_17 LNC BD - ROADS pt3 (pg 114-117).pdf

PDF 7 MB Posted

Attached to
Leavenworth National Cemetery, Gravesite Expansion
Solicitation number
36C78626B0027
Issued by

About this file

Summary of Bid Documents - Leavenworth National Cemetery Gravesite Expansion

These are bid documents for Phase 1 road improvements at Leavenworth National Cemetery in Leavenworth, Kansas, issued by the U.S. Department of Veterans Affairs, Office of Design and Construction Services. The project (897CM3025) involves comprehensive road reconstruction and utility work across multiple cemetery roadways. The Architect/Engineer of Record is Anderson Engineering of Minnesota, LLC (Project #18704), with cost estimating services provided by OCMI.

The scope of work includes pavement removal and replacement on Road A and Cemetery Road, with full-depth pavement and curb removal in all designated areas. Work encompasses new heavy-duty concrete and bituminous pavement installation, curb and gutter construction (barrier curb and roll curb configurations), drainage infrastructure including catch basins and storm-drain systems (18-inch and 15-inch HDPE storm drain pipes), and superelevated and crowned road sections with varying slopes. The project involves multiple vertical curves with specific elevation data, stations ranging from 10+00 to 28+50, and requires contractors to match existing roadway widths, curb radii, and pavement edge elevations. Contractors must remove tree roots to 2 feet beyond the back of curb, confirm existing utility locations prior to construction, verify actual project limits on-site, and notify the Government's Representative (COR/RE) immediately of any discrepancies. The documents include detailed plan and profile sheets showing existing and proposed grades, utility connections, and construction limits across the cemetery property.

View the file

Other files

File Type Posted
S06_36C78626B0027 Amend. 0002.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_SurveySheets_V100-V113_20260916.pdf PDF
S02_Attachment - 00 01 10 Table of Contents.pdf PDF
S02_Attachment - Substitution Request - Leavenworth GSE.pdf PDF
S02_Attachment - 00 00 00 Specification Cover.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_CivilSheets_CG100-CR117_20260916.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_CivilSheets_CD100-CB501_20260916.pdf PDF
S04_Attachment - Site Visit Attendance Roster.pdf PDF
S02_Attachment - 01 35 26 Safety Requirements.pdf PDF
_20 LNC BD - PLANTING IRR pt1 (pg 139-149).pdf PDF
_14 LNC BD - EROSION CONTROL pt3 UTIL pt1 (pg 91-98).pdf PDF
_22 LNC BD - ARCH pt1 (pg 159-170).pdf PDF
_09 LNC BD - COLUMBARIUM 3 pt1 (pg 60-69).pdf PDF
_10 LNC BD - COLUMBARIUM 3 pt2 (pg 70-77).pdf PDF
LNC Gravesite Expansion VOL2SPECS wGEOTECH - BD 06-22-2026.pdf PDF
_08 LNC BD - BURIALS (pg 50-59).pdf PDF
_30 LNC BD - TECHNOLOGY pt2 (pg 236-240).pdf PDF
_03 LNC BD - EX CON pt2 (pg 17).pdf PDF
S02_Attachment - Statement of Work.pdf PDF
S02_Attachment - Davis-Bacon Act Poster.pdf PDF
_26 LNC BD - ELECTRICAL (pg 201-214).pdf PDF
_29 LNC BD - TECHNOLOGY pt1 (pg 231-235).pdf PDF
_25 LNC BD - STRUCTURAL (pg 189-200).pdf PDF
_21 LNC BD - IRR pt2 (pg 150-158).pdf PDF
_18 LNC BD - SIGNAGE FURNISHINGS pt1 (pg 118-125).pdf PDF
_12 LNC BD - EROSION CONTROL pt1 (pg 83-86).pdf PDF
_13 LNC BD - EROSION CONTROL pt2 (pg 87-90).pdf PDF
_04 LNC BD - GEOTECH (pg 18-21).pdf PDF
S02_Attachment - Wage Determination Heavy.pdf PDF
S02_Attachment - Wage Determination Building.pdf PDF
S02_Attachment - Limitations on Subcontracting Cert.docx DOCX document
S02_Attachment - DOL Payroll Form.pdf PDF
_31 LNC BD - TECHNOLOGY pt3 FIRE ALARM (pg 241-247).pdf PDF
_11 LNC BD - GRADING DRAINAGE (pg 78-82).pdf PDF
_28 LNC BD - PLUMBING (pg 224-230).pdf PDF
_24 LNC BD - INTERIORS (pg 182-188).pdf PDF
_23 LNC BD - ARCH pt2 (pg 171-181).pdf PDF
_19 LNC BD - SIGNAGE FURNISHINGS pt2 (pg 126-138).pdf PDF
_16 LNC BD - ROADS pt2 (pg 106-113).pdf PDF
_05 LNC BD - DEMOLITION pt1 (pg 22-34).pdf PDF
_07 LNC BD - SITE (pg 41-49).pdf PDF
_02 LNC BD - EX CON pt1 (pg 3-16).pdf PDF
LNC Gravesite Expansion VOL1SPECS wGEOTECH - BD 06-22-2026.pdf PDF
S02_Attachment - Price Schedule Sheet.pdf PDF
_15 LNC BD - UTIL pt2 ROADS pt1 (pg 99-105).pdf PDF
_06 LNC BD - DEMO pt2 OPERATIONS (pg 35-40).pdf PDF
_27 LNC BD - MECHANICAL (pg 215-223).pdf PDF
_01 LNC BD - GENERAL (pg 1-2).pdf PDF
S02_Attachment - Standard Form 1413.pdf PDF
S02_36C78626B0027 Solicitation.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

9 S

F

AS

SI

ST

AN

T

DI

RE

CT

OR

6 S F

PR

OG

RA

M

AN

AL

YS

T

3 S

F

BU

DG

ET

AN

AL

YS

T

8 S

F

OP

ER

AT

IO

NA

L

CT

R

4 S

F

DI

RE

CT

OR

S

F

4A

ST

AF

F

ME

N

S

F

3AST

AF

F W

OM

EN

1 S

F

AD

MI

N

OF

FI

CE

R

6 S

F

MU

LT

IP

UR

PO

SE

RO

OM

S

F

HA

C

1 S

F

ME

NS

3 S

F

W

OM

EN

S

2 S

F

LO

BB

Y

0 S

F

HA

LL

W

AY

S

F

ST

OR

AG

E

3 S F

5c

HA

LL

W

AY

9 S

F

W

OR

KS

TA

TI

ON

S

8 S

F

5b

HA

LL

W

AY

8 S

F

BR

EA

K

RO

OM

8 S

F

4ME

NS

LO

CK

ER

RO

OM

S

F

W

OM

EN

S

LO

CK

ER

RO

OM

DO

W

N

DO

W

N

B6

SS

SS

GS

L

BE

NC

H

BE

NC

H

CO

UN

TE

RT

OP

TV

B6

B6

AE

5b

HA

LL

W

AY

CR

CR

FE

C

FE

C

SECTION

SECTION

42A

SECTION

41A

SECTION

SECTION

CREMAINS

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

9 SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

43A

OBELISK

OFFICERS

SECTION

MA

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

28 SECTION

SECTION

SECTION

SECTION

SECTION

COMMITTAL

SHELTER

FLAG

POLE

ROSTRUM

SECTION

SECTION

SECTION

SECTION

SECTION

53A

SECTION

SECTION

SECTION

SECTION

SECTION

58A

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

72A

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

SECTION

LAKE

JEANNETTE

COMMITTAL

SHELTER

MAIN

ENTRANCE

COMMITTAL

SHELTER

CURRENT

MAINTENANCE

FACILITY

UNDER

CONSTRUCTION

MAINTENANCE

FACILITY

APPROX. EXISTING

RAILROAD GATE ACCESS

VA MEDICAL

CENTER

COLUMBARIUM

COLUMBARIUM

CEMETERY RD

C

EM

ET

ER

Y R

D

CEMETERY RD

CEMETERY RD

COOKE DR

OVERLOOK RD

CEMETERY LP

CEMETERY LP

SINGER RD

RIVERVIEW AVE

S OBELISK RD

CEMETERY ENTRANCE RD

ROAD A

N

0 150' 300'

SCALE:1

PHASE 1 ROAD IMPROVEMENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA

F

O R

M

A

Fi le

P at h:

y

:\1

\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\

_0 sh ee ts \1

_c _r oa ds

_o vr l-p h1

.d w g ed it:

bn or he im s av ed

:6 /1

8/

:3

AM

p lo t:6

/2 2/

:4

PM

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026

Date:

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

897CM3025

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

BID DOCUMENTS

KEY MAP N.T.S.

Office of Design and Construction

Services

BID SUBMITTAL

OF ---

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 CR114

114VBAT

PHASE 1 ROAD IMPROVEMENTS

CR115

CR116

CR117

-1.98%

-4.54%

0.62% -4.81%-3.07%

-5.70%

-2.10% 1.24%

PV

IS

: 1 0+

.8

PV

IE

: 8

.1

PV

IS

: 1

0+

.1

PV

IE

: 8

.1

PV

IS

: 1 0+

.5

PV

IE

: 8

.7

PV

IS

: 1 0+

.5

PV

IE

: 8

.7

PV

IS

: 1 0+

.1

PV

IE

: 8

.6

PV

IS

: 1 1+

.2

PV

IE

: 8

.2

PV

IS

: 1 5+

.4

PV

IE

: 8

.4

PVI STA = 12+54.07

PVI ELEV = 863.80

A.D. = 2.44% K = 41.05

100.00' VC

BV

C

S:

2+

.0

BV

C

E:

.0

EV

C

S:

3+

.0

EV

C

E:

.7

ST

M

H -1

R

IM

.7

IN

V

3.

(1 8"

E

IN

V

3.

(1

8" N

W

C

BM

H -1

R

IM

.0

IN

V

0.

(1 8"

S E)

IN

V

0.

(1

8" N

W

18 '' HDPE ST

18 '' HDPE ST

18 '' HDPE ST

18 '' HDPE ST

C

BM

H -1

R

IM

.2

IN

V

7.

(1 8"

N

IN

V

7.

(1

8" S

E)

C

BM

H -1

R

IM

.6

IN

V

4.

(1 8"

S

IN

V

4.

(1

8" N

E)

C

BM

H -1

R

IM

.1

IN

V

1.

(1 8"

S W

IN

V

0.

(3 6"

N W

IN

V

1.

(1 8"

E

PROPOSED GRADEEXISTING GRADE

C O

2+00

3+

4+00

5+

SIN

G

ER

R

D

ROAD A

FL 877.05

FL 877.54

FL 874.72

FL 874.31

FL 869.54

FL 873.85

FL 874.12

FL 873.18

CBMH-104

CBMH-105

CBMH-106

CB-111

CBMH-113

FES-114 FES-115

CBMH-112

10+0010+00

11+00

12+00

13+00

14+00

15+00

16+00

+0

BP

: 9

+9 9.

PC

: 1

0+

.7

PT: 11+34.25

PC: 13+28.47

L1

L2

C10

C11

ALIGNMENT LINE DATA

LINE #

L1

L2

LENGTH

61.0242

194.2201

BEARING

N7° 54' 27.91"E

N34° 10' 57.89"W

START POINT

(2191712.0938, 360052.7654)

(2191704.1653, 360183.1506)

END POINT

(2191720.4894, 360113.2094)

(2191595.0458, 360343.8191)

ALIGNMENT CURVE DATA

CURVE #

C10

C11

RADIUS

100.00

150.00

LENGTH

73.46

552.12

CHORD DIRECTION

NORTH13.137498WEST

NORTH71.263503EAST

START POINT

(2191720.4894,360113.2094)

(2191595.0458,360343.8191)

END POINT

(2191704.1653,360183.1506)

(2191868.8860,360436.7034)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA

F

O

A

Fi le

P at h:

y

:\1

\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\

_0 sh ee ts \1

_c _r oa ds

_1 ro ad a

.d w bn or av ed

:6 /1

8/

:3 lo t:6

/2 2/

:5

PM

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026

Date:

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

897CM3025

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

BID DOCUMENTS

KEY MAP N.T.S.

Office of Design and Construction

Services

BID SUBMITTAL

OF ---

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 CR115

115VBAT

PLAN & PROFILE - ROAD A (STA.

10+00 - 16+00)

SCALE:2

PROFILE VIEW ROAD A STA. 10+00 - 16+00

H: 1" = 30' V: 1" = 2.5'

N0 30' 60'

SCALE:1

PLAN VIEW ROAD A STA. 10+00 - 16+00

1" = 30'

SEE SHEET CR102

SEE SHEET CR101

SEE SHEET CR101

MATCHLINE - SEE SHEET CR116

IGC

SECTION 75

IGC

SECTION 76

1. VERTICAL PROFILE INFORMATION SHOWN

IN NON-REPLACEMENT AREAS IS FOR

REFERENCE ONLY. ROAD AREAS TO BE

REMOVED ARE INTENDED TO BE REPLACED

TO THE EXISTING VERTICAL DESIGN.

VERTICAL DESIGN DATA HAS BEEN ADDED

FOR CONSTRUCTION PURPOSES.

HOWEVER, THE CONTRACTOR MUST

NOTIFY THE R.E. OF ANY VARIATION FROM

EXISTING THAT MAY ADVERSELY AFFECT

THE DRAINAGE OR IMPACT ADJACENT

AREAS. THE R.E. AND ENGINEER WILL

REVIEW AND MAKE FIELD ADJUSTMENTS IN

THOSE AREAS AS NEEDED PRIOR TO

CONSTRUCTION OF NEW PAVEMENTS.

2. TAPER NEW ROAD EDGE OVER 10' MIN

DISTANCE TO MATCH EXISTING ROAD.

3. CONFIRM LOCATION OF EXIST. UTILITIES

PRIOR TO CONSTRUCTION OR

CONNECTION.

4. SOME MATCH-IN LOCATIONS AND PROJECT

LIMITS SHOWN, ARE UNVERIFIED. ACTUAL

PROJECT LIMITS MUST BE VERIFIED BY

CONTRACTOR. NOTIFY RE IMMEDIATELY IN

THE EVENT OF DISCREPANCY.

5. NEW ROADWAY WIDTHS & CURB RADII,

MUST MATCH EXISTING CONDITIONS.

6. CONTRACTOR MUST MATCH EXISTING

PAVEMENT EDGE ELEVATION WHERE NO

PROPOSED CURB AND GUTTER IS SHOWN

1. BENCHMARK, SEE TOPOGRAPHIC

SURVEY.

2. FULL-DEPTH PAVEMENT & CURB

REMOVAL MUST OCCUR IN ALL AREAS

SHOWN AS RECEIVING NEW PAVEMENT.

3. REMOVE ANY TREE ROOTS TO 2' BEYOND

BACK OF CURB.

GENERAL NOTES

CONTRACTOR NOTES

MATCH EXISTING GRADE AT EXISTING

CATCH BASIN INLET.

CONCRETE VALLEY GUTTER (SEE DETAIL

9/CS501)

SUPERELEVATED ROAD SECTION VARYING

SLOPE (SEE DETAIL 1/CS503)

CROWNED ROAD SECTION VARYING SLOPE

(SEE DETAIL 2/CS503)

BARRIER CURB (SEE DETAIL 6/CS501)

ROLL CURB (SEE DETAIL 7/CS501)

SUPERELEVATED ROAD SECTION (SEE

DETAIL 3/CS503)

KEY NOTES

LEGEND

PROPERTY LIMITS

CONSTRUCTION LIMITS

NEW CURB & GUTTER

ROAD SECTION TRANSTION

2" MILL & OVERLAY EXISTING ASPHALT

PAVEMENT

NEW HEAVY DUTY CONCRETE

PAVEMENT (4/CS501)

NEW BITUMINOUS PAVEMENT (2/CS501)

1.85%

5.55%

1.24%

7.50%

PV

IS

: 1 8+

.6

PV

IE

: 8

.4

PV

IS

: 2 0+

.9

PV

IE

: 8

.2

PV

IS

: 2 1+

.3

PV

IE

: 8

.4

PVI STA = 19+90.19

PVI ELEV = 863.56

A.D. = 5.65% K = 26.56

150.00' VC

BV

C

S:

9+

.1

BV

C

E:

.1

EV

C

S:

0+

.1

EV

C

E:

.1

18 '' HDPE ST

15 '' HDPE ST

C B-

R

IM

.2

IN

V

8.

(1

5" N

PROPOSED GRADEEXISTING GRADE

15 '' HDPE ST

C

BM

H -1

R

IM

.9

IN

V

4.

(1 5"

N E)

IN

V

2.

(1

8" W

IN

V

3.

(1 8"

S E)

C

BM

H -1

R

IM

.1

IN

V

3.

(1 8"

N W

IN

V

5.

(4 " N

E)

IN

V

4.

(1 5"

S

C

BM

H -1

R

IM

.2

IN

V

5.

(1 5"

N

IN

V

5.

(1

5" S

IN

V

5.

(1 2"

N E)

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

8+91

7+00

8+00CB-107

CB-111

FL 874.06

FL 870.28

FL 870.59

FL 872.75FL 870.40

FL 869.80

CBMH-112

CBMH-110

CBMH-108

+0

17+00

18+00

19+00

20+00

21+00

+3

PT

: 1

8+

.5

PC

: 1

8+

.5

EP: 21+36.36

L3

C12

ALIGNMENT LINE DATA

LINE #

L3

LENGTH

1.0000

BEARING

S4° 18' 11.43"E

START POINT

(2191868.8860, 360436.7034)

END POINT

(2191868.9610, 360435.7062)

ALIGNMENT CURVE DATA

CURVE #

C12

RADIUS

199.96

LENGTH

254.78

CHORD DIRECTION

SOUTH40.068691EAST

START POINT

(2191868.9610,360435.7062)

END POINT

(2192022.0934,360253.6539)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA

F

O

A

Fi le

P at h:

y

:\1

\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\

_0 sh ee ts \1

_c _r oa ds

_1 ro ad a

.d w bn or av ed

:6 /1

8/

:3 lo t:6

/2 2/

:5

PM

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026

Date:

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

897CM3025

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

BID DOCUMENTS

KEY MAP N.T.S.

Office of Design and Construction

Services

BID SUBMITTAL

OF ---

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 CR116

116VBAT

PLAN & PROFILE - ROAD A (STA.

16+00 - 21+50)

SCALE:2

PROFILE VIEW ROAD A STA. 16+00 - 21+50

H: 1" = 30' V: 1" = 2.5'

N0 30' 60'

SCALE:1

PLAN VIEW ROAD A STA. 16+00 - 21+50

1" = 30'

MATCHLINE - SEE SHEET CR115 SEE SHEET CR102

IGC

SECTION 73

IGC

SECTION 74

1. BENCHMARK, SEE TOPOGRAPHIC

SURVEY.

2. FULL-DEPTH PAVEMENT & CURB

REMOVAL MUST OCCUR IN ALL AREAS

SHOWN AS RECEIVING NEW PAVEMENT.

3. REMOVE ANY TREE ROOTS TO 2' BEYOND

BACK OF CURB.

GENERAL NOTES

CONTRACTOR NOTES

MATCH EXISTING GRADE AT EXISTING

CATCH BASIN INLET.

CONCRETE VALLEY GUTTER (SEE DETAIL

9/CS501)

SUPERELEVATED ROAD SECTION VARYING

SLOPE (SEE DETAIL 1/CS503)

CROWNED ROAD SECTION VARYING SLOPE

(SEE DETAIL 2/CS503)

BARRIER CURB (SEE DETAIL 6/CS501)

ROLL CURB (SEE DETAIL 7/CS501)

SUPERELEVATED ROAD SECTION (SEE

DETAIL 3/CS503)

KEY NOTES

LEGEND

PROPERTY LIMITS

CONSTRUCTION LIMITS

NEW CURB & GUTTER

ROAD SECTION TRANSTION

2" MILL & OVERLAY EXISTING ASPHALT

PAVEMENT

NEW HEAVY DUTY CONCRETE

PAVEMENT (4/CS501)

NEW BITUMINOUS PAVEMENT (2/CS501)

1. VERTICAL PROFILE INFORMATION SHOWN

IN NON-REPLACEMENT AREAS IS FOR

REFERENCE ONLY. ROAD AREAS TO BE

REMOVED ARE INTENDED TO BE REPLACED

TO THE EXISTING VERTICAL DESIGN.

VERTICAL DESIGN DATA HAS BEEN ADDED

FOR CONSTRUCTION PURPOSES.

HOWEVER, THE CONTRACTOR MUST

NOTIFY THE COR OF ANY VARIATION FROM

EXISTING THAT MAY ADVERSELY AFFECT

THE DRAINAGE OR IMPACT ADJACENT

AREAS. THE COR AND ENGINEER WILL

REVIEW AND MAKE FIELD ADJUSTMENTS IN

THOSE AREAS AS NEEDED PRIOR TO

CONSTRUCTION OF NEW PAVEMENTS.

2. TAPER NEW ROAD EDGE OVER 10' MIN

DISTANCE TO MATCH EXISTING ROAD.

3. CONFIRM LOCATION OF EXIST. UTILITIES

PRIOR TO CONSTRUCTION OR

CONNECTION.

4. SOME MATCH-IN LOCATIONS AND PROJECT

LIMITS SHOWN, ARE UNVERIFIED. ACTUAL

PROJECT LIMITS MUST BE VERIFIED BY

CONTRACTOR. NOTIFY COR IMMEDIATELY

IN THE EVENT OF DISCREPANCY.

5. NEW ROADWAY WIDTHS & CURB RADII

MUST MATCH EXISTING CONDITIONS.

6. CONTRACTOR MUST MATCH EXISTING

PAVEMENT EDGE ELEVATION WHERE NO

PROPOSED CURB AND GUTTER IS SHOWN

7.81%

3.23% -3.35% -0.78%

3.24%

-1.49%

PV

IS

: 2 0+

.0

PV

IE

: 8

.1

1 PV

IS

: 2 3+

.2

PV

IE

: 8

.3

PV

IS

: 2 4+

.5

PV

IE

: 8

.3

PV

IS

: 2 8+

.2

PV

IE

: 8

.7

7PVI STA = 20+93.20

PVI ELEV = 852.39

A.D. = -4.58% K = 21.84

100.00' VC

BV

C

S:

0+

.2

BV

C

E:

.4

EV

C

S:

1+

.2

EV

C

E:

.0

PVI STA = 22+47.89

PVI ELEV = 857.39

A.D. = -6.59% K = 16.70

110.00' VC

BV

C

S:

1+

.8

BV

C

E:

.6

EV

C

S:

3+

.8

EV

C

E:

.5

HIGH PT. STA = 22+46.86

HIGH PT ELEV = 856.49

PVI STA = 25+51.18

PVI ELEV = 852.49

A.D. = 4.02% K = 31.07

125.00' VC

BV

C

S:

4+

.6

BV

C

E:

.9

EV

C

S:

6+

.6

EV

C

E:

.5

LOW PT. STA = 25+12.97

LOW PT ELEV = 852.88

15 '' HDPE ST

PROPOSED GRADEEXISTING GRADE

ST

M

H -2

R

IM

.4

IN

V

9.

(1 6"

W

IN

V

7.

(1

5" N

IN

V

7.

(1 5"

E

C B-

R

IM

.6

IN

V

8.

(1

5" S

B6

SS6

SS6

B6

B6

AE320

20+00

21+00

22+00

23+00

24+00

25+00 26+00

27+00

28+00

28+68

PI

: 2

0+

.7

PI

: 2

0+

.5

PI

: 2

1+

.4

PC

: 2

2+

.6

PC

: 2

1+

.4

PC

: 2

4+

.8

PC

: 2

5+

.9

PT

: 2

3+

.9

PT

: 2

2+

.3

PT

: 2

4+

.4

PT: 27+63.03

CEMETERY RD

C14

C15

STA=20+00

N=358806.17

E=2192360.45

STA=28+68

N=358005.10 E=2192348.19

CBMH-204

CBMH-201

CB-200

CBMH-205

STMH-208

CB-202

FES-202C

FES-209

ME 844.98

ME 845.30

FL 845.43

FL 852.09

FL 845.80

FL

.7

FL 857.09

FL 855.36

FL 854.40

FL 852.55

FL 852.91

FL 852.20

FL 859.46

FL 862.25

FL 862.49

FL 862.90

FL 862.72EXISTING ADMINBUILDING

NEW BUILDINGADDITION

C20

C21

C22 C23

CB-206

CB-203

STMH-207

FL 852.82

FL 860.06

FL 861.37

FL 862.02

FL 852.80

FL 857.69

FL 852.69

ALIGNMENT LINE DATA

LINE # LENGTH BEARING START POINT END POINT

ALIGNMENT CURVE DATA

CURVE # RADIUS LENGTH CHORD DIRECTION START POINT END POINT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA

F

O

A

Fi le

P at h:

y

:\1

\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\

_0 sh ee ts \1

_c _r oa ds

_1 a dm in .d w bn or av ed :6

/1 8/

:3 lo t:6 /2

2/

:5

PM

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026

Date:

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

897CM3025

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

BID DOCUMENTS

KEY MAP N.T.S.

Office of Design and Construction

Services

BID SUBMITTAL

OF ---

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 CR117

117VBAT

PLAN & PROFILE - CEMETERY

ROAD (STA. 20+00 - 28+50)

SCALE:2

PROFILE VIEW CEMETERY ROAD STA. 20+00 - 28+50

H: 1" = 30' V: 1" = 2.5'

N

0 30' 60'

SCALE:1

PLAN VIEW CEMETERY ROAD STA. 20+00 - 28+50

1" = 30'

5 EXISTING

SECTION 42

1. BENCHMARK, SEE TOPOGRAPHIC

SURVEY.

2. FULL-DEPTH PAVEMENT & CURB

REMOVAL MUST OCCUR IN ALL AREAS

SHOWN AS RECEIVING NEW PAVEMENT.

3. REMOVE ANY TREE ROOTS TO 2' BEYOND

BACK OF CURB.

GENERAL NOTES

CONTRACTOR NOTES

MATCH EXISTING GRADE AT EXISTING

CATCH BASIN INLET.

CONCRETE VALLEY GUTTER (SEE DETAIL

9/CS501)

SUPERELEVATED ROAD SECTION VARYING

SLOPE (SEE DETAIL 1/CS503)

CROWNED ROAD SECTION VARYING SLOPE

(SEE DETAIL 2/CS503)

BARRIER CURB (SEE DETAIL 6/CS501)

ROLL CURB (SEE DETAIL 7/CS501)

SUPERELEVATED ROAD SECTION (SEE

DETAIL 3/CS503)

KEY NOTES

LEGEND

PROPERTY LIMITS

CONSTRUCTION LIMITS

NEW CURB & GUTTER

ROAD SECTION TRANSTION

2" MILL & OVERLAY EXISTING ASPHALT

PAVEMENT

NEW HEAVY DUTY CONCRETE

PAVEMENT (4/CS501)

NEW BITUMINOUS PAVEMENT (2/CS501)

1. VERTICAL PROFILE INFORMATION SHOWN

IN NON-REPLACEMENT AREAS IS FOR

REFERENCE ONLY. ROAD AREAS TO BE

REMOVED ARE INTENDED TO BE REPLACED

TO THE EXISTING VERTICAL DESIGN.

VERTICAL DESIGN DATA HAS BEEN ADDED

FOR CONSTRUCTION PURPOSES.

HOWEVER, THE CONTRACTOR MUST

NOTIFY THE COR OF ANY VARIATION FROM

EXISTING THAT MAY ADVERSELY AFFECT

THE DRAINAGE OR IMPACT ADJACENT

AREAS. THE COR AND ENGINEER WILL

REVIEW AND MAKE FIELD ADJUSTMENTS IN

THOSE AREAS AS NEEDED PRIOR TO

CONSTRUCTION OF NEW PAVEMENTS.

2. TAPER NEW ROAD EDGE OVER 10' MIN

DISTANCE TO MATCH EXISTING ROAD.

3. CONFIRM LOCATION OF EXIST. UTILITIES

PRIOR TO CONSTRUCTION OR

CONNECTION.

4. SOME MATCH-IN LOCATIONS AND PROJECT

LIMITS SHOWN, ARE UNVERIFIED. ACTUAL

PROJECT LIMITS MUST BE VERIFIED BY

CONTRACTOR. NOTIFY COR IMMEDIATELY

IN THE EVENT OF DISCREPANCY.

5. NEW ROADWAY WIDTHS & CURB RADII

MUST MATCH EXISTING CONDITIONS.

6. CONTRACTOR MUST MATCH EXISTING

PAVEMENT EDGE ELEVATION WHERE NO

PROPOSED CURB AND GUTTER IS SHOWN

File details come from the government source that posted it. Updated .