_29 LNC BD - TECHNOLOGY pt1 (pg 231-235).pdf

PDF 13 MB Posted

Attached to
Leavenworth National Cemetery, Gravesite Expansion
Solicitation number
36C78626B0027
Issued by

About this file

This is a technology coversheet and planning document set for a federal construction project at Leavenworth National Cemetery in Kansas. The document package includes technology design plans, schedules, specifications, and installation guidance for a gravesite expansion project managed by the U.S. Department of Veterans Affairs. The project involves telecommunications infrastructure, security systems, and audiovisual technology installation across a lower level and first level of a new facility. Key technology systems include access control door readers and keypads, intrusion detection equipment (motion detectors and glass break sensors), video surveillance cameras, wireless access points, information outlets, conduit and cable pathways, and a telecommunications room with equipment racks. The technology contractor is responsible for rough-in work including conduit sleeves, backboxes, and cable routing, while the telecommunications contractor handles equipment procurement, cabling terminations, and final installations. All installations must comply with ADA Standards for Accessible Design, with specific mounting heights and accessibility requirements detailed throughout the specifications. The document establishes a matrix of responsibility clearly delineating tasks between the electrical contractor and telecommunications contractor, including provisions for the relocation of existing optical fiber from a maintenance building and coordination with VA Office of Information Technology for equipment removal and replacement. The contract documents are dated June 22, 2026, and reference optional bid number one for the project numbered 897CM3025.

View the file

Other files

File Type Posted
S06_36C78626B0027 Amend. 0002.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_CivilSheets_CG100-CR117_20260916.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_CivilSheets_CD100-CB501_20260916.pdf PDF
S04_Attachment - Site Visit Attendance Roster.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_SurveySheets_V100-V113_20260916.pdf PDF
S02_Attachment - 00 01 10 Table of Contents.pdf PDF
S02_Attachment - Substitution Request - Leavenworth GSE.pdf PDF
S02_Attachment - 00 00 00 Specification Cover.pdf PDF
S02_Attachment - 01 35 26 Safety Requirements.pdf PDF
_31 LNC BD - TECHNOLOGY pt3 FIRE ALARM (pg 241-247).pdf PDF
_11 LNC BD - GRADING DRAINAGE (pg 78-82).pdf PDF
_28 LNC BD - PLUMBING (pg 224-230).pdf PDF
_24 LNC BD - INTERIORS (pg 182-188).pdf PDF
_23 LNC BD - ARCH pt2 (pg 171-181).pdf PDF
_19 LNC BD - SIGNAGE FURNISHINGS pt2 (pg 126-138).pdf PDF
_16 LNC BD - ROADS pt2 (pg 106-113).pdf PDF
_05 LNC BD - DEMOLITION pt1 (pg 22-34).pdf PDF
_07 LNC BD - SITE (pg 41-49).pdf PDF
_02 LNC BD - EX CON pt1 (pg 3-16).pdf PDF
LNC Gravesite Expansion VOL1SPECS wGEOTECH - BD 06-22-2026.pdf PDF
S02_Attachment - Price Schedule Sheet.pdf PDF
_20 LNC BD - PLANTING IRR pt1 (pg 139-149).pdf PDF
_14 LNC BD - EROSION CONTROL pt3 UTIL pt1 (pg 91-98).pdf PDF
_22 LNC BD - ARCH pt1 (pg 159-170).pdf PDF
_09 LNC BD - COLUMBARIUM 3 pt1 (pg 60-69).pdf PDF
_10 LNC BD - COLUMBARIUM 3 pt2 (pg 70-77).pdf PDF
LNC Gravesite Expansion VOL2SPECS wGEOTECH - BD 06-22-2026.pdf PDF
_08 LNC BD - BURIALS (pg 50-59).pdf PDF
_30 LNC BD - TECHNOLOGY pt2 (pg 236-240).pdf PDF
_03 LNC BD - EX CON pt2 (pg 17).pdf PDF
S02_Attachment - Statement of Work.pdf PDF
S02_Attachment - Davis-Bacon Act Poster.pdf PDF
_26 LNC BD - ELECTRICAL (pg 201-214).pdf PDF
_25 LNC BD - STRUCTURAL (pg 189-200).pdf PDF
_21 LNC BD - IRR pt2 (pg 150-158).pdf PDF
_18 LNC BD - SIGNAGE FURNISHINGS pt1 (pg 118-125).pdf PDF
_12 LNC BD - EROSION CONTROL pt1 (pg 83-86).pdf PDF
_13 LNC BD - EROSION CONTROL pt2 (pg 87-90).pdf PDF
_17 LNC BD - ROADS pt3 (pg 114-117).pdf PDF
_04 LNC BD - GEOTECH (pg 18-21).pdf PDF
S02_Attachment - Wage Determination Heavy.pdf PDF
S02_Attachment - Wage Determination Building.pdf PDF
S02_Attachment - Limitations on Subcontracting Cert.docx DOCX document
S02_Attachment - DOL Payroll Form.pdf PDF
_15 LNC BD - UTIL pt2 ROADS pt1 (pg 99-105).pdf PDF
_06 LNC BD - DEMO pt2 OPERATIONS (pg 35-40).pdf PDF
_27 LNC BD - MECHANICAL (pg 215-223).pdf PDF
_01 LNC BD - GENERAL (pg 1-2).pdf PDF
S02_Attachment - Standard Form 1413.pdf PDF
S02_36C78626B0027 Solicitation.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNOLOGY ABBREVIATION KEY

MAIN CROSS-CONNECTMC-#

TELECOMMUNICATIONS ROOMTR-#

ABOVE FINISHED FLOORAFF

BELOW FINISHED CEILINGBFC

CONDUITC

SIMILARSIM

TYPICALTYP

MOUNTING HEIGHT ABOVE FINISHED FLOOR+#

JUNCTION BOXJ-BOX

ABBR: DESCRIPTION:

UNLESS OTHERWISE NOTEDUON

FIELD OF VIEWFOV

DOUBLE POLE DOUBLE THROWDPDT

PAN TILT ZOOMPTZ

POWER OVER ETHERNETPOE

ABOVE FINISHED GRADEAFG

DELAYED EGRESSDE

GOVERNMENT FURNISHED GOVERNMENT INSTALLEDGFGI

TECHNOLOGY GENERAL NOTES:

1. ##-###-# INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT

LIST ABBREVIATION"

2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL

DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.

TECHNOLOGY MOUNTING SUBSCRIPT KEY:

A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH

H MOUNT ORIENTED HORIZONTALLY

L MOUNT IN CASEWORK

M MOUNT IN MODULAR FURNITURE

S MOUNT IN SURFACE RACEWAY

A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.

3. REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION

AND ITEMS.

4. REFER TO DIAGRAMS ON SHEET(S): T500.

1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR

ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS

ON THIS PAGE FOR ADDITIONAL INFORMATION.

2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.

UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN

MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON

BUILDING STRUCTURE.

3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM

OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE

OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE

ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.

4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING

THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION

LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.

5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO

ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION

DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN

ADVANCE BY THE OTHER CONTRACTOR.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL

BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF

THROUGH-PENETRATION FIRESTOPS. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.

8. THE TECHNOLOGY CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF

THE CEILINGS, CEILING TILES, AND CEILING GRID ASSOCIATED WITH THE AREAS OF WORK

BY ALL CONTRACTORS.

9. ALL LADDER RACK SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO SPECIFICATION

SECTIONS FOR APPROVED MANUFACTURERS AND INSTALLATION REQUIREMENTS.

10. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE

WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES

DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE

RATING, AND FINISH.

11. FLUSH MOUNT ALL TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR (CENTERLINE

DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE MOUNTED

WHEN CONDUIT IS SPECIFIED EXPOSED.

12. MOUNT BACKBOXES FLUSH WITH WALL. ALL BACKBOX HEIGHTS ARE TO CENTERLINE

DIMENSION, UNLESS OTHERWISE NOTED.

13. PROVIDE RACEWAY AND BOXES LISTED FOR THE INSTALLED ENVIRONMENT. SEAL

RACEWAY AND BOX FROM WATER AND MOISTURE AT TRANSITION BETWEEN DIFFERENT

ENVIRONMENTAL CONDITIONS SUCH AS INTERIOR/EXTERIOR, TEMPERATURE CHANGES,

ETC.

TECHNOLOGY INSTALLATION NOTES:

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

VIEW NAME

1/8" = 1'-0"

M101

SIMSIM

INDICATES SIMILAR DETAIL REFERENCED

IN MULTIPLE LOCATIONS

LEVEL NAME

10'-0" HEIGHT ABOVE

PROJECT 0'-0"

1 KEYNOTE: INDICATES NOTE USED TO

DESCRIBE ADDITIONAL INFORMATION

ABOUT WORK REQUIRED, SPECIFIC

TO THE SHEET AND/OR DETAIL

N

O R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE AND TAG KEY:

NEW WORK BY THIS CONTRACTOR (WIDE LINE)

EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)

HALFTONING DOES NOT MODIFY SCOPE.

'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING

TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL

INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST

INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL

T101

NEW

EXISTING TO BE REMOVED (SHORT DASHED PATTERN)

NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

EXISTING

EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)

EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

M

A X

20" MAX.

M

A X

20"-25" MAX.

M

A X

M

IN

. 4

M

A X

M

A X

10" MAX. 10"-24" MAX.

ADA STANDARDS - FRONT ACCESS

ADA STANDARDS FOR ACCESSIBLE DESIGN

INSTALL ABOVE COUNTER

DEVICE AT 44" ABOVE

FINISHED FLOOR.

INSTALL ABOVE COUNTER

DEVICE AT 40" ABOVE

FINISHED FLOOR.

INSTALL DEVICE AT 18"

ABOVE FINISHED FLOOR.

ADA STANDARDS - SIDE ACCESS

INSTALL DEVICE AT 44"

ABOVE FINISHED FLOOR.

INSTALL DEVICE AT 42"

ABOVE FINISHED FLOOR.

TECHNOLOGY SYMBOL LIST

SYMBOL TAG

EQUIPMENT LIST

ABBREVIATION

DESCRIPTION

DBDB DETENTION DOORBELL BUTTON (WALL) EXISTING

RME NA

ACCESS CONTROL DOOR (READER / MOTION REX /

ELECTRONIC LOCKING HARDWARE)

R1 AC-R1-W SECURITY CREDENTIAL READER (WALL) TYPE 1

K SECURITY KEY SWITCH (WALL) EXISTING

A AL1 AC-AA-1 INTRUSION DETECTION AUDIBLE ALARM (WALL)

G GB1 ID-GB1-C INTRUSION DETECTION GLASS BREAK (CEILING)

K1 AC-K1-W INTRUSION DETECTION KEYPAD (WALL) TYPE 1

M MD1 ID-MD1-C INTRUSION DETECTION MOTION DETECTOR (CEILING)

M

INTRUSION DETECTION MOTION DETECTOR (WALL)

EXISTING

C# C2-WAP SC-IO-C INFORMATION OUTLET (CEILING)

C# C2 SC-IO-F INFORMATION OUTLET CONNECTION IN FLOOR BOX

C# C2 SC-IO-W INFORMATION OUTLET (WALL)

C2-M SC-IO-W INFORMATION OUTLET (WALL)

INFORMATION OUTLET (WALL) EXISTING

RI RI SC-RI-W INFORMATION OUTLET ROUGH-IN (WALL)

W W SC-IO-W INFORMATION OUTLET WALL PHONE (WALL)

WAP

WIRELESS ACCESS POINT WITH ENCLOSURE (CEILING)

EXISTING

CM-1 VS-CM-1

VIDEO SURVEILLANCE CAMERA SINGLE LENS FOV

(CEILING/HORIZONTAL SURFACE)

VIDEO SURVEILLANCE CAMERA 360° FOV

(CEILING/HORIZONTAL SURFACE) EXISTING

CM-4 VS-CM-4

VIDEO SURVEILLANCE CAMERA 360° FOV

(WALL/VERTICAL SURFACE)

TECHNOLOGY SYMBOL LIST GENERAL NOTES:

1. "C#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO DATA

CONNECTION SCHEDULE ON T600 FOR ADDITIONAL INFORMATION.

2. REFER TO ACCESS CONTROL DOOR TYPE SCHEDULE ON T600 FOR ADDITIONAL

INFORMATION.

3. "CM-#" ON FLOOR PLANS INDICATES CAMERA TYPE AND IS ASSOCIATED WITH THE

CORRESPONDING "VS-CM-#" EQUIPMENT SCHEDULE ABBREVIATION.

LADDER RACKWIDTH X HEIGHT

DIAMETERø C CONDUIT

CONDUIT DOWN

CONDUIT UP OR UP/DOWN

CONDUIT SLEEVE

CONTINUATION

PATHWAY SYMBOL LIST:

SYMBOL DESCRIPTION

TECHNOLOGY SHEET INDEX

T000 TECHNOLOGY COVERSHEET

T001 SITE - TECHNOLOGY

T002 LOWER LEVEL DEMOLITION PLAN - TECHNOLOGY

T003 FIRST LEVEL DEMOLITION PLAN - TECHNOLOGY

T100 LOWER LEVEL PLAN - TECHNOLOGY

T101 FIRST LEVEL PLAN - TECHNOLOGY

T300 TECHNOLOGY ENLARGED PLANS

T400 TECHNOLOGY DETAILS

T401 TECHNOLOGY DETAILS

T402 TECHNOLOGY DETAILS

T500 TECHNOLOGY DIAGRAMS

T600 TECHNOLOGY SCHEDULES

GRAND TOTAL: 12

SUGGESTED MATRIX OF RESPONSIBILITY

ITEM: SHOWN ON:

FURNISHED

BY:

INSTALLED

BY: NOTES:

TECHNOLOGY ROUGH-IN, REFER TO

TECHNOLOGY EQUIPMENT SCHEDULE

AND SPECIFICATIONS FOR DEFINITION

T-SERIES E.C. E.C. 3. 4.

INFORMATION OUTLET FACEPLATES,

JACKS, AND TERMINATIONS

T-SERIES T.C. T.C.

CONDUIT SLEEVES (WHEN SHOWN ON

DRAWINGS)

T-SERIES E.C. E.C.

CONDUIT SLEEVES (NOT SHOWN BUT

REQUIRED FOR PROPER INSTALLATION

OF SYSTEM)

N/A T.C. T.C. 2. 4.

TELECOMMUNICATION SYSTEMS

ROUGH-IN

T-SERIES E.C. E.C. 1.

TELECOMMUNICATION EQUIPMENT,

CABLING, AND TERMINATIONS

T-SERIES T.C. T.C.

LADDER RACK T-SERIES T.C. T.C. 5.

GROUNDING LUGS ON TECHNOLOGY

EQUIPMENT

T-SERIES T.C. E.C. 6.

BONDING SYSTEM FOR TECHNOLOGY

SYSTEM, REFER TO SPECIFICATION

SECTION 27 05 26 FOR DEFINITION

T-SERIES E.C. E.C. 7. 8.

CONNECTION OF TECHNOLOGY

BONDING SYSTEM TO THE ELECTRICAL

GROUND SYSTEM

T-SERIES E.C. E.C.

LINE VOLTAGE POWER (+120V OR

GREATER)

E-SERIES E.C. E.C.

LINE VOLTAGE POWER (NOT SHOWN

BUT REQUIRED FOR PROPER

INSTALLATION OF SYSTEM)

N/A T.C. E.C. 2. 4.

LINE VOLTAGE POWER FOR DOOR

HARDWARE POWER SUPPLIES

ARCH SPEC E.C. E.C.

LOW VOLTAGE CABLING FOR

TECHNOLOGY SYSTEMS

T-SERIES T.C. T.C.

CABLE HANGERS AND SUPPORTS OR

OTHER CABLE ROUTING METHODS

(OTHER THAN CONDUIT AND CABLE

TRAY)

T-SERIES T.C. T.C. 5.

SUGGESTED MATRIX OF RESPONSIBILITY NOTES

1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION

OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR

ADDITIONAL INFORMATION.

2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL

REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE

MANUFACTURERS.

3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS

INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE

CONTRACT DOCUMENTS.

4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF

THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM

CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED

IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.

5. UNLESS TRADE RULES DICTATE OTHERWISE.

6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR

INSTALLATION IN THE FIELD.

7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE

BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.

8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN

IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW

DIAGRAM.

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:4

P

M

T000

TECHNOLOGY COVERSHEET

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

Revisions: Date:

VA

F

O R

M

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-000

CEMETERY RD

L P

L P

L P

L P

Temporary Trailer

MH/7

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

P

M

T001

SITE - TECHNOLOGY

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

N O R

HT

1" = 20'-0"1

SITE - TECHNOLOGY

GENERAL SHEET NOTES:

1. THE LOCATION OF EXISTING COMMUNICATIONS MANHOLES SHOWN

ON THIS SHEET ARE APPROXIMATE. CONTRACTOR SHALL FIELD

VERIFY THE LOCATION OF ALL EXISTING CONDUITS AND MANHOLES

AND OTHER UTILITIES PRIOR TO THE INSTALLATION OF NEW WORK

SHOWN ON THIS SHEET.

2. CONTRACTOR SHALL INCLUDE IN THEIR BID ANY REMOVAL AND

REPLACEMENT OF EXISTING SIDEWALK, PAVEMENT, GRASS,

SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BY THE

INSTALLATION OF THE NEW WORK SHOWN IN THIS DRAWING. IF

TREES ARE REQUIRED TO BE REMOVED THE CONTRACTOR SHALL

CONTACT THE VA AND DISCUSS OPTIONS PRIOR TO CUTTING DOWN

ANY TREE OR SHRUB OVER 5' IN HEIGHT.

3. NO ADDITIONAL COST SHALL BE APPROVED FOR PLACING

CONDUITS DEEPER THAN REQUIRED MINIMUM DEPTH TO AVOID

EXISTING UTILITIES.

4. COORDINATE ALL UTILITY WORK WITH FINAL CIVIL DRAWINGS.

5. NUMBER OF BENDS IN A SINGLE CONDUIT RUN SHALL NOT EXCEED

180 DEGREES AND NO MORE THAN TWO 90 DEGREE BENDS.

6. SLOPE CONDUIT RUNS FOR DRAINAGE TOWARD THE MANHOLES

AND AWAY FROM BUILDING WITH A SLOPE OF APPROXIMATELY 3-

INCHES PER 100 FEET.

7. PLUG AND SEAL EMPTY SPARE CONDUITS ENTERING BUILDINGS.

8. DRAWINGS ARE FOR REFERENCE ONLY. REFER TO CIVIL DRAWINGS

FOR ADDITIONAL INFORMATION.

9. ALL UNDERGROUND CONDUITS SHALL BE ENCASED IN CONCRETE.

10. CONTRACTOR SHALL SUBMIT PROPOSED CONDUIT PLAN TO A/E

FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION.

11. VIDEO SURVEILLANCE CAMERAS SHOWN ON THIS SHEET ARE FOR

REFERENCE ONLY. REFER TO 1/T101 FOR ADDITIONAL

INFORMATION.

KEYNOTES:

1. INSTALL 2" CONDUIT FROM TEMP TRAILER TO

TELECOMMUNICATIONS MANHOLE (MH/7). MANHOLE TO BE

INSTALLED IN MAINTENANCE BUILDING PROJECT. COORDINATE

WITH TRAILER MANUFACTURER ON FINAL LOCATION OF CONDUIT.

Revisions: Date:

VA

F

O

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-001

H

C

G

F

E

D

3 4 5

4.1 5.1

3.1

D.1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

P

M

T002

LOWER LEVEL DEMOLITION PLAN -

TECHNOLOGY

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

LOWER LEVEL DEMOLITION PLAN - TECHNOLOGY

KEYNOTES:

1. EXISTING TELECOMMUNICATIONS CABINET.

REMOVE CABINET AND ALL CABLING BACK TO

ITS SOURCE. COORDINATE WITH VA OIT FOR

REMOVAL OF IT EQUIPMENT.

2. EXISTING SERVICE PROVIDER DEMARCATION

POINT.

3. EXISTING FIBER PANEL TO REMAIN.

4. EXISTING CONDUIT FOR SERVICE PROVIDER

CABLING.

5. EXISTING SERVICE PROVIDER CABLING TO

REMAIN.

6. EXISTING OPTICAL FIBER TO EXISTING

MAINTENANCE BUILDING. REMOVE FIBER ONCE

NEW MAINTENANCE BUILDING HAS BEEN

CONSTRUCTED AND FULLY OPERATIONAL.

Revisions: Date:

VA

F

O

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-002

D B

D B

WAP

WAP

M K

M

H

C

G

F

E

D

3 4 5

4.1 5.1

3.1

D.1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

P

M

T003

FIRST LEVEL DEMOLITION PLAN -

TECHNOLOGY

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

FIRST LEVEL DEMOLITION PLAN - TECHNOLOGY

SHEET NOTES:

1. REMOVE ALL CABLING BACK TO ITS SOURCE.

KEYNOTES:

1. EXISTING DISPLAY. REMOVE DISPLAY AND

MOUNT AND RETURN TO GOVERNMENT.

REMOVE ALL CABLING BACK TO SOURCE.

2. PLUG-IN DOOR BELL RECEIVER. REMOVE AND

REPLACE DEVICE. REFER TO T101 FOR

ADDITIONAL INFORMATION.

3. VIDEO SURVEILLANCE SERVER. REMOVE AND

RETURN TO GOVERNMENT. REMOVE ALL

CABLING BACK TO SOURCE

4. REMOVE DOOR POSITION SWITCH AND CABLING

BACK TO SOURCE.

5. WIRELESS DOOR BELL AND CHIME. REMOVE

AND REPLACE. REFER TO T101 FOR ADDITIONAL

INFORMATION.

6. RADIO ANTENNA. ANTENNA AND EQUIPMENT TO

REMAIN.

Revisions: Date:

VA

F

O

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-003

M

C2-WAP

R1

H

C

G

F

E

D

B

A

2.1

4 5

4.1 5.1

3.1

D.1

ELECTRICAL

B04

TR

B03

BASEMENT

B02

BASEMENT

B01

B02A

B04A

B02B

B01A

B03A

STAIRS

B05

T300

T300

CM-1

01-01

CM-1

01-02

RME

MD1

RME TR-1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

P

M

T100

LOWER LEVEL PLAN -

TECHNOLOGY

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

LOWER LEVEL PLAN - TECHNOLOGY

SHEET NOTES:

1. ALL CABLING SHALL ROUTE TO

TELECOMMUNICATIONS ROOM B03.

KEYNOTES:

1. EXISTING SERVICE PROVIDER EQUIPMENT.

2. NEW SECURITY GATE. REFER TO ARCHITECT

DRAWINGS FOR ADDITIONAL INFORMATION.

3. CONTRACTOR TO RELOCATE EXISTING

OPTICAL FIBER FROM NEW MAINTENANCE

BUILDING, INSTALLED UNDER SEPARATE

PROJECT. RELOCATE FIBER AND FIBER

OPTICAL PANEL TO NEW RACK IN NEW

TELECOMMUNICATIONS ROOM. CONTRACTOR

SHALL COORDINATE WITH VA OIT WHEN FIBER

RELOCATION CAN OCCUR.

Revisions: Date:

VA

F

O

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-100

File details come from the government source that posted it. Updated .