to Building 217 – CLIN 001 Phase 2
CONTRACT NO: 36C25223C0071
STATION PROJECT NO: 578-20-002
A/E PROJECT NO: 23-009
Addendum #2
ISSUE DATE: 08/20/2026
The following instructions and the listed documents below are hereby modified to be incorporated as part of the contract documents.
Drawings:
Sheet AD407 ARCHITECTURAL – ENLARGED DEMOLITION PLAN – DEMENTIA UNIT
1. Revision to show demolition of Stairwell Door 1-1.
Sheet AE403.1 ARCHITECTURAL – ENLARGED PLAN – DINING ROOM 2A18
1. Dimension added to clarify height of borrowed light PNL-2 above finished floor.
Sheet AE407 ARCHITECTURAL – ENLARGED PLAN – DEMENTIA UNIT
1. Revision to show installation of new stairwell door 1-1.
Sheet AE601
1. Added Door 1-1 to schedule.
2. Revised Doors 1B80A, 1B80B, and 1B180C to be HM with paint finish.
3. Revised Frame type for Door C148 to F3.
4. Revised Hardware set for door 1B151 to HW-SH-9.
Specifications
Section 08 71 00
1. Added door hardware set HW-1A.
2. Added door hardware set HW-SH-9.
Section 32 90 00
1. Added specification section to provide requirements for re-seeding.
END OF Addendum #2
H
G
F1
E
D
C
B
A
1515.11617
N16N15
S19
S18
S17
S16.1
S15.1
S14.1
N14
N13
N12
N11 N10
N9
N8
N6
ADP.1
ADP.1
ADP.1
ADP.2
ADP.2
ADP.4
ADP.1
ADP.1
ADP.1
ADP.2
ADP.2
ADP.4
ADP.1
ADP.1
ADP.1
ADP.2 ADP.2
ADP.4
ADP.1
ADP.1
ADP.2
ADP.4
ADP.1
ADP.2
ADP.1
ADP.1
ADP.1
ADP.4
ADP.2
ADP.2
ADP.2
ADP.1
ADP.1
ADP.2
ADP.1
ADP.1
ADP.2
ADP.2
ADP.1
ADP.1
ADP.1
ADP.4
ADP.2
ADP.1
ADP.1
ADP.1
ADP.2
ADP.2
ADP.4
ADP.1
ADP.1
ADP.1
ADP.2
ADP.2
ADP.4
ADP.2
ADP.1
ADP.4
ADP.2
ADP.1
ADP.1
ADP.1
ADP.1
ADP.2
ADP.4
ADP.1
ADP.2
ADP.1
ADP.1
ADP.3
ADP.3
ADP.3
ADP.3
ADP.2
ADP.2
ADP.10
ADP.11
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.12
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.18
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.20
ADP.2
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.21
ADP.1
ADP.1 ADP.23
MECHANICAL
1A114
PANTRY
1B136
SOILED
UTILITY
1B146
HAC
1B147
SHOWER
1B135
CONFERENCE
ROOM
1B133
TOILET
1B148
SOILED
UTILITY
1B151
BEDROOM
1B152
TOILET
1B153
BEDROOM
1B155
BEDROOM
1B156
TOILET
1B157
BEDROOM
1B159
TOILET
1B161
BEDROOM
1B160
BEDROOM
1B164
TOILET
1B165
BATH
1B166
BEDROOM
1B167
BEDROOM
1B168
TOILET
1B169
BEDROOM
1B171
BEDROOM
1B172
BEDROOM
1B175
BEDROOM
1B176
TOILET
1B177
BEDROOM
1B178
TOILET
1B179
TOILET
1B173
TOILET
1B174
TOILET
1B170
TOILET
1B158
TOILET
1B154
EQUIP.
ROOM
1B151A
OFFICE
1B139
OFFICE
1B141
ELECT.
1B143
SUPPLY
1B142
STORAGE
1B145
EMS
1B145A
LOUNGE
1B80
BEDROOM
1B162
82 SF
BATH
1B163
313 SF
BEDROOM
1B149
STAFF
TOILET
1B135A
A. REFER TO GI003 “CONSTRUCTION PERIOD STAGING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO DEMOLITION NOTES ON GI002.
C. ON SURFACES AND PARTITIONS INDICATED TO REMAIN, REMOVE ALL
WALL MOUNTED ITEMS AND DEVICES INCLUDING CORNER GUARDS,
HANDRAILS, CHAIR RAILS, AND ALL SURFACE FINISHES INCLUDING
CERAMIC WALL TILE AND VINYL WALL COVERING. REFER TO NOTES
AND SPECIFICATIONS REGARDING PREPARATION OF SURFACES FOR
NEW FINISHES.
D. WHERE EXISTING CONSTRUCTION IS INDICATED TO BE REMOVED,
REMOVE ALL MOUNTED ACCESSORIES, CORNER GUARDS,
HANDRAILS, ETC. PATCH ABUTTING WALLS, FLOORS, CEILINGS, AND
ROOF AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION.
REMOVE EXISTING ITEMS SCHEDULED TO REMAIN AS NECESSARY TO
ALLOW THE COMPLETE DEMOLITION WORK. REPAIR/REPLACE SUCH
ITEMS ONCE DEMOLITION IS COMPLETED.
E. IN AREAS OF WORK, CONTRACTOR TO REMOVE ALL EXISTING FLOOR
FINISHES AND ASSOCIATED MASTIC AND PREP FOR NEW FLOORING
AS SCHEDULED.
F. REFER TO CORRESPONDING STRUCTURAL, HAZARDOUS, AND
M/E/P/FP SHEETS FOR FULL SCOPE OF DEMOLITION WORK.
G. SEE M/E/P/FP AND STRUCTURAL DRAWINGS FOR ADDITIONAL
OPENINGS THAT MAY BE REQUIRED THROUGH EXISTING PARTITIONS
AND WALLS INDICATED TO REMAIN. PROVIDE SHOP DRAWINGS FOR
COORDINATION.
GENERAL NOTES DEMOLITION
FLOOR PLAN
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED, INCLUDING ALL
MOUNTED ACCESSORIES, CORNER GUARDS, HANDRAILS,
ETC. PATCH ABUTTING WALLS, FLOORS, CEILINGS AND
ROOF AS REQUIRED. REMOVE EXISTING ITEMS SCHEDULED
TO REMAIN AS NECESSARY TO ALLOW THE COMPLETE
DEMOLITION OF SELECTED ITEMS. REPAIR/REPLACE
EXISTING ITEMS ONCE DEMOLITION IS COMPLETED.
DEMOLITION PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
08/20/2026
ARCHITECTURAL - ENLARGED DEMOLITION
PLAN - DEMENTIA UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AD407
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/8" = 1'-0"
ARCHITECTURAL - DEMOLITION PLAN - ENLARGED - DEMENTIA UNIT
ADP.1 REMOVE REMOVE EXISTING PLUMBING FIXTURE AND ALL ASSOCIATED
CARRIERS IN THEIR ENTIRETY. SEE PLUMBING DRAWINGS FOR EXTENT
OF PIPING AND ACCESSORY DEMOLITION.
ADP.2 REMOVE EXISTING DOOR AND FRAME IN ITS ENTIRETY.
ADP.3 REMOVE EXISTING CASEWORK IN ITS ENTIRETY.
ADP.4 REMOVE EXISTING METAL FOOTLOCKER IN ITS ENTIRETY. PATCH AND
PAINT EXISTING WALLS WITHIN ALCOVE CREATED BY REMOVAL OF
FOOTLOCKER AS TO LEAVE NO EVIDENCE OF PATCHING.
ADP.10 REMOVE EXISTING FURNITURE SYSTEM NURSES STATION IN ITS
ENTIRETY.
ADP.11 REMOVE PORTION OF EXISTING WALL TO ALLOW FOR INSTALLATION
OF DOOR.
ADP.12 REMOVE EXISTING QUARTZ WINDOW SILL IN ITS ENTIRETY. PREP
OPENING FOR INSTALLATION OF WINDOW SILL AS SCHEDULED.
ADP.18 REMOVE PORTION OF EXISTING CONCRETE SLAB ON GRADE.
ADP.20 REMOVE EXISTING GYPSUM BOARD AND INSULATION ON INTERIOR
FACE OF EXISTING WALL. PREP EXISTING STUDS FOR INSTALLATION
OF INSULATION AND GYPSUM BOARD.
ADP.21 REMOVE EXISTING FLOOR FINISH IN ITS ENTIRETY. LEVEL EXISTING
SUBFLOOR, ASSUME MINIMUM 3/4" DEPTH OF LEVELING. PREP FLOOR
PER MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF NEW
FINISHES.
ADP.23 REMOVE EXISTING HIGH DENSITY STORAGE SHELVING AND TRACKS IN
THEIR ENTIRETY.
DEMOLITION PLAN KEY NOTES
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
Addendum #2 08/20/2026
AE551
Sim
RB-1
WP-1
RB-1 RB-1
WP-1
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
WP-13 WP-13 WP-13
PNL-2 PNL-2 PNL-2 PNL-2 PNL-2 PNL-2 PNL-2 PNL-2
SS-3
EQ EQ EQ EQ EQ EQ EQ EQ
5'
- 0
AE552
Sim
3'
- 0
AE551
Sim
RB-1
WP-1
RB-1
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0780
F0225
F0225 F0225
F0225
F0225 F0780
F0225WP-1
WP-13
AE551
Sim
AE551
Sim
F0225
F0225
F0780
F0225
F0225 F0225 F0225 F0225 F0225
SS-3
WP-1
WP-1
WP-1
F0225 F0225 F0225
RB-1WP-13
SS-3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
08/20/2026
ARCHITECTURAL - ENLARGED PLAN - DINING
ROOM 2A18
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE403.1
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
1/2" = 1'-0"
ELEVATION - 2A18 EAST
1/2" = 1'-0"
ELEVATION - 2A18 NORTH
1/2" = 1'-0"
ELEVATION - 2A18 WEST
1/2" = 1'-0"
ELEVATION - 2A18 SOUTH
Revisions: Date:
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
FEC
F E
C
FEC
FEC
H
G
F1
E
D
C
B
A
1515.11617
N16
N15
S19
S18
S17
S16.1
S15.1
S14.1
N14
N13
N12
N11
N10
N9
N8
N6
109 SF
CLEAN
UTILITY
1B152
240 SF
DEMENTIA
PATIENT
ROOM
1B155
239 SF
DEMENTIA
PATIENT
ROOM
1B156
245 SF
DEMENTIA
PATIENT
ROOM
1B159
149 SF
MULTIPURPOSE
ROOM
1B160
238 SF
DEMENTIA
PATIENT
ROOM
1B162
236 SF
DEMENTIA
PATIENT
ROOM
1B164
232 SF
DEMENTIA
PATIENT
ROOM
1B167
238 SF
DEMENTIA
PATIENT
ROOM
1B168
235 SF
DEMENTIA
PATIENT
ROOM
1B171
239 SF
DEMENTIA
PATIENT
ROOM
1B172
235 SF
DEMENTIA
PATIENT
ROOM
1B175
8' -
3/4
242 SF
DEMENTIA
PATIENT
ROOM
1B176
0"
8' - 5 7/16"
' - 1
1 9 /16
' - 1
0 1 1/1
6"
' - 2
/16
1/
8"
/8
/1
6"
9/
1' - 0"
72 SF
BATHROOM
1B165
64 SF
BATHROOM
1B166
66 SF
BATHROOM
1B169
65 SF
BATHROOM
1B170
67 SF
BATHROOM
1B173
65 SF
BATHROOM
1B174
75 SF
BATHROOM
1B177
67 SF
BATHROOM
1B154
65 SF
BATHROOM
1B157
67 SF
BATHROOM
1B158
60 SF
PUBLIC
TOILET
1B161
78 SF
BATHROOM
1B163
1B135A
1B80B
1B80A
1B176
1B175
1B171
1B168
1B167
1B164
1B158
1B
1B154
1B180C
1B172
A E .5
A E .4
110 SF
SOILED
UTILITY
1B153
27 SF
CLEAN
LINEN
1B151
1B151
3' - 6"
5' - 6"
7' - 8 1
/4"
6' - 9 9
/16
' - 4
7/1 6"
' - 9
/16
6' - 8 1
5/1 6"
A E
.3
5/
3'
- 0
3'
- 0
3'
- 0
3'
- 0
3'
- 0
3'
- 0
3'
- 0
1' - 6 7/16"
1' - 2 9/16"
1' - 3 1/8"
1' - 0 5/16"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
1' - 0 1/4"
1' - 0 1/4"
44 SF
STAFF
TOILET
1B135A
347 SF
STAFF
WORK
AREA
1B142
210 SF
SHOWER
ROOM
1B135
6' - 7 1/8"
A E .2
AE407.1
AE407.2
AE407.6
A E
.2
A E
.2
1B159 1B156
1B155
1B
1B153
1B162
1B
1B165
1B
1B169
1B
1B173
1B
1B177
A E .2
3/
4"
5/ 8"
3/
4"
/8
/8
7'
- 1
/8
STAIR
1-1
1-1
A. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK –
GENERAL NOTES” REGARDING THE VA’S DISCRETION IN SELECTING
WORK TO BE DONE AFTERHOURS/OFF-HOURS.
B. REFER TO GI002 “CONSTRUCTION PERIOD SCHEDULING OF WORK
C. REFER TO GENERAL NOTES ON GI001 AND GI002.
D. REFER TO SHEET SERIES AF AND QH FOR FINISHES AND EQUIPMENT.
E. REFER TO SHEET ANNN FOR DETAILS FOR WALL GUARDS, CRASH
RAILS, HANDRAILS, INTEGRAL COVE BASE, CORNER GUARDS.
F. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING
FIRE PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR FULL SCOPE OF CONSTRUCTION WORK.
G. UNLESS OTHERWISE NOTED ALL WALLS TO BE TYPE '1'. REFER TO
SHEET AE501 FOR PARTITION TYPES.
H. REFER TO SHEET AE601 FOR DOOR AND WINDOW SCHEDULES.
I. ALL DIMENSIONS ARE TO THE FINISHED FACE.
J. SEAL/FIRESTOP ALL OPENINGS IN ALL FIRE RATED WALLS TO
CREATE A CONTINUOUS SYSTEM. INCLUDES ALL EXPOSED CONDUIT
AND PIPING.
K. EACH PARTITION NOTED TO CARRY AN ACOUSTIC RATING SHALL
CARRY THAT RATING IN THE ENTIRETY OF ITS CONSTRUCTION TO
CREATE A CONTINUOUS SYSTEM. INCLUDES PLACEMENT AND
SEALING OF PENETRATIONS, JUNCTION BOXES, ETC. UNLESS NOTED
OTHERWISE, PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE
AND ACCOMMODATE ITS PROFILE.
L. NEW DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING
UNLESS OTHERWISE NOTED: (A) ON THE PUSH SIDE OF DOORS:
PROVIDE A MINIMUM CLEARANCE OF 12" AT THE LOCK/LATCH SIDE
FACE OF DOOR FRAME OPENING TO ANY FIXED CONSTRUCTION
THAT WOULD BE ADJACENT TO THE FACE OF PARTITION. (B) ON THE
PULL SIDE OF DOORS: PROVIDE A MINIMUM CLEARANCE OF 18" AT
THE LOCK/LATCH SIDE FACE OF DOOR FRAME OPENING TO ANY
FIXED CONSTRUCTION THAT WOULD BE ADJACENT TO THE FACE OF
PARTITION. (C) IN METAL FRAMED GYPSUM BOARD PARTITIONS
TYPICALLY ON THE PULL SIDE OF DOORS WHERE THE HINGE SIDE OF
A DOOR FRAME IS PLACED ADJACENT TO ANY FIXED CONSTRUCTION,
LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
M. PROVIDE METAL BACKING PLATE AT ALL WALL MOUNTED ITEMS, SEE
EQUIPMENT PLANS AND SCHEDULES.
N. NEW SUBSURFACE FLOOR PREPARATION: THE EXISTING CONCRETE
FLOOR SUB-SURFACES RESULTING FROM THE REMOVAL OF OLD
FLOOR FINISHES (I.E., CERAMIC TILE, VCT, MASTICS, VINYL SHEETS,
ABATEMENTS, CARPETING, ETC.) OR GOING OVER CONCRETE FLOOR
REPAIRS OR INFILLS SHALL BE ENTIRELY SKIM COATED TO A
SMOOTH AND LEVEL FINISH, TO BE LEVEL WITH ALL ADJACENT
FLOOR SURFACES REQUIRING EXISTING FLOOR FINISH REMOVALS
AND/OR NEW FLOOR FINISHES, SUCH THAT THE FINAL FINISHED
FLOORS ARE SMOOTH AND LEVEL AND HAVE FINISH TRANSITIONS AS
SHOWN AND INTENDED. FOR BIDDING PURPOSES, FLOOR SKIM
COATING SHALL BE FIGURED AT 3/4” THICKNESS AVERAGE
O. FURRED PARTITIONS EXTEND TO STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
GENERAL NOTES FLOOR PLAN
EXISTING
CONSTRUCTION
TO REMAIN
NEW PARTITION
WALL
MATCHLINE
LIMITS OF NEW
CONSTRUCTION
FIRE
EXTINGUISHER
CABINET - REFER
TO DETAIL AE561
FLOOR PLAN LEGEND
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
BUILDING 217 KEY PLANN
08/20/2026
ARCHITECTURAL - ENLARGED PLAN -
DEMENTIA UNIT
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE407
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
N 1/8" = 1'-0"
ARCHITECTURAL - ENLARGED PLAN - DEMENTIA UNIT
Revisions: Date:
30% SCHEMATIC DESIGN 11/23/2023
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
P
P
P
E
DOOR AND FRAME TYPE ELEVATIONS
SE
E
DO
OR
S
CH
ED
UL
E
SEE DOOR SCHEDULE
FRAME TYPE F1
SE
E
DO
OR
S
CH
ED
UL
E
DOOR TYPE D1
SEE DOOR SCHEDULE
DOOR TYPE D2
SEE DOOR SCHEDULE
SE
E
DO
O
R
SC
HE
DU
LE
DOOR TYPE D3
SEE DOOR SCHEDULE
SE
E
DO
OR
S
CH
ED
UL
E
3' - 6" 1' - 6"EQ EQ
2" 2"2"
SE
E
DO
OR
S
CH
ED
UL
E
SEE DOOR SCHEDULE
FRAME TYPE F2
2" 2"2"
DOOR TYPE D4
10" 10"
SEE DOOR SCHEDULE
SE
E
DO
OR
S
CH
ED
UL
E
1'
- 0
2"
2"
FRAME TYPE F3
SE
E
DO
OR
S
CH
ED
UL
E
SEE DOOR SCHEDULE
5"
5" 5"
SE
E
DO
OR
S
CH
ED
UL
E
DOOR TYPE D5 DOOR TYPE D6
SE
E
DO
OR
S
CH
ED
UL
E
SEE DOOR SCHEDULE SEE DOOR SCHEDULE
1 15/16" 1 9/16"
/8
1/2" 1/2"
SEE PARTITION TYPE
VARIES
SEALANT AT BOTH
SIDES
HOLLOW METAL
FRAME
(2) 3 5/8" X 20 GA
STUDSVARIES
/1
/1
5/8"2"
/2
/2
S E
E P
A R
T
IT
IO
N
T Y
P E
V A
R
IE
S
FACE OF PERPENDICULAR
PARTITION
SEALANT AT BOTH SIDES
JAMB ANCHORS. (3)
ANCHORS PER JAMB
HOLLOW METAL
FRAME
RETURN FRAME. TYP.
DOUBLE STUDS BACK
TO BACK
V A
R
IE
S
18" MIN.
VARIES
SEALANT AT BOTH
SIDES
HM FRAME
(2) 4" X 20 GA
STUDS
SEE PARTITION
TYPE
REFER TO PLANS AND
DOOR SCHEDULE FOR
DOOR TYPE.
5 3/4"
2"
1/
4"
1/2" 1/2"
EQ 1 9/16" EQ
VA
RI
ES
SEALANT-BOTH
SIDES
MINIMUM (3) JAMB ANCHORS.
ATTACH JAMB TABS TO
DOUBLE STUDS, TYPICAL.
FLOOR
ANCHOR.
HM FRAME
(3) STUD CLIP ANCHORS
PER JAMB.
RETURN-LEG, TYP.
DOUBLE STUD, TYP.
S E
A
R T
IT
IO
N
T Y
P E
DOOR
EQ
9/
EQ
3/
4"
1/ 2"
1/ 2"
2"
3 1/4"
VARIES
SEE
PARTITION
TYPE
1/
2" 1/
8"
3/ 4"
3/ 8"
VA
RI
ES
S
A
R T
IT
IO
N
T Y
P E
3 1/2"
1/8"
1 3/4"
3/8"
1/
2"
3 9/16" 3 1/2"
1/8"
1 15/16" 1 15/16"
/8
CONTINUOUS BACKER
ROD AND CAULK AT EACH
SIDE.HM FRAME
GROUT FILL FRAME.
A
LI
G N
7 5/8"
NOTE:
• COORDINATE FRAME
DEPTH W/WALL
COMPONENT THICKNESS.
1" INCREMENT ON
STANDARD FRAM SIZES (4
3/4" - 8 3/4").
• COORDINATE DOOR AND
FRAME WITH COURSING OF
MASONRY OPENING.
GYPSUM WALL BOARD ON METAL
STUD FRAMING. SEE PARTITION
TYPE.
CORNER GUARD
STEEL LINTEL. REFER TO
LINTEL INFORMATION
SCHEDULE ON
STRUCTURAL SHEETS.
PAINT STEEL PLATE
TO MATCH DOOR
FRAME
FURRING TO
MATCH
ADJACANT SIDE
WHERE
APPLICABLE
/1
/1
5/8"2"
ALIG
N
NOTE:
• COORDINATE FRAME
DEPTH W/WALL
COMPONENT THICKNESS.
1" INCREMENT ON
STANDARD FRAM SIZES (4
3/4" - 8 3/4").
• COORDINATE DOOR AND
FRAME WITH COURSING OF
MASONRY OPENING.
CONTINUOUS BACKER ROD
AND SEALANT AT EACH
SIDE.
GROUT FILL FRAME.
HOLLOW METAL FRAME.
MASONRY ANCHOR.
GROUT FILL CMU CELL.
CMU WALL.
GYPSUM WALL BOARD ON METAL
STUD FRAMING. SEE PARTITION
TYPE.CORNER GUARD
FURRING TO MATCH
ADJACANT SIDE
WHERE APPLICABLE
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
REVIEW ONLY - NOT FOR CONSTRUCTION
Bancroft Project No. VA CONTRACT NO.
08/20/2026
ARCHITECTURAL - DOOR SCHEDULE AND
DETAILS
RENOVATIONS TO
BUILDING 217
EDWARD J. HINES JR. VAMC
CZ CR
578-26-016
AE601
100% CONSTRUCTION
DOCUMENTS
23-00936C25223C0071
DOOR SCHEDULE
DOOR FRAME
FIRE RATING
HARDWARE
SET NOTESMARK
SIZE
MATERIAL FINISH ELEVATION GLAZING MATERIAL ELEVATION
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
1-1 3' - 8" 7' - 0" 1 3/4" HM PAINT D1 HM F1 9/AE601 10/AE601 90 MIN HW-1A
1A43A 18' - 0" 8' - 6" 2 5/8" ALUM CLEAR ANODIZED SEE AE602 IG-1 ALUM 1/AE602 1/AE603 3/AE603 1/AE603 PER MANUF. SEE DETAILS ON AE602 & AE603
1A43NN 19' - 3 5/8" 8' - 6" 2 5/8" ALUM CLEAR ANODIZED SEE AE602 IG-1 ALUM 2/AE602 1/AE603 3/AE603 1/AE603 PER MANUF. SEE DETAILS ON AE602 & AE603
1A103 4' - 0" 7' - 0" 1 3/4" ALUM CLEAR ANODIZED D6 IG-1 ALUM 5/AE601 6/AE601 7/AE601 PER MANUF. BASIS OF DESIGN: KAWNEER 350
MEDIUM STILE
1A103B 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-SH-3
1A103C 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 HW-11
1A103D 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 HW-11
1A103E 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 HW-11
1A104A 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-4G
1A104B 3' - 0" 7' - 0" 1 3/4" ALUM CLEAR ANODIZED D5 IG-1 ALUM 5/AE601 6/AE601 7/AE601 PER MANUF. BASIS OF DESIGN: KAWNEER 350
MEDIUM STILE
1A104C 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-4G
1A104D 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WALNUT D1 HM F1 1/AE601 2/AE601 HW-R7
1A105 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-1L
1A106 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-1L
1A107 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-1L
1A108 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-1L
1A108A 6' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 45 MIN HW-11
1A108B 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 45 MIN HW-5F
1A108C 4' - 0" 7' - 0" 1 3/4" ALUM CLEAR ANODIZED D6 IG-1 ALUM 5/AE601 6/AE601 7/AE601 PER MANUF. BASIS OF DESIGN: KAWNEER 350
MEDIUM STILE
1A108D 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WALNUT D1 HM F1 1/AE601 2/AE601 45 MIN HW-5
1A109 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-1L
1A111 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-3E
1A112 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-2
1A118A 6' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 HW-R7
1A118B 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-6
1A118C 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-5
1A127AA 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R2C
1A141 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-3E
1A142 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-1L
1B80A 6' - 0" 7' - 0" 1 3/4" HM PAINT D2 HM F1 1/AE601 2/AE601 HW-SH-10A PROVIDE AUTOMATIC DOOR
OPERATOR
1B80B 6' - 0" 7' - 0" 1 3/4" HM PAINT D2 HM F1 1/AE601 2/AE601 HW-SH-10A PROVIDE AUTOMATIC DOOR
OPERATOR
1B135A 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-SH-3D
1B151 6' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 HW-SH-9
1B152 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-SH-3C
1B153 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-SH-3C
1B154 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B155 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B156 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B157 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B158 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B159 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B162 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B163 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B164 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B165 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B166 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B167 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B168 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B169 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B170 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B171 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B172 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B173 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B174 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B175 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B176 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D4 HM F1 1/AE601 2/AE601 HW-R1
1B177 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1B178A 4' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 45 MIN HW-5F
1B178B 3' - 4" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 45 MIN HW-5F
1B179 3' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-4B
1B180C 7' - 0" 8' - 0" 1 3/4" HM PAINT D2 HM F1 3/AE601 4/AE601 HW-SH-10
1C104 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F1 1/AE601 2/AE601 HW-R7A
1C105 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
1C178 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F1 1/AE601 2/AE601 HW-R7A
1C179 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
2A18A 6' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D2 HM F1 1/AE601 2/AE601 HW-R7
2C4 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F1 1/AE601 2/AE601 HW-R7A
2C5 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
2C78 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F1 1/AE601 2/AE601 HW-R7A
2C79 3' - 6" 7' - 0" 1 3/4" WD PINNACLE WLANUT D1 HM F1 1/AE601 2/AE601 HW-R3
B148 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F3 1/AE601 2/AE601 HW-R3
B149 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F1 1/AE601 2/AE601 HW-R7A
C148 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F3 1/AE601 2/AE601 HW-R3
C149 5' - 0" 7' - 0" 1 3/4" WD PINNACLE WLANUT D3 HM F1 1/AE601 2/AE601 HW-R7A
3" = 1'-0"
TYPICAL HEADER AT STUD WALL
3" = 1'-0"
TYPICAL JAMB AT STUD WALL
3" = 1'-0"
DOUBLE EGRESS HEADER
3" = 1'-0"
DOUBLE EGRESS JAMB
3" = 1'-0"5
STOREFRONT DOOR HEADER
3" = 1'-0"6
STOREFRONT DOOR JAMB
3" = 1'-0"7
STOREFRONT DOOR SILL
3" = 1'-0"8
STOREFRONT DOOR MEETING STILE
Revisions: Date:
60% DESIGN DEVELOPMENT 05/08/2024
90% CONSTRUCTION DOCUMENTS 08/23/2024
100% CONSTRUCTION DOCUMENTS 12/06/2024
100% CONSTRUCTION DOCUMENTS 06/10/2026
Addendum #2 08/20/2026
3" = 1'-0"9
TYPICAL HEADER AT CMU WALL W/ FURRING
3" = 1'-0"10
TYPICAL JAMB AT CMU WALL W/ FURRING
Edward Hines Jr. VA Medical Center
Hines, IL 60141
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-1
SECTION 08 71 00
DOOR HARDWARE
PART 1 - GENERAL
1.1 DESCRIPTION
Door hardware and related items necessary for complete installation and operation of doors.
1.2 RELATED WORK
Caulking: Section 07 92 00 JOINT SEALANTS.
Application of Hardware: Section 08 14 00, WOOD DOORS Section 08 11 13, HOLLOW METAL DOORS AND FRAMES Section 08 41 13, ALUMINUM-FRAMED
ENTRANCES AND STOREFRONTS Section 08 71 13, AUTOMATIC DOOR OPERATORS
Section 08 71 13.11, LOW ENERGY DOOR OPERATORS
Finishes: Section 09 06 00, SCHEDULE FOR FINISHES.
Painting: Section 09 91 00, PAINTING.
Card Readers: Section 28 13 00, PHYSICAL ACCESS CONTROL SYSTEMS.
Electrical: Division 26, ELECTRICAL.
Fire Detection: Section 28 31 00, FIRE DETECTION AND ALARM.
1.3 GENERAL
All hardware shall comply with ABAAS, (Architectural Barriers Act
Accessibility Standard) unless specified otherwise.
Provide rated door hardware assemblies where required by most current version of the International Building Code (IBC).
Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that it conforms to NFPA requirements.
Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.
The following items shall be of the same manufacturer, except as otherwise specified:
1. Mortise locksets.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-2
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
4. Exit devices.
5. Floor closers.
1.4 WARRANTY
Automatic door operators shall be subject to the terms of FAR Clause
52.246-21, except that the Warranty period shall be two years in lieu of one year for all items except as noted below:
1. Locks, latchsets, and panic hardware: 5 years.
2. Door closers and continuous hinges: 10 years.
1.5 MAINTENANCE MANUALS
In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled
"INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.
1.6 SUBMITTALS
Submittals shall be in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Submit 6 copies of the schedule per Section
01 33 23. Submit 2 final copies of the final approved schedules to VAMC
Locksmith as record copies (VISN Locksmith if the VAMC does not have a locksmith).
Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:
Hardware
Item
Quantity Size Reference
Publication
Type No.
Finish Mfr.
Name and
Catalog
No.
Key
Control
Symbols
UL Mark
(if fire rated and listed)
ANSI/BHMA
Finish
Designation
Samples and Manufacturers' Literature:
1. Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers
Association shall be submitted for approval. Tag and mark all items with manufacturer's name, catalog number and project number.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-3
2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.
Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates shall be accompanied by copies of reports as referenced. The testing shall have been conducted either in the manufacturer's plant and certified by an independent testing laboratory or conducted in an independent laboratory, within four years of submittal of reports for approval.
1.7 DELIVERY AND MARKING
Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to
COR for reference purposes. Tag shall identify items by Project
Specification number and manufacturer's catalog number. These items shall remain on file in COR's office until all other similar items have been installed in project, at which time the COR will deliver items on file to Contractor for installation in predetermined locations on the project.
1.8 PREINSTALLATION MEETING
Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contractor and Installer, Architect, Project Engineer and VA Locksmith, Hardware Consultant, and
Hardware Manufacturer’s Representative. Review the following:
1. Inspection of door hardware.
2. Job and surface readiness.
3. Coordination with other work.
4. Protection of hardware surfaces.
5. Substrate surface protection.
6. Installation.
7. Adjusting.
8. Repair.
9. Field quality control.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-4
10. Cleaning.
1.9 INSTRUCTIONS
Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols. Symbols for hardware sets consist of letters (e.g., "HW") followed by a number.
Each number designates a set of hardware items applicable to a door type.
Keying: All cylinders shall be keyed into existing Grand Master Key
System. Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset. Cylinders shall be 7 pin type. Keying information shall be furnished at a later date by the COR.
1.10 APPLICABLE PUBLICATIONS
The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.
ASTM International(ASTM):
F883-13.................Padlocks
E2180-18................Standard Test Method for Determining the
Activity of Incorporated Antimicrobial Agent(s)
In Polymeric or Hydrophobic Materials
American National Standards Institute/Builders Hardware Manufacturers
Association (ANSI/BHMA):
A156.1-06...............Butts and Hinges
A156.2-03...............Bored and Pre-assembled Locks and Latches
A156.3-08...............Exit Devices, Coordinators, and Auto Flush Bolts
A156.4-08...............Door Controls (Closers)
A156.5-14...............Cylinders and Input Devices for Locks.
A156.6-05...............Architectural Door Trim
A156.8-05...............Door Controls-Overhead Stops and Holders
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-5
A156.11-14..............Cabinet Locks
A156.12-05 .............Interconnected Locks and Latches
A156.13-05..............Mortise Locks and Latches Series 1000
A156.14-07 .............Sliding and Folding Door Hardware
A156.15-06..............Release Devices-Closer Holder, Electromagnetic and Electromechanical
A156.16-08..............Auxiliary Hardware
A156.17-04 .............Self-Closing Hinges and Pivots
A156.18-06..............Materials and Finishes
A156.20-06 .............Strap and Tee Hinges, and Hasps
A156.21-09..............Thresholds
A156.22-05..............Door Gasketing and Edge Seal Systems
A156.23-04..............Electromagnetic Locks
A156.24-03..............Delayed Egress Locking Systems
A156.25-07 .............Electrified Locking Devices
A156.26-06..............Continuous Hinges
A156.28-07 .............Master Keying Systems
A156.29-07 .............Exit Locks and Alarms
A156.30-03 .............High Security Cylinders
A156.31-07 .............Electric Strikes and Frame Mounted Actuators
A156.36-10..............Auxiliary Locks
A250.8-03...............Standard Steel Doors and Frames
National Fire Protection Association (NFPA):
80-10...................Fire Doors and Other Opening Protectives
101-09..................Life Safety Code
Underwriters Laboratories, Inc. (UL):
Building Materials Directory (2008)
Architectural Barriers Act Accessibility Standards (ABAAS)
PART 2 - PRODUCTS
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-6
2.1 BUTT HINGES
ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). The following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:
1. Exterior Doors: Type A2112/A5112 for doors 900 mm (3 feet) wide or less and Type A2111/A5111 for doors over 900 mm (3 feet) wide. Hinges for exterior outswing doors shall have non-removable pins. Hinges for exterior fire-rated doors shall be of stainless steel material.
2. Interior Doors: Type A8112/A5112 for doors 900 mm (3 feet) wide or less and Type A8111/A5111 for doors over 900 mm (3 feet) wide.
Hinges for doors exposed to high humidity areas (shower rooms, toilet rooms, kitchens, janitor rooms, etc. shall be of stainless steel material.
Provide quantity and size of hinges per door leaf as follows:
1. Doors up to 1210 mm (4 feet) high: 2 hinges.
2. Doors 1210 mm (4 feet) to 2260 mm (7 feet 5 inches) high: 3 hinges minimum.
3. Doors greater than 2260 mm (7 feet 5 inches) high: 4 hinges.
4. Doors up to 900 mm (3 feet) wide, standard weight: 114 mm x 114 mm
(4-1/2 inches x 4-1/2 inches) hinges.
5. Doors over 900 mm (3 feet) to 1065 mm (3 feet 6 inches) wide, standard weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
6. Doors over 1065 mm (3 feet 6 inches) to 1210 mm (4 feet), heavy weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
7. Provide heavy-weight hinges where specified.
8. At doors weighing 330 kg (150 pounds) or more, furnish 127 mm (5 inch) high hinges.
See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above and continuous hinges specified below.
2.2 CONTINUOUS HINGES
ANSI/BHMA A156.26, Grade 1-600.
1. Listed under Category N in BHMA's "Certified Product Directory."
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-7
General: Minimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width of 4 inches (102 mm); fabricated to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete
Continuous, Barrel-Type Hinges: Hinge with knuckles formed around a
Teflon-coated 6.35mm (0.25-inch) minimum diameter pin that extends entire length of hinge.
1. Base Metal for Exterior Hinges: Stainless steel.
2. Base Metal for Interior Hinges: Stainless steel.
3. Base Metal for Hinges for Fire-Rated Assemblies: Stainless steel.
4. Provide with non-removable pin (hospital tip option) at lockable outswing doors.
5. Where required to clear adjacent casing, trim, and wall conditions and allow full door swing, provide wide throw hinges of minimum width required.
6. Provide with manufacturer’s cut-outs for separate mortised power transfers and/or mortised automatic door bottoms where they occur.
7. Where thru-wire power transfers are integral to the hinge, provide hinge with easily removable portion to allow easy access to wiring connections.
8. Where models are specified that provide an integral wrap-around edge guard for the hinge edge of the door, provide manufacturer’s adjustable threaded stud and machine screw mechanism to allow the door to be adjusted within the wrap-around edge guard.
2.3 DOOR CLOSING DEVICES
Closing devices shall be products of one manufacturer for each type specified.
2.4 OVERHEAD CLOSERS
Conform to ANSI A156.4, Grade 1.
Closers shall conform to the following:
1. The closer shall have minimum 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.
2. Where specified, closer shall have hold-open feature.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-8
3. Size Requirements: Provide multi-size closers, sizes 1 through 6, except where multi-size closer is not available for the required application.
4. Material of closer body shall be forged or cast.
5. Arm and brackets for closers shall be steel, malleable iron or high strength ductile cast iron.
6. Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless steel material.
7. Closers shall have full size metal cover; plastic covers will not be accepted.
8. Closers shall have adjustable hydraulic back-check, separate valves for closing and latching speed, adjustable back-check positioning valve, and adjustable delayed action valve.
9. Provide closers with any accessories required for the mounting application, including (but not limited to) drop plates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bull-nose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provide special arms, drop plates, and templating as needed to allow mounting at doors with overhead stops and/or holders.
10. Closer arms or backcheck valve shall not be used to stop the door from overswing, except in applications where a separate wall, floor, or overhead stop cannot be used.
11. Provide parallel arm closers with heavy duty rigid arm.
12. Where closers are to be installed on the push side of the door, provide parallel arm type except where conditions require use of top jamb arm.
13. Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.
14. All closers shall have a 1 ½” (38mm) minimum piston diameter.
2.5 FLOOR CLOSERS AND FLOOR PIVOT SETS
Comply with ANSI A156.4. Provide stainless steel floor plates for floor closers and floor pivots, except where metal thresholds occur. Provide cement case for all floor closers. Floor closers specified for fire doors shall comply with Underwriters Laboratories, Inc., requirements
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-9 for concealed type floor closers for classes of fire doors indicated on drawings. Hold-open mechanism, where required, shall engage when door is opened 105 degrees, except when door swing is limited by building construction or equipment, the hold-open feature shall engage when door is opened approximately 90 degrees. The hold-open mechanism shall be selectable on/off by turning a screw through the floor plate. Floor closers shall have adjustable hydraulic back-check, adjustable close speed, and adjustable latch speed. Provide closers with delayed action where a hold-open mechanism is not required. Floor closers shall be multi-sized. Single acting floor closers shall also have built in dead stop. Where required, provide closers with special cement cases appropriate for shallow deck installation or where concrete joint lines run through the floor blockout. At offset-hung doors installed in deep reveals, provide special closer arm and spindle to allow for installation. Where stone or terrazzo is applied over the floor closer case, provide closer without floor plate and with extended spindle
(length as required) and special cover pan (depth as required) to allow closer to be accessed without damaging the material applied over the closer. Pivots for non-labeled doors shall be cast, forged or extruded brass or bronze.
Where floor closer appears in hardware set provide the following as applicable.
1. Double Acting Floor Closers: Type C06012.
2. Single Acting Floor Closer: Type C06021 (center pivoted).
(Intermediate pivot is not required).
3. Single Acting Floor Closers: Type C06041 (offset pivoted).
4. Single Acting Floor Closer for Labeled Fire Doors: Type C06051
(offset pivoted).
5. Single Acting Floor Closers For Lead Lined Doors: Type C06071 (offset pivoted).
2.6 DOOR STOPS
Conform to ANSI A156.16.
Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use expansion shields for mounting door stops.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-10
Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.
Provide floor stops (Type L02141 or L02161) in office areas; Type L02121 x 3 screws into floor elsewhere. Wall bumpers, where used, must be installed to impact the trim or the door within the leading half of its width. Floor stops, where used, must be installed within 4-inches of the wall face and impact the door within the leading half of its width.
Where drywall partitions occur, use floor stops, Type L02141 or L02161 in office areas, Type L02121 elsewhere.
Provide stop Type L02011, as applicable for exterior doors. At outswing doors where stop can be installed in concrete, provide stop mated to concrete anchor set in 76mm (3-inch) core-drilled hole and filled with quick-setting cement.
Omit stops where floor mounted door holders are required and where automatic operated doors occur.
Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.
Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.
Provide overhead surface applied stop Type C02541, ANSI A156.8 on patient toilet doors in bedrooms where toilet door could come in contact with the bedroom door.
Provide door stops on doors where combination closer magnetic holders are specified, except where wall stops cannot be used or where floor stops cannot be installed within 4-inches of the wall.
Where the specified wall or floor stop cannot be used, provide concealed overhead stops (surface-mounted where concealed cannot be used).
2.7 OVERHEAD DOOR STOPS AND HOLDERS
Conform to ANSI Standard A156.8. Overhead holders shall be of sizes recommended by holder manufacturer for each width of door. Set overhead holders for 110 degree opening, unless limited by building construction or equipment. Provide Grade 1 overhead concealed slide type: stop-only at rated doors and security doors, hold-open type with exposed hold-open on/off control at all other doors requiring overhead door stops.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-11
2.8 FLOOR DOOR HOLDERS
Conform to ANSI Standard A156.16. Provide extension strikes for Types
L01301 and L01311 holders where necessary.
2.9 LOCKS AND LATCHES
Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylinders shall have not less than seven pins. Cylinders for all locksets shall be removable core type. Cylinders shall be furnished with construction removable cores and construction master keys. Cylinder shall be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand Master Key System.
Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with 19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label. Provide temporary keying device or construction core to allow opening and closing during construction and prior to the installation of final cores.
In addition to above requirements, locks and latches shall comply with following requirements:
1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be per Hines VA Lock Hardware Standards. All locksets and latchsets, except on designated doors in Psychiatric (Mental
Health) areas, shall have lever handles fabricated from cast stainless steel. Provide sectional (lever x rose) lever design matching [__________]. No substitute lever material shall be accepted. All locks and latchsets shall be furnished with 122.55 mm
(4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function F02 shall be furnished with emergency tools/keys for emergency entrance. All lock cases installed on lead lined doors shall be lead lined before applying final hardware finish. Furnish armored fronts for all mortise locks.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-12
Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.
2. Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets shall be per Hines VA Lock Hardware Standards. All locks and latchsets shall be furnished with 122.55 mm (4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Provide lever design to match design selected by Architect or to match existing lever design. Where two turn pieces are specified for lock
F76, turn piece on inside knob shall lock and unlock inside knob, and turn piece on outside knob shall unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)
3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.36.
2.10 PUSH-BUTTON COMBINATION LOCKS
ANSI/BHMA A156.5, Grade 1. Battery operated pushbutton entry.
Construction: Heavy duty mortise lock housing conforming to ANSI/BHMA
A156.13, Grade 1. Lever handles and operating components in compliance with the ABAAS and the ADA Accessibility Guidelines. Match lever handles of locks and latchsets on adjacent doors.
Special Features: Key override to permit a master keyed security system and a pushbutton security code activated passage feature to allow access without using the entry code.
2.11 ELECTROMAGNETIC LOCKS
ANSI/BHMA A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product
Directory."
1. Type: Full exterior or full interior, as required by application indicated.
2. Strength Ranking: 1500 pound force (6672 N.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-13
3. Inductive Kickback Peak Voltage: Not more than 0 V.
4. Residual Magnetism: Not more than 4 pound force (18 N to separate door from magnet.
Delayed-Egress Locks: BHMA A156.24.
1. Means of Egress Doors: Lock releases within 15 seconds after applying a force not more than 15 pound force (67 N) for not more than 3 seconds, as required by NFPA 101.
2. Security Grade: Activated from secure side of door by initiating device.
3. Movement Grade: Activated by door movement as initiating device.
4. The lock housing shall not project more than 4-inches (101mm) from the underside of the frame head stop.
2.12 ELECTRIC STRIKES
ANSI/ BHMA A156.31 Grade 1.
General: Use fail-secure electric strikes at fire-rated doors.
2.13 KEYS
Stamp all keys with change number and key set symbol. Furnish keys in quantities as follows:
Locks/Keys Quantity
Cylinder locks 2 keys each
Cylinder lock change key blanks
100 each different key way
Master-keyed sets 6 keys each
Grand Master sets 6 keys each
Great Grand Master set 5 keys
Control key 2 keys
Psychiatric keys shall be cut so that first two bittings closest to the key shoulder are shallow to provide greater strength at point of greatest torque.
2.14 KEY CABINET
2.15 ARMOR PLATES, KICK PLATES, MOP PLATES AND DOOR EDGING
Conform to ANSI Standard A156.6.
Provide protective plates and door edging as specified below:
1. Kick plates, mop plates and armor plates of metal, Type J100 series.
Renovations to Building 217
Bancroft Architects + Engineers
01-01-24
Contract No. 36C25223C0071
Station Project No. 578-26-016
Bancroft-AE Project No. 23-009 06/10/2026
08 71 00-14
2. Provide kick plates and mop plates where specified. Kick plates shall be 254 mm (10 inches) or 305 mm (12 inches) high. Mop plates shall be
152 mm (6 inches) high. Both kick and mop plates shall be minimum
1.27 mm (0.050 inches) thick. Provide kick and mop plates beveled on all 4 edges (B4E). On push side of doors where jamb stop extends to floor, make kick plates 38 mm (1-1/2 inches) less than width of door, except pairs of metal doors which shall have plates 25 mm (1 inch) less than width of each door. Extend all other kick and mop plates to within 6 mm (1/4 inch) of each edge of doors. Kick and mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.
3. Kick plates and/or mop plates are not required on following door sides:
a. Armor plate side of doors;
b. Exterior side of exterior doors;
c. Closet side of closet doors;
d. Both sides of aluminum entrance doors.
4. Armor plates for doors are listed under Article "Hardware Sets".
Armor plates shall be thickness as noted in the hardware set, 875 mm
(35 inches) high and 38 mm (1-1/2 inches) less than width of doors, except on pairs of metal doors. Provide armor plates beveled on all 4 edges (B4E). Plates on pairs of metal doors shall be 25 mm (1 inch) less than width of each door. Where top of intermediate rail of door is less than 875 mm (35 inches) from door bottom, extend armor plates to within 13 mm (1/2 inch) of top of intermediate rail. On doors equipped with panic devices, extend armor plates to within 13 mm (1/2 inch) of panic bolt push bar.
5. Where louver or grille occurs in lower portion of doors, substitute stretcher plate and kick plate in…