_31 LNC BD - TECHNOLOGY pt3 FIRE ALARM (pg 241-247).pdf

PDF 12 MB Posted

Attached to
Leavenworth National Cemetery, Gravesite Expansion
Solicitation number
36C78626B0027
Issued by

About this file

This document comprises the technology and fire alarm design drawings and schedules for the Leavenworth National Cemetery Gravesite Expansion project located at 150 Muncie Road, Leavenworth, Kansas. The bid documents are prepared for the U.S. Department of Veterans Affairs, with project number 897CM3025 and design number 18704, dated June 22, 2026.

The technology infrastructure requires installation of a comprehensive integrated security system including video surveillance, access control, and intrusion detection capabilities. The contractor must provide and install a new video management storage server compatible with the existing system, integrate new card readers and intrusion devices with the existing access control and intrusion detection system, and coordinate all connections and programming with VA OIT. The security system includes nine video surveillance cameras (four interior standard-view cameras mounted in ceilings; five exterior 360-degree cameras mounted at corners), access control door hardware with card readers for five controlled doors, and motion detectors for intrusion detection. All security network equipment must support a minimum of 8 hours of battery backup during power failures. The contractor must provide Category 6A plenum-rated horizontal cabling, install a 48-port network switch to support the dedicated security network, and establish connectivity through existing fiber optic cable between buildings. The fire alarm system integrates addressable smoke detectors, heat detectors, manual pull stations, audio/visual notification appliances, duct smoke detectors, and a carbon monoxide detector, with connections to HVAC shutdown relays and the existing Siemens Desigo fire alarm control panel. All bonding conductors must be plenum-rated copper connected via compression lugs, exothermic welding, or irreversible compression connectors, with sizing determined by conductor length per the bonding conductor sizing schedule. The contractor is responsible for all programming, configuration, testing, and coordination required to ensure devices are connected and operational in both buildings.

View the file

Other files

File Type Posted
S06_36C78626B0027 Amend. 0002.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_CivilSheets_CG100-CR117_20260916.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_CivilSheets_CD100-CB501_20260916.pdf PDF
S04_Attachment - Site Visit Attendance Roster.pdf PDF
S02_Attachment - 18704_LNC_Addendum1_SurveySheets_V100-V113_20260916.pdf PDF
S02_Attachment - 00 01 10 Table of Contents.pdf PDF
S02_Attachment - Substitution Request - Leavenworth GSE.pdf PDF
S02_Attachment - 00 00 00 Specification Cover.pdf PDF
S02_Attachment - 01 35 26 Safety Requirements.pdf PDF
_11 LNC BD - GRADING DRAINAGE (pg 78-82).pdf PDF
_28 LNC BD - PLUMBING (pg 224-230).pdf PDF
_24 LNC BD - INTERIORS (pg 182-188).pdf PDF
_23 LNC BD - ARCH pt2 (pg 171-181).pdf PDF
_19 LNC BD - SIGNAGE FURNISHINGS pt2 (pg 126-138).pdf PDF
_16 LNC BD - ROADS pt2 (pg 106-113).pdf PDF
_05 LNC BD - DEMOLITION pt1 (pg 22-34).pdf PDF
_07 LNC BD - SITE (pg 41-49).pdf PDF
_02 LNC BD - EX CON pt1 (pg 3-16).pdf PDF
LNC Gravesite Expansion VOL1SPECS wGEOTECH - BD 06-22-2026.pdf PDF
S02_Attachment - Price Schedule Sheet.pdf PDF
_20 LNC BD - PLANTING IRR pt1 (pg 139-149).pdf PDF
_14 LNC BD - EROSION CONTROL pt3 UTIL pt1 (pg 91-98).pdf PDF
_22 LNC BD - ARCH pt1 (pg 159-170).pdf PDF
_09 LNC BD - COLUMBARIUM 3 pt1 (pg 60-69).pdf PDF
_10 LNC BD - COLUMBARIUM 3 pt2 (pg 70-77).pdf PDF
LNC Gravesite Expansion VOL2SPECS wGEOTECH - BD 06-22-2026.pdf PDF
_08 LNC BD - BURIALS (pg 50-59).pdf PDF
_30 LNC BD - TECHNOLOGY pt2 (pg 236-240).pdf PDF
_03 LNC BD - EX CON pt2 (pg 17).pdf PDF
S02_Attachment - Statement of Work.pdf PDF
S02_Attachment - Davis-Bacon Act Poster.pdf PDF
_26 LNC BD - ELECTRICAL (pg 201-214).pdf PDF
_29 LNC BD - TECHNOLOGY pt1 (pg 231-235).pdf PDF
_25 LNC BD - STRUCTURAL (pg 189-200).pdf PDF
_21 LNC BD - IRR pt2 (pg 150-158).pdf PDF
_18 LNC BD - SIGNAGE FURNISHINGS pt1 (pg 118-125).pdf PDF
_12 LNC BD - EROSION CONTROL pt1 (pg 83-86).pdf PDF
_13 LNC BD - EROSION CONTROL pt2 (pg 87-90).pdf PDF
_17 LNC BD - ROADS pt3 (pg 114-117).pdf PDF
_04 LNC BD - GEOTECH (pg 18-21).pdf PDF
S02_Attachment - Wage Determination Heavy.pdf PDF
S02_Attachment - Wage Determination Building.pdf PDF
S02_Attachment - Limitations on Subcontracting Cert.docx DOCX document
S02_Attachment - DOL Payroll Form.pdf PDF
_15 LNC BD - UTIL pt2 ROADS pt1 (pg 99-105).pdf PDF
_06 LNC BD - DEMO pt2 OPERATIONS (pg 35-40).pdf PDF
_27 LNC BD - MECHANICAL (pg 215-223).pdf PDF
_01 LNC BD - GENERAL (pg 1-2).pdf PDF
S02_Attachment - Standard Form 1413.pdf PDF
S02_36C78626B0027 Solicitation.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SC-MPP-1

EXISTING FIBER

PANEL

SC-NS-1

VS-VMS-1

EXISTING FIBER

PANEL

OWNER

PROVIDED

EQUIPMENT

SC-FDC-1

SC-NS-1

SC-GND-1

ELECTRICAL

PANEL

SERVING ROOM

BUILDING

STEEL

ACCESS

CONTROL

EQUIPMENT

METALLIC

CONDUITS AND

SLEEVES

EQUIPMENT

RACK(S)

CABLE TRAY

SC-GND-1

SC-NS-1

AC-SCP-1

REQUEST TO

EXIT

ELECTRONIC

LOCKING

HARDWARE

DOOR

POSITION

SWITCH

AC-R1-W

ID-ICP-1

SC-NS-1

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION.

REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE INSTALLED AT EACH INFORMATION OUTLET.

SECURITY SYSTEM PROGRAMMING NOTES:

1. CONTRACTOR TO PROVIDE AND INSTALL NEW VIDEO MANAGEMENT STORAGE SERVER TO SUPPORT NEW CAMERAS BY THIS PROJECT. VIDEO MANAGEMENT SERVER SHALL MATCH EXISTING SERVER INSTALLED UNDER SEPARATE PROJECT.

2. CONTRACTOR SHALL COORDINATE WITH VA OIT TO INTEGRATE NEW CARD READERS AND INTRUSION DEVICES TO THE EXISTING ACCESS CONTROL AND INTRUSION DETECTION SYSTEM. CONTRACTOR SHALL PROVIDE ALL NECESSARY

CONNECTIONS, PROGRAMMING, ETC. FOR CAMERA INTEGRATION AND TESTING.

3. CONTRACTOR SHALL COORDINATE WITH VA OIT TO INTEGRATE NEW CAMERAS TO THE EXISTING VIDEO MANAGEMENT SYSTEM. CONTRACTOR SHALL PROVIDE ALL NECESSARY CONNECTIONS, PROGRAMMING, ETC. FOR CAMERA

INTEGRATION AND TESTING.

4. CONTRACTOR SHALL INCLUDE IN THEIR BID ALL PROGRAMMING NECESSARY TO INSTALL AND CONFIGURE SECURITY NETWORK. TEST ALL DEVICES IN BOTH BUILDINGS TO ENSURE DEVICES ARE CONNECTED AND OPERATIONAL.

KEYNOTES:

1. CATEGORY 6A PLENUM RATED HORIZONTAL CABLE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

2. REFER TO THE INFORMATION OUTLET SCHEDULE ON T600 AND THE FLOOR PLANS FOR THE QUANTITY OF CABLES AND

JACKS TO BE INSTALLED AT EACH LOCATION.

3. CONTRACTOR PROVIDED GOVERNMENT INSTALLED PATCH CABLE. REFER TO SPECIFICATIONS.

4. CONTRACTOR PROVIDED AND INSTALLED PATCH CABLE. REFER TO SPECIFICATIONS.

5. OPTICAL FIBER INSTALLED UNDER SEPARATE PROJECT.

6. CONTRACTOR TO COORDINATE WITH VA OIT AND CONNECT NEW SECURITY NETWORK SWITCHES TO EXISTING FIBER

OPTIC CABLE INSTALLED BETWEEN BUILDINGS.

7. CONTRACTOR PROVIDED AND INSTALLED PATCH CORD TO SUPPORT VIDEO SURVEILLANCE CAMERAS.

8. RACK OR CABINET AS DEFINED ON THE TELECOM ROOM LAYOUT. REFER TO THE TELECOM ROOM REFERENCES MATRIX

ON THE COVER PAGE FOR LOCATION.

9. REFER TO FLOOR PLANS FOR TELECOMMUNICATIONS ROOM LOCATIONS.

10. INSTALL NEW NETWORK SWITCH TO SUPPORT A NEW DEDICATED SECURITY NETWORK. CONNECT EXISTING VIDEO

SURVEILLANCE AND ACCESS CONTROL SERVERS TO SECURITY NETWORK.

11. COORDINATE WITH TRAILER MANUFACTURER ON FINAL LOCATION OF FIBER PANEL PRIOR TO CABLE INSTALLATION.

12. RELOCATE EXISTING WALL CABINET TO NEW RACK. CONTRACTOR SHALL COORDINATE WITH VA OIT WHEN PANEL AND

OPTICAL CABLE WILL BE RELOCATED.

13. 6-STRAND OS2 SINGLE MODE OPTICAL FIBER. TERMINATE NEW FIBERS IN EXISTING FIBER PANEL IN THE ADMINISTRATION

BUILDING.

C#

C#

MAINTENANCE BUILDING

ADMINISTRATION BUILDING 9

EXISTING VIDEO

MONITOR AND

KEYBOARD

EXISTING VIDEO

SURVEILLANCE

SERVER

EXISTING ACCESS

CONTROL

SERVER

TEMPORARY TRAILER

TELECOMMUNICATIONS

BONDING JUMPER (TBJ)

TELECOMMUNICATIONS ROOM 1

TELECOMMUNICATIONS

BONDING JUMPER (TBJ)

NOTES:

1. THIS FLOW DIAGRAM IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS. THIS FLOW DIAGRAM IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND CONDUCTOR TYPE. ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND NOT REPRESENTATIVE OF ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND ENLARGED FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM MUST BE [PLENUM RATED] COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR). REFER TO BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING CRITERIA FOR CONDUCTORS. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

3. ALL BONDING CONDUCTORS MUST BE CONNECTED BY COMPRESSION LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION CONNECTORS. SOLDER IS NOT AN ACCEPTABLE MEANS OF CONNECTION. SHEET METAL SCREWS MUST NOT BE USED TO CONNECT COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT AND/OR USE PAINT-

PIERCING WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL CONNECTIONS.

4. REFER TO 4/T400 FOR BONDING BUS BAR DETAIL AND ADDITIONAL INFORMATION AND REQUIREMENTS FOR SC-GND-1.

KEYNOTES:

1. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON THE COVERSHEET T000 FOR TELECOMMUNICATIONS ROOM NUMBER AND

LOCATION INFORMATION.

2. INCLUDES HORIZONTAL AND VERTICAL CONDUIT SLEEVES FOR TECHNOLOGY CABLING.

3. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT), TO ELECTRICAL ENTRANCE INTERSYSTEM BONDING TERMINATION. REFER

TO 3/T402 FOR TELECOMMUNICATIONS BONDING RISER DIAGRAM FOR CONTINUATION AND ADDITIONAL INFORMATION AND

REQUIREMENTS.

4. REFER TO THE ELECTRICAL DRAWINGS FOR LOCATION.

5. PROVIDE SC-GND-2 RACK MOUNT TELECOMMUNICATIONS BONDING BUSBAR AT EACH EQUIPMENT RACK AND CABINET.

CONDUCTOR

LENGTH IN FEET

BONDING CONDUCTOR SIZING SCHEDULE

MINIMUM ACCEPTABLE

SIZE - AWG

LESS THAN 13' 6

14' - 20' 4

21' - 26' 3

27' - 33' 2

34' - 41' 1

42' - 52' 1/0

53' - 66' 2/0

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS.

THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND CONDUCTOR TYPE.

ALL CONNECTIONS AND SYSTEM DEVICES SHOWN ARE TYPICAL AND NOT REPRESENTATIVE OF

ACTUAL PROJECT QUANTITIES. REFER TO FLOOR PLANS AND ENLARGED FLOOR PLANS FOR ACTUAL QUANTITIES AND LOCATIONS OF DEVICES AND MORE SPECIFIC ROUTING INFORMATION. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. ALL CONDUCTORS IN THE TECHNOLOGY BONDING SYSTEM SHALL BE MINIMUM SIZE OF 3/0 AWG

PLENUM RATED COPPER (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR) UNLESS

CONDUCTOR LENGTH IS LESS THAN 66 FEET. REFER TO BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING CRITERIA FOR CONDUCTORS LESS THAN 66 FEET IN LENGTH. REFER TO SPECIFICATIONS

FOR ADDITIONAL REQUIREMENTS.

3. ALL BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY COMPRESSION

LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMPRESSION CONNECTORS. SOLDER IS NOT AN

ACCEPTABLE MEANS OF CONNECTION. SHEET METAL SCREWS SHALL NOT BE USED TO CONNECT

COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT. WHERE NECESSARY, REMOVE PAINT

AND/OR USE PAINT-PIERCING WASHERS TO PROVIDE PROPER ELECTRICAL BOND AT ALL

CONNECTIONS.

4. REFER TO 2/T500 FOR TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM.

5. REFER TO TELECOM ROOM REFERENCES SCHEDULE ON DRAWING ON THE COVERSHEET T000 FOR

TELECOMMUNICATIONS ROOM NUMBER AND LOCATION INFORMATION.

KEYNOTES:

1. BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT). BCT SHALL BE THE SAME SIZE AS THE TBB

OR LARGER. REFER TO BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING REQUIREMENTS.

ELECTRICAL ENTRANCE

INTERSYSTEM BONDING

TERMINATION

GROUNDING ELECTRODE

CONDUCTOR BY OTHERS

ELECTRICAL GROUNDING

ELECTRODE SYSTEM

FIRST

FLOOR

TR-1

GREATER THAN 301' 750 kcmil

ADMINISTRATION BUILDING

NOTES:

1. THIS RISER IS A DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIAL SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S), LOCATIONS, AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO THE FLOOR PLANS FOR MORE SPECIFIC ROUTING

INFORMATION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. THIS INTEGRATED SYSTEM INCLUDES DEVICES FOR AN INTRUSION DETECTION SYSTEM AND AN ACCESS CONTROL SYSTEM. REFER TO THE SPECIFICATIONS FOR ADDITIONAL

INFORMATION .

3. ALL CABLING LISTED HERE ARE MINIMUM REQUIREMENTS. FINAL GUAGE AND QUANTITY IS BASED ON THE DISTANCE FROM THE NEAREST CONTROL PANEL AND THE NUMBER OF DOORS AT EACH LOCATION. CREDENTIAL READERS WILL OPEN A SINGLE DOOR WITH THE SECOND DOOR BEING MONITORED BY THE SYSTEM.

4. ALL ACCESS CONTROL EQUIPMENT AND DOOR HARDWARE WILL REQUIRE TO BE ON A MINIMUM OF 8 HOURS OF BATTERY TIME IN THE EVENT OF A POWER FAILURE. THIS INCLUDES ALL OF THE INPUT/OUTPUT CARDS, DOOR CONTROLLERS, ENDPOINTS (SUCH AS CARD READERS, MOTION DETECTORS, AND DOOR POSITIONS SWITCHES), DOOR POWER SUPPLIES AND ALL OTHER DEVICES REQUIRED TO SUPPORT THE SYSTEM FUNCTIONALITY. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

5. ALL DOORS REQUIRE ROUGH-IN AT ALL LOCATIONS. REFER TO 5/T400 FOR ROUGH-IN REQUIREMENTS.

6. THIS SYSTEM INCLUDES A SINGLE SYSTEM THAT IS CAPABLE OF PROVIDING CARD ACCESS AND INTRUSION DETECTION. COORDINATE WITH THE CONTRACTOR FOR PROGRAMMING

REQUIREMENTS TO DISABLE THE ALARM SYSTEM. THE ALARM SYSTEM WILL BE DISABLED VIA A DEDICATED KEYPAD AND THE KEYPAD ON NAY CREDENTIAL READER.

7. CREDENTIALS ARE BY GOVERNMENT. CONTRACTOR SHALL INCLUDE IN THEIR BID PROGRAMMING COST TO ASSIST GOVERNMENT TO INSURE ALL CURRENT STAFF HAVE BUILDING

ACCESS.

8. THE EXISTING ACCESS CONTROL SYSTEM HEADEND IS MANUFACTURED BY SOFTWAREHOUSE. NEW SYSTEM COMPONENTS SHALL BE OF THE SAME MANUFACTURER.

KEYNOTES:

1. DOOR POSITION SWITCH WILL CONNECT TO BOTH THE ACCESS CONTROL AND INTRUSION DETECTION SYSTEM. REFER TO FLOOR PLANS AND SITE PLANS FOR ADDITIONAL

INFORMATION.

2. TYPICAL OF ALL DOORS AS SHOWN ON THE DRAWINGS. REFER TO THE CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T600 AND SPECIFICATIONS FOR QUANTITY OF

DEVICES AT EACH LOCATION.

3. A MINIMUM OF 18 AWG 4-CONDUCTOR, UNSHIELDED CABLE. 2 CONDUCTORS WILL CONNECT TO THE ACCESS CONTROL SYSTEM AND THE REMAINING 2 CONDUCTORS WILL CONNECT TO THE INTRUSION DETECTION SYSTEM. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

4. A MINIMUM OF 18 AWG 4-CONDUCTOR, SHIELDED CABLE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION

5. A MINIMUM OF 18 AWG 6-CONDUCTOR, UNSHIELDED CABLE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

6. CATEGORY 6 PATCH CABLE FROM THE ACCESS CONTROL SYSTEM TO THE SECURITY NETWORK. PATCH PANEL INSTALLED IN THE NEAREST TELECOM ROOM. REFER TO TELECOM ROOM

LAYOUTS ON 1/T300 AND 3/T300 FOR ADDITIONAL INFORMATION.

7. EXISTING CABLE INSTALLED UNDER SEPARATE PROJECT.

8. REFER TO FLOOR PLANS FOR CARD READER LOCATIONS.

9. CONTRACTOR SHALL PROVIDE ALL INPUT/OUTPUT CARDS, MODULES, ETC NECESSARY FOR A COMPLETE INSTALLATION AND INTEGRATE TO THE EXISTING HEADEND SYSTEM.

10. PROVIDED AND INSTALLED BY THE DOOR HARDWARE CONTRACTOR.

ADMINISTRATION BUILDING

EQUIPMENT RACK

DOOR HARDWARE 2

A

G

M

WALL MOUNTED

EQUIPMENT

K1

MAINTENANCE BUILDING TR

EXISTING

ACCESS

CONTROL

SERVER

GB1

MD1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:3

P

M

T500

TECHNOLOGY DIAGRAMS

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

NO SCALE1

FIBER AND COPPER CONNECTIVITY DIAGRAM

NO SCALE2

TYPICAL TELECOM ROOM BONDING FLOW DIAGRAM

NO SCALE3

TECHNOLOGY BONDING RISER DIAGRAM

NO SCALE4

ACCESS CONTROL & INTRUSION DETECTION CONNECTIVITY DIAGRAM

Revisions: Date:

VA

F

O R

M

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-500

2-Port Faceplate

IDENTIFICATION

IDENTIFICATION

PAIR 3

PAIR 1PAIR 2 PAIR 4

WO WGO BL WBL G WBR BR

1 32 4 5 6 7 8

ANSI/TIA/EIA T568B

PIN/PAIR ASSIGNMENT

REFER TO SPECIFICATIONS FOR

IDENTIFICATION REQUIREMENTS (TYP.)

NUMBER INDICATES

FACEPLATE POSITION

(TYP.)

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:3

P

M

T600

TECHNOLOGY SCHEDULES

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 PMM TK

BID DOCUMENTS

18704

THE EQUIPMENT LIST ABBREVIATIONS AND THE TECHNOLOGY EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING

SYSTEM.

CATALOG NUMBERS ARE NOT TO BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE

DRAWINGS AND SPECIFICATIONS.

MANUFACTURER PROVIDED SHALL BE CONSISTENT WITH APPROVED MANUFACTURERS LISTED. "STANDARD COLOR" INDICATES FACTORY FINISH AT NO ADDITOINAL

CHARGE. ALL EQUIPMENT MUST MEET BY AMERICAN REQUIREMENTS.

TECHNOLOGY EQUIPMENT SCHEDULE

EQUIPMENT LIST

ABBREVIATION EQUIPMENT LIST DESCRIPTION

MANUFACTURER AND

MODEL

AC-AA-1 WALL MOUNTED AUDIBLE SIREN TO NOTIFY OF A BREACH. INSTALL DEVICE IN A 4" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING. INSTALL A 1" EMT CONDUIT TO THE NEAREST SUPPORTING SECURITY PANEL

WBOX

OE-1GANGSIRN

AC-K1-W INTRUSION ALARM KEYPAD. ILLUMINATED 4-LINE DISPLAY LCD SHOWS ZONE INFORMATION. ECP BUS COMPATIBLE.

INSTALL KEYPAD IN A 4" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING WITH (1) 1" CONDUIT TO ABOVE

ACCESSIBLE CEILING.

HONEYWELL

VISTA 6160

AC-R1-W DUAL AUTHENTICATION CARD READER WITH KEYPAD. PROVIDED AS INTEGRAL PART OF SECURITY MANAGEMENT SYSTEM. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE FOR ADDITIONAL INFORMATION. CARD READERS SHOWN ON PLANS TO INDENTIFY INTENDED MOUNTING LOCATION. REFER TO THE SPECIFICATIONS FOR

COMPLETE INFORMATION.

HID

SIGN 40K SERIES

AC-SCP-1 SECURITY MANAGEMENT SYSTEM CONTROLLER, FOR USE WITH INTEGRATED SECURITY MANAGEMENT SYSTEM.

REFER TO SPECIFICATION SECTION 28 13 00 FOR COMPLETE INFORMATION.

SOFTWARE HOUSE

ISTAR ULTRA G2

NO SUBSTITUTIONS

ID-GB1-C GLASS BREAK CEILING SURFACE MOUNTED. PROVIDE 22/4 TO THE SECURITY PANEL. FIELD VERIFY LOCATION.

PROVIDE ONE 711S ADDRESSABLE MODULE FOR EACH LOCATION.

HONEYWELL INTELLISENSE

FG-1625RT

ID-ICP-1 INTRUSION DETECTION CONTROLLER. PROVIDES UP TO 40 POINTS INCLUDING MOTION DETECTORS, KEYPADS, GLASS BREAKS, ETC. PROVIDE WITH INPUT CARDS AS REQUIRED TO SUPPORT THE CONNECTED DEVICES. PROVIDE AN INTERFACE MODULE FOR UP TO (2) TELEPHONE LINES, A LOCKABLE CABINET, AND BATTERY BACKUP FOR A MINIMUM

OF 6 HOURS.

HONEYWELL

VISTA 128BPT SERIES

ID-MD1-C INTRUSION DETECTION MOTION SENSOR, CEILING MOUNTED, DIMENSION: 3.5" x 5.25" (H x Dia.) REQUIRE INPUT POWER 6-15 VDC; 8mA STANDARD BY, 60mA IN ALARM WITH LEDS ENABLED. DEVICE COMPLIES WITH PART 15 OF THE FCC

RULES.

BOSCH

ISC-CDL1-WA15G

PW-CPW-1 4"X4" FIREPROOF CABLE PATHWAY FOR WALLS UP TO 10" THICK. STI

44 SERIES

OR PRE-APPROVED EQUAL

SC-CT-1 CABLE TRAY, WIRE MESH TYPE, 18" LOADING DEPTH, 4" WIDTH, COMPLETE WITH ALL FITTINGS AND MOUNTING HARDWARE. PROVIDE TRAPEZE SUPPORT WITH PLASTIC RETAINER. CUTTING OF THE MESH CABLE TRAY SHALL BE DONE WITH OFFSET BOLT CUTTERS ONLY. 10' MAXIMUM SUPPORT SPAN. EITHER SPLICE WASHERS OR TERMINAL GROUND SUPPORT AND JUMPER WIRE SHALL BE USED TO ATTAIN GROUNDING CONTINUITY THROUGHOUT.

Z-BRACKETS SHALL BE USED FOR WALL MOUNTED APPLICATIONS. REFER TO MANUFACTURERS INSTALLATION

INSTRUCTIONS AND SPECIFICATION SECTION 27 05 28 FOR ADDITIONAL INFORMATION.

WBT

WBT18X4

CABOLFIL

B-LINE

CHATSWORTH

SC-ER-1 4-POST TELECOMMUNICATIONS CHANNEL RACK. 30" DEEP, 7' HIGH, WHITE FINISH, 45RU USABLE HEIGHT, 23.75" WIDE,STATIC LOAD CAPACITY OF 2,000 POUNDS, SQUARE HOLES. REFER TO 3/T401 TYPICAL RACK DIMENSIONS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

ORTRONICS

MM2073038-W

OR PRE-APPROVED EQUAL

SC-FDC-1 1-RU ANGLED FIBER DISTRIBUTION ENCLOSURE. 144 MAXIMUM FIBERS WITH SLIDING TRAY. PROVIDE COMPLETE WITH FIBER ADAPTER PANELS WITH LC CONNECTORS FOR ALL TERMINATED FIBERS. PROVIDE BLANK PANELS FOR ALL

UNUSED OPENINGS. PROVIDE CABLE CLAMP KITS AS REQUIRED, 5RCMP-KIT.

LEVITON

HDX1A-144

FIBER ADAPTER PANELS

SPLCH-12L (SM)

CABLE MANAGER:

E2XHD-CMB

BLANKS

SF100-PLT

OR PRE-APPROVED EQUAL

SC-GND-1 WALL-MOUNT GROUND BAR. 4" H X 12" L X 1/4" D COPPER, ELECTRICALLY ISOLATED BY INSULATORS INTEGRAL TO MOUNTING BRACKETS. PROVIDE UNIT CONFIGURED WITH SIXTEEN (16) SETS OF 5/16" HOLES SPACED 5/8" ON CENTER TO ACCOMMODATE "A" SPACED TWO-HOLE COMPRESSION LUGS AND THREE (3) SETS OF 7/16" HOLES SPACED 1" ON CENTER TO ACCOMMODATE "C" SPACED TWO-HOLE COMPRESSION LUGS. ANSI/EIA/TIA-607 AND BICSI COMPLIANT. UL

LISTED.

CPI

40153-012

PANDUIT

HARGER

SC-GND-2 RACK MOUNT GROUND BAR WITH FLAT WASHER AND GROUND BAR LUG. ANSI/EIA/TIA-607 AND BICSI COMPLIANT. UL

LISTED.

CHATSWORTH PRODUCTS

10610-019

SC-HWM-1 1RU HORIZONTAL CABLE MANAGER FOR 19' RACK MOUNTING, SINGLE SIDED, BLACK. FRONT COVER WITH HINGE

CLIPS. 8.31" DEEP.

ORTRONICS

SHMC1RU

SC-HWM-2 2RU HORIZONTAL CABLE MANAGER FOR 19' RACK MOUNTING, SINGLE SIDED, BLACK. FRONT COVER WITH HINGE

CLIPS. 8.86" DEEP.

ORTRONICS

SHMC2RU

SC-IO-C OUTLET, SURFACE MOUNT BOX, 2 PORT AS INDICATED ON DRAWINGS. "#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE PLANS. REFER TO T600 FOR INFORMATION OUTLET SCHEDULE FOR PIN CONFIGURATION. INSTALL A 1" EMT CONDUIT 6" BEYOND BOX OR TO ABOVE ACCESSIBLE CEILING AND TERMINATE WITH A NYLON BUSHING. REFER TO DETAIL 3/T400 FOR ADDITIONAL INFORMATION AND INSTALLATION

REQUIREMENTS.

SURFACE BOX -PLENUM

LEVITON

41089 SERIES

JACKS

LEVITON

6AUJK-R*6

SC-IO-F FLOOR BOX - BY ELECTRICAL REFER TO ELECTRICAL

DRAWINGS

SC-IO-W INFORMATION WALL MOUNT, 2, 4 PORT COVERPLATE AS INDICATED ON DRAWINGS. REFER TO TYPICAL INFORMATION OUTLET CONFIGURATIONS DETAIL FOR ADDITIONAL INFORMATION. "#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE PLANS. REFER TO INFORMATION OUTLET SCHEDULE FOR PIN CONFIGURATION. " W " PROVIDE (1) RJ-45 JACK FOR VOICE AT +48" AFF FOR WALL HUNG PHONE. PROVIDE WITH STAINLESS STEEL FACEPLATE, MATING LUGS. INSTALL NEW INFORMATION OUTLET IN A 4" SQUARE BACKBOX WITH A SINGLE/DOUBLE GANG PLASTER RING. INSTALL A 1 1/4" EMT CONDUIT TO ABOVE ACCESSIBLE CEILING. PROVIDE

REMOVABLE BLANK INSERTS FOR UNUSED PORTS.

LEVITON

42080 SERIES

JACKS

LEVITON

6AUJK-R*6

SC-MPP-1 ANGLED MODULAR PATCH PANEL, RACK MOUNT, 48 MODULAR RJ-45 TERMINATIONS, MOUNTS DIRECTLY TO EIA/TIA STANDARD 19" RELAY RACK, PORT IDENTIFICATION NUMBERS, COLOR-CODING, AND LABEL HOLDER KITS, U.L. LISTED.

REQUIRES (1) 1.75" MOUNTING SPACE. POPULATE PATCH PANEL FRAME WITH CAT 6A JACKS AS NEEDED FOR A COMPLETE INSTALLATION. REFER TO 2/T401 UTP PATCH PANEL FOR ADDITIONAL INFORMATION.

PROVIDE WITH ANGLED PANEL COVER.

PATCH PANEL

LEVITON

E2X1A-S48

JACKS

LEVITON

6AUJK-RB6

BLANKS

41084-0BE

ANGLED COVER

E2XHD-COV

CABLE MANAGER

E2XHD-CMB

SC-NS-1 48-PORT LAYER 2/3/4 10/100/1000 GIGABIT SWITCH - POE. 48 RJ-45 CONNECTORS FOR 10BASE - T/100BASE-TX/1000 BASE-T WITH 4 GIGABIT COMBO PORTS SHARED BETWEEN MINI-GBIC PORTS: CONSOLE PORT: AUTO MEDIUM

DEPENDENT INTERFACE (MDI) AND MDI CROSSOVER (MDI-X). AUTO.

CISCO

5500 SERIES

SC-RI-W ROUGH-IN WALL OUTLET 4" SQUARE BACKBOX WITH A SINGLE/DOUBLE GANG PLASTER RING. INSTALL 1 1/4" EMT CONDUIT TO ABOVE ACCESSIBLE CEILING. PROVIDE BLANK FACEPLATE WTIH GROMMET FOR CABLE TO PASS

THROUGH.

SC-TTB TELECOMMUNICATIONS TERMINAL BOARD, 4’X8’X3/4” A-C GRADE FIRE-RATED PLYWOOD. EXPOSED SIDE SHALL BE SMOOTH. MOUNT VERTICALLY WITH TOP OF PLYWOOD AT 8’-6” AFF. IN THE EVENT THE MANUFACTURER’S RATING STAMP IS NOT VISIBLE ON THE SMOOTH SIDE, THE CONTRACTOR SHALL PROVIDE A LAMINATED LETTER FROM THE MANUFACTURER OR SUPPLIER CERTIFYING THAT THE PLYWOOD IS FIRE-RATED AND ATTACH THE LETTER WITH A PICTURE OF THE RATING STAMP, TO THE PLYWOOD. FIRE RATED PLYWOOD SHALL NOT BE PAINTED OR TREATED WITH

ANY TYPE OF SEALANT THAT WOULD LESSEN THE INTEGRITY OF THE FIRE RATING.

SC-UPS RACK MOUNT 3KVA SMART UPS. 2 RACK UNITS. NEMA L5-30P INPUT. (3) NEMA 5-15R, (3) NEMA 5-20R, AND (1) NEMA

L5-30R OUTPUTS. RACK MOUNTABLE.

APC

SMX3000RMLV2U

SC-VWM-1 VERTICAL CABLE MANAGEMENT CAGE WITH DOOR, 6.45” X 10.26” X 76.94” WHITE CAPACITY 350 CATEGORY 6 PR 245 CATEGORY 6A PATCH CORDS. REFER TO 6" WIDE VERTICAL CABLE MANAGER FOR ADDITIONAL INFORMATION.

ORTRONICS

MM20VMD706-W

VS-CM-1 EXTERIOR/INTERIOR 5MP (SINGLE SENSOR) CAMERA. FIXED DOME CAMERA FOR OUTDOOR, HDTV 1080P VIDEO QUALITY, VANDAL-RESISTANT WITH WDR. PROVIDE A PROPER MOUNT BASED ON THE INSTALLED APPLICATIONS ON THE WALL OR CEILING. FOR WALL APPLICATIONS, PROVIDE A 4" SQUARE BACKBOX WITH CONDUIT TO ABOVE THE NEAREST ACCESSIBLE CEILING. ALL CABLING SHALL BE EITHER ABOVE THE ACCESSIBLE CEILING OR INSTALLED IN CONDUIT. NO CABLING SHALL BE EXPOSED. FOR OPEN CEILINGS, INSTALL IN CONDUIT. REFER TO THE DRAWINGS FOR

ADDITIONAL INFORMATION.

AXIS COMMUNICATIONS

P3367-VE

VS-CM-4 360 DEGREE EXTERIOR CORNER MOUNTED CAMERA. 360° OVERVIEW IN CHALLENGING LIGHT CONDITIONS. THREE SENSORS, ONE CAMERA AND ONE IP ADDRESS. 3 X QUAD HD AT 30 FPS OR 15 MP AT 20 FPS. PROVIDE A PROPER MOUNT BASED ON THE INSTALLED APPLICATIONS ON THE WALL OR CEILING. FOR WALL APPLICATIONS, PROVIDE A 4" SQUARE BACKBOX WITH CONDUIT TO ABOVE THE NEAREST ACCESSIBLE CEILING. ALL CABLING SHALL BE EITHER ABOVE THE ACCESSIBLE CEILING OR INSTALLED IN CONDUIT. NO CABLING SHALL BE EXPOSED. FOR OPEN CEILINGS, INSTALL IN CONDUIT. REFER TO THE DRAWINGS FOR ADDITIONAL INFORMATION.

AXIS COMMUNICATIONS

P3737-PLE

VS-VMS-1 VIDEO MANAGEMENT STORAGE SERVER. REFER TO SPECIFICATIONS GENETEC - MATCH EXISTING

ZONE PDU RACK MOUNT PDU, L5-30 INPUT. NEMA 5-20 OUTPUT, 1RU. ZONE*IT

Z-PDS SERIES

INDIVIDUAL CAMERA REQUIREMENTS SCHEDULE

CAMERA #

CAMERA

TYPE

CAMERA

ENVIRONMENT

TELECOM

ROOM # LOCATION FIELD OF VIEW DESCRIPTION

MOUNTING

TYPE

DETAIL

REFERENCE F

R A

M E

R A

T E

P E

R C

E N

T M

O T

IO

N

ADDITIONAL

INFORMATION NOTES

01-01 CM-1 INTERIOR TR-1 TR-1 STANDARD VIEW CEILING 2/T402 15 50

01-02 CM-1 INTERIOR TR-1 CORRIDOR STANDARD VIEW CEILING 2/T402 15 50

01-03 CM-1 INTERIOR TR-1 LOBBY STANDARD VIEW CEILING 2/T402 15 50

01-04 CM-1 INTERIOR TR-1 VESTIBULE STANDARD VIEW CEILING 2/T402 15 50

01-05 CM-4 EXTERIOR TR-1 EXTERIOR 360 DEGREE VIEW CORNER 1/T402 15 50

01-06 CM-4 EXTERIOR TR-1 EXTERIOR 360 DEGREE VIEW CORNER 1/T402 15 50

01-07 CM-4 EXTERIOR TR-1 EXTERIOR 360 DEGREE VIEW CORNER 1/T402 15 50

01-08 CM-4 EXTERIOR TR-1 EXTERIOR 360 DEGREE VIEW CORNER 1/T402 15 50

01-09 CM-4 EXTERIOR TR-1 EXTERIOR 360 DEGREE VIEW CORNER 1/T402 15 50

1. ELECTRONIC DOOR HARDWARE SUCH AS ELECTRIC STRIKES, ELECTRIC LATCH RETRACTION, ETC. SHALL BE PROVIDED AND INSTALLED BY OTHERS.

2. REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR CREDENTIAL READER TYPE INFORMATION.

ACCESS CONTROL DOOR TYPE SCHEDULE

DOOR # S

E

C U

R

IT

Y D

O O

R T

Y P

E

R O

U G

H I N

O N

L Y

CREDENTIAL

READER

REQUEST TO

EXIT DOOR HARDWARE / MONITORING INTEGRATION

OTHER

(REFER TO NOTES)

D E

T A

IL

R

E F

E R

E N

C E

NOTESC

R

E D

E N

T

IA

L R

E A

D E

R T

Y P

E

M U

L T

IP

L

E C

R E

D E

N T

IA

L

R E

A D

E R

S O

P E

R A

T E

S S

IN

G

L E

D O

O R

O P

E R

A T

E S

M U

L T

IP

L

E D

O O

R S

IN

T

E R

N A

L E

L E

C T

R

IF

IE

D

H A

R D

W A

R E

C O

N N

E C

T

IO

N

B Y

O T

H E

R S

M O

T

IO

N D

E T

E C

T O

R

L O

C A

L P

U S

H B

U T

T O

N D

O O

R H

A R

D W

A R

E O

V E

R R

ID

E

E L

E C

T R

O N

IC

L

O C

K

IN

G H

A R

D W

A R

E

B Y

O T

H E

R S

M A

G L

O C

K

L O

C A

L A

L A

R M

H O

R N

L A

T C

H S

T A

T U

S D

E T

E C

T

IO

N

B Y

O T

H E

R S

M O

N

IT

O R

L A

T C

H B

O L

T

B Y

O T

H E

R S

M O

N

IT

O R

D O

O R

P O

S

IT

IO

N

S W

IT

C

H S

P D

T

M O

N

IT

O R

D O

O R

P O

S

IT

IO

N

S W

IT

C

H D

P D

T

M O

N

IT

O R

D O

O R

P O

S

IT

IO

N

S W

IT

C

H

O V

E R

H E

A D

D O

O R

M O

N

IT

O R

D O

O R

P O

S

IT

IO

N

S W

IT

C

H

R O

O F

H A

T C

H

A U

T O

M A

T

IC

D O

O R

O P

E R

A T

O R

E L

E V

A T

O R

L O

C K

E D

B Y

E M

E R

G E

N C

Y D

U R

E S

S S

E Q

U E

N C

E

IN

F

A N

T P

R O

T E

C T

IO

N

R E

M O

T E

U N

L O

C K

V

IA

I N

T E

R C

O M

M A

S T

E R

R E

M O

T E

U N

L O

C K

V

IA

P U

S H

B U

T T

O N

IN

T

R U

S

IO

N D

E T

E C

T

IO

N

R E

M O

T E

U N

L O

C K

V

IA

F

IR

E C

O M

M A

N D

C E

N T

E R

V

ID

E O

S U

R V

E

IL

L A

N C

E

W A

N D

E R

P R

E V

E N

T

IO

N S

Y S

T E

M

D E

L A

Y E

D E

G R

E S

S

B Y

O T

H E

R S

L O

C A

L

V

A C

P O

W E

R S

U P

P L

Y

S C

H E

D U

L E

B A

S E

D L

O C

K

IN

G

V

IS

U A

L S

T R

O B

E /A

U D

IB

L

E A

L A

R M

101A RME R1 ● ● ● ●

105B RME R1 ● ● ●

105C RME R1 ● ● ● ●

B01A RME R1 ● ● ●

B03A RME R2 ● ● ●

SUPPORT FOR POSSIBLE RELOCATION AFTER WIRELESS SURVEY.

1. LOCATION OF FUTURE OR OWNER PROVIDED WIRELESS ACCESS POINT. PROVIDE A 20' SLACK COIL AT THE NEAREST CABLE

SCHEDULE NOTES:

2. REFER TO SPECIFICATIONS SECTION 27 05 53 FOR ADDITIONAL INFORMATION ON LABELING REQUIREMENTS. VOICE CAT 6 RJ-45

1. PROVIDE REMOVABLE BLANK INSERT(S) FOR ALL UNUSED PORTS. DATA CAT 6 RJ-45

NOTES: LEGEND

SINGLE GANG WALLPLATES

TELECOMMUNICATIONS OUTLET SCHEDULE

CONFIGURATION F

A

C E

P L

A T

E P

O R

T S

FACEPLATE PORT IDENTIFICATION

NOTESP

O

S

IT

IO

N

J

A C

K T

Y P

E

P O

S

IT

IO

N

J

A C

K T

Y P

E

P O

S

IT

IO

N

J

A C

K T

Y P

E

P O

S

IT

IO

N

J

A C

K T

Y P

E

P O

S

IT

IO

N

J

A C

K T

Y P

E

P O

S

IT

IO

N

J

A C

K T

Y P

E

C2 2 DATA DATA .

C2-M 2 DATA DATA

C2-WAP 2 DATA DATA 1.

W 1 VOICE

Revisions: Date:

VA

F

O

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

Office of Design and Construction

Services

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789 T-600

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

VIEW NAME

1/8" = 1'-0"

M101

SIMSIM

INDICATES SIMILAR DETAIL REFERENCED

IN MULTIPLE LOCATIONS

LEVEL NAME

10'-0" HEIGHT ABOVE

PROJECT 0'-0"

1 KEYNOTE: INDICATES NOTE USED TO

DESCRIBE ADDITIONAL INFORMATION

ABOUT WORK REQUIRED, SPECIFIC

TO THE SHEET AND/OR DETAIL

N O R

HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE AND TAG KEY:

NEW WORK BY THIS CONTRACTOR (WIDE LINE)

EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)

HALFTONING DOES NOT MODIFY SCOPE.

'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING

TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL

INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST

INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL

T101

NEW

EXISTING TO BE REMOVED (SHORT DASHED PATTERN)

NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

EXISTING

EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)

EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

FIRE ALARM NOTIFICATION AND SIGNAL WIRING

WET AND DAMP LOCATIONS: (CONDUIT, BOXES, FITTINGS,

INSTALLED AND EQUIPPED TO PREVENT WATER ENTRY)

FIRE ALARM CONDUIT INSTALLATION SCHEDULE

THE FOLLOWING SCHEDULE SHALL BE ADHERED TO UNLESS THEY CONSTITUTE A VIOLATION OF APPLICABLE CODES OR ARE NOTED OTHERWISE ON THE DRAWINGS. THE INSTALLATION OF RMC CONDUIT WILL BE PERMITTED IN PLACE OF ALL CONDUIT

SPECIFIED IN THIS SCHEDULE.

INSTALLATION TYPE RMC EMT

X

X

INTERIOR LOCATIONS WITH FINISHED CEILING AND WALLS: CONCEALED

IN WALLS AND ABOVE FINISHED CEILINGS

INTERIOR LOCATIONS WITHOUT FINISHED CEILINGS: CONCEALED IN

WALL, EXPOSED ABOVE CEILINGS

X

X

ASR

EXISTING INTERIOR LOCATIONS WITH FINISHED CEILINGS AND WALLS:

CONCEALED IN WALLS AND ABOVE FINISHED CEILING UNLESS

OTHERWISE NOTED

X

PVC

CONCRETE

ENCASED

UNDERGROUND / SLABS ON GRADE

(IN OR UNDER SLABS ON GRADE)

WITHIN 5' FROM PERIMETER OF THE BUILDING

WITHIN 5' FROM THE PERIMETER OF THE BUILDING WHEN PASSING

THROUGH THE PERIMETER OF THE BUILDING FOUNDATION:

UNDERGROUND SITE CONDUITS:

WITHIN 5' FROM THE PERIMETER OF A BUILDING FOUNDATION

5' OR GREATER FROM THE PERIMETER OF A BUILDING FOUNDATION

X

X

X

X

X

NAC

HVAC UNIT SHUTDOWN (TYPICAL)

(TYP)

SIGNAL LINE CIRCUIT

(SLC)

NOTIFICATION

APPLIANCE CIRCUIT

(NAC)

EXISTING FIRE

ALARM PANEL

2 3

KEYNOTES:

1. REPRESENTATIVE OF PROGRAMMABLE I/O POINTS IN THE PANEL OR A GENERAL

SYSTEM TROUBLE/ALARM CONTACT CONNECTED TO THE SYSTEM NOTED. REFER

TO SPECIFICATIONS FOR MORE INFORMATION.

2. REFER TO SPECIFICATION FOR REQUIREMENTS OF EACH INITIATION LOOP AND

WIRING STYLE. REFER TO FLOOR PLANS FOR DEVICES AND THEIR LOCATIONS.

3. REFER TO SPECIFICATION FOR REQUIREMENTS OF EACH NOTIFICATION

APPLIANCE CIRCUIT AND WIRING STYLE. REFER TO FLOOR PLANS FOR DEVICES

AND THEIR LOCATIONS.

4. PROVIDE NOTIFICATION APPLIANCE EXTENDER PANELS AS REQUIRED.

DETERMINATION OF NEED TO BE MADE BY FIRE ALARM VENDOR. REFER TO

SPECIFICATIONS FOR REQUIREMENTS AND ACCEPTABLE MOUNTING LOCATIONS.

5. REPRESENTS THE EXTENSION OF PROGRAMMABLE RELAYS TO THE ACCESS

CONTROL SYSTEM. REFER TO SPECIFICATION SECTION 28 13 00 FOR QUANTITY OF

POINTS REQUIRED.

6. PROVIDE STANDALONE CELLULAR MODEM. OWNER WILL PROVIDE CELLULAR

SERVICE CONTRACT AS REQUIRED.

NOTES:

1. THE RISER DIAGRAM IS INTENDED TO CONVEY THE TYPES OF FIRE ALARM

CONNECTIONS AND SPECIFICALLY DOES NOT INDICATE QUANTITIES, NUMBER OF

CIRCUITS REQUIRED OR DISTANCES.

2. THE COMPLETE FIRE ALARM SYSTEM SHALL MEET ALL APPLICABLE CODES AND

MANUFACTURER'S RECOMMENDATIONS.

3. CONTRACTOR SHALL COORDINATE ALL WIRE SIZES, TYPES AND REQUIREMENTS

WITH THE VENDOR PRIOR TO BID. REFER TO SPECIFICATIONS TO DETERMINE

CIRCUIT STYLES AND IF CONDUIT IS REQUIRED OR PLENUM RATED CABLE IS

ACCEPTABLE.

4. ALL +120VAC WIRING REQUIRED FOR OPERATION OF THE SYSTEM AS DESCRIBED

IN THE CONSTRUCTION DOCUMENTS SHALL BE PROVIDED BY THE ELECTRICAL

CONTRACTOR.

5. ALL NECESSARY RELAYS MAY NOT BE SHOWN ON THIS PLAN, BUT WHERE

REQUIRED FOR PROPER OPERATION OF THE SYSTEM THEY SHALL BE PROVIDED

BY THE CONTRACTOR.

F

F

S #F

SRT

CM

H

CELLULAR

DIGITAL

COMMUNICATOR

ACCESS

CONTROL PANEL

1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2010 (LATEST

PUBLISHED) ADA STANDARDS FOR ACCESSIBLE DESIGN. REFER TO THE ADA STANDARDS

FOR ALL CONFIGURATION DETAILS ON THIS PAGE FOR ADDITIONAL INFORMATION.

2. MOUNT ALL FIRE ALARM PULL STATIONS AT +42" FROM FLOOR (CENTERLINE DIMENSION)

EXCEPT WHERE OTHERWISE NOTED.

3. INSTALL ALL WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES AT 90" ABOVE FINISHED

FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER, EXCEPT WHERE OTHERWISE

NOTED. HEIGHT SHALL BE MEASURED TO THE TOP OF THE DEVICE.

4. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND

EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES

IN CEILING TILE PATTERN. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS, SHALL

BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN GRILLE.

CARBON MONOXIDE DETECTORS SHALL BE LOCATED 10 PLUS FT FROM FIRE PLACES,

COOKING, AND SIMILAR FUEL-BURNING APPLIANCES.

5. FIRE ALARM EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, OPERATION OF,

AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF FIRE

ALARM EQUIPMENT, ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE

APPROVED IN ADVANCE BY THE OTHER CONTRACTOR.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

7. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE

WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE

IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND

FINISH.

8. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY

AUDIO/VISUAL, AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING

MOUNTED DEVICES.

FIRE ALARM INSTALLATION NOTES:

GENERAL FIRE ALARM EQUIPMENT SCHEDULE

THE SYMBOLS AND THE EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING

SYSTEM.

CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS. MANUFACTURER PROVIDED SHALL BE CONSISTENT WITH APPROVED MANUFACTURERS LISTED. "STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE. ALL EQUIPMENT MUST MEET BUY

AMERICAN REQUIREMENTS. REFER TO SPECIFICATIONS FOR MORE INFORMATION.

ITEM

NO

SYMBOL DESCRIPTION

FIRE ALARM CEILING VISUAL NOTIFICATION APPLIANCE, HIGH-INTENSITY STROBE, WHITE HOUSING

WITH RED LETTERING OR PICTOGRAM, SEMI-FLUSH CEILING MOUNT; 24 VDC.

CANDELA RATINGS: 15cd, 75cd. CANDELA

RATING SHALL BE VISIBLE FROM THE OUTSIDE OF THE DEVICE.

SIEMENS FIRE SAFETY

SMOKE DETECTOR, ADDRESSABLE, ANALOG PHOTOELECTRIC SENSOR, 24 VDC, 2-PIECE DESIGN, LOW-PROFILE MOUNTING BASE WITH MULTI-FUNCTION LED INDICATOR, COMPLETE WITH MOUNTING

HARDWARE AND BACKBOX.

SIEMENS FIRE SAFETY

HEAT DETECTOR, ADDRESSABLE, ANALOG SENSOR, COMBINATION RATE OF RISE AND 135 DEGREE FAHRENHEIT FIXED TEMPERATURE, 2-WIRE OPERATION, 24 VDC, 2-PIECE DESIGN, LOW-PROFILE

MOUNTING BASE WITH MULTI-FUNCTION LED INDICATOR, COMPLETE WITH MOUNTING HARDWARE

AND BACKBOX. PROVIDE A REMOTE LED INDICATOR DEVICE IF DETECTOR IS NOT VISIBLE FROM A

FLOOR-STANDING POSITION.

H

FIRE ALARM CEILING AUDIO/VISUAL NOTIFICATION APPLIANCE, ELECTRONIC HORN WITH

SELECTABLE CONTINUOUS OR TEMPORAL TONE, SELECTABLE SOUND OUTPUT, AND HIGH

INTENSITY STROBE, WHITE HOUSING WITH RED LETTERING OR PICTOGRAM, SEMI-FLUSH CEILING

MOUNT, 24 VDC.

CANDELA RATINGS: 15cd, 75cd. CANDELA

RATING SHALL BE VISIBLE FROM THE OUTSIDE OF THE DEVICE.

SIEMENS FIRE SAFETY

F

S

FIRE ALARM MANUAL PULL STATION, ADDRESSABLE, DOUBLE ACTION WITH PLASTIC BREAKROD, RESET KEY LOCK, SEMI-FLUSH MOUNT, RED HIGH-ABUSE PLASTIC OR CAST METAL

CONSTRUCTION WITH WHITE LETTERING. USE SURFACE MOUNT ONLY ON PRECAST CONCRETE

OR STRUCTURE.

SIEMENS FIRE SAFETY

F

S

DUCT TYPE SMOKE DETECTOR, PHOTOELECTRIC TYPE, 4-WIRE OPERATION, 24 VDC, LED ALARM

INDICATOR, SAMPLING TUBES SIZED TO MATCH DUCT APPLICATION, HOUSING WITH COMPLETE

MOUNTING ACCESSORIES. PROVIDE A REMOTE ALARM LED INDICATOR WITH TEST SWITCH IF

DETECTOR IS NOT VISIBLE FROM A FLOOR-STANDING POSITION. IF DETECTOR IS LOCATED ABOVE A SUSPENDED CEILING, MOUNT REMOTE INDICATOR IN CEILING DIRECTLY BELOW DETECTOR WITH A

WHITE SINGLE-GANG FACEPLATE LABELED: DUCT SMOKE DETECTOR.

SIEMENS FIRE SAFETY

SIEMENS FIRE SAFETY

FIRE ALARM ADDRESSABLE RELAY CONSISTING OF AN ADDRESSABLE CONTROL MODULE AND

SLAVE RELAY WITH CONTACTS SUITABLE FOR CONTROLLING THE DESIGNATED AUXILIARY LOAD, PROVIDE AN ADDITIONAL CHILD RELAY(S) AS REQUIRED, 24 VDC, 4-WIRE OPERATION, MOUNT IN

ENCLOUSER IN AN ACCESSIBLE SERVICE LOCATION.

SIEMENS FIRE SAFETY

CM

GAS DETECTOR, ADDRESSABLE, ANALOG CARBON MONOXIDE TYPE SENSOR, CARBON MONOXIDE

ELECTROLYTIC SENSING MODULE SHALL PROVIDE TOXIC GAS SENSING TO UL2034 AND UL2075

STANDARDS, 24 VDC, LOW-PROFILE MOUNTING BASE WITH MULTI-FUNCTION LED INDICATOR,

COMPLETE WITH MOUNTING HARDWARE AND BACKBOX. CO SENSOR CARTRIDGE ELEMENT SHALL

BE FIELD REPLACEABLE.

SIEMENS FIRE SAFETY

APPROVED MANUFACTURERS

BUILDING CODE: IBC 2024 EDITION

FIRE CODE: IFC 2024 EDITION

ELECTRICAL CODE: NFPA 70 (NEC) 2023 EDITION

LIFE SAFETY CODE: NFPA 101 2024 EDITION

LOCAL BUILDING CODE: CURRENT EDITION

APPLICABLE CODES

CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS

INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING:

CONTACT PERSONS:

PROJECT MANAGER

FIRE ALARM

TECHNOLOGY

MATT SNYDER

MATT SNYDER

PETE MCGHEE

DESCRIPTION: PERSON:

1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD

SURVEYS, EXISTING BUILDING DOCUMENTS. CONTRACTOR SHALL REVIEW EXISTING

CONDITIONS AND REPORT CONFLICTS.

2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. CONTRACTOR

SHALL REVIEW EXISTING CONDITIONS AND REPORT CONFLICTS.

3. CONTRACTOR SHALL REVIEW EXISTING CONDITIONS PRIOR TO FABRICATION OF CABLE

TRAY, BUSWAY, CONDUIT RACKS, AND OTHER SYSTEMS. RISES AND DROPS MAY BE

NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS.

4. ELECTRICAL CONTRACTOR SHALL REVIEW EXISTING CONDITIONS TO VERIFY ACCESSIBILITY

TO THE AREAS OF THEIR WORK INCLUDING WALLS, FLOOR, CEILINGS, CEILING TILES/GRID,

AND ROOF. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE CUTTING, REMOVAL,

PATCHING, AND REINSTALLATION OF AFFECTED AREAS ASSOCIATED WITH THEIR WORK BY

COORDINATING WITH THE GENERAL CONTRACTOR OR QUALIFIED CONTRACTOR.

5. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW

EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER

ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES

NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO

ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.

FIRE ALARM RENOVATION NOTES:

THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED

TO FIRE ALARM.

SYSTEM INPUTS

SEQUENCE OF

OPERATION

P A

N E

L /A

N N

U N

C

IA

T O

R A

L A

R M

I N

D

IC

A T

IO

N

P A

N E

L /A

N N

U N

C

IA

T O

R S

U P

E R

V

IS

O R

Y I N

D

IC

A T

IO

N

P A

N E

L /A

N N

U N

C

IA

T O

R T

R O

U B

L E

I N

D

IC

A T

IO

N

A U

D

IB

L E

A L A

R

S

E

Q U

E N

C E

V

IS

U A

L A

L A

R

E

Q U

E N

C E

FIRE ALARM PANEL, TRANSPONDER, NAC PANEL

LOW BATTERY

FIRE ALARM PANEL, TRANSPONDER, NAC PANEL

BATTERY OR CHARGER FAILURE

FIRE ALARM PANEL, TRANSPONDER, NAC PANEL

ABNORMAL SWITCH OR CONTROL POSITION.

FIRE ALARM PANEL, TRANSPONDER, NAC PANEL

GROUND FAULT, OPEN CIRCUIT, SHORT CIRCUIT

FIRE ALARM PANEL, TRANSPONDER, NAC PANEL

AC POWER LOSS OR IRREGULARITY

INITIATING DEVICE

FAILURE OR COMMUNICATION ERROR

FIRE ALARM PANEL

MANUAL FIRE DRILL

SMOKE DETECTOR

NOTIFICATION APPLIANCE CIRCUIT OR SLC LOOP

GROUND FAULT, OPEN CIRCUIT, SHORT CIRCUIT

HEAT DETECTOR

SMOKE DETECTOR

FOR HVAC CONTROL

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

NOTES:

1. ALL SYSTEM EVENTS SHALL BE LOGGED. SEE SPECIFICATIONS FOR MORE

INFORMATION AND DESCRIPTIONS OF SEQUENCES OF OPERATION.

SS

S

HH

H

SS

S S

HH

A H

U

M E

C H

A N

IC

A

L F

A N

H U

T D

O W

N S

E Q

U E

N C

E

X

GAS DETECTOR

XMM

# # X X

A C

C E

S S

C O

N T

R O

L

O V

E R

R

ID

E S

E Q

U E

N C

E

X

X

X

FIRE ALARM SHEET INDEX

FA000 FIRE ALARM COVERSHEET

FA001 LOWER LEVEL DEMOLITION PLAN - FIRE ALARM

FA002 FIRST LEVEL DEMOLITION PLAN - FIRE ALARM

FA100 LOWER LEVEL PLAN - FIRE ALARM

FA101 FIRST LEVEL PLAN - FIRE ALARM

GRAND TOTAL: 5

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:4

A

M

FA000

FIRE ALARM COVERSHEET

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 JDD SAC

BID DOCUMENTS

18704

NO SCALE1

FIRE ALARM RISER

NO SCALE2

FIRE ALARM OPERATION MATRIX

Revisions: Date: EXPIRES 4/30/2028VA F

O

ARCHITECT/ENGINEER OF RECORDCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789

STAMP

U.S. Department of Veterans Affairs

Office of Design and Construction

Services

EXPIRES 4/30/2028

F

S

H

C

G

F

E

D

3 4 5

4.1 5.1

3.1

D.1

EXISTING PANEL A

EXISTING FIRE ALARM CONTROL

PANEL (SIEMENS DESIGO)

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:4

A

M

FA001

LOWER LEVEL DEMOLITION PLAN -

FIRE ALARM

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 JDD SAC

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

LOWER LEVEL DEMOLITION PLAN - FIRE ALARM

SHEET NOTES:

1. REFER TO FA000 FOR FIRE ALARM RENOVATION

NOTES, FIRE ALARM INSTALLATION NOTES AND

VIEW KEY.

2. CONTRACTOR TO PATCH AND PAINT THE

DAMAGED WALL/CEILING AREAS AND

ABANDONED OPENINGS AS REQUIRED TO

MATCH THE ORIGINAL CONSTRUCTION AFTER

DEMOLITION.

3. EXISTING CONDUIT TO BE ABANDONED SHALL

BE REMOVED IF EXPOSED.

Revisions: Date: EXPIRES 4/30/2028VA F

O

ARCHITECT/ENGINEER OF RECORDCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789

STAMP

U.S. Department of Veterans Affairs

Office of Design and Construction

Services

S S

F

F

S

S

S

S

F

S S

F

S

S

F

S

H

C

G

F

E

D

3 4 5

4.1 5.1

3.1

D.1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

A

M

FA002

FIRST LEVEL DEMOLITION PLAN -

FIRE ALARM

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 JDD SAC

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

FIRST LEVEL DEMOLITION PLAN - FIRE ALARM

SHEET NOTES:

1. REFER TO FA000 FOR FIRE ALARM RENOVATION

NOTES, FIRE ALARM INSTALLATION NOTES AND

VIEW KEY.

2. CONTRACTOR TO PATCH AND PAINT THE

DAMAGED WALL/CEILING AREAS AND

ABANDONED OPENINGS AS REQUIRED TO

MATCH THE ORIGINAL CONSTRUCTION AFTER

DEMOLITION.

3. EXISTING CONDUIT TO BE ABANDONED SHALL

BE REMOVED IF EXPOSED.

Revisions: Date: EXPIRES 4/30/2028VA F

O

ARCHITECT/ENGINEER OF RECORDCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789

STAMP

U.S. Department of Veterans Affairs

Office of Design and Construction

Services

F

F

S

S

H

HF

F

F

F

S

F

S

S S

C M

C M

H

C

G

F

E

D

B

A

2.1

4 5

4.1 5.1

3.1

D.1

ELECTRICAL

B04

TR

B03

BASEMENT

B02

BASEMENT

B01

STAIRS

B05

E1

EXISTING PANEL A

EXISTING FIRE ALARM CONTROL

PANEL (SIEMENS DESIGO)

AHU-01 RETURN

AHU-01 SUPPLY

E4

E3

AHU-01

E2

CO

ACCESS CONTROL

SYSTEM

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

A

M

FA100

LOWER LEVEL PLAN - FIRE ALARM

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 JDD SAC

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

LOWER LEVEL PLAN - FIRE ALARM

KEYNOTES

E1 MOUNT SMOKE DETECTOR WITHIN 5'-0" OF

EXISTING FIRE ALARM CONTROL PANEL.

E2 PROVIDE FIRE ALARM CONTROL MODULE WITHIN

HVAC UNIT CONTROL CABINET. COORDINATE

EXACT MOUNTING LOCATION WITH M.C. RELAY

SHALL PROVIDE SIGNAL TO SHUTDOWN HVAC

UNIT. MOUNT WITHIN 3'-0" OF CONTROLLER.

E3 MOUNT DUCT TYPE SMOKE DETECTOR ABOVE

ACCESSIBLE CEILING IN RETURN DUCT AHEAD

OF LAST DUCT TAP.

E4 MOUNT DUCT TYPE SMOKE DETECTOR ABOVE

ACCESSIBLE CEILING IN SUPPLY DUCT AHEAD OF

FIRST DUCT TAP.

SHEET NOTES:

1. REFER TO FA000 FOR GENERAL FIRE ALARM

EQUIPMENT SCHEDULE, FIRE ALARM

INSTALLATION NOTES AND VIEW KEY.

2. REFER TO 1/FA000 FOR FIRE ALARM

RISER AND 2/FA000 FOR FIRE ALARM

OPERATION MATRIX.

3. PROVIDE ARCHITECTURAL SURFACE RACEWAY

TO INSTALL THE NEW DEVICE ON EXISTING

WALL AND CEILING IN PUBLIC FINISHED SPACES

WHERE WALLS ARE FINISHED. IF APPLICABLE,

THE CONTRACTOR IS ALLOWED TO INSTALL

NEW DEVICE IN EXISTING RECESSED BACKBOX

AND UTILIZE EXISTING CONCEALED CONDUIT TO

RUN NEW WIRING.

Revisions: Date: EXPIRES 4/30/2028VA F

O

ARCHITECT/ENGINEER OF RECORDCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST ESTIMATING:GEOTECHNICAL:

TERRACON

15620 W 113th St Lenexa, KS 66219

(913) 202-7598

OCMI

2100 North Greenville Ave. #1150 Richardson, TX 75082

(469) 431-0571

TECHNOLOGY:

IMEG

900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258

(480) 222-3789

STAMP

U.S. Department of Veterans Affairs

Office of Design and Construction

Services

S

F

F

15 15

S S

F

S

F

S

F

F

F

F

F

S

S

S S

F

S

F

S

S

S S

S

S S

S

H

F

F

H

C

G

F

E

D

B

A

2.1

4 5

4.1 5.1

3.1

D.1

ASSISTANT DIRECTOR

PROGRAM ANALYST

BUDGET ANALYST

OPERATIONAL CTR

DIRECTOR

STAFF MEN

114A STAFF WOMEN

113A

ADMIN OFFICER

MULTIPURPOSE ROOM

HAC

MENS

WOMENS

LOBBY

HALLWAY

STORAGE

HALLWAY

105c

WORKSTATIONS

HALLWAY

105b

BREAK ROOM

MENS LOCKER ROOM

WOMENS LOCKER ROOM

CO

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

Phase

STAMPCONSULTANT ARCHITECT/ENGINEER OF RECORD

2100 North Greenville Ave. #1150

Richardson, TX 75082

(469) 431-0571

BID DOCUMENTS

400 5th St

West Des Moines, IA 50265

(515) 225-6265

9000 E. Prima Ctr Pkwy #320

Scottsdale, AZ 85258

(480) 222-3789

15620 W 113th St

Lenexa, KS 66219

(913) 202-7598

TERRACON EC DESIGN IMEG OCMI

GEOTCHNICAL: IRRIGATION: TECHNOLOGY: COST ESTIMATING:

OPTIONAL BID #1

A u to d e s k D o c s /2

.0

N C

A C a m p L e a v e n w o rt h G ra v e s it e

E x p a n s io n /E

T

.0

N

C A

C a m p L e a v e n w o rt h

G ra v e s it e E x p a n s io n C

.r v t

/1

/2

:5

:5

A

M

FA101

FIRST LEVEL PLAN - FIRE ALARM

LEAVENWORTH NATIONAL CEMETERY

GRAVESITE EXPANSION

150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048

897CM3025

JUNE 22, 2026 JDD SAC

BID DOCUMENTS

18704

N O R

HT

1/4" = 1'-0"1

FIRST LEVEL PLAN - FIRE ALARM

SHEET NOTES:

1. REFER TO FA000 FOR GENERAL FIRE ALARM

EQUIPMENT SCHEDULE, FIRE ALARM

INSTALLATION NOTES AND VIEW KEY.

2. REFER TO 1/FA000 FOR FIRE ALARM

RISER AND 2/FA000 FOR FIRE ALARM

OPERATION MATRIX.

3. PROVIDE ARCHITECTURAL SURFACE RACEWAY

TO INSTALL THE NEW DEVICE ON EXISTING

WALL AND CEILING IN PUBLIC FINISHED SPACES

WHERE WALLS ARE FINISHED. IF APPLICABLE,

THE CONTRACTOR IS ALLOWED TO INSTALL

NEW DEVICE IN EXISTING RECESSED BACKBOX

AND UTILIZE EXISTING CONCEALED CONDUIT TO

RUN NEW WIRING.

Revisions: Date: EXPIRES 4/30/2028VA F

O

ARCHITECT/ENGINEER OF RECORDCONSULTANT

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704Date:

IRRIGATION:

EC DESIGN

400 5th St West Des Moines, IA 50265

(515) 225-6265

COST…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .