This document package includes construction documents for renovations to Building 34 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The project scope involves correcting facility condition assessment deficiencies. Drawings cover demolition plans, improvement plans, structural details, mechanical, electrical and plumbing plans, as well as specifications for roofing, windows, doors and other architectural elements. Construction is to adhere to historic preservation standards for the property which is listed on the National Register of Historic Places. The solicitation seeks general contracting services to complete renovations in accordance with the provided design package.
View the file
Other files
Show 40 more
Latest 50 of 58 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CONTRACTOR WILL VERIFY AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS PRIOR TO PLACING BID.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY PROJECT ENGINEER OF ALL
DISCREPANCIES IF ANY, FOUND PRIOR TO PLACEMENT OF ANY COMPONENTS.
3. THE CONTRACTOR WILL TAKE ALL NECESSARY PRECAUTIONS INCLUDING THE BUILDING AND MAINTENANCE OF
DUST TIGHT PARTITIONS, DAILY VACUUMING, SWEEPING, AND PROVISION OF CLEAN FLOOR MATS AT THE PROJECT ENTRANCES, TO PREVENT THE INFILTRATION OF DIRT AND DUST FROM THE CONSTRUCTION AREAS
INTO THE OWNER OCCUPIED AREAS.
4. IF THE PROJECT AREA INCLUDES EXISTING EQUIPMENT, SURFACES, FINISHES, MATERIALS, ETC., NOT TO BE REMOVED, THE CONTRACTOR MUST PROTECT THIS EQUIPMENT FROM DUST, DEBRIS, DAMAGE, ETC. THE CONTRACTOR MUST ALSO CLEAN THESE ITEMS/SURFACES TO THE ORIGINAL CONDITION FOUND AT THE START
OF THE PROJECT PRIOR TO FINAL INSPECTION.
5. PATCH ALL FINISHES WHERE DISTURBED BY THE WORK AND WHERE UNFINISHED SURFACES HAVE BEEN EXPOSED BY DEMOLITION. PATCHING MUST MATCH ADJACENT MATERIALS, COLORS, AND FINISHES. WALL SURFACES THAT ARE PATCHED SHALL HAVE THE FINISHES (PAINT, VINYL WALL COVERING, ETC.) REPLACED
FROM CORNER TO CORNER AND FLOOR TO CEILING.
6. UNLESS OTHERWISE INDICATED, FINISH ALL NEW FRAMES AND PARTITIONS TO MATCH SURROUNDING. NEW HOLLOW METAL DOORS SHALL BE PAINTED SAME COLOR AS FRAMES. EXISTING PARTITIONS RECEIVING NEW DOOR FRAMES THAT HAVE VINYL WALL COVERING (VWC) SHALL HAVE THE VWC COMPLETELY REMOVED AND
REPLACED WITH NEW VWC OF MATCHING TEXTURE AND COLOR.
7. PAINT ALL EXPOSED NEW AND EXISTING PIPING, CONDUIT, WIRE MOLD, ELECTRICAL PANELS, ACCESS PANELS, ETC., TO MATCH WALL FINISH UNLESS OTHERWISE NOTED.
8. WHENEVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED OTHERWISE. AFTER REMOVAL;
FLOORS, WALLS, AND CEILINGS SHALL BE FINISHED TO MATCH ADJOINING SURFACES.
9. UTILITY WORK THAT WILL REQUIRE A SHUTDOWN OF EXISTING SERVICE WILL BE DONE AT TIMES OTHER THAN NORMAL WORKING HOURS AT NO ADDITIONAL COST TO THE GOVERNMENT. WORK MUST BE SCHEDULED WITH
THE VA PROJECT ENGINEER.
10. COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS TO ELIMINATE CONFLICTS AND/OR INTERFERENCES. THE CONTRACTOR SHALL PROVIDE ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM.
11. DRAWINGS ARE DIAGRAMMATIC AND SHOW ONLY THE GENERAL ARRANGEMENT OF EACH SYSTEM. BECAUSE OF SMALL SCALE OF DRAWINGS IT IS NOT POSSIBLE TO SHOW OR INDICATE ALL BRANCHES, OFFSETS, FITTINGS, BOXES, AND ACCESSORIES WHICH MAY BE REQUIRED. CONTRACTOR MUST CAREFULLY INVESTIGATE STRUCTURAL AND FINISH CONDITIONS AFFECTING ALL WORK, FURNISHING SUCH FITTINGS, TRAPS, VALVES, BOXES, ACCESSORIES, ETC., AS MAY BE REQUIRED.
12. LOCATIONS OF NEW EQUIPMENT, PIPING, AND ASSOCIATED ITEMS SHOWN ON THE DRAWINGS ARE SCHEMATIC ONLY. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION AND ELEVATION FOR ALL WORK, INCLUDING CONNECTIONS TO EXISTING WORK. ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR
A COMPLETE AND FUNCTIONAL SYSTEM SHALL BE PROVIDED AT NO ADDITIONAL COST.
13. ALL EXISTING DUCTWORK, ELECTRICAL OR MECHANICAL PIPING, CABLE TRAYS, ETC., IS NOT NECESSARILY SHOWN ON THE DRAWINGS. BEFORE CONTRACTOR PLACES A BID IT IS IMPERATIVE THEY VISIT THE JOBSITE AND FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. IT WILL BE PART OF THE CONTRACTOR'S RESPONSIBILITY AND THE CONTRACTOR WILL BEAR THE COST TO ENGINEER AND RELOCATE ANY EXISTING OBSTACLES WHICH WILL INTERFERE WITH THE CONTRACTOR'S ABILITY TO
INSTALL ALL NEW OR RELOCATED WORK IN THIS PROJECT.
14. CONTRACTOR SHALL NOT INSTALL CONDUIT, PIPING, LIGHTING, OR OTHER OBSTRUCTIONS UNDER OR ADJACENT TO HVAC EQUIPMENT THAT WILL ELIMINATE OR OBSTRUCT ACCESS TO COILS, MOTORS, VALVES, SWITCHES, PANELS, ETC.
15. BEFORE THE CONTRACTOR BEGINS WORK HE SHALL RECORD ANY EXISTING SYSTEM INFORMATION SUCH AS TEMPERATURE, FLOW RATE, PRESSURE, CURRENT, VOLTAGE, OR ANY OTHER INFORMATION NECESSARY FOR HIM TO RETURN THE AFFECTED SYSTEM TO ORIGINAL OPERATING CONDITION. UNLESS NOTED OTHERWISE IT IS ASSUMED THAT ALL SYSTEMS (HVAC, ELECTRICAL, PLUMBING, ETC.) ARE WORKING PROPERLY IN EVERY
MANNER AT THE BEGINNING OF THE PROJECT.
16. THE CONTRACTOR'S RECORDED MEASUREMENTS MUST BE SUBMITTED TO THE PROJECT ENGINEER FOR REVIEW AND ACCEPTANCE BEFORE ANY DEMOLITION OR OTHER RELATED WORK CAN PROCEED.THE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTAINING ALL EXISTING ACCESS DOORS TO CONSTRUCTION AREAS, EXISTING MECHANICAL AND ELECTRICAL AREAS, ASSIGNED STORAGE AREAS, EQUIPMENT ACCESS AREAS, ETC. DOORS MUST BE RESTORED TO THE CONDITION ENCOUNTERED AT BEGINNING OF PROJECT.
THIS INCLUDES DOOR REPLACEMENT, HARDWARE REPLACEMENT, HARDWARE REPAIR, DOOR REPAIR, ETC.
17. NOTE: IF THERE IS ANY WORK TO BE DONE ON EXISTING ROOFS, SUCH AS ROOF PENETRATIONS OR STANDS, OR ANYTHING THAT DAMAGES THE INTEGRITY OF THE ROOF, THIS WORK MUST BE DONE BY A CONTRACTOR LICENSED BY THE ROOFING MEMBRANE MANUFACTURER. HE MUST BE APPROVED BY THE MEMBRANE MANUFACTURER SO AS TO NOT VOID OR INTERRUPT EXISTING SINGLE PLY MEMBRANE ROOF WARRANTIES.
18. CONTRACTOR MUST PROVIDE HIS OWN EQUIPMENT FOR MOVING OF MATERIALS, EQUIPMENT AND TRASH.
THIS INCLUDES CARTS FOR REMOVAL OF DEMOLITION MATERIALS, PALLET JACKS FOR EQUIPMENT MOVING, TWO OR FOUR WHEEL CARTS FOR EQUIPMENT TRANSFER, ETC. CONTRACTOR MAY NOT BORROW VA OWNED
EQUIPMENT FOR THIS PURPOSE.
19. IF ASBESTOS INSULATION IS REMOVED ON THIS PROJECT ALL PIPING AND OTHER MECHANICAL ITEMS THAT HAD THE ASBESTOS INSULATION REMOVED MUST BE REINSULATED WITH MATERIALS ACCORDING TO THE
SPECIFICATIONS.
20. SEVERE NOISE PRODUCING WORK WILL NOT BE ALLOWED DURING NORMAL WORKING HOURS AND MUST BE SCHEDULED WITH THE VA PROJECT ENGINEER FOR OTHER TIMES. THIS INCLUDES JACKHAMMERING
CONCRETE, SAWCUTTING CONCRETE, REPETITIVE HAMMER DRILLING OF CONCRETE, ETC.
21. THE VA DOES NOT PROVIDE TELEPHONE SERVICE OR A TELEPHONE FOR THE CONTRACTORS USE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COVER THE COSTS OF THE INSTALLATION OF A TEMPORARY LAND LINE PHONE. THE CONTRACTOR SHALL CONTACT THE TELEPHONE COMPANY TO HAVE THIS PHONE INSTALLED.
22. ALL CONTRACTOR’S PERSONNEL WHO PLAN TO WORK ON SITE MUST RECEIVE AN ID BADGE THROUGH THE VA’S PIV (PERSONAL IDENTITY VERIFICATION) PROGRAM. THIS REQUIRES HAVING FINGERPRINTS TAKEN AND A
BACKGROUND CHECK DONE BEFORE THE BADGE CAN BE ISSUED.
23. WATER OR LIQUIDS MUST NOT BE ALLOWED TO COME INTO CONTACT WITH NEW OR EXISTING DRYWALL FROM CONSTRUCTION RELATED ACTIVITIES. REMOVE AND REPLACE ANY DRYWALL THAT HAS COME INTO CONTACT
WITH WATER OR OTHER LIQUIDS.
24. LIVE ELECTRICAL CIRCUITS ARE BURIED WITHIN THE CONCRETE FLOOR SLABS AND THERE IS NO RECORD OF THE EXACT LOCATIONS. THE CONTRACTOR SHALL X-RAY THE FLOOR WHEREVER THE CONTRACTOR PLANS ON DRILLING THROUGH THE CONCRETE FLOOR SLABS. IT WILL BE THE CONTRACTOR’S RESPONSIBILITY TO
IMMEDIATELY REPAIR ANY CIRCUIT THAT HAS BEEN CUT OR DAMAGED.
25. WHEN AN EXIT IS CLOSED BECAUSE OF THIS PROJECT THE CONTRACTOR MUST INSTALL BARRICADES AND SIGNAGE AT THE EXIT DOOR. THE CONTRACTOR MUST ALSO COVER OR REMOVE THE LIGHTED EXIT SIGN.
26. WHEN THE CONSTRUCTION REQUIRES THAT EXISTING EXITS FROM THE BUILDING BE BLOCKED OR CLOSED THE CONTRACTOR MUST INSTALL BARRIERS IN FRONT OF THE EXIT TO BLOCK PASSAGE, INSTALL SIGNAGE ON THE BARRIERS OR DOOR STATING THAT THE EXIT IS CLOSED AND COVER THE LIGHTED EXIT SIGN FOR THIS EXIT.
THESE MUST ALL BE REMOVED WHEN THE EXIT IS REOPENED.
27. CONTRACTOR SHALL PROVIDE BOXES, CONDUIT, WIRE, AND RECONNECTIONS AS REQUIRED TO RECONNECT ANY AND ALL EXISTING LIGHT FIXTURES, RECEPTACLES, OR DEVICES REMAINING IN USE. REMOVAL OF ANY ELECTRICAL EQUIPMENT SHALL NOT AFFECT THE OPERATION OF EQUIPMENT REMAINING IN USE.
28. A GREEN GROUND SHALL BE RUN WITH ALL FEEDERS AND WITH ALL CIRCUITS TO RECEPTACLES, MOTORS, FIXED EQUIPMENT, AND APPLIANCES.
29. PANELBOARDS AND CIRCUIT BREAKERS SHALL HAVE THE FOLLOWING MINIMUM INTERRUPTING RATINGS:120/208 - 22,000 AMPERES SYMMETRICAL, 277/480 - 14,000 AMPERES SYMMETRICAL
30. CONTINUITY OF ALL SERVICES TO AND FROM THE FACILITIES IN THE EXISTING BUILDING SHALL BE MAINTAINED WITHOUT INTERRUPTION, EXCEPT FOR SUCH PERIODS OF TIME WHICH THE V.A. MAY DESIGNATE. IF TEMPORARY CONNECTIONS, ETC. ARE NECESSARY TO ASSURE THE CONTINUITY OF SERVICE, THEY SHALL BE FURNISHED WITHOUT ADDITIONAL CHARGE TO THE V.A. AND SHALL BE REMOVED WHEN NO LONGER
NECESSARY.
31. ALL INSTALLATIONS AND EQUIPMENT SHALL FOLLOW THE GUIDELINES ESTABLISHED BY THE CURRENT
NATIONAL ELECTRIC CODE
32. ALL EXISTING CONDUIT AND WIRING MADE ABANDONED BY THIS PROJECT OR FOUND TO BE ABANDONED
DURING DEMOLITION SHALL BE REMOVED.
33. COORDINATE THE PROVISION AND INSTALLATION OF ALL CONTROL WIRING FOR MECHANICAL EQUIPMENT WITH
THE GENERAL CONTRACTOR AND MECHANICAL CONTRACTOR.
34. FOR SAFETY PURPOSES THE CONTRACTOR WILL NOT WORK ON ANY ELECTRICAL EQUIPMENT HOT. ALL
SHUTDOWNS WILL BE SCHEDULED IN ADVANCE WITH THE VA
35. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL
CONDUITS IN WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS
36. FOR DOORS BEING REPLACED AND WALLS WITHIN A CONSTRUCTION AREA: CAREFULLY REMOVE SIGNAGE, ROOM NUMBERS, ARTWORK, ETC., AND STORE IN A PROTECTIVE BOX FOR REINSTALLATION AT COMPLETION OF AREA. ANY DAMAGED SIGNAGE, ARTWORK, ETC., SHALL BE REPLACED WITH NEW. VA INTERIOR DESIGNER
AND COR SHALL IDENTIFY LOCATIONS FOR REINSTALLATION.
37. THE PROPERTY IS LISTED AS A NATIONAL HISTORIC LANDMARK AND LISTED IN THE NATIONAL REGISTER OF HISTORIC PLACES THROUGH THE MOUNTAIN HOME BRANCH CAMPUS. ALL REHABILITATION WORK SHALL MEET THE SECRETARY OF INTERIORS STANDARDS FOR THE TREATMENT OF HISTORIC PROPERTIES FOR
REHABILITATION. HTTPS://WWW.NPS.GOV/TPS/STANDARDS/REHABILITATION.HTM
38. THE WORK IS TO UTILIZE THE PRESERVATION PRINCIPALS FOUND WITHIN THE NATIONAL PARK SERVICE'S
TECHNICAL PRESERVATION BRIEFS FOR REHABILITATION WHICH CAN BE FOUND AT:
HTTPS://WWW.NPS.GOV/TPS/HOW-TO-PRESERVE/BRIEFS.HTM
PROJECT SITE
NAME
ELEVATION
101A
PLAN NORTH
ID
ID
NAME
NO
IDID
0 8' 16'4'C4
DRAWING BLOCK TITLE
1/8" = 1'-0"
NO
SHT
SIM
NO
SHT
SIM
NO
SHT
SIM
BUILDING SECTION IDENTIFICATION
SECTION NUMBER
SHEET NUMBER
WALL SECTION IDENTIFICATION
SECTION NUMBER
SHEET NUMBER
SHEET
ELEV_NO
Ref
R ef
Ref
R ef
EXTERIOR ELEVATION IDENTIFICATION
SHEET
RefEL
R ef
EL
RefEL
R ef
EL
INTERIOR ELEVATION IDENTIFICATION
ELEVATION NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
SHT
NO
SIM
DETAIL/CALLOUT IDENTIFICATION
DETAIL NUMBER
SHEET NUMBER
DRAWING BLOCK TITLE
VIEW NUMBER
VIEW SCALE
VIEW NAME
GRAPHIC SCALE
EXTERIOR ELEVATION IDENTIFICATION
ELEVATION NAME
ELEVATION
NORTH INDICATOR
PROJECT NORTH LINE
TRUE NORTH LINE
COLUMN LINE GRID INDICATOR
ID
GRID IDENTIFICATION
FLOOR PLAN REFERENCE INDICATORS
ROOM TAG
WINDOW TAG
DOOR TAG
PARTITION TAG
REVISION TAG
KEYNOTE TAG
SPOT ELEVATION
TAG
100'-0"
CL CENTER LINE
Abbreviation Term
1WAY one-way 2WAY two-way 3PLY three-ply 3WAY three-way 4WAY four-way
A A LABEL Class A door A/C air condition A/C UNIT air conditioning unit A/E architect/engineer AAP alarm annunciator panel AB anchor bolt ABBRV abbreviation ACC accessible ACOUS INSUL acoustical insulation ACOUS PNL acoustical panel ACS DR access door ACS FLR access floor ACS PNL access panel ACT acoustical ceiling tile ADA Americans with Disabilities Act AFF above finished floor AGGR aggregate AHJ authority having jurisdiction AHU air handling unit AIA American Institute of Architects ALM alarm ALNMT alignment ALT alternate ALT NO alternate number ALUM aluminum ANN annunciator ANOD anodize APC acoustical panel ceiling APPD approved APPROX approximate ARCH Architect ASKLR automatic sprinkler ASPH asphalt ATS automatic transfer switch AV audio visual
B B LABEL Class B door B PL base plate BAS building automation system BB baseboard BC bookcase BD board BDRY boundary BFF below finish floor BHMA Builder's Hardware
Manufacturer's Association BITUM bituminous BLKHD bulkhead BLT IN built-in BLW CLG below ceiling BN bullnose BRCG bracing BRDG bridging BRDG JST bridging joist BRG bearing BRG PL bearing plate BRZ bronze BTWN between BUR built-up roofing
C cont.
CER ceramic CF contractor furnished CF/CI contractor furnished/ contractor installed CF/OI contractor furnished/ owner installed CFE contractor furnished equipment CFLG counterflashing CFMF cold-formed metal framing CG corner guard CHFR chamfer CI cast iron CIP cast-in-place CIR circle CJ control joint CL center line CLDG cladding CLG ceiling CLG DIFF ceiling diffuser CLG GRL ceiling grille CLG HT ceiling height CLG REG ceiling register CLKJ calked joint CLR color CMPST composite CMPTR computer CMU concrete masonry unit CNR corner CNTOR contactor CNTR counter CO cleanout COL column COMM communication CONC concrete CONC FLR concrete floor CONC OPNG concrete opening CONSTR construction CONSULT consultant CONT continue COORD coordinate CORR corridor COV PL cover plate CP control panel CPT carpet CRCMF circumference CRT YD courtyard CS cast stone CSG casing CSI Construction Specifications
Institute CSK counter sunk CSMT casement CSTL cast steel CSWK casework CT ceramic tile CT STN cut stone CTB ceramic tile base CTF ceramic tile floor CTG coating CTR center CTRL control CU FT cubic feet CU IN cubic inch CU YD cubic yard CURT curtain
E E LABEL Class E door EA each EFS exterior finish system EGB exterior gypsum board EGSB exterior gypsum sheathing board EIFS exterior insulation and finish system EJ expansion joint EL elevation ELEC electric ELEV elevator ENTR entrance EOS edge of slab EPS expanded polystyrene board
(insulation) EQ equal EQUIP equipment ESCAL escalator EXST existing EXT exterior EXT GR exterior grade EXT LT exit light
F F BRK fire brick FAAP fire alarm annunciator panel FABL fire alarm bell FABX fire alarm box FACP fire alarm control panel FAR floor area ratio FAS BD fascia board FC BRK face brick FD floor drain FDC fire department connection FDCC fire department connection cabinet FDMPR fire damper FDR fire door FDTN foundation FDV fire department valve FE fire extinguisher FEC fire extinguisher cabinet FF finish face FF BATT foil backed batt insulation FF EL finish floor elevation FF&E furniture, fixture, and equipment FFA from floor above FFB from floor below FH fire hydrant FHC fire hose cabinet FHP full height partition
I IBC International Building Code ID identification ID NO identification number INFO information INSUL insulation INSUL PNL insulated metal panel INT interior
J JAN janitor JAN CLO janitor closet J-BOX junction box JS janitor's sink
K KIT kitchen KPL kickplate KWY keyway
L cont.
LNDSCP landscape LT light LT FLUOR fluorescent lighting LT GA light gage LTG lighting LVR louver LW PLAS lightweight plaster LWC lightweight concrete
M MACH RM machine room MATL material MAX maximum MC moisture content MD metal deck MECH mechanical MECH RM mechanical room MEMB membrane MEP mechanical, electrical, plumbing MEZZ mezzanine MFR manufacturer MIN minimum MIRR mirror MISC miscellaneous MLDG molding (moulding) MLWK millwork MOD modify MOD BIT modified bitumen MR moisture resistant MS mop sink MTL metal MVBL movable MWP membrane waterproofing
N N north NA not applicable NFC National Fire Code NFPA National Fire Protection
Association NIC not in contract NO number NOM nominal NP no paint NRC noise reduction coefficient NTS not to scale
O OA overall OC on center OCC occupy OD outside diameter OF/CI owner furnished/ contractor installed OFD overflow drain OF/OI owner furnished/owner installed OFS outside face of studs OH DR overhead (coiling) door OPNG opening ORD overflow roof drain OVFL overflow
P cont.
PLG piling PLYWD plywood PNL panel PRCST precast PREFIN prefinish PRKG parking PT paint PTN partition PVC polyvinyl chloride (plastic) PVF polyvinyl fluoride (plastic) PVG paving PWR power
S SAT suspended acoustical tile SATC suspended acoustical tile ceiling SB splash block SBS styrene butadien styrene SBSTR substrate SCHED schedule SCMU solid concrete masonry unit SCRN screen SDG siding SDMPR smoke damper SECT section SF square foot (feet) SHT MTL FLASH sheet metal (flashing) SHTHG sheathing SHV shelving SIM similar SJ slab construction joint SLNT sealant SMK smoke SND sanitary napkin dispenser SND INS sound insulation SP EL spot elevation SPEC specification SPKLR sprinkler SQ square SQ IN square inch SQ YD square yard
Q QT quarry tile QTB quarry tile base QTF quarry tile floor QTY quantity
R RB resilient base RB HK robe hook RBM reinforced brick masonry RC reinforced concrete RCP reflected ceiling plan RCPTN reception RD roof drain RDG INS rigid insulation, solid REBAR reinforcing steel bars REF reference REINF reinforce REQ require REQD required RESIL resilient REV revision RHR right hand reverse RL roof leader RLG railing RM room RO rough opening RSD rolling steel door RT right RTF rubber tile floor RTG rating RTU roof top unit RV roof vent RVL reveal
S cont.
SST stainless steel STC sound transmission class STD standard STL JST steel joist STL LNTL steel lintel STL PL steel plate STL RF DK steel roof deck STL TB steel tube STL TR steel truss STOR storage STRUCT structural STRUCT STL structural steel SUSP suspend SUSP CLG suspended ceiling SV sheet vinyl SYM symbol SYS system
T TD trench drain TE top elevation TEMP temporary TFF top of finish floor THK thickness THRU through TMPD tempered TRTD treated TS tube steel TYP typical
U UGND underground UL Underwriters Laboratories UNFIN unfinish UNO unless noted otherwise
V VAN vanity VAP PRF vapor proof VB vinyl base VCT vinyl composition tile VEST vestibule VFAT vinyl faced acoustical tile VNR veneer VR vapor retarder VRFY verify VTR vent through roof
W W CAB wall cabinets W/O without WB wood base WBL wood blocking WC water closet WC WL HNG water closet, wall hung WCLR water cooler WD wood WD LOUV wood louvers WDF wood door and frame WDP wood panelling WF wide flange WF BM beam, wide flange WFAB wall fabric WFR wood frame WFS wood furring strips WGL wired glass WPM waterproof membrane WSCT wainscot
X, Y, Z X BRACE cross brace X SECT cross section XBRA crossbracing XPS extruded polystyrene board
(insulation)
YD yard
Z modulus of section
D cont.
DIM dimension DIST distance DIV division DOC document DPTN demountable partition DR door DR CL door closer DR FR door frame DR OPNG door opening DRH door holder DRLV door louver DRST door stop DRSW door switch DW dishwasher DWG drawing
F cont.
FN fence FR fire rating FRMG framing FRP fiberglass reinforced plastic FRST GL frosted glass FRTW fire retardant treated wood FT feet FTG footing FW fire wall FWRK formwork
G GALV galvanized GC general contractor GFRC glass-fiber-reinforced concrete GFRG glass-fiber-reinforced gypsum GFRP glass-fiber-reinforced plaster GFRP glass-fiber-reinforced plastic GL glass GL BLK glass block GLU LAM glued laminated wood GLZ glazing GLZ CMU glazed concrete masonry unit GPC gypsum plaster ceiling GR BM grade beam GR FL ground floor GR LN grade line GSB gypsum sheathing board GUT gutter GWT glazed wall tile GYM gymnasium GYP gypsum GYP BD gypsum board GYP PLAS gypsum plaster
H HB hose bibb HCP handicapped HCWD hollow core wood door HM hollow metal HMD hollow metal door HMDF hollow metal door and frame HMF hollow metal frame HNDRL handrail HORIZ horizontal HS hand sink HT height HVY heavy HYD hydrant
C C CONC cast concrete C LABEL Class C door CAB cabinet CAC ceiling attenuation class CATW catwalk CBB cementitious (backer) board CEM cement CEM FIN cement finish CEM PLAS cement plaster CEM PLAS CLGcement plaster ceiling
D D LABEL Class D door DBL double DBL ACT DR double acting door DBL GLZ double glaze DEMO demolition DEPT department DET detail DF drinking fountain DF WL MTDdrinking fountain, wall mounted DIA diameter
F FIN finish FIXT fixture FLG flooring FLR floor FLR FIN floor finish FLR PL floor plate FLR SK floor sink
L LAM laminate LAV lavatory LBS pounds LED light emitting diode LF linear feet (foot) LF INS loose fill insulation LKR RM locker room LL low level
P PAR parapet PAT pattern PB pull box PBD particleboard PCC precast concrete PCP portland cement plaster PERF perforated PERIM perimeter PGBD pegboard PIL pilaster PL property line PL GL plate glass PLAM plastic laminate PLAS plaster PLBG plumbing
CONCRETE,
CAST-IN-PLACE
GROUT
BRICK,
COMMON/FACE
CONCRETE
MASONRY UNIT
STONE,
CAST
ALUMINUM
ORNAMENTAL
METAL
STEEL AND
OTHER METALS
INSULATION,
LOOSE FILL OR
BLANKET
INSULATION,
RIGID BOARD
SHEET METAL
PLASTER,
GYPSUM OR
PORTLAND CEMENT
EARTH,
CRUSHED ROCK
GRAVEL
EARTHWORK,
COMPACTED
FILL
SAND
CMU
BOND BEAM
LINTEL
CMU, END
PLYWOOD
WOOD BLOCKING
OR SHIM
WOOD FRAMING,
CONTINUOUS
GLASS, ELEVATION
OWNER:
James H. Quillen VA Medical Center 53 Memorial Ave Bldg 34 Johnson City, Tennessee (Mountain Home) P: (423)926-1171 C: Aaron Prosak, Engineering Technician E: aaron.prosak@va.gov
ARCHITECT:
GLMV Architecture, Inc.
1525 E. Douglas Wichita, KS 67211 P: (316) 265-9367 F: (316) 265-5646 C: Fred Britain, AIA, Project Manager E: fred.britain@glmv.com
HISTORIC PRESERVATION ARCHITECT:
STRATA Architecture, Inc.
1701 Oak Street, Suite 100 Kansas City, MO 64108 P: (816) 474-0900 C: Trudy Faulkner E: trudy@strata-arch.com
MECHANICAL / ELECTRICAL / PLUMBING:
AME Consulting Engineers 705 E. Morehead St.
Charlotte, NC 28202
FIRE PROTECTION ENGINEER:
GHD Cons Services, Inc.
222 S. Church St. #400 Charlotte, NC 28202 P: (704) 342-4910 C: Charles Hahl E: eric.okurowski@ghd.com
INDUSTRIAL HYGIENIST
Terracon 72 Pointe Circle Greenville, SC 29615 P: (864) 292-2901 C: Jeffrey Gurrie, CIH E: jeff.gurrie@terracon.com
ARCHITECT / ENGINEEROWNER
CONSULTANTS
ARCHITECT OF RECORD:
Atriax, pllc 102 3rd Avenue NE Hickory, NC 28601 (PO Box 1629 Hickory, NC 28603) P: (828) 315-9962 C: Bob Sinclair E: bob.sinclair@atriaxgroup.com
P: (704) 295-4263 C: James Dinkler, PE E: jdinkler@ame-pc.com
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
Dwg. of o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans
Health
Administration
Medical Center Director: Date:
Associate Medical Center Director: Date:
Engineering M&O Foreman: Date:
Chief Engineering Service: Date:
Boiler Plant Foreman: Date:
Safety Manager: Date:
Industrial Hygenist: Date:
Infection Control Nurse: Date:
Energy Manager: Date:
Approved: Date:
Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GHD Cons Services, Inc.
Fire Protection Engineer 222 S. Church St. #400, Charlotte, NC 28202
Phone: 704-342-4910 www.ghd.com
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
AME Consulting Engineers MEP Engineers 705 E. Morehead St., Charlotte, NC 28202
Phone: 704-295-4263 www.ame-pc.com
STRATA Architecture, Inc.
Historic Preservation Architect 1701 Oak Street, Suite 100, Kansas City, MO 64108
Phone: 816-474-0900 www.strata-arch.com
Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
/1
/2
:2
:5
P M
B
IM
/1
.1
M tn
H o m e V
A
B ld g
R e n o v
-9
.1
.A rc h
-M tn
H o m e .r v t
34-G-001
COVER SHEET Renovate Building 34 to Correct FCA Deficiencies
James H. Quillen VAMC Mountain Home, TN
621-18-102
07/24/2020 FAB JSR 1 149
SHEET NUMBER SHEET NAME REV. NO.
34-PD-111 PLUMBING - FIRST FLOOR DEMOLITION PLAN - AREA A
34-PD-112 PLUMBING - FIRST FLOOR DEMOLITION PLAN - AREA B
34-PD-121 PLUMBING - SECOND FLOOR - ATTIC DEMOLITION PLAN - AREA A
34-PD-122 PLUMBING - SECOND FLOOR - ATTIC DEMOLITIONPLAN - AREA B
34-PL-101 PLUMBING - LOWER LEVEL WASTE & VENT PLAN - AREA A
34-PL-102 PLUMBING - LOWER LEVEL WASTE & VENT PLAN - AREA B
34-PL-111 PLUMBING - FIRST FLOOR WASTE & VENT PLAN - AREA A
34-PL-112 PLUMBING - FIRST FLOOR WASTE & VENT PLAN - AREA B
34-PL-121 PLUMBING - SECOND FLOOR - ATTIC WASTE & VENT PLAN - AREA A
34-PL-122 PLUMBING - SECOND FLOOR - ATTIC WASTE & VENT PLAN - AREA B
34-PL-131 PLUMBING - LOWER LEVEL WATER PLAN - AREA A
34-PL-132 PLUMBING - LOWER LEVEL WATER PLAN - AREA B
34-PL-141 PLUMBING - FIRST FLOOR WATER PLAN - AREA A
34-PL-142 PLUMBING - FIRST FLOOR WATER PLAN - AREA B
34-PL-151 PLUMBING - SECOND FLOOR - ATTIC WATER PLAN - AREA A
34-PL-152 PLUMBING - SECOND FLOOR - ATTIC WATER PLAN - AREA B
34-P-501 PLUMBING - RISERS
34-P-701 PLUMBING - DETAILS
MECHANICAL
34-M-001 MECHANICAL - GENERAL NOTES AND LEGENDS
34-MD-101 MECHANICAL - LOWER LEVEL - AREA A DUCTWORK PLAN - DEMOLITION
34-MD-111 MECHANICAL - FIRST FLOOR - AREA A DUCTWORK PLAN - DEMOLITION
34-MD-112 MECHANICAL - FIRST FLOOR - AREA B DUCTWORK PLAN - DEMOLITION
34-MD-121 MECHANICAL - ATTIC-SECOND FLOOR DUCTWORK PLANS - DEMOLITION
34-MD-201 MECHANICAL - LOWER LEVEL - AREA A PIPING PLAN - DEMOLITION
34-MD-202 MECHANICAL - LOWER LEVEL - AREA B PIPING PLAN - DEMOLITION
34-MD-211 MECHANICAL - FIRST FLOOR - AREA A PIPING PLAN - DEMOLITION
34-MD-212 MECHANICAL - FIRST FLOOR - AREA B PIPING PLAN - DEMOLITION
34-MD-221 MECHANICAL - ATTIC-SECOND FLOOR PIPING PLANS - DEMOLITION
34-MH-111 MECHANICAL - FIRST FLOOR - AREA A DUCTWORK PLAN
34-MH-121 MECHANICAL - ATTIC DUCTWORK PLAN
34-MP-101 MECHANICAL - LOWER LEVEL - AREA A PIPING PLAN
34-MP-102 MECHANICAL - LOWER LEVEL - AREA B PIPING PLAN
34-MP-111 MECHANICAL - FIRST FLOOR - AREA A PIPING PLAN
34-MP-112 MECHANICAL - FIRST FLOOR - AREA B PIPING PLAN
34-MP-121 MECHANICAL - ATTIC-SECOND FLOOR PIPING PLANS
34-MP-401 MECHANICAL - ENLARGED PIPING PLANS
34-M-601 MECHANICAL- SCHEDULES
34-M-602 MECHANICAL - PIPING DIAGRAM
34-M-603 MECHANICAL - PIPING DIAGRAM
34-M-701 MECHANICAL - DETAILS
34-M-702 MECHANICAL - DETAILS
34-M-703 MECHANICAL - CONTROLS
34-M-704 MECHANICAL - CONTROLS
34-M-705 MECHANICAL - CONTROLS
ELECTRICAL
34-E-001 ELECTRICAL - GENERAL NOTES AND LEGENDS
34-ED-101 ELECTRICAL - LOWER LEVEL DEMOLITION PLAN - AREA A
34-ED-102 ELECTRICAL - LOWER LEVEL DEMOLITION PLAN - AREA B
34-ED-111 ELECTRICAL - FIRST FLOOR DEMOLITION PLAN - AREA A
34-ED-112 ELECTRICAL - FIRST FLOOR DEMOLITION PLAN - AREA B
34-ED-121 ELECTRICAL - SECOND FLOOR - ATTIC DEMOLITION PLAN - AREA A
34-ED-122 ELECTRICAL - SECOND FLOOR - ATTIC DEMOLITION PLAN - AREA B
34-EL-101 ELECTRICAL - LOWER LEVEL LIGHTING PLAN - AREA A
34-EL-102 ELECTRICAL - LOWER LEVEL LIGHTING PLAN - AREA B
34-EL-111 ELECTRICAL - FIRST FLOOR LIGHTING PLAN - AREA A
34-EL-112 ELECTRICAL - FIRST FLOOR LIGHTING PLAN - AREA B
34-EL-121 ELECTRICAL - SECOND FLOOR - ATTIC LIGHTING PLAN - AREA A
34-EL-122 ELECTRICAL - SECOND FLOOR - ATTIC LIGHTING PLAN - AREA B
34-EP-101 ELECTRICAL - LOWER LEVEL POWER PLAN - AREA A
34-EP-102 ELECTRICAL - LOWER LEVEL POWER PLAN - AREA B
34-EP-111 ELECTRICAL - FIRST FLOOR POWER PLAN - AREA
34-EP-112 ELECTRICAL - FIRST FLOOR POWER PLAN - AREA B
34-EP-121 ELECTRICAL - SECOND FLOOR - ATTIC POWER PLAN - AREA A
34-EP-122 ELECTRICAL - SECOND FLOOR - ATTIC POWER PLAN - AREA B
34-ES-101 ELECTRICAL - LOWER LEVEL SECURITY PLAN - AREA A
34-ES-102 ELECTRICAL - LOWER LEVEL SECURITY PLAN - AREA B
34-ES-111 ELECTRICAL- SECURITY PLAN- AREA A
34-ES-112 ELECTRICAL- SECURITY PLAN- AREA B
34-ES-122 ELECTRICAL- SECURITY PLAN / ATTIC SECURITY PLAN - AREA B
34-E-501 ELECTRICAL - EXISTING POWER RISER DIAGRAM
34-E-502 ELECTRICAL - NEW POWER RISER DIAGRAM
34-E-601 ELECTRICAL- SCHEDULES
34-E-602 ELECTRICAL- PANEL SCHEDULES
34-E-603 ELECTRICAL- PANEL SCHEDULES
34-E-604 ELECTRICAL- PANEL SCHEDULES
34-E-605 ELECTRICAL- PANEL SCHEDULES
34-E-606 ELECTRICAL- PANEL SCHEDULES
34-E-701 ELECTRICAL - DETAILS
SHEET NUMBER SHEET NAME REV. NO.
GENERAL
34-G-001 COVER SHEET
34-G-002 CONCEPT LAYOUT
34-GI-001 CODE SUMMARY
34-GI-002 CODE FLOOR PLAN
34-GI-003 CODE FLOOR PLAN
34-GI-004 CODE FLOOR PLAN
STRUCTURAL
34-S-101 SLAB INFILL - LOWER LEVEL FLOOR AREA B
ARCHITECTURAL
34-AD-101 DEMOLITION PLANS - LOWER LEVEL & 1ST FLOOR PLANS OVERALL
34-AD-102 DEMOLITION PLANS - 2ND FLOOR & ROOF OVERALL 1
34-AD-103 DEMOLITION FLOOR PLAN - LOWER LEVEL FLOOR AREA A 1
34-AD-104 DEMOLITION FLOOR PLAN - LOWER LEVEL FLOOR AREA B 1
34-AD-105 DEMOLITION FLOOR PLAN - 1ST FLOOR AREA A 1
34-AD-106 DEMOLITION FLOOR PLAN - 1ST FLOOR AREA B 1
34-A-101 IMPROVEMENT PLANS - LOWER LEVEL & 1ST FLOOR OVERALL
34-A-102 IMPROVEMENT PLANS - 2ND FLOOR & ROOF PLAN OVERALL 1
34-A-103 IMPROVEMENT PLAN - LOWER LEVEL FLOOR AREA A
34-A-104 IMPROVEMENT PLAN - LOWER LEVEL FLOOR AREA B
34-A-105 IMPROVEMENT PLAN - 1ST FLOOR AREA A 1
34-A-106 IMPROVEMENT PLAN - 1ST FLOOR AREA B
34-A-111 RCP IMPROVEMENT LOWER LEVEL & 1ST FLOOR OVERALL
34-A-112 RCP IMPROVEMENT 1ST & 2ND LEVEL
34-A-201 EXTERIOR ELEVATIONS - IMPROVEMENT
34-A-202 EXTERIOR ELEVATIONS - IMPROVEMENT
34-A-301 BUILDING SECTIONS
34-A-302 BUILDING SECTIONS
34-A-601 DOOR DETAILS & SCHEDULE
34-A-602 ROOF DETAILS
ABATEMENT
34-AR-1 ABESTOS ABATEMENT PLAN
34-AR-2 ABESTOS ABATEMENT PLAN
34-AR-3 ABESTOS ABATEMENT PLAN
FIRE PROTECTION
34-FA-001 FIRE ALARM- REFERENCE SHEET
34-FA-101 FIRE ALARM - BASEMENT & 1ST FLOOR NEW PLAN OVERALL
34-FA-102 FIRE ALARM - 2ND FLOOR & BELL TOWER NEW PLAN OVERALL
34-FA-103 FIRE ALARM - BASEMENT FLOOR NEW WORK- AREA A
34-FA-104 FIRE ALARM- BASEMENT FLOOR NEW WORK- AREA B
34-FA-105 FIRE ALARM- 1ST FLOOR NEW WORK- AREA A
34-FA-106 FIRE ALARM- 1ST FLOOR NEW WORK- AREA B
34-FA-107 FIRE ALARM- 2ND FLOOR NEW WORK- AREA A
34-FA-108 FIRE ALARM- 2ND FLOOR NEW WORK- AREA B
34-FA-501 FIRE ALARM - DETAIL SHEET
34-FA-601 FIRE ALARM- RISER DIAGRAM & MATRIX
34-FJ-101 FIRE ALARM- BASEMENT & 1ST FLOOR OVERALL DEMOLITION PANS
34-FJ-102 FIRE ALARM- 2ND FLOOR OVERALL PLANS
34-FJ-103 FIRE ALARM- BASEMENT FLOOR DEMOLITION- AREA A
34-FJ-104 FIRE ALARM- BASEMENT FLOOR DEMOLITION- AREA B
34-FJ-105 FIRE ALARM- 1ST FLOOR DEMOLITION- AREA A
34-FJ-106 FIRE ALARM- 1ST FLOOR DEMOLITION- AREA B
34-FJ-107 FIRE ALARM- 2ND FLOOR DEMOLITION- AREA A
34-FJ-108 FIRE ALARM- 2ND FLOOR DEMOLITION- AREA B
34-FK-101 SPRINKLER - BASEMENT & 1ST FLOOR DEMOLITION PLANS OVERALL
34-FK-102 SPRINKLER - 2ND FLOOR MECH. MEZZANINE, AND BELL TOWER DEMO PLAN- OVERALL
34-FK-103 SPRINKLER- BASEMENT FLOOR DEMOLITION- AREA A
34-FK-104 SPRINKLER- BASEMENT FLOOR DEMOLITION- AREA B
34-FK-105 SPRINKLER- 1ST FLOOR DEMOLITION- AREA A
34-FK-106 SPRINKLER- 1ST FLOOR DEMOLITION- AREA B
34-FK-107 SPRINKLER- 2ND FLOOR DEMOLITION- AREA A
34-FK-108 SPRINKLER- 2ND FLOOR AND BELL TOWER DEMOLITION- AREA B
34-FX-001 SPRINKLER- REFERENCE SHEET
34-FX-101 SPRINKLER- BASEMENT & 1ST FLOOR NEW PLAN OVERALL
34-FX-102 SPRINKLER- 2ND FLOOR & BELL TOWER NEW PLAN OVERALL
34-FX-103 SPRINKLER- LOWER LEVEL FLOOR NEW WORK- AREA A
34-FX-104 SPRINKLER- LOWER LEVEL FLOOR NEW WORK- AREA B
34-FX-105 SPRINKLER- 1ST FLOOR NEW WORK- AREA A
34-FX-106 SPRINKLER- 1ST FLOOR NEW WORK- AREA B
34-FX-107 SPRINKLER- 2ND FLOOR NEW WORK- AREA A
34-FX-108 SPRINKLER- 2ND FLOOR NEW WORK- AREA B
34-FX-501 SPRINKLER - DETAIL SHEET
34-FX-502 SPRINKLER - DETAIL SHEET
34-FX-601 SPRINKLER - RISER DIAGRAM & SCHEDULES
PLUMBING
34-P-001 PLUMBING - GENERAL NOTES, SCHEDULES AND LEGENDS
34-PD-101 PLUMBING - LOWER LEVEL DEMOLITION PLAN - AREA A
34-PD-102 PLUMBING - LOWER LEVEL DEMOLITION PLAN - AREA B
ARCHITECTURAL LEGEND MISC. ARCHITECTURAL SYMBOLS SHEET INDEX
SITE LOCATION
DEPARTMENT OF VETERANS AFFAIRS
GENERAL NOTES
ARCHITECTURAL ABBREVIATIONS
JAMES H. QUILLEN VA MEDICAL CENTER - JOHNSON CITY, TENNESSEE (MOUNTAIN HOME)
PROJECT NO. 621-18-102
RENOVATE BLDG. 34 TO CORRECT FCA DEFICIENCIES
DIRECTORY
Revisions: Date:
DN
UP
DN
LOWER ROOF
REF. ROOF PLAN
LOWER ROOF
REF. ROOF PLAN
LOWER ROOF
REF. ROOF PLAN
LOWER ROOF
REF. ROOF PLAN
LOWER ROOF
REF. ROOF PLAN
LOWER ROOF
REF. ROOF PLAN
LOWER ROOF
REF. ROOF PLAN
OPEN TO BELOW
OPEN TO BELOW
6 7
DEDUCT
DEDUCT
DEDUCT13 DEDUCT
DEDUCT
DEDUCT
17 17
HATCH LEGEND
REFERENCE ASSOCIATED KEYNOTE 8 FOR MORE INFORMATION
EXISTING WALL / PARTITION TO REMAIN
EXISTING LOAD-BEARING WALL / PARTITION TO REMAIN
AREA NOT INCLUDED IN SCOPE OF WORK
NEW WALL / PARTITION CONSTRUCTION
LINETYPE LEGEND
LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN
HEAVY DASHED LINE INDICATES EXISTING ELEMENT TO BE
REMOVED IN ITS ENTIRETY
SHEET KEYNOTES
CLASSROOM
LOUNGE
STORAGECLOS
CORRIDOR
RESTROOM
STORAGE RM
CLASSROOM
STORAGE RM
CLASSROOM
STORAGE RM
STAIRS
ROOF TYPE LEGEND
SLATE TILE
NEW ASPHALT SHINGLE
LOW PROFILE STANDING SEAM METAL ROOF
NEW TPO
GENERAL NOTES
1. REMOVE ENTIRE MECHANICAL, ELECTRICAL, PLUMBING, TELECOMMUNICATIONS (MEP/T)
SYSTEMS AS NOTED.
2. REMOVE ALL INTERIOR PARTITIONS AND ASSOCIATED DOORS IN THEIR ENTIRETY AS NOTED.
3. REMOVE ALL INTERIOR CEILINGS AND ASSOCIATED LIGHT FIXTURES AND CEILING DIFFUSERS
IN THEIR ENTIRETY AS NOTED.
4. ANY DEMOLITION OR DISTURBANCE TO BLOCK WALLS CONTAINING ASBESTOS ARE
REQUIRED TO BE REMOVED BY THE ABATEMENT CONTRACTOR.
5. REMOVE AND DISPOSE OF ALL ASBESTOS-CONTAINING INSULATION IN WALLS AND ABOVE
CEILINGS.
6. REMOVE AND DISPOSE OF ALL ASBESTOS-CONTAINING MASTIC ON CORK INSULATION AND
ORIGINAL COOLER WALLS/CEILINGS.
7. SALVAGE DOOR, TRIM AND FRAME FOR POTENTIAL REINSTALLATION OR OTHER WOOD
FRAME REPAIRS WHEREVER INDICATED ON AREA DEMOLITION DRAWINGS.
ROOF GENERAL NOTES
• FLY OVER VIDEO SHOWING ROOFING CONDITIONS IS AVAILABLE FOR REVIEW. THIS VIDEO
IS INCLUDED AND CONSIDERED A CONSTRUCTION DOCUMENT. GENERAL CONTRACTOR
AND APPLICABLE SUB-CONTRACTORS SHALL REVIEW VIDEO.
• GENERAL CONTRACTOR AND APPLICABLE SUB-CONTRACTORS SHALL INSPECT DECKING
CONDITIONS UNDERNEATH ROOF DURING WALK THROUGH
• GENERAL CONTRACTOR SHALL PROVIDE AND REVIEW SURVEY REPORT OF EXPECTED
ROOF REPAIRS WITH COR BEFORE CONSTRUCTION BEGINS.
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
Dwg. of o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans
Health
Administration Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GHD Cons Services, Inc.
Fire Protection Engineer 222 S. Church St. #400, Charlotte, NC 28202
Phone: 704-342-4910 www.ghd.com
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
AME Consulting Engineers MEP Engineers 705 E. Morehead St., Charlotte, NC 28202
Phone: 704-295-4263 www.ame-pc.com
STRATA Architecture, Inc.
Historic Preservation Architect 1701 Oak Street, Suite 100, Kansas City, MO 64108
Phone: 816-474-0900 www.strata-arch.com
Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
B
A
KEYPLAN
TRUE NORTH
/1
/2
:2
:4
P M
B
IM
/1
.1
M tn
H o m e V
A
B ld g
R e n o v
-9
.1
.A rc h
-M tn
H o m e .r v t
34-AD-102
DEMOLITION PLANS - 2ND FLOOR &
ROOF OVERALL
Renovate Building 34 to Correct FCA Deficiencies
James H. Quillen VAMC Mountain Home, TN
621-18-102
07/24/2020 FAB JSR 9 149
0 16' 32'8'1/16" = 1'-0"A
SECOND FLOOR / ATTIC DEMOLITION PLAN
0 16' 32'8'1/16" = 1'-0"B
ROOF DEMOLITION PLAN
1 EXISTING GUTTER TO REMAIN. REPAIR/REPLACE TO ALLOW PROPER DRAINAGE WITHOUT LEAKS.
MATCH HISTORIC SIZE, PROFILE, AND MATERIALS IN CASE NEEDED TO REPLACE.
2 REMOVE EXISTING HVAC UNIT AND ASSOCIATED DUCTWORK & CONNECTIONS IN THEIR ENTIRETY
3 REMOVE EXISTING HVAC UNIT STRUCTURAL SUPPORT IN THEIR ENTIRETY. PATCH & REPAIR ROOF
AS REQUIRED.
4 REPAIR/REPLACE THROUGH WALL SCUPPER AND DOWNSPOUT TO PREVENT WATER INFILTRATION
5 REPAIR/REPLACE FLASHING/SEALANT AT CLERESTORY.
6 EXISTING SKYLIGHT TO BE REMOVED.
7 EXISTING ROOF ACCESS HATCH TO REMAIN. REPAIR/REPLACE FLASHING/SEALANTS
8 EXISTING ROOFTOP EXHAUST FANS. REF. MECHANICAL FOR MORE INFORMATION.
9 EXISTING AHU FAN REF. MECHANICAL FOR MORE INFORMATION.
10 REPAIR/REPLACE EXISTING METAL COPING PARAPET CAP.
11 REPAIR/REPLACE EXISTING TRANSITION FLASHING AROUND TPO PERIMETER
12 REPAIR/REPLACE EXISTING LIGHTNING ROD CONNECTIONS.
13 REPAIR/REPLACE FLASHING/SEALANTS AT CRICKET.
14 REPAIR/ REPLACE THROUGH WALL SCUPPER AND DOWNSPOUT TO PREVENT WATER INFILTRATION
15 DEMOLISH EXISTING ROOF SYSTEM DOWN TO DECKING AND PREP FOR NEW ROOF SYSTEM AS
NOTED ON ROOF PLAN
16 SALVAGE DOOR, TRIM AND FRAME FOR POTENTIAL REINSTALLATION OR OTHER WOOD FRAME
REPAIRS.
17 REMOVE AREA OF SLATE TILE ROOF SYSTEM DOWN TO ROOF DECK.
18 REMOVE ALL INSULATED STUD WALL WITH GYP. BOARD FINISH PARTITIONS IN ITS ENTIRETY
19 DEMO PORTION OF WALL AND PREP OPENING FOR NEW DOOR AND FRAME. REF. IMPROVEMENT
PLANS.
20 REMOVE CARPET AND RUBBER WALL BASE IN ITS ENTIRETY
21 REMOVE VCT AND RUBBER WALL BASE IN ITS ENTIRETY
22 REMOVE ACT ASSEMBLY IN ITS ENTIRETY
PLAN NORTH PLAN NORTH
Revisions: Date:
Revision 1 1/27/2021
UP
UP
/A 34-AD-104/A 34-AD-104
26 17
40 4040
40 40
40 39
40 39
38 39
CWT CO-ORDR
E007
OFFICE
E008
PRINT SHOP CO-ORDR
E006
MEN'S TOILET
E004
WOMEN'S TOILET
E003
HVAC
E002
OFFICE
E014 OFFICE
E015
OFFICE
E016
TOILET
E017
OFFICE
E013
SHOP
E001
OFFICE
E009
CWT SHOP OFFICES
E005
PRINT SHOP
E010
DARK RM
E018
STORAGE
E019
MAINTENANCE UNIT B
STORAGE
E021
HVAC STORAGE
E023
ELECTRICAL ROOM
E026
MAINTENANCE UNIT B
E022
HVAC
E027
MEN'S
E028
WOMEN'S
E029
OFFICE
E030
PRINT SHOP
E010b
CORRIDOR
E025
BREAK ROOM
E024
MEN'S TOILET
E045
STORAGE
E042
STORAGE
E043
TRANS VAULT
E044
CORRIDOR
E041
CORRIDOR
E040
ELEV
E011
ELEV EQUIP.
E012
CORRIDOR
E020
UNEXCAVATED
UNEXCAVATED
OFFICE
E031
OFFICE
E032
UNEXCAVATED
E035
HATCH LEGEND
REFERENCE ASSOCIATED KEYNOTE 8 FOR MORE INFORMATION
EXISTING WALL / PARTITION TO REMAIN
EXISTING LOAD-BEARING WALL / PARTITION TO REMAIN
AREA NOT INCLUDED IN SCOPE OF WORK
NEW WALL / PARTITION CONSTRUCTION
LINETYPE LEGEND
LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN
HEAVY DASHED LINE INDICATES EXISTING ELEMENT TO BE
REMOVED IN ITS ENTIRETY
SHEET KEYNOTES
GENERAL NOTES
1. REMOVE ENTIRE MECHANICAL, ELECTRICAL, PLUMBING, TELECOMMUNICATIONS (MEP/T)
SYSTEMS AS NOTED.
2. REMOVE ALL INTERIOR PARTITIONS AND ASSOCIATED DOORS IN THEIR ENTIRETY AS NOTED.
3. REMOVE ALL INTERIOR CEILINGS AND ASSOCIATED LIGHT FIXTURES AND CEILING DIFFUSERS
IN THEIR ENTIRETY AS NOTED.
4. ANY DEMOLITION OR DISTURBANCE TO BLOCK WALLS CONTAINING ASBESTOS ARE
REQUIRED TO BE REMOVED BY THE ABATEMENT CONTRACTOR.
5. REMOVE AND DISPOSE OF ALL ASBESTOS-CONTAINING INSULATION IN WALLS AND ABOVE
CEILINGS.
6. REMOVE AND DISPOSE OF ALL ASBESTOS-CONTAINING MASTIC ON CORK INSULATION AND
ORIGINAL COOLER WALLS/CEILINGS.
7. SALVAGE DOOR, TRIM AND FRAME FOR POTENTIAL REINSTALLATION OR OTHER WOOD
FRAME REPAIRS WHEREVER INDICATED ON AREA DEMOLITION DRAWINGS.
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
Dwg. of o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans
Health
Administration Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GHD Cons Services, Inc.
Fire Protection Engineer 222 S. Church St. #400, Charlotte, NC 28202
Phone: 704-342-4910 www.ghd.com
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
AME Consulting Engineers MEP Engineers 705 E. Morehead St., Charlotte, NC 28202
Phone: 704-295-4263 www.ame-pc.com
STRATA Architecture, Inc.
Historic Preservation Architect 1701 Oak Street, Suite 100, Kansas City, MO 64108
Phone: 816-474-0900 www.strata-arch.com
Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
A
KEYPLAN
TRUE NORTH
/1
/2
:2
:4
P M
B
IM
/1
.1
M tn
H o m e V
A
B ld g
R e n o v
-9
.1
.A rc h
-M tn
H o m e .r v t
34-AD-103
DEMOLITION FLOOR PLAN - LOWER
LEVEL FLOOR AREA A
Renovate Building 34 to Correct FCA Deficiencies
James H. Quillen VAMC Mountain Home, TN
621-18-102
07/24/2020 FAB JSR 10 149
0 8' 16'4'1/8" = 1'-0"A
LOWER LEVEL DEMOLITION PLAN AREA A
PLAN NORTH
1 EXISTING ELEVATOR EQUIPMENT ROOM AND ELEVATOR TO REMAIN
2 EXISTING ELECTRICAL ROOM TO REMAIN OPERATIONAL. REF. ELECTRICAL DRAWINGS FOR EXITING
ELECTRICAL EQUIPMENT TO REMAIN.
3 EXISTING HVAC ROOM TO REMAIN OPERATIONAL. REF. MECHANICAL DRAWINGS FOR EXISTING
EQUIPMENT TO REMAIN
4 EXISTING TRANS VAULT TO REMAIN OPERATIONAL. REF. ELECTRICAL DRAWINGS FOR EXISTING
EQUIPMENT TO REMAIN.
5 EXISTING LOAD BEARING WALL TO REMAIN
6 EXISTING MECHANICAL ROOM TO REMAIN OPERATIONAL. NO DEMO WORK TO BE DONE.
8 DEMO EXISTING FLOOR SLAB AND STRUCTURAL SUPPORT IN THEIR ENTIRETY, AS SHOWN WITHIN
HATCHED AREA. PREP FLOOR OPENING FOR NEW CONCRETE INFILL
9 EXISTING PLASTER CEILING TO REMAIN. PATCH/REPAIR AS REQUIRED.
10 EXISTING SPIRAL STAIR TO REMAIN. PATCH/REPAIR AS REQUIRED.
11 REMOVE EXISTING LOCKERS IN THEIR ENTIRETY. VA TO REMOVE ALL FURNITURE AND EQUIPMENT
UNLESS OTHERWISE NOTED.
12 EXISTING EXTERIOR DOOR TO REMAIN. REPAIR/REPLACE WEATHER SEALS AND THRESHOLD AS
NEEDED.
13 REMOVE ALL EXISTING REFRIGERATOR AND ASSOCIATED COMPONENTS IN THEIR ENTIRETY.
14 EXISTING INTERIOR DOOR TO REMAIN
15 EXISTING STAIR TO REMAIN
16 EXISTING PAINT BOOTH TO REMAIN
17 REMOVE DOOR AND FRAME IN THEIR ENTIRETY. SALVAGE DOOR AND FRAME TO BE RETURNED TO
VA.
18 REMOVE EXTERIOR DOOR AND FRAME IN THEIR ENTIRETY. SALVAGE DOOR AND FRAME TO BE
RETURNED TO VA. SEE IMPROVEMENT PLANS AND DOOR SCHEDULE FOR NEW DOOR.
19 REMOVE EXTERIOR STOREFRONT AND FRAME IN THEIR ENTIRETY. SALVAGE STOREFRONT AND
FRAME TO BE RETURNED TO VA. SEE IMPROVEMENT PLANS AND DOOR SCHEDULE FOR NEW
STOREFRONT.
20 REMOVE 100'-0" LONG X 12'-0" WIDE RAMP AND 8'-0" WIDE SIDEWALKS ON THE NORTH AND SOUTH SIDES OF THE RAMP IN THEIR ENTIRETY. SAWCUT SLAB AT CURB TO ALLOW FOR CLEAN JOINT FOR
NEW SIDEWALK.
21 SALVAGE DOOR, TRIM AND FRAME FOR POTENTIAL REINSTALLATION OR OTHER WOOD FRAME
REPAIRS.
22 REMOVE AND SALVAGE DOOR FOR FUTURE REINSTALLATION. KEEP WOOD FRAMES IN PLACE.
23 REMOVE ALL PREFAB OFFICE PARTITIONS IN ITS ENTIRETY.
24 REMOVE ALL CMU WALL WITH GYP. BOARD FINISH PARTITIONS IN ITS ENTIRETY
25 REMOVE ALL INSULATED STUD WALL WITH GYP. BOARD FINISH PARTITIONS IN ITS ENTIRETY.
26 REMOVE ALL CMU WALL PARTITIONS IN ITS ENTIRETY.
27 REMOVE ALL CHAIN LINK PARTITIONS IN ITS ENTIRETY.
28 REMOVE ALL INSULATED METAL PANEL WITH TILE WAINSCOATING PARTITIONS IN ITS ENTIRETY.
29 REMOVE ALL BRICK WALL IN ITS ENTIRETY.
30 REMOVE ALL INSULATED METAL PANEL PARTITIONS IN ITS ENTIRETY.
31 REMOVE ALL STUD WITH PLASTIC & WIRE PARTITIONS IN ITS ENTIRETY.
32 REMOVE ALL BRICK WALL WITH PLASTER FINISH PARTITIONS IN ITS ENTIRETY.
33 REMOVE ALL RESTROOM PARTITIONS IN ITS ENTIRETY.
34 REMOVE ALL INSULATED STUD WALL WITH GYP. BOARD & METAL PANEL FINISH PARTITIONS IN ITS
ENTIRETY.
35 REMOVE MEZZANINE FRAMING AND FINISH IN ITS ENTIRETY.
36 REMOVE WALL FINISH TO MASONRY SUBSTRATE.
37 REMOVE CARPET AND RUBBER WALL BASE IN ITS ENTIRETY.
38 REMOVE TERRACOTTA AND COVE BASE IN ITS ENTIRETY.
39 REMOVE VCT AND RUBBER WALL BASE IN ITS ENTIRETY.
40 REMOVE ACT ASSEMBLY IN ITS ENTIRETY.
41 REMOVE CERAMIC TILE AND COVE BASE IN ITS ENTIRETY.
42 REMOVE RUBBER WALL BASE IN ITS ENTIRETY.
Revisions: Date:
Revision 1 1/27/2021
UP
/A 34-AD-103/A 34-AD-103
PLUMBING STORAGE
E051
ELEV EQUIP
E056
OFFICE
E078
FREEZER
E075
WAITING RM
E076
STORAGE
E077
REFR
E073
FREEZER
E079
FREEZER
E082
REFR
E081
FREEZER
E083
REFR
E084
FREEZER
E085
MASON SHOP
E080
CORRIDOR
E071
OFFICE
E055
EQUIP REPAIR
E054
MECH REF
E074
REFR
E072
UNEXCAVATED
E033
REFR
E191
UNEXCAVATED
E034
HATCH LEGEND
REFERENCE ASSOCIATED KEYNOTE 8 FOR MORE INFORMATION
EXISTING WALL / PARTITION TO REMAIN
EXISTING LOAD-BEARING WALL / PARTITION TO REMAIN
AREA NOT INCLUDED IN SCOPE OF WORK
NEW WALL / PARTITION CONSTRUCTION
LINETYPE LEGEND
LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN
HEAVY DASHED LINE INDICATES EXISTING ELEMENT TO BE
REMOVED IN ITS ENTIRETY
SHEET KEYNOTES
GENERAL NOTES
1. REMOVE ENTIRE MECHANICAL, ELECTRICAL, PLUMBING, TELECOMMUNICATIONS (MEP/T)
SYSTEMS AS NOTED.
2. REMOVE ALL INTERIOR PARTITIONS AND ASSOCIATED DOORS IN THEIR ENTIRETY AS NOTED.
3. REMOVE ALL INTERIOR CEILINGS AND ASSOCIATED LIGHT FIXTURES AND CEILING DIFFUSERS
IN THEIR ENTIRETY AS NOTED.
4. ANY DEMOLITION OR DISTURBANCE TO BLOCK WALLS CONTAINING ASBESTOS ARE
REQUIRED TO BE REMOVED BY THE ABATEMENT CONTRACTOR.
5. REMOVE AND DISPOSE OF ALL ASBESTOS-CONTAINING INSULATION IN WALLS AND ABOVE
CEILINGS.
6. REMOVE AND DISPOSE OF ALL ASBESTOS-CONTAINING MASTIC ON CORK INSULATION AND
ORIGINAL COOLER WALLS/CEILINGS.
7. SALVAGE DOOR, TRIM AND FRAME FOR POTENTIAL REINSTALLATION OR OTHER WOOD
FRAME REPAIRS WHEREVER INDICATED ON AREA DEMOLITION DRAWINGS.
Drawing Title
Approved: Associate Director
Project Title
Date
Location
Checked
Building Number
Project Number:
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
Dwg. of o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Veterans
Health
Administration Approved: Chief of Staff
Approved: Infection Control
Approved: Chief Engineer
Approved: Safety Officer
Approved: Chief, Police & Security
GHD Cons Services, Inc.
Fire Protection Engineer 222 S. Church St. #400, Charlotte, NC 28202
Phone: 704-342-4910 www.ghd.com
GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211
Phone: 316-265-9367 www.glmv.com
AME Consulting Engineers MEP Engineers 705 E. Morehead St., Charlotte, NC 28202
Phone: 704-295-4263 www.ame-pc.com
STRATA Architecture, Inc.
Historic Preservation Architect 1701 Oak Street, Suite 100, Kansas City, MO 64108
Phone: 816-474-0900 www.strata-arch.com
Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603
Phone: 828-315-9962 www.atriaxgroup.com
B
KEYPLAN
TRUE NORTH
/1
/2
:2
:4
P M
B
IM
/1
.1
M tn
H o m e V
A
B ld g
R e n o v
-9
.1
.A rc h
-M tn
H o m e .r v t
34-AD-104
DEMOLITION FLOOR PLAN - LOWER
LEVEL FLOOR AREA B
Renovate Building 34 to Correct FCA Deficiencies
James H. Quillen VAMC Mountain Home, TN
621-18-102
07/24/2020 FAB JSR 11 149
0 8' 16'4'1/8" = 1'-0"A
LOWER LEVEL DEMOLITION PLAN AREA B
PLAN NORTH
1 EXISTING ELEVATOR EQUIPMENT ROOM AND ELEVATOR TO REMAIN
2 EXISTING ELECTRICAL ROOM TO REMAIN OPERATIONAL. REF. ELECTRICAL DRAWINGS FOR EXITING
ELECTRICAL EQUIPMENT TO REMAIN.
3 EXISTING HVAC ROOM TO REMAIN OPERATIONAL. REF. MECHANICAL DRAWINGS FOR EXISTING
EQUIPMENT TO REMAIN
4 EXISTING TRANS VAULT TO REMAIN OPERATIONAL. REF. ELECTRICAL DRAWINGS FOR EXISTING
EQUIPMENT TO REMAIN.
5 EXISTING LOAD BEARING WALL TO REMAIN
6 EXISTING MECHANICAL ROOM TO REMAIN OPERATIONAL. NO DEMO WORK TO BE DONE.
8 DEMO EXISTING FLOOR SLAB AND STRUCTURAL SUPPORT IN THEIR ENTIRETY, AS SHOWN WITHIN
HATCHED AREA. PREP FLOOR OPENING FOR NEW CONCRETE INFILL
9 EXISTING PLASTER CEILING TO REMAIN. PATCH/REPAIR AS REQUIRED.
10 EXISTING SPIRAL STAIR TO REMAIN. PATCH/REPAIR AS REQUIRED.
11 REMOVE EXISTING LOCKERS IN THEIR ENTIRETY. VA TO REMOVE ALL FURNITURE AND EQUIPMENT
UNLESS OTHERWISE NOTED.
12 EXISTING EXTERIOR DOOR TO REMAIN. REPAIR/REPLACE WEATHER SEALS AND THRESHOLD AS
NEEDED.
13 REMOVE ALL EXISTING REFRIGERATOR AND ASSOCIATED COMPONENTS IN THEIR ENTIRETY.
14 EXISTING INTERIOR DOOR TO REMAIN
15 EXISTING STAIR TO REMAIN
16 EXISTING PAINT BOOTH TO REMAIN
17 REMOVE DOOR AND FRAME IN THEIR ENTIRETY. SALVAGE DOOR AND FRAME TO BE RETURNED TO
VA.
18 REMOVE EXTERIOR DOOR AND FRAME IN THEIR ENTIRETY. SALVAGE DOOR AND FRAME TO BE
RETURNED TO VA. SEE IMPROVEMENT PLANS AND DOOR SCHEDULE FOR NEW DOOR.
19 REMOVE EXTERIOR STOREFRONT AND FRAME IN THEIR ENTIRETY. SALVAGE STOREFRONT AND
FRAME TO BE RETURNED TO VA. SEE IMPROVEMENT PLANS AND DOOR SCHEDULE FOR NEW
STOREFRONT.
20 REMOVE 100'-0" LONG X 12'-0" WIDE RAMP AND 8'-0" WIDE SIDEWALKS ON THE NORTH AND SOUTH SIDES OF THE RAMP IN THEIR ENTIRETY. SAWCUT SLAB AT CURB TO ALLOW FOR CLEAN JOINT FOR
NEW SIDEWALK.
21 SALVAGE DOOR, TRIM AND FRAME FOR POTENTIAL REINSTALLATION OR OTHER WOOD FRAME
REPAIRS.
22 REMOVE AND SALVAGE DOOR FOR FUTURE REINSTALLATION. KEEP WOOD FRAMES IN PLACE.
23 REMOVE ALL PREFAB OFFICE PARTITIONS IN ITS ENTIRETY.
24 REMOVE ALL CMU WALL WITH GYP. BOARD FINISH PARTITIONS IN ITS ENTIRETY
25 REMOVE ALL INSULATED STUD WALL WITH GYP. BOARD FINISH PARTITIONS IN ITS ENTIRETY.
26 REMOVE ALL CMU WALL PARTITIONS IN ITS ENTIRETY.
27 REMOVE ALL CHAIN LINK PARTITIONS IN ITS ENTIRETY.
28 REMOVE ALL INSULATED METAL PANEL WITH TILE WAINSCOATING PARTITIONS IN ITS ENTIRETY.
29 REMOVE ALL BRICK WALL IN ITS ENTIRETY.
30 REMOVE ALL INSULATED METAL PANEL PARTITIONS IN ITS ENTIRETY.
31 REMOVE ALL STUD WITH PLASTIC & WIRE PARTITIONS IN ITS ENTIRETY.
32 REMOVE ALL BRICK WALL WITH PLASTER FINISH PARTITIONS IN ITS ENTIRETY.
33 REMOVE ALL RESTROOM PARTITIONS IN ITS ENTIRETY.
34 REMOVE ALL INSULATED STUD WALL WITH GYP. BOARD & METAL PANEL FINISH PARTITIONS IN ITS
ENTIRETY.
35 REMOVE MEZZANINE FRAMING AND FINISH IN ITS ENTIRETY.
36 REMOVE WALL FINISH TO MASONRY SUBSTRATE.
37 REMOVE CARPET AND RUBBER WALL BASE IN ITS ENTIRETY.
38 REMOVE TERRACOTTA AND COVE BASE IN ITS ENTIRETY.
39 REMOVE VCT AND RUBBER WALL BASE IN ITS ENTIRETY.
40 REMOVE ACT ASSEMBLY IN ITS ENTIRETY.
41 REMOVE CERAMIC TILE AND COVE BASE IN ITS ENTIRETY.
42 REMOVE RUBBER WALL BASE IN ITS ENTIRETY.
Revisions: Date:
Revision 1 1/27/2021
DN
DN
DN
DN
F E
FE
F E
DN
UP
/A 34-AD-106/A 34-AD-106
18 18 18
22 22
17 17
40 40
34-AD-105
Sim
404040
41 41
HATCH LEGEND
REFERENCE ASSOCIATED KEYNOTE 8 FOR MORE INFORMATION
EXISTING WALL / PARTITION TO REMAIN
EXISTING LOAD-BEARING WALL / PARTITION TO REMAIN
AREA NOT INCLUDED IN SCOPE OF WORK
NEW WALL / PARTITION CONSTRUCTION
LINETYPE LEGEND
LIGHT THIN LINE INDICATES EXISTING ELEMENT TO REMAIN
HEAVY DASHED LINE INDICATES EXISTING ELEMENT TO BE
REMOVED IN ITS ENTIRETY
STORAGE
E145
HAC CLOSET
E146
STORAGE
E106
STOR
E118
STOR
E119
CARP STOR
E113
OFFICE
E115
LOUNGE
E114
SHEET METAL SHOP
E111
CARPENTER SHOP
E110
STORAGE
E112
HAC
E107
ENTRANCE STORE
E109
CLOSET
E120
MUSEUM
E104
ENTRANCE
E105
CORRIDOR
E140
COMM CLOSET
E147
RESTROOM
E102b
INTAKE
E103
CLOSET
E103b
KITCHEN
E116
FOYER
E101
INTAKE
E102
STORAGE
E108
MEN'S
E117
HALL
E141
WOMEN'S
E142
MEN'S
E143
STORAGE
E144
STORAGE
E145
SHEET KEYNOTES
GENERA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .