VA WCHCS Bldg 34 Oneline Report 23.pdf

PDF 49 KB Posted

Attached to
H263--Fire Protection Services Federal contract opportunity
Solicitation number
36C25925Q0190
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

About this file

This is a fire protection device inspection report from March 2023 for Building 34 at a VA Hospital (WCHCS), conducted by ALARMSpecialists, Inc. The report documents required testing of fire safety devices in accordance with multiple EC.02.03.05 standards.

The inspection covered various fire protection devices including: a pull station at the main entry, seven smoke detectors in different locations (computer room ceiling/floor, FACP room, main entry, and hallway), two tamper switches (server room and PIV valve), and one speaker/strobe device. All devices were tested on March 21, 2023, and passed inspection. The report indicates specific device locations, node/loop/device numbers, and notable comments such as "2 Turns. Locate Icon to outside computer rm 105 on Onyx" for the server room tamper switch. The testing appears to fulfill Joint Commission requirements for 6-month and 12-month testing cycles of different fire protection system components.

View the file

Other files for this federal contract opportunity

Other files attached to H263--Fire Protection Services, newest first.
File Type Posted
VA WCHCS Bldg 45 Oneline Report 23.pdf PDF
VA WCHCS Bldg 33 Oneline Report 23.pdf PDF
VA WCHCS Bldg 20 Oneline Report 23.pdf PDF
VA WCHCS Bldg 14 Oneline Report 23.pdf PDF
VA WCHCS Bldg 7 Oneline Report 23.pdf PDF
VA WCHCS Bldg 6 Oneline Report 23.pdf PDF
VA WCHCS Off-Premises Monitoring EP5 Report 23.pdf PDF
VA WCHCS Bldg 12 Oneline Report 23.pdf PDF
VA WCHCS Bldg 9 Oneline Report 23.pdf PDF
VA WCHCS Bldg 8 Oneline Report 23.pdf PDF
36C25925Q0190 0002_1.docx DOCX document
VA WCHCS Bldg 37 Oneline Report 23.pdf PDF
VA WCHCS Bldg 13 Oneline Report 23.pdf PDF
36C25925Q0190 0002.docx DOCX document
VA WCHCS Device List 23.pdf PDF
VA WCHCS Bldg 46 Oneline Report 23.pdf PDF
VA WCHCS Bldg 36 Oneline Report 23.pdf PDF
VA WCHCS Bldg 35 Oneline Report 23.pdf PDF
VA WCHCS Bldg 22 Oneline Report 23.pdf PDF
VA WCHCS Bldg 5 Oneline Report 23.pdf PDF
VA WCHCS Bldg 1 Oneline Report 23.pdf PDF
36C25925Q0190 0001_1.docx DOCX document
36C25925Q0190 0001.docx DOCX document
Previous Solicitation Questions and Answers.docx DOCX document
Table 1 Task list by TJC EPs and Frequency 112624.xlsx XLSX spreadsheet
36C25925Q0190_1.docx DOCX document
36C25925Q0190.docx DOCX document
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Prepared by ALARMSpecialists, Inc

6786 S Revere Pkwy Suite 110 Centennial CO 80112 Phone: 303 986-5900 Fax: 866 974-9299 Page 1 of 4

Date Tested Device Location No de Lo op Device Status Comments March 21, 2023 Pull Station MAIN ENTRY BLD 34 FLR 1 N 1 L 1 M 1 Pass

VA Hospital - WCHCS - Bldg 34 - Device List - March 23 EC.02.03.05 EP 3 Every 12 months, the hospital tests duct detectors, heat detectors, manual fire alarm boxes, and smoke detectors on the inventory. The results and completion dates are documented.

6786 S Revere Pkwy Suite 110 Centennial CO 80112 Phone: 303 986-5900 Fax: 866 974-9299 Page 2 of 4

Date Tested Device Location No de Lo op Device Status Comments March 21, 2023 Smoke Detector COMPUTER RM CEILING BLD 34 FLR 1 N 1 L 1 D 3 Pass March 21, 2023 Smoke Detector COMPUTER RM CEILING BLD 34 FLR 1 N 1 L 1 D 4 Pass March 21, 2023 Smoke Detector COMPUTER RM FLOOR BLD 34 FLR 1 N 1 L 1 D 5 Pass March 21, 2023 Smoke Detector COMPUTER RM FLOOR BLD 34 FLR 1 N 1 L 1 D 6 Pass March 21, 2023 Smoke Detector ABOVE FACP RM 103 BLD 34 FLR 1 N 1 L 1 D 10 Pass March 21, 2023 Smoke Detector MAIN ENTRY BLD 34 FLR 1 N 1 L 1 D 11 Pass March 21, 2023 Smoke Detector HALL BY OFFICE 101 BLD 34 FLR 1 N 1 L 1 D 2 pass

EC.02.03.05 EP 3 Every 12 months, the hospital tests duct detectors, heat detectors, manual fire alarm boxes, and smoke detectors on the inventory. The results and completion dates are documented.

VA Hospital - WCHCS - Bldg 34 - Device List - March 23

6786 S Revere Pkwy Suite 110 Centennial CO 80112 Phone: 303 986-5900 Fax: 866 974-9299 Page 3 of 4

Date Tested DEVICE LOCATION STATUS COMMENTS March 21, 2023 Tamper Switch TAMPER BLD 34 SERVER RM FLR 1 N 1 L 1 M 5 Pass 2 Turns. Locate Icon to outside computer rm 105 on Onyx March 21, 2023 Tamper Switch PIV VALVE BY BLDG 34 N 1 L 1 M 30 Pass 3 Turns

VA WCHCS - Bldg 34 - Sprinkler - March 23 EC.02.03.05 EP 2 Every 6 months, the hospital tests vane-type and pressure-type water flow devices and valve tamper switches on the inventory. The results and completion dates are documented.

Note: Mechanical water-flow devices (including, but not limited to, water motor gongs) should be tested quarterly. The results and completion dates are documented.

6786 S Revere Pkwy Suite 110 Centennial CO 80112 Phone: 303 986-5900 Fax: 866 974-9299 Page 4 of 4

Date Tested Device Room # / Corridor Location / DescriptionNo de Lo op Device Label Status Comments March 21, 2023 Speaker/Strobe By Rm B34-4 Bldg 34 N 1 L 1 x x 49798385 Pass

VA WCHCS - Bldg 34 - Audibles - Device List - March 23

EC.02.03.05 EP 4 Every 12 months, the hospital tests visual and audible fire alarms, including speakers and door-releasing devices on the inventory. The results and completion dates are documented.

File details come from the government source that posted it. Updated .