This document provides details for a federal contract opportunity to conduct site preparation work for a PET/CT replacement project at the Dayton VA Medical Center in Dayton, Ohio. The project is set aside only for service-disabled veteran-owned small businesses and involves demolishing existing structures and preparing the site for building operations. The contractor will be required to perform at least 25% of the construction work. The solicitation will be posted on November 9, 2020 on SAM.gov and proposals will be due approximately 30 days later. The contract value is estimated between $1 million and $5 million under NAICS code 236220 with a small business size standard of $39.5 million. The work must be completed within 245 calendar days of notice to proceed. The Department of Veterans Affairs Veterans Health Administration VISN 10 is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
0"
QP
FLOOR TO FLOOR
EXPANSION JOINT
EXPANSION JOINT
COVER
PATCH & MATCH
EXISTING SLAB ON
GRADE WHERE WALL
REMOVED
EXISTING SLAB ON
GRADE
NEW SLAB ON GRADE,
SEE STRUCT. DWGS.
2"
EXISTING BUILDING NEW ADDITION
QP
EXISTING BUILDING NEW ADDITION
2"
SCHEDULED CEILING
LINTEL, SEE STRUCT.
DWGS.
COLD-FORMED BOX
HEADER AS REQUIRED
CEILING
10'-0"
CORNER BEAD
GYPSUM BOARD
SOFFIT
EXISTING BRICK WALL
GYPSUM BOARD
T.O. PARAPET
ADDITION
15' - 2"
QP
EXISTING BUILDING NEW ADDITION
EXISTING METAL
COPING
EXISTING BRICK
MASONRY WALL
2"
TPO ROOF MEMBRANE
RIGID INSULATIONRIGID INSULATION
STRUCTURAL STEEL
FRAMING, SEE
STRUCT. DWGS.
ROOF TO WALL
EXPANSION JOINT
TPO ROOF MEMBRANE
RUN TPO MEMBRANE
UNDER EXISTING
COPING
T.O. STEEL
13' - 2"
BRICK (BR-1)
RIGID INSULATION
WATER-RESISTIVE
BARRIER
CORBELED BRICK
(BR-1)
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
BRICK TIE
GYPSUM BOARD
1/2"
5/8" 6" 5/8" 2"
1 1/8"
3 5/8"
1'-2"
T.O. PARAPET
ADDITION
15' - 2"
1/4" / 1'-0"
6 5/8" 6" 5/8" 2"
1 1/8"
3 5/8"
TPO ROOF MEMBRANETPO ROOF MEMBRANE
7" METAL FASCIA
TOP OF BRICK
14'-8"
SEALANT AND BACKER
ROD
BRICK (BR-1)
RIGID INSULATION
BRICK TIE
WATER-RESISTIVE
BARRIER
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
STRUCTURAL STEEL
FRAMING, SEE
STRUCT. DWGS.
RIGID INSULATIONRIGID INSULATION
TPO ROOF MEMBRANE
ROOF SUBSTRATE
BOARD
ROOF VAPOR BARRIER
RIGID INSULATION
TPO ROOF MEMBRANE
RIGID INSULATION
3/4" PLYWOOD
TREATED BLOCKING
AS REQUIRED
ROOF VAPOR BARRIER
1'-8"
T.O. STEEL
13' - 2"
MASONRY VENT @ 24"
O.C. MAX.
T.O. PARAPET
ADDITION
15' - 2"
S
TOP OF STONE
14'-8"
COLD-FORMED METAL
FRAMING
EXT. GYP. SHEATHING
WATER-RESISTIVE
BARRIER
RIGID INSULATION
COLD-FORMED "Z"
THIN CALCIUM
SILICATE UNIT
SEALANT AND BACKER
ROD
TPO ROOF MEMBRANE
7" METAL FASCIA
TPO ROOF MEMBRANE
STRUCTURAL STEEL
FRAMING, SEE
STRUCT. DWGS.
ROOF SUBSTRATE
BOARD
RIGID INSULATION
ROOF VAPOR BARRIER
1/4" / 1'-0"
TPO ROOF MEMBRANE
TPO ROOF MEMBRANE
3/4" PLYWOOD
TREATED BLOCKING
AS REQUIRED
RIGID INSULATION
RIGID INSULATIONRIGID INSULATION
2"2"5/8"6"6 5/8"
1'-8"
T.O. STEEL
13' - 2"
ALUMINUM
INTERMEDIATE
CHANNEL
PLASTIC ISOLATING
SHIM AS REQUIRED
MASONRY WEEP @ 24"
O.C. MAX.
GALVANIZED LOOSE
LINTEL - SEE STRUCT.
DWGS.
STAINLESS STEEL
FLASHING
FIRE RATED
STOREFRONT MULLION
FIRE RATED
INSULATED GLASS
FLEXIBLE FLASHING
BRICK (BR-1)
MORTAR NET
RIGID INSULATION
WATER-RESISTIVE
BARRIER
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
COLD-FORMED BOX
HEADER AS REQUIRED
GYPSUM BOARD
CORNER BEAD
SEALANT AND BACKER
ROD- BOTH SIDES
TREATED BLOCKING
AS REQUIRED
5/8" 6" 5/8" 2"
1 1/8" 3 5/8"
STAINLESS STEEL
FLASHING
FIRE RATED
STOREFRONT MULLION
FIRE RATED
INSULATED GLASS
BRICK (BR-1)
RIGID INSULATION
WATER-RESISTIVE
BARRIER
EXT. GYP. SHEATHING
SEALANT AND BACKER
ROD, BOTH SIDES
WATER-RESISTIVE
BARRIER
TREATED BLOCKING
AS REQUIRED
GYPSUM BOARD
1/4"
COLD-FORMED METAL
FRAMING
SOLID SURFACE
WINDOW SILL
5/8"
1/8" 6"
5/8" 2" 2"
1 3/8" 1 3/8"
THIN CALCIUM
SILICATE UNIT
SEALANT AND BACKER
ROD
ALUMINUM
INTERMEDIATE
CHANNEL
PLASTIC ISOLATING
SHIM AS REQUIRED
COLD-FORMED "Z"
RIGID INSULATION
WATER-RESISTIVE
BARRIER
STAINLESS STEEL
FLASHING
SEALANT AND BACKER
ROD- BEHIND CHANNEL
WEEPS
SEALANT AND BACKER
ROD
WINDOW HEAD
FRAMING MEMBER
INSULATED GLAZING
UNIT
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
COLD-FORMED BOX
HEADER AS REQUIRED
GYPSUM BOARD
CORNER BEAD
TREATED BLOCKING
AS REQUIRED
SCHEDULED CEILING
1"4 1/2"
INSULATED GLAZING
UNIT
WINDOW SILL FRAMING
MEMBER & SILL
RECEPTOR
SEALANT AND BACKER
ROD
STAINLESS STEEL
FLASHING
ALUMINUM TOP
CHANNEL
ALUMINUM
INTERMEDIATE
CHANNEL
THIN CALCIUM
SILICATE UNIT
COLD-FORMED "Z"
RIGID INSULATION
TREATED BLOCKING
AS REQUIRED
WATER-RESISTIVE
BARRIER
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
GYPSUM BOARD
SCHEDULED TILE
FINISH
1/4"
SOLID SURFACE
WINDOW SILL
1"4 1/2"
1 3/8"
1 3/8"
2"2"
5/8"
6"1/8"
5/8"
1/4"
FIRST FLOOR
0"
1'-8"
6" 5/8" 6" 5/8" 2"
1 1/8"
3 5/8"
SOLDIER COURSE
(BR-2)
BRICK (BR-2)
GRADE, HEIGHT
VARRIES
GROUT SOLID
RIGID INSULATION
STAINLESS STEEL
FLASHING
MASONRY WEEP @ 24"
O.C. MAX.
MORTAR NET
BRICK TIE
BRICK (BR-1)
RIGID INSULATION
WATER-RESISTIVE
BARRIER
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
GYPSUM BOARD
FOUNDATION, SEE
STRUCT.DWGS.
ANCHOR BOLT, SEE
STRUCT. DWGS.
FIRST FLOOR
0"
S
1'-8"
1 3/8"
1 3/8"
2"2"5/8"6"
3/4"
3/8"
5/8"
4 7/8"
SOLDIER COURSE
(BR-2)
BRICK (BR-2)
RIGID INSULATION
FOUNDATION, SEE
STRUCT.DWGS.
SEALANT AND BACKER
ROD W/ WEEEPS @ 24"
O.C.
THIN CALCIUM
SILICATE UNIT
COLD-FORMED "Z"
SEALANT AND BACKER
ROD
PLASTIC ISOLATING
SHIM AS REQUIRED
ALUMINUM BOTTOM
CHANNEL
STAINLESS STEEL
FLASHING
BRICK TIE
RIGID INSULATION
WATER-RESISTIVE
BARRIER
EXT. GYP. SHEATHING
COLD-FORMED METAL
FRAMING
3/4" PLYWOOD
GYPSUM BOARD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
PHILIP P. KIRK
CHIEF ENGINEER
552-CSI-162
7850 Freeway Circle
440.243.2000 t
Cleveland, OH 44130
440.243.3305 f
Arch. Proj. No.:
C R e v it L o c a l\ R
S
IT
E P
R E
P P
E T
-C T
J C h o
.r v t
/1
/2
:5
:5
P
M
AS-522
DETAILS SITE PREP FOR PET/CT
REPLACEMENT
4100 WEST THIRD STREET,
DAYTON, OHIO 45428
09/16/2020 CE/RG Author
BID & CONSTRUCTION
(REVISED)18111
SCALE: 1 1/2" = 1'-0"AS-522
11 FLOOR @ EXISTING WALL
SCALE: 1 1/2" = 1'-0"AS-522
6 CEILING @ EXISTING WALL
SCALE: 1 1/2" = 1'-0"AS-522
1 NEW ROOF @ EXISTING PARAPET
SCALE: 1 1/2" = 1'-0"AS-522
16 CORBELED BRICK DETAIL
SCALE: 1 1/2" = 1'-0"AS-522
3 COPING @ BRICK
SCALE: 1 1/2" = 1'-0"AS-522
2 COPING @ STONE VENEER
SCALE: 1 1/2" = 1'-0"AS-522
8 RATED WINDOW HEAD @ BRICK
SCALE: 1 1/2" = 1'-0"AS-522
13 RATED WINDOW SILL @ BRICK
SCALE: 1 1/2" = 1'-0"AS-522
7 WINDOW HEAD @ STONE VENEER
SCALE: 1 1/2" = 1'-0"AS-522
12 WINDOW SILL @ STONE VENEER
SCALE: 1 1/2" = 1'-0"AS-522
18 BRICK WALL @ FIRST FLOOR
SCALE: 1 1/2" = 1'-0"AS-522
17 STONE VENEER WALL @ FIRST fLOOR
Revisions: Date:
65% SUBMISSION 02-24-2020
65% RE-SUBMISSION 03-31-2020
95% SUBMISSION 05-08-2020
BID & CONSTRUCTION 06-12-2020
BID & CONSTRUCTION (REVISED) 07-13-2020
SOLE SOURCE REVISION 09-16-2020
ADDENDUM 1 02-16-2021
| Sheets |
| AS-400 - EXTERIOR ELEVATIONS |
| AS-522 - DETAILS |
File details come from the government source that posted it. Updated .