EL4.3+Add+1.pdf
PDF 129 KB Posted
- Attached to
- Y1DA--552-CSI-162: Site Prep for PET CT Federal contract opportunity
- Solicitation number
- 36C25021B0001
About this file
This notice is for a solicitation seeking a service-disabled veteran-owned small business to complete site preparation for a PET/CT replacement project at the Dayton VA Medical Center in Dayton, Ohio. The contractor shall demolish existing structures and prepare the site for building operations. The work must be completed within 245 calendar days of receiving the notice to proceed.
The solicitation will be posted on November 9, 2020 on SAM.gov, with proposals due approximately 30 days later. The project value is between $1,000,000 and $5,000,000 under NAICS code 236220 with a small business size standard of $39.5 million. The contractor must perform a minimum of 25% of the construction work. Bid, payment and performance bonds will be required. A site visit will be scheduled, and amendments will be posted on SAM.gov. Questions should be emailed to the point of contact by the deadline stated.
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IDENTIFICATION TAGGING DETAILS
N.T.S.
LINE #1
LINE #2
LINE #3
(TYPICAL FOR ALL NAMEPLATES)
GENERAL NAMEPLATE DETAIL
(REFER TO SPECIFICATIONS)
SOURCE CIRCUIT NUMBER
DISCONNECT SWITCH/MOTOR
STARTER NAMEPLATE
LINE #1
LINE #2
LINE #3
EQUIPMENT DESIGNATION
EQUIPMENT SOURCE
BRANCH OVERCURRENT PROTECTIVE
DEVICE OR STARTER NAMEPLATE
EQUIPMENT DESIGNATION
DEVICE NUMBER
LINE #3
LINE #1
LINE #2
STANDARD COLORS:
ELECTRICAL EQUIPMENT SUCH AS:
1. PANELBOARDS, MOTOR STARTERS, MOTOR CONTROL CENTERS, DISTRIBUTION PANELS,
SWITCHBOARDS, DISCONNECT SWITCHES (IF APPLICABLE)
A. 208Y/120 VOLTS (NORMAL) - GREEN BACKGROUND, WHITE LETTERS
B. 480Y/277 VOLTS (NORMAL) - BLACK BACKGROUND, WHITE LETTERS
C. 208Y/120 VOLTS (EMERGENCY) - WHITE BACKGROUND, RED LETTERS
D. 480Y/277 VOLTS (EMERGENCY) - RED BACKGROUND, WHITE LETTERS
NAMEPLATE COLOR CODING AND VERBIAGE SHALL BE REVIEWED IN DETAIL WITH THE OWNER
PRIOR TO FABRICATION.
SELF-TAPPING SCREW. (TYP.)
ENGRAVED MICARTA WITH 3/8" HIGH LETTERS. REFER
TO COLOR CHART FOR LETTER AND BACKGROUND
COLORS. INSTALL CENTERED, AT TOP OF FRONT FACE
FOR ALL BRANCH PANELBOARDS, SWITCHBOARDS,
DISTRIBUTION PANELS, MCC'S, TRANSFORMERS,
SAFETY AND DISCONNECT SWITCHES, AND MOTOR
STARTERS. INSTALL ADJACENT TO ASSOCIATED
BRANCH DEVICE FOR SWITCHBOARD AND
DISTRIBUTION PANELS.
3" (TYP.)
MINIMUM
2" (T
YP
M
IN
IM
U
M
NR6F-1
NR6F-1
VERTICALLY MOUNTED
HORIZONTALLY MOUNTED
N.T.S.
TYPICAL DUPLEX RECEPTACLE FACEPLATE
NOTES:
1. EMERGENCY : RED LETTERS ON STAINLESS
FACEPLATE. PROVIDE RED FACEPLATE WITH WHITE
LETTERS FOR NON-METAL EMERGENCY RECEPTACLES.
2. NORMAL: IVORY/WHITE FACEPLATE WITH BLACK
LETTERS.
3. VERTICALLY MOUNTED RECEPTACLE DETAILS ARE
TYPICAL FOR HORIZONTALLY MOUNTED RECEPTACLE.
CIRCUIT NUMBER
PANEL (SOURCE)
STAINLESS STEEL FACEPLATE
OR AS SPECIFIED BY
OWNER/ARCHITECT.
1/2"H x 1-1/2"W WITH 1/4" ENGRAVED
LETTERING. PROVIDE ENAMIL FILL
ENGRAVED PLASTIC FACEPLATE.
N.T.S.
WALL SECTION
FLOOR SECTION
NOTES:
1. WHERE CONDUIT, CABLES AND OTHER COMPONENTS PASS THROUGH FIRE OR
SMOKE RATED WALLS OR FLOORS, PROVIDE NON-ASBESTOS SEAL ASSEMBLIES
CLASSIFIED BY U.L. TO PROVIDE FIRE BARRIERS EQUAL TO OR GREATER THAN THE
TIME RATING OF THE CONSTRUCTION BEING PENETRATED, WITH APPROPRIATE
MATERIALS AND SYSTEMS THAT COMPLY WITH APPLICABLE CODES AND THAT
HAVE BEEN TESTED IN ACCORDANCE WITH U.L. 1479 OR ASTM E814.
2. GROUT, MORTAR OR GYPSUM BASED PRODUCTS SHALL NOT BE INSTALLED IN
LIEU OF FIRESTOPPING MATERIALS AND U.L. SYSTEMS.
3. FOR SLEEVED PENETRATIONS, FIRESTOP ANNULAR SPACE, IF ANY, BETWEEN
SLEEVE AND ADJACENT CONSTRUCTION TO MEET U.L. SYSTEM REQUIREMENTS.
SEE NOTE 2 ABOVE.
4. THIS CONTRACTOR SHALL FIRESTOP ALL MISCELLANEOUS OPENINGS IN FIRE-
RATED CONSTRUCTION RESULTING FROM HIS WORK.
5. CONTRACTOR SHALL PROVIDE SUBMITTAL DRAWINGS TO ENGINEER, INCLUDING
U.L. RATED SYSTEM NUMBER AND DETAIL FOR EACH TYPE OF PENETRATION AND
CONFIGURATION.
6. SLEEVES USED FOR CABLE RISERS THROUGH FLOORS OR WALLS SHALL BE
INSTALLED PER THE ABOVE FLOOR OR WALL SECTIONS. IN ADDITION, FIRESTOP
MATERIAL SHALL BE PROVIDED INSIDE SLEEVE AFTER CABLES ARE COMPLETELY
INSTALLED.
FIRESTOPPING DETAIL FOR PENETRATIONS
THROUGH FIRE-RATED CONSTRUCTIONS
BUS DUCT WL6001 CAJ6008 CAJ6008
CABLE TRAYS WL4005 WJ4009 CAJ4029
CABLES
(MAX. 3" DIA. CABLE BUNDLE)
WL3076 WJ3022 CAJ3133
PVC CONDUIT/ INNER DUCT
(< 2" DIA.) WL2093 WJ2018 CAJ2031
EMT CONDUIT
(NOMINAL < 4" DIA.) WL1049 WS1055 CAJ1079
CAJ1079
UL FIRE STOP SYSTEMS FOR 1 AND 2 HOUR RATED WALL
AND FLOOR ASSEMBLIES
WS1055WL1049
SERVICE
GRC CONDUIT
(NOMINAL < 6" DIA.)
CONCRETE FLOOR
PENETRATION
CONCRETE/MASONRY
WALL PENETRATION
GYPSUM WALL
PENETRATION
PIPE SLEEVE (SLEEVE TO EXTEND
2" ABOVE FLOOR IN MECHANICAL
EQUIPMENT ROOMS.)
FURNISH AND INSTALL FIRESTOP
MATERIALS IN ACCORDANCE WITH
APPROPRIATE U.L. SYSTEMS TO
MAINTAIN FIRE RESISTANCE RATING
SEAL JOINT BETWEEN SLEEVE AND
FLOOR SLAB WITH MIN. 1/2" BEAD
FIRESTOP CAULK
SEE ARCHITECTURAL DRAWINGS
FOR WALL CONSTRUCTION AND
FIRE RATING
PENETRATING CONDUIT, ETC.
PENETRATING CONDUIT, ETC.
FLOOR SLAB; SEE
ARCHITECTURAL DRAWINGS
FOR FLOOR CONSTRUCTION
AND FIRE RATING
DAMMING MATERIAL
(PER U.L. TESTED SYSTEM DESIGN)
PIPE SLEEVE
FURNISH AND INSTALL FIRESTOP
MATERIALS IN ACCORDANCE WITH
APPROPRIATE U.L. SYSTEMS
TO MAINTAIN FIRE RESISTANCE
RATING
N.T.S.
ELECTRONIC SINK/TOILET WIRING DETAIL
TYPICAL PATIENT TOILET ROOM (SYMBOL " ")
NOTES:
1. MODULAR CONNECTION BOX AND
TRANSFORMER MAY BE PROVIDED WITH
120V SUPPLY BOX.
2. INTERCONNECTION, MOUNTING
HEIGHTS, ETC. TO COORDINATE ON SITE
WITH RESPECTIVE SUBCONTRACTOR.
120V BRANCH CCT. BY E.C. SEE
FLOOR PLAN FOR CCT. NUMBER.
2/C #18 SHIELDED
CABLE, 1/2"C
CONCEALED IN WALL
2/C #18 CABLE
BY E.C.
FLOOR
REMOTE TRANSFORMER. FURNISHED
BY PC/SINK MANUFACTURER. MOUNTED
ABOVE ACCESSIBLE CEILING IN
SURFACE J-BOX AND WIRED BY E.C. SEE
NOTE.
WIRE BOX MOUNTED IN
WALL BEHIND TOILET
TOILET
SOLENOID AND SENSOR
WIRE BOX MOUNTED IN
WALL BEHIND LAVATORY
SOLENOID (BY OTHERS)
ELECTRONIC
SENSOR
BY OTHERS
GOOSENECK FAUCET
ES-1
4-#16
FIRE ALARM WIRING DIAGRAM
N.T.S.
EXISTING
EST3
FACP
FIRE ALARM CABLE LEGEND
2-#16
CCT. "P"
CCT. "P"CCT. "P"
OR
CCT. "D" CCT. "D"
CCT. "P"
OR
CCT. "S"
CCT. "D"
TO DESIGNATED EQUIPMENT ON FLOOR PLANS FOR
MONITORING AND/OR CONTROLLING. VERIFY
TERMINATION POINTS ON EQUIPMENT WITH
MANUFACTURER.
FIRE ALARM GENERAL NOTES:
1. THE ENTIRE FIRE ALARM SYSTEM INSTALLATION SHALL BE A CLASS B SYSTEM AS DEFINED IN NFPA 72. REFER TO SPECIFICATIONS FOR ADDITIONAL SYSTEM REQUIREMENTS, AND COMPONENT
DESCRIPTIONS.
2. COMPLETE FIRE ALARM SYSTEM CONDUIT AND WIRING SHALL BE INSTALLED PER SUPPLIERS SHOP DRAWINGS. VERIFY CONDUIT AND WIRING REQUIREMENTS WITH SUPPLIER PRIOR TO BID.
3. SEE FLOOR PLAN DRAWINGS FOR FIRE ALARM SYSTEM DEVICE QUANTITIES AND LOCATION.
4. ALL FIRE ALARM WIRING SHALL BE IN 3/4" (MINIMUM) CONDUIT UNLESS OTHERWISE NOTED.
5. PROVIDE REQUIRED QUANTITY OF MONITOR MODULES TO PICK UP EXISTING INITIATING ZONES
ON EXISTING FACP. PROVIDE REQUIRED QUANTITY OF CONTROL MODULES TO TRIP EXISTING
SYSTEM INDICATING DEVICES IF NEW SYSTEM INITIATING DEVICES GO INTO ALARM.
6. PROVIDE TEMPORARY PROGRAMMING OF FIRE ALARM SYSTEMS DURING CONSTRUCTION
PHASE AS REQUIRED TO MAINTAIN EXISTING OPERATION. VERIFY BATTERY CALCULATIONS FOR
ADDITION OF DEVICES TO EXISTING SYSTEM.
7. NO CHANGES WILL BE MADE TO THE SYSTEM RESPONSE. NEW NOTIFICATION APPLIANCES WILL
BE AN EXTENSION OF EXISTING CIRCUITS OR RESPOND WITH THE EXISTING DEVICES IN THE
SMOKE COMPARTMENT.
D - DATA - 2/C #18 TWISTED SHIELDED PAIR (WEST PENN #975)
P - POWER - 2/C #14 (WEST PENN #972)
S - SIGNAL - 2/C #14 (WESTE PENN #972)
R - REMOTE - 2/C #18 TWISTED SHIELDED PAIR AND 2/C #14
(WEST PENN #975 AND #972 RESPECTIVELY)
REMOTE
INDICATOR LIGHT
AND TEST SWITCH
END OF LINE
DEVICE (TYP.)
TO REMOTE ANNUNCIATOR
(CCT. "R")
SMD
SMP
V
M C
M M
EN-1A
120V
WL
24V TO
PDU 24 +/-
RELAY IN-A-BOX
ABOVE WARNING LIGHT
DS
SWITCH TO PDU
WARNING CONTROL DETAIL
N.T.S.
DOOR POSITION
NURSE CALL SYSTEM
N.T.S.
NCPS
TEKTONE #SS106
24V POWER
SUPPLY
N
120V
SP
PHASE 1
N
SP
N T
N T
TEKTONE #LI123B
DOME LIGHT WITH
BUZZER. (TYP.)
TEKTONE
#SF1172B CALL
STATION WITH
PULL CORD. (TYP.
OF 2)
NCPS
N
120V
N
N T
RELOCATED
DOME LIGHT
RELOCATED
NURSE CALL
DEVICE
RELOCATED
DOME LIGHT
EXISTING
NURSE CALL
DEVICE
EXISTING
NURSE CALL
DEVICE
REMOVED
AND
REINSTALL
REMOVED
AND
REINSTALL
WEST PENN
#WP25243B
(TYP.)
PHASE 3
PHASE 28
TEKTONE PATIENT
DEVICE WITH CALL
CORD. (TYP. OF 2)
NOTE:
1. ITEMS SHOWN ARE GIVEN WITH TEKTONE CATALOG
NUMBERS. EQUIVALENT SYSTEM FROM DUKANE IS
ACCEPTABLE.
SIGNATURE DATE
HATHAWAY
STATE OF O
H IO
P R
O F
ESS IO N
AL E N G
I N
E E
R
R E G I S T E RE D
E-61777
MARLON
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
PHILIP P. KIRK
CHIEF ENGINEER
552-CSI-162
7850 Freeway Circle
440.243.2000 t
Cleveland, OH 44130
440.243.3305 f
Arch. Proj. No.:
C :\U se rs
\M Ky ag ab a\ D oc um en ts
\1
_M
EP
_C
EN
TR
AL
F
IL
E_ m ky ag ab a@ sb m ce
.c om
.rv t
2/
/2
1:
:2
PM
EL4.3
ELECTRICAL DETAILS SITE PREP FOR PET/CT
REPLACEMENT
4100 WEST THIRD STREET,
DAYTON, OHIO 45428
09/16/2020 MCH
BID AND CONSTRUCTION
(REVISED)18111
09/16/2020 Revisions: Date:
35% SUBMISSION 12-12-2019
65% SUBMISSION 02-24-2020
65% RE-SUBMISSION 03-31-2020
95% SUBMISSION 05-08-2020
BID AND CONSTRUCTION 06-12-2020
BID AND CONSTRUCTION (REVISED) 07-13-2020
SOLE SOURCE REVISION 09-16-2020
ADDENDUM NO. 1 02-16-2021
File details come from the government source that posted it. Updated .