_19 LNC BD - SIGNAGE FURNISHINGS pt2 (pg 126-138).pdf
PDF 15 MB Posted
- Solicitation number
- 36C78626B0027
About this file
Summary
This document comprises Signage and Furnishings Details (sheets LK501-LK508) from the Leavenworth National Cemetery Gravesite Expansion project, a U.S. Department of Veterans Affairs construction project located at 150 Muncie Road, Leavenworth, Kansas 66048. The bid documents were issued June 22, 2026, by Anderson Engineering of Minnesota, LLC (Project #18704). The drawings establish detailed specifications and installation requirements for cemetery signage, watering stations, benches, and related site furnishings.
The signage work involves removal and replacement of existing cemetery signs throughout multiple sections, including temporary construction signs (SP-24.01, SP-24.04), visitors information and floral regulations signs (NC-01.01-A-c2, NC-01.01-B-c2), traffic regulatory signs (NC-03.02-c2), accessible parking signs (NC-03.09), post and panel signage (NC-04.01-c2, NC-04.02-c2, NC-04.03-c2), and section markers (NC-07.01-c2). All signage must comply with VA Signage Design Guide standards. The work includes complete demolition of existing sign assemblies (posts, supports, brackets, footings, anchors, hardware) with waste removal from cemetery property. New signage requires field staking and verification with cemetery staff prior to installation. Additional furnishings include replacement of flower watering station signage, installation of new benches with concrete pads and anchoring systems, and replacement of military service seals in an existing granite wall with new seals in updated locations (Army, Marine Corps, Navy, Air Force, Space Force, and Coast Guard). All coordinate work with irrigation systems, landscaping, and underground utilities per city guidelines.
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
A
N
0 30' 60'
SCALE:1
SIGNAGE & FURNISHINGS PLAN 8
1" = 30'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O R
M
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge th ru
.d w g ed it:
bn or he im s av ed :6
/1 8/
:4
AM
p lo t:6 /2
2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
KEY MAP N.T.S.
Office of Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK109
SIGNAGE & FURNISHINGS PLAN 8
MATCHLINE - SEE SHEET LK111
M
ATC
H
LIN
E - SEE SH
EET LK108
MATCHLINE - SEE SHEET LK107
REPLACE EX.
NC-01.01-c2 SIGN
SEE DETAIL 1/LK503
SIDE A: LAYOUT B
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
BNJF
EX. SECTION
58A
EX. SECTION
EX.
SECTION 57
EX.
SECTION 56
EX.
SECTION 48
EX.
SECTION
53A
EX. SECTION 54 EX. SECTION 55
OVERLOOK RD
CEM
ETERY RD
LEGEND
PROPERTY LIMITS
EXISTING FLOWER WATERING
STATION TO REMAIN
EXISTING SIGNS
NEW 2-PANEL SIGNAGE
NEW 1-PANEL SIGNAGE
NATIONAL CEMETERY SIGNAGE KEY:
NC - 04 . 02 - B - M1 (A)
PROJECT SIGN PLACARD #
POST STYLE / FAMILY
SIGN CONFIGURATION /
VIEW / LAYOUT
SIGN SIZE (SPECIFIC TO TYPE)
SIGN TYPE
NATIONAL CEMETERY
SIGN DESIGNATION
STREET SIGN LAYOUT KEY
FOR LETTERS
DEPICTED ON
PANELS, REFER TO
DETAIL 1/LK502
A
A
B B
A A B
A
LK103 LK104
LK105 LK106 LK107
LK108 LK109
LK110 LK111
LK112 LK113
LK102
A
B A
NOTES
1. ALL NOTED SIGNAGE TO BE REMOVED AND
REPLACED IN FULL, EXCEPT FOR INSTANCES
DESIGNATED TO REMAIN. ALL WASTE TO BE
REMOVED FROM CEMETERY PROPERTY.
2. REMOVAL OF EXISTING SIGNAGE INCLUDES
COMPLETE REMOVAL OF ENTIRE ASSEMBLY
INCLUDING SIGN FACE, POSTS, SUPPORTS,
BRACKETS, FOUNDATIONS/FOOTINGS,
ANCHORS, BASE PLATES, MOUNTING
HARDWARE, AND ALL OTHER ASSOCIATED
COMPONENTS. NO PORTION OF EXISTING
SIGNS SHOWN AS REMOVED IS TO REMAIN IN
PLACE UNLESS SPECIFICALLY NOTED
3. ALL NEW SIGNAGE TO BE STAKED IN FIELD
PRIOR TO INSTALLING AND VERIFIED WITH
CEMETERY STAFF FOR LOCATION.
4. ALL EXISTING SIGNAGE TO BE REPLACED
MUST BE FIELD LOCATED BY CONTRACTOR
AND VERIFIED BY COR.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR
ALL NATIONAL CEMETERY SIGNS.
SIGNAGE NOTES
TEMPORARY CONSTRUCTION - SEE 1/LK501
SIGN TYPES:
· SP-24.01
· SP-24.04
VISITORS INFO. / FLORAL REGS. - SEE 1/LK503
SIGN TYPES:
· NC-01.01-A-c2
· NC-01.01-B-c2
TRAFFIC REGULATORY - SEE 3/LK502
SIGN TYPES:
· NC-03.02-c2
ACCESSIBLE PARKING - SEE 4/LK502
SIGN TYPES:
· NC-03.09
POST & PANEL - SEE 2 & 3/LK503, 4/LK505
SIGN TYPES:
· NC-04.01-c2
· NC-04.02-c2
· NC-04.03-c2
SECTION MARKER - SEE 2/LK502
SIGN TYPES:
· NC-07.01-c2
STAMP
Xr ef
C :\U se rs
\lc am po ve rd e-lo ay za \D ow nl oa ds
\1
-A
-R
Fl oo r P la n
- F
IR
ST
L
EV
EL
P
LA
N -E le ct ric al
-2
3-rv t-1 -F
IR
ST
L
EV
EL
P
LA
N
.d w g
Xr ef
C :\U se rs
\lc am po ve rd e-lo ay za \D ow nl oa ds
\1
-A
-R
Fl oo r P la n
- F
IR
ST
L
EV
EL
P
LA
N -M ec ha ni ca l-2
3-rv t-1 -F
IR
ST
L
EV
EL
P
LA
N
.d w g
Xr ef
C :\U se rs
\lc am po ve rd e-lo ay za \D ow nl oa ds
\1
-A
-R
Fl oo r P la n
- F
IR
ST
L
EV
EL
P
LA
N -S tru ct ur al
-2
3-rv t-1 -F
IR
ST
L
EV
EL
P
LA
N
.d w g
Xr ef
C :\U se rs
\lc am po ve rd e-lo ay za \D ow nl oa ds
\1
-A
-R
Fl oo r P la n
- F
IR
ST
L
EV
EL
P
LA
N -1
_M
EP
_R
-rv t-1
-F
IR
ST
L
EV
EL
P
LA
N .d w g
B6
SS
SS
B6
B6
AE
A
A
A
A A A
B A
A
A
A A
A
A
N
0 30' 60'
SCALE:1
SIGNAGE & FURNISHINGS PLAN 9
1" = 30'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge th ru
.d w bn or av ed :6
/1 8/
:4 lo t:6 /2
2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
KEY MAP N.T.S.
Office of Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK110
SIGNAGE & FURNISHINGS PLAN 9
MATCHLINE - SEE SHEET LK113
MATCHLINE - SEE SHEET LK108
REPLACE EX.
NC-03.02 SIGNS
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
SALVAGE AND RELOCATE
EX. NC-3.02 SIGN
SEE DETAIL 3/LK502
LAYOUT K
REMOVE EX.
NC-3.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT L
REPLACE EX.
NC-04.02-c2 SIGN
SEE DETAIL 3/LK503
SIDE A: LAYOUT I
REMOVE EX.
NC-03.09 SIGN
SEE DETAIL 4/LK502
SIDE A: LAYOUT A
REMOVE EX.
NC-04.02-c2 SIGN
SALVAGE AND RELOCATE EX.
LEAVENWORTH NATIONAL CEMETERY KIOSK
SIDE A: DETAIL 3/LK508
SALVAGE AND REINSTALL EX.
ULTIMATE SACRIFICE PLAQUE
SIDE A: DETAIL 1/LK508
REINSTALL IN SAME LOCATION
REPLACE EX.
DOUBLE-SIDED
NC-04.02-c2 SIGN
SEE DETAIL 3/LK503
SIDE A: LAYOUT H
SIDE B: LAYOUT M
SALVAGE AND REINSTALL
NATIONAL HISTORICAL
LANDMARK PLAQUE
SIDE A: DETAIL 2/LK508
REINSTALL IN SAME
LOCATION
EX. NEIGHING TROOP PLAQUE
TO REMAIN
NEW NC-03.02 SIGN
SEE DETAIL 3/LK502
LAYOUT B
M
AT
C H
LI
N
E
- S
EE
S
H
EE
T
LK
BNJF
EX.
SECTION 46
EX.
SECTION 49
EX.
SECTION 36
EX.
SECTION 35
EX.
SECTION 40EX.
SECTION 41
EX.
SECTION 37
EX. SECTION
53A
CE
M
ET
ER
Y
RD
C O
O
KE D
R
CEMETERY RD
REPLACE EX.
FLOWER WATERING STATION SIGNAGE
SEE DETAIL 2/LK505
NATIONAL CEMETERY SIGNAGE KEY:
NC - 04 . 02 - B - M1 (A)
PROJECT SIGN PLACARD #
POST STYLE / FAMILY
SIGN CONFIGURATION /
VIEW / LAYOUT
SIGN SIZE (SPECIFIC TO TYPE)
SIGN TYPE
NATIONAL CEMETERY
SIGN DESIGNATION
STREET SIGN LAYOUT KEY
FOR LETTERS
DEPICTED ON
PANELS, REFER TO
DETAIL 1/LK502
A
A
B B
NEW NC-03.09 SIGNS
SEE DETAIL 4/LK502
SIDE A: LAYOUT A
LEGEND
PROPERTY LIMITS
EXISTING FLOWER WATERING
STATION TO REMAIN
NEW FLOWER WATERING STATION
SEE DETAIL 1/LK505
NEW BENCH SEE DETAIL 2/CB501
EXISTING SIGNS
NEW 2-PANEL SIGNAGE
NEW 1-PANEL SIGNAGE
A A B
A
LK103 LK104
LK105 LK106 LK107
LK108 LK109
LK110 LK111
LK112 LK113
LK102
A
B A
NOTES
1. ALL NOTED SIGNAGE TO BE REMOVED AND
REPLACED IN FULL, EXCEPT FOR INSTANCES
DESIGNATED TO REMAIN. ALL WASTE TO BE
REMOVED FROM CEMETERY PROPERTY.
2. REMOVAL OF EXISTING SIGNAGE INCLUDES
COMPLETE REMOVAL OF ENTIRE ASSEMBLY
INCLUDING SIGN FACE, POSTS, SUPPORTS,
BRACKETS, FOUNDATIONS/FOOTINGS,
ANCHORS, BASE PLATES, MOUNTING
HARDWARE, AND ALL OTHER ASSOCIATED
COMPONENTS. NO PORTION OF EXISTING
SIGNS SHOWN AS REMOVED IS TO REMAIN IN
PLACE UNLESS SPECIFICALLY NOTED
3. ALL NEW SIGNAGE TO BE STAKED IN FIELD
PRIOR TO INSTALLING AND VERIFIED WITH
CEMETERY STAFF FOR LOCATION.
4. ALL EXISTING SIGNAGE TO BE REPLACED
MUST BE FIELD LOCATED BY CONTRACTOR
AND VERIFIED BY COR.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR
ALL NATIONAL CEMETERY SIGNS.
SIGNAGE NOTES
TEMPORARY CONSTRUCTION - SEE 1/LK501
SIGN TYPES:
· SP-24.01
· SP-24.04
VISITORS INFO. / FLORAL REGS. - SEE 1/LK503
SIGN TYPES:
· NC-01.01-A-c2
· NC-01.01-B-c2
TRAFFIC REGULATORY - SEE 3/LK502
SIGN TYPES:
· NC-03.02-c2
ACCESSIBLE PARKING - SEE 4/LK502
SIGN TYPES:
· NC-03.09
POST & PANEL - SEE 2 & 3/LK503, 4/LK505
SIGN TYPES:
· NC-04.01-c2
· NC-04.02-c2
· NC-04.03-c2
SECTION MARKER - SEE 2/LK502
SIGN TYPES:
· NC-07.01-c2
REINSTALL SALVAGED
LEAVENWORTH NATIONAL CEMETERY KIOSK
SIDE A: DETAIL 3/LK508
KEY NOTES
NEW 6' BENCH WITH BACK SEE DETAIL
2/LK507
OBELISK
OFFICERS
A
A
A
N
0 30' 60'
SCALE:1
SIGNAGE & FURNISHINGS PLAN 10
1" = 30'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge th ru
.d w bn or av ed :6
/1 8/
:4 lo t:6 /2
2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
KEY MAP N.T.S.
Office of Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK111
SIGNAGE & FURNISHINGS PLAN 10
M
ATC
H
LIN
E - SEE SH
EET LK110
MATCHLINE - SEE SHEET LK109
REPLACE EX.
NC-01.01-c2 SIGN
SEE DETAIL 1/LK503
SIDE A: LAYOUT B
EX. MORROWS STRIFE PLAQUE
TO REMAIN
EX. FOES ADVANCE PLAQUE
TO REMAIN
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT E
EX. NATIONAL CEMETERY SYSTEM KIOSK
TO REMAIN
BNJF
REPLACE EX.
FLOWER WATERING STATION SIGNAGE
SEE DETAIL 2/LK505
EX.
SECTION
53A EX.
SECTION 54
EX.
SECTION 55
EX.
SECTION 46
EX.
SECTION 31
EX.
SECTION 30
EX.
SECTION 28 EX.
SECTION 25
EX.
SECTION 27
EX.
SECTION 29
EX.
SECTION 26
EX.
SECTION 22
EX.
SECTION 19
EX.
SECTION 16
EX.
SECTION
43A
EX.
SECTION 43
EX.
SECTION 44
EX.
SECTION 1
EX.
SECTION 45
OVERLO
OK R
D
S OBELISK RD
CEMETERY RD
GRANITE SERVICE SEALS WALL
WITH BRONZE SEALS TO BE
REPLACED; SEE DETAIL 1/LK506
LEGEND
PROPERTY LIMITS
EXISTING FLOWER WATERING
STATION TO REMAIN
EXISTING SIGNS
NEW 2-PANEL SIGNAGE
NEW 1-PANEL SIGNAGE
NATIONAL CEMETERY SIGNAGE KEY:
NC - 04 . 02 - B - M1 (A)
PROJECT SIGN PLACARD #
POST STYLE / FAMILY
SIGN CONFIGURATION /
VIEW / LAYOUT
SIGN SIZE (SPECIFIC TO TYPE)
SIGN TYPE
NATIONAL CEMETERY
SIGN DESIGNATION
STREET SIGN LAYOUT KEY
FOR LETTERS
DEPICTED ON
PANELS, REFER TO
DETAIL 1/LK502
A
A
B B
A A B
A
LK103 LK104
LK105 LK106 LK107
LK108 LK109
LK110 LK111
LK112 LK113
LK102
A
B A
NOTES
1. ALL NOTED SIGNAGE TO BE REMOVED AND
REPLACED IN FULL, EXCEPT FOR INSTANCES
DESIGNATED TO REMAIN. ALL WASTE TO BE
REMOVED FROM CEMETERY PROPERTY.
2. REMOVAL OF EXISTING SIGNAGE INCLUDES
COMPLETE REMOVAL OF ENTIRE ASSEMBLY
INCLUDING SIGN FACE, POSTS, SUPPORTS,
BRACKETS, FOUNDATIONS/FOOTINGS,
ANCHORS, BASE PLATES, MOUNTING
HARDWARE, AND ALL OTHER ASSOCIATED
COMPONENTS. NO PORTION OF EXISTING
SIGNS SHOWN AS REMOVED IS TO REMAIN IN
PLACE UNLESS SPECIFICALLY NOTED
3. ALL NEW SIGNAGE TO BE STAKED IN FIELD
PRIOR TO INSTALLING AND VERIFIED WITH
CEMETERY STAFF FOR LOCATION.
4. ALL EXISTING SIGNAGE TO BE REPLACED
MUST BE FIELD LOCATED BY CONTRACTOR
AND VERIFIED BY COR.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR
ALL NATIONAL CEMETERY SIGNS.
SIGNAGE NOTES
TEMPORARY CONSTRUCTION - SEE 1/LK501
SIGN TYPES:
· SP-24.01
· SP-24.04
VISITORS INFO. / FLORAL REGS. - SEE 1/LK503
SIGN TYPES:
· NC-01.01-A-c2
· NC-01.01-B-c2
TRAFFIC REGULATORY - SEE 3/LK502
SIGN TYPES:
· NC-03.02-c2
ACCESSIBLE PARKING - SEE 4/LK502
SIGN TYPES:
· NC-03.09
POST & PANEL - SEE 2 & 3/LK503, 4/LK505
SIGN TYPES:
· NC-04.01-c2
· NC-04.02-c2
· NC-04.03-c2
SECTION MARKER - SEE 2/LK502
SIGN TYPES:
· NC-07.01-c2
SEALS WALL EXISTING CONDITIONS
FOR INFORMATION ONLY
A
A
A
A
N
0 30' 60'
SCALE:1
SIGNAGE & FURNISHINGS PLAN 11
1" = 30'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge th ru
.d w bn or av ed :6
/1 8/
:4 lo t:6 /2
2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
KEY MAP N.T.S.
Office of Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK112
SIGNAGE & FURNISHINGS PLAN 11
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT B
REPLACE EX.
NC-3.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT N
REPLACE EX.
NO FIREARMS SIGN
SEE DETAIL 4/LK502
SIDE A: LAYOUT E
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
REPLACE EX.
NC-01.01-c2 SIGN
SEE DETAIL 1/LK503
SIDE A: LAYOUT A
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
M
AT
C H
LI
N
E
- S
EE
S
H
EE
T
LK
BNJF
EX.
SECTION 42
CEMETERY ENTRANCE RD
MUNCIE RD
S ROWLAND RD
LEGEND
PROPERTY LIMITS
EXISTING FLOWER WATERING
STATION TO REMAIN
EXISTING SIGNS
NEW 2-PANEL SIGNAGE
NEW 1-PANEL SIGNAGE
NATIONAL CEMETERY SIGNAGE KEY:
NC - 04 . 02 - B - M1 (A)
PROJECT SIGN PLACARD #
POST STYLE / FAMILY
SIGN CONFIGURATION /
VIEW / LAYOUT
SIGN SIZE (SPECIFIC TO TYPE)
SIGN TYPE
NATIONAL CEMETERY
SIGN DESIGNATION
STREET SIGN LAYOUT KEY
FOR LETTERS
DEPICTED ON
PANELS, REFER TO
DETAIL 1/LK502
A
A
B B
A A B
A
LK103 LK104
LK105 LK106 LK107
LK108 LK109
LK110 LK111
LK112 LK113
LK102
A
B A
NOTES
1. ALL NOTED SIGNAGE TO BE REMOVED AND
REPLACED IN FULL, EXCEPT FOR INSTANCES
DESIGNATED TO REMAIN. ALL WASTE TO BE
REMOVED FROM CEMETERY PROPERTY.
2. REMOVAL OF EXISTING SIGNAGE INCLUDES
COMPLETE REMOVAL OF ENTIRE ASSEMBLY
INCLUDING SIGN FACE, POSTS, SUPPORTS,
BRACKETS, FOUNDATIONS/FOOTINGS,
ANCHORS, BASE PLATES, MOUNTING
HARDWARE, AND ALL OTHER ASSOCIATED
COMPONENTS. NO PORTION OF EXISTING
SIGNS SHOWN AS REMOVED IS TO REMAIN IN
PLACE UNLESS SPECIFICALLY NOTED
3. ALL NEW SIGNAGE TO BE STAKED IN FIELD
PRIOR TO INSTALLING AND VERIFIED WITH
CEMETERY STAFF FOR LOCATION.
4. ALL EXISTING SIGNAGE TO BE REPLACED
MUST BE FIELD LOCATED BY CONTRACTOR
AND VERIFIED BY COR.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR
ALL NATIONAL CEMETERY SIGNS.
SIGNAGE NOTES
TEMPORARY CONSTRUCTION - SEE 1/LK501
SIGN TYPES:
· SP-24.01
· SP-24.04
VISITORS INFO. / FLORAL REGS. - SEE 1/LK503
SIGN TYPES:
· NC-01.01-A-c2
· NC-01.01-B-c2
TRAFFIC REGULATORY - SEE 3/LK502
SIGN TYPES:
· NC-03.02-c2
ACCESSIBLE PARKING - SEE 4/LK502
SIGN TYPES:
· NC-03.09
POST & PANEL - SEE 2 & 3/LK503, 4/LK505
SIGN TYPES:
· NC-04.01-c2
· NC-04.02-c2
· NC-04.03-c2
SECTION MARKER - SEE 2/LK502
SIGN TYPES:
· NC-07.01-c2
A
A
A
A
A A
A
A
A
A
A A
A A
A
A
N
0 30' 60'
SCALE:1
SIGNAGE & FURNISHINGS PLAN 12
1" = 30'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge th ru
.d w bn or av ed :6
/1 8/
:4 lo t:6 /2
2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
KEY MAP N.T.S.
Office of Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK113
130BNJF
SIGNAGE & FURNISHINGS PLAN 12
M
ATC
H
LIN
E - SEE SH
EET LK112
MATCHLINE - SEE SHEET LK110
REPLACE EX.
NC-01.01-c2 SIGN
SEE DETAIL 1/LK503
SIDE A: LAYOUT B
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT E
REPLACE EX.
NC-04.02-c2 SIGN
SEE DETAIL 3/LK503
SIDE A: LAYOUT K
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
REPLACE EX.
NC-04.02-c2 SIGN
SEE DETAIL 3/LK503
SIDE A: LAYOUT J
REPLACE EX.
NC-04.01-c2 SIGN
SEE DETAIL 2/LK503
SIDE A: PANEL D
REPLACE EX.
NC-03.02 SIGN
SEE DETAIL 3/LK502
LAYOUT D
REPLACE EX.
NC-03.02 SIGNS
SEE DETAIL 3/LK502
SIDE A: LAYOUT C
REPLACE EX.
NC-04.01-c2 SIGN
SEE DETAIL 2/LK503
SIDE A: PANEL C
EX. REST ON PLAQUE TO REMAIN
PROJECT CONSTRUCTION SIGN
SIDE A: DETAIL 1/LK501
SAFETY AND CONSTRUCTION SIGN
SIDE A: DETAIL 2/LK501
NEW NC-03.02 SIGN
SEE DETAIL 3/LK502
LAYOUT A
REINSTALL SALVAGED
NC-3.02 SIGN
SEE DETAIL 3/LK502
LAYOUT K
NEW NC-04.03-c2 SIGN
SEE DETAIL 4/LK505
SIDE A: LAYOUT A
NEW NC-04.02-c2 SIGN
SEE DETAIL 3/LK503
LAYOUT A
CSS 2
CSS 1
EX.
SECTION 42
EX.
SECTION
42A
EX.
SECTION
41A
EX.
SECTION 32
EX.
SECTION 33
EX.
SECTION 34
EX.
SECTION 38
EX.
SECTION 37
EX.
SECTION 40
EX.
SECTION 39
EX.
SECTION 41
EX.
SECTION 41
CREMAINS
CEMETERY ENTRANCE RD
CEMETERY RD
COOKE DR
NEW FLOWER WATERING STATION
SEE DETAIL 1/LK505
LEGEND
PROPERTY LIMITS
EXISTING FLOWER WATERING
STATION TO REMAIN
EXISTING SIGNS
NEW 2-PANEL SIGNAGE
NEW 1-PANEL SIGNAGE
NATIONAL CEMETERY SIGNAGE KEY:
NC - 04 . 02 - B - M1 (A)
PROJECT SIGN PLACARD #
POST STYLE / FAMILY
SIGN CONFIGURATION /
VIEW / LAYOUT
SIGN SIZE (SPECIFIC TO TYPE)
SIGN TYPE
NATIONAL CEMETERY
SIGN DESIGNATION
STREET SIGN LAYOUT KEY
FOR LETTERS
DEPICTED ON
PANELS, REFER TO
DETAIL 1/LK502
A
A
B B
A A B
A
LK103 LK104
LK105 LK106 LK107
LK108 LK109
LK110 LK111
LK112 LK113
LK102
A
B A
NOTES
1. ALL NOTED SIGNAGE TO BE REMOVED AND
REPLACED IN FULL, EXCEPT FOR INSTANCES
DESIGNATED TO REMAIN. ALL WASTE TO BE
REMOVED FROM CEMETERY PROPERTY.
2. REMOVAL OF EXISTING SIGNAGE INCLUDES
COMPLETE REMOVAL OF ENTIRE ASSEMBLY
INCLUDING SIGN FACE, POSTS, SUPPORTS,
BRACKETS, FOUNDATIONS/FOOTINGS,
ANCHORS, BASE PLATES, MOUNTING
HARDWARE, AND ALL OTHER ASSOCIATED
COMPONENTS. NO PORTION OF EXISTING
SIGNS SHOWN AS REMOVED IS TO REMAIN IN
PLACE UNLESS SPECIFICALLY NOTED
3. ALL NEW SIGNAGE TO BE STAKED IN FIELD
PRIOR TO INSTALLING AND VERIFIED WITH
CEMETERY STAFF FOR LOCATION.
4. ALL EXISTING SIGNAGE TO BE REPLACED
MUST BE FIELD LOCATED BY CONTRACTOR
AND VERIFIED BY COR.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR
ALL NATIONAL CEMETERY SIGNS.
SIGNAGE NOTES
TEMPORARY CONSTRUCTION - SEE 1/LK501
SIGN TYPES:
· SP-24.01
· SP-24.04
VISITORS INFO. / FLORAL REGS. - SEE 1/LK503
SIGN TYPES:
· NC-01.01-A-c2
· NC-01.01-B-c2
TRAFFIC REGULATORY - SEE 3/LK502
SIGN TYPES:
· NC-03.02-c2
ACCESSIBLE PARKING - SEE 4/LK502
SIGN TYPES:
· NC-03.09
POST & PANEL - SEE 2 & 3/LK503, 4/LK505
SIGN TYPES:
· NC-04.01-c2
· NC-04.02-c2
· NC-04.03-c2
SECTION MARKER - SEE 2/LK502
SIGN TYPES:
· NC-07.01-c2
8'-0"
6"
VA
R
IE
S
AV
ER
AG
E
3' -0
4'
-0 " M
IN
SECTION ON CENTERELEVATION
3.
5"
5" 2"
5" 8"
6" 3"
A PROJECT OF THE:
OFFICE OF CONSTRUCTION AND FACILITY MANAGEMENT
DEPARTMENT OF VETERANS AFFAIRS WASHINGTON D.C.
ANDERSON ENGINEERING
OF MN, LLC
GENERAL CONTRACTOR: ARCHITECT/ENGINEER:
3" 4"
2" 3"
3"
1.
5"
LEAVENWORTH NATIONAL CEMETERY
EXPANSION PROJECT
GENERAL CONTRACTORS
NAME HERE
BACKGROUND
TO BE PAINTED
WHITE
BORDER
MEMBER TO BE
PAINTED BLACK
METAL FACE WHITE
ENAMEL
BACKGROUND COLOR:
WHITE
LETTERING TO BE
HELVETICA STYLE 5"
HIGH
LETTERING TO BE HELVETICA
STYLE 3" HIGH
CENTERED HORIZONTALLY
2"x4" FRAME AND BRACE
IN BACK
LETTERING TO BE HELVETICA
STYLE 2" HIGH
CENTERED HORIZONTALLY
LETTERING TO BE
HELVETICA STYLE 1 1/2"
HIGH CENTERED
HORIZONTALLY
LETTERING TO BE
HELVETICA STYLE 1"
HIGH CENTERED
HORIZONTALLY
NOTES:
1. ALL LETTERING TO BE PAINTED
BLACK WITH EXCEPTION OF
PROJECT TITLE WHICH IS TO BE
BLUE.
2. ANY SEAM IN METAL TO BE FLAT
SEAM. SEAMS TO BE
HORIZONTAL AND OCCUR
BETWEEN LINES OF LETTERING.
BORDER
MEMBER TO BE
PAINTED BLACK
ENAMEL
2"x4" FRAME
AND BRACES
IN SAME
PLACE
METAL
FACE
STRETCH METAL FACE
TIGHT, TURN OVER
FRAME AND SECURE
WITH FLAT HEAD
DEFORMED NAILS
4"x4" METAL POSTS
TO BE PAINTED
WHITE
1.5"
Department of Veterans Affairs
5' -1
.5
DE
PA
RT
ME
NT OF VETERANS AFFA
IRS
UN
ITED STATES OF AMER
IC
A
CENTER TO BE WHITE
SURROUNDING
BORDER TO BE
BLACK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge d et ai ls .d w bn or av ed :6
/1 8/
0:
lo t:6
/2 2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
Office of
Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK501
131BNJF
SIGNAGE & FURNISHINGS
DETAILS 1
SCALE:1
PROJECT CONSTRUCTION SIGN DETAIL (SP-24.01)
1" = 1' SCALE:2
SAFETY AND CONSTRUCTION SIGN DETAIL (SP-24.04)
1"=1'
SIGNAGE NOTES
1. REFER TO NATIONAL CEMETERY SIGNS DESIGN GUIDE FOR ALL SIGNAGE ON CEMETERY GROUNDS.
2. ALL NON-ABA SIGNS ARE TO MAINTAIN AN UPPER AND LOWER CASE (INITIAL CAPS) FORMAT.
3. ARROWS ARE ALWAYS POSITIONED IN SUCH A MANNER THAT IT IS CENTERED IN RELATIONSHIP TO THE CAPITAL LETTER THAT IT PRECEDES. THE ARROW SIZE IS
ONE AND ONE HALF TIMES THE CAPITAL LETTER HEIGHT.
4. CONCRETE COLOR: NATURAL
5. TRAFFIC SIGN COLORS WILL COMPLY WITH U.S. DEPARTMENT OF TRANSPORTATION (DOT) STANDARD HIGHWAY SIGNS.
6. SMALLER OR LARGER FONTS THAN SHOWN ARE NOT TO BE USED. SUBMIT SHOP DRAWINGS FOR FINAL COR REVIEW AND APPROVAL.
7. POSITION SIGNS TO PROVIDE VIEWERS WITH A CLEAR, UNOBSTRUCTED VIEW OF SIGNS. POSITION PYLON SECTION MARKERS TO PROVIDE VEHICLES AND
PEDESTRIANS WITH A CLEAR, UNOBSTRUCTED VIEW OF THE SIGN. COR TO REVIEW AND VERIFY ALL FINAL SIGNAGE LOCATIONS PRIOR TO INSTALLATION.
8. ABA/ADA REGULATIONS REQUIRE BOTTOM OF NC-03.09 SIGN TO BE AT 7'-0" FROM GRADE. SEE DETAIL 4/LK503
9. SURROUND NC-07.02 SIGN FAUCET POST WITH GRAVEL OPENING TO PREVENT SPLASH FROM FAUCET. SEE DETAIL 1/LK505
10. THE VA DESIGN GUIDE FOR SIGNS ARE AVAILABLE UNDER THE DESIGN MANUALS (PG-18-10) PORTION OF THE VA TECHNICAL INFORMATION LIBRARY WHICH IS
AVAILABLE ON THE VA WEB SITE UNDER OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT. (WWW.CFM.VA.GOV/TIL/). REFER TO NATIONAL CEMETERY SIGNS
DESIGN GUIDE FOR ALL SIGNAGE ON CEMETERY GROUNDS.
11. REFER TO SIGNAGE IN THE SPECIFICATIONS, DIVISION 10, SECTION 10 14 00.
12. COORDINATE SIGN INSTALLATION WITH IRRIGATION SYSTEMS, LANDSCAPING, AND UNDERGROUND UTILITIES.
13. IN-GROUND SIGN INSTALLATION IS TO BE IN ACCORDANCE WITH CITY OF LEAVENWORTH GUIDELINES.
14. ALL FOOTINGS MUST MEET WIDTH AND DEPTH REQUIREMENTS TO ACCOMMODATE HEIGHT AND SIZE OF SIGN, SOIL CONDITIONS, WIND LOADS AND WINTER
GROUND FREEZING. REFER TO THE GEOTECHNICAL REPORT FOR MORE INFORMATION.
15. ALL SIGNS ARE TO BE LOCATED A MINIMUM OF 2'-0" FROM THE BACK OF CURB. SEE PLANS AND DETAIL 3/LK505 & 4/LK507 FOR PROPOSED PLACEMENT LOCATION, CONTRACTOR TO VERIFY FINAL SIGN PLACEMENT LOCATION AND DIRECTION WITH VA.
VA U.S. Department of Veterans Affairs
=(52 ,1
21 SA)(7<
This Project Has Worked Days
Without a Lost Time Accident
0 0 0
THE LIFE YOU SAVE MAY BE YOUR OWN
General Contractor's Firm Name
ELEVATION VIEW
PLAN VIEW
SIGN FACE
2"×4" FRAMING 4"×4" METAL POSTS
4'-0"
3' -0
4" 9"
11 2"
4"
11 2"
3' -0
4"
SECTION VIEW
CHANGEABLE NUMBERS
PROVIDE 3 SETS OF REMOVABLE
NUMERALS PAINTED ON 1/8"
TEMPERED HARDBOARD
4"×4" METAL POSTS
TO BE PAINTED WHITE
4' -0
4"
6"
1'-6"
4,000PSI CONCRETE FOOTING
18" DIA.
SLOPE TOP OF FOOTING 14" PER
FOOT AT TOP
COMPACTED SUBGRADE
RED
WHITE
BORDER MEMBER
TO BE PAINTED
BLACK ENAMEL
FINISH GRADE
2"×4" FRAME
AND BRACES IN
SAME PLACE
METAL SIGN FACE
STRETCH METAL FACE
TIGHT, TURN OVER FRAME
AND SECURE WITH FLAT
HEAD DEFORMED NAILS
4"×4" METAL POSTS
TO BE PAINTED WHITE
2"×4" FRAME AND BRACE IN
BACK
JOINT BRACING
TEMPORARY SAFETY AND
CONSTRUCTION SIGN
TO BE FIELD LOCATED.
VERIFY LOCATION WITH RE.
TEMPORARY PROJECT
CONSTRUCTION SIGN
TO BE FIELD LOCATED.
VERIFY LOCATION WITH RE.
BACKGROUND COLOR:WHITE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge d et ai ls .d w bn or av ed :6
/1 8/
0:
lo t:6
/2 2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
Office of
Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK502
132BNJF
SIGNAGE & FURNISHINGS
DETAILS 2
Text As Shown
On Details
3' -6
1' -6
2"
1"
1'-6"
2"
℄2'-0" TO BACK OF
CURB OR WALK, TYP.
EQ. EQ.
ALUMINUM SIGN PANEL; SEE
SPECIFICATIONS FOR FINISH
BACKGROUND COLOR: SHIP YARD
GREY(UNLESS NOTED OTHERWISE)
OPTIMA BOLD TYPE FACE, INITIAL
CAP AND LOWER CASE; SEE SIGN
PANEL DETAIL FOR TEXT HEIGHTS
TEXT COLOR: WHITE (UNLESS
NOTED OTHERWISE)
PRECAST CONCRETE POST;
RECESS = 4 1/4" X 11" X 3/8" DP. ALL (4) SIDES
SEE 1/LK504
1/8" RADIUS, TYP; NO SHARP EDGES
SECURE W/ 3
16" Ø X 2" SS TAMPER-PROOF
SCREWS AND EXPANSION SHIELDS
FINISHED GRADE
PRECAST CONCRETE COLLAR
SEE DETAIL 2/LK504
POST CONNECTION
Speed Limit
1'-6"
1' -6
2"
71 2"
SCALE:3
TRAFFIC REGULATORY SINGLE POST AND PANEL DETAIL (NC-3.02-c2)
1"=1'
1'-6"
1' -6
EQ EQ
EQ
EQ
1'-6"
EQ EQ
EQ
EQ
1' -6
1'-6"
1' -6
One Way
STOP
Authorized
Vehicles Only
13 4"
13 4" 13 4"
51 2"
All Funerals
Wait Here
1'-6"
1' -6
LAYOUT 'A'
1'-6"
EQ EQ
EQ
EQ
1' -6
1'-6"
EQ EQ
EQ
EQ
1' -6
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
LAYOUT 'B' LAYOUT 'C' LAYOUT 'D' LAYOUT 'E'
LAYOUT 'F' LAYOUT 'G' LAYOUT 'H'
13 4"
1'-6"
1' -0
SCALE:2
PYLON SECTION MARKER DETAIL (NC-07.01-c2)
1"=1"
SECTION MARKER PANEL (TYP.)
SCALE: 1"=4"
NUMBER VARIES
FINISHED GRADE
NOTE:
LOCATE SECTION MARKERS AT LOCATION
SHOWN ON PLANS, PARALLEL WITH BURIAL
SECTION & PERPENDICULAR TO HEADSTONE
DIRECTION.
MIN. 2'-0" TO BACK
OF CURB OR WALK
(TYP.) OR AS
SHOWN ON PLAN
1' -4
3" 7"
6"
1"
2"
4"
R2
SECURE W/ (2) 3/8"DIA. X 3" S.S. BOLT AND
EXPANSION SHIELD.
1/8" ALUMINUM SIGN PANEL, ALL 4 SIDES OF POST.
SEE PANEL LAYOUTS ABOVE. SEE 1/LK504 FOR
SIGN MOUNTING.
PRECAST CONCRETE COLLAR
SEE DETAIL 2/LK504 FOR COLLAR
SEE DETAIL 1/LK504 FOR MOUNTING
1/4" DIA. HOLES TO
RECEIVE SCREWS.
1/8" THICK ALUMINUM
SIGN PANEL.
BACKGROUND COLOR:
WELLS FARGO BLACK
COPY TO BE 2-1/4" HT.
TEXT COPY - SEE LAYOUT
PLANS FOR INDIVIDUAL
SECTION MARKER
NUMBERS.
COLOR: THE COLOR AND
FINISH SHALL BE
APPROVED IN THE
SUBMITTAL PROCESS
AND IN ACCORDANCE
WITH THE VA SIGNAGE
DESIGN GUIDE MANUAL.
PANEL A
TYPE FACE TO BE OPTIMA BOLD NARROW
Veterans M em orial D r.
1/4"Ø HOLES TO RECEIVE
SCREWS, TYP.
1/8" THICK ALUMINUM SIGN PANEL; THE
COLOR AND FINISH SHALL BE APPROVED
IN THE SUBMITTAL PROCESS AND IN
ACCORDANCE WITH THE VA SIGNAGE
DESIGN GUIDE MANUAL.
2 1/2" HT. LETTERING;
OPTIMA BOLD TYPE FACE
UNLESS NOTED OTHERWISE
1/8" ALUMINUM SIGN PANEL; ALL (4) SIDES
SEE 1/LK504
SECURE W/ 3/16" Ø X 2" SS TAMPER-PROOF
SCREWS AND EXPANSION SHIELDS
PRECAST CONCRETE POST; RECESS =
4 1/4" X 3'-0" X 3/8" DP
ALL SIDES SEE 1/LK504
SECURE W/ 3/16" Ø X 2" SS TAMPER-PROOF
SCREWS AND EXPANSION SHIELDS
FINISHED GRADE
PRECAST CONCRETE COLLAR.
SEE DETAIL 2/LK504 FOR COLLAR
SEE DETAIL 1/LK504 FOR MOUNTING
CONCRETE POST
SCALE:1
PYLON STREET MARKER 4'-0" TALL DETAIL (NC-06.01-c2)
1"=1'
PANEL B PANEL C PANEL D PANEL E
4"
3' -0
1 4"
R1 7 8"
Kansas W ay
Singer Road
Riverview A venue
C em etery Loop Road
1'-0"
1' -6
7' -0
SCALE:4
TRAFFIC REGULATORY TALL SIGN DETAIL (NC-03.09)
1"=1'
NOTES:
1. ACCESSIBLE PARKING SIGN
R7-128 STYLE SIGN TO BE
CONSISTENT WITH MUTCD R7-8
SERIES.
2. VAN ACCESSIBLE PLAQUE
TO BE MUTCD R7-8P.
NOTICE
NO FIREARMS
OR WEAPONS
ALLOWED ON
THIS PROPERTY
AUTHORIZED
PERSONNEL
ONLY
2'-6"
2' -6
1'-6"
2' -0
1'-6"
2' -0
2'-6"
1' -8
1'-6"
1' -1
0"
1'-6"
2' -3
2'-0"
1' -6
2'-0"
2' -8
Text As Shown
On Details
LAYOUT 'A'
TYPE FACE TO BE FHWA STANDARD
ALPHABET SERIES B
LAYOUT 'D'
TYPE FACE TO BE HELVETICA REGULAR
LAYOUT 'C'
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
LAYOUT 'B'
4"
NOTES:
1. NATIVE PRAIRIE
LANDSCAPE SIGN TO BE
MOUNTED ON SINGLE 5'-HT.
ALUMINUM POST
2. BACKGROUND COLOR:
CAST BRONZE
3. TEXT COLOR: WHITE
LAYOUT 'E'
TYPE FACE TO BE ARIAL
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
LAYOUT 'I'
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
LAYOUT 'J'
LAYOUT 'K'
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
LAYOUT 'L'
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
LAYOUT 'M'
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
NOTE: LAYOUT
C TYPEFACE TO
BE ARIAL
NARROW
2"
71 2" 4'
-0
6"
7"
8"
21 4"
8"
Road A
PANEL F
LAYOUT 'N'
NOTE: THIS LAYOUT
IS NOT PRESENT IN
THE NCA SIGNAGE
DESIGN GUIDE
2"
EQ
EQ
2" 2"
2" 2"
2"
EQ
EQ EQ
4"
2" 3"
3" 8"
EQ EQ EQ EQ
2"
EQ EQ
2" 3"
11 2" 3"
2" 41 2 "
2"
12"
14" 2" 2"
3"
2" 2"
3"
1' -2
2"
EQ EQ
1' -2
2"
EQ EQ
EQ
EQ
11 2" 21 2"11 2" 21 2"
EQ EQ
2" 2"
3" 2"
3" 2"
3" 2"
3"
2"
11 2"
4" 11 2"
4" 11 2"
4" 11 2"
EQ
EQ
EQ EQ
1" 2"
2" 11 2"1"
11 2"1"
11 2"1"
11 2"1"
11 2"1"
3" 1"
EQ
EQ
EQ EQ
1/
2" 3"
4" 3"
4" 3"
1/
2"
EQ. EQ.
1' -6
1'-0"
1"
3"
1"
3"
1"
1/
2"
1/ 2"
1' -6
1'-0"
1/
4"
1/
2"
1/
2"
1/ 2"
1/
2"
1/
4"
1/ 2"
EQ. EQ.
EQ. EQ.
EQ. EQ.
11 2"
31 2"
6" 11 2"
8"
18 USC § 930
11 2"
4"
11 2"
4"
11 2"
4"
11 2"
4" 1 2"1"1 2"
POST SETTING/FOOTING;
DETAIL: SEE 5/LK504
POST SETTING/FOOTING
DETAIL: SEE 5/LK504
FOOTING; SEE 5/LK504
13 4"
1'
3'
3"
NOTES:
1. LAYOUT B TYPEFACE TO
BE HELVETICA BOLD
2. BACKGROUND COLOR:
CAST BRONZE
3. TEXT COLOR: WHITE
LAYOUT 'F'
NOTES:
1. LAYOUT F SIGN TO BE
CONSISTENT WITH
MUTCD W1-8L.
2. W1-8L SIGN TO BE
MOUNTED ON SINGLE
5'-HT. ALUMINUM POST
2' -4
2'-0"
8"
BACKGROUND COLOR:
YELLOW (OSHA)
BLACK
2"
71 2" ℄
73 74 75 76
BACKGROUND COLOR: WHITE BACKGROUND COLOR: WHITE
TEXT COLOR: BLACK TEXT COLOR: BLACK
BLACK
BLACK
BACKGROUND COLOR:
CAST BRONZE
BACKGROUND COLOR:WHITE
TEXT COLOR:VA BLUE
VA BLUE
BACKGROUND COLOR:
HANDICAPPED BLUE
TEXT/SYMBOL COLOR: WHITE
BACKGROUND
COLOR: WHITE
TEXT COLOR:
RED (OSHA)
TEXT COLOR: WHITE
BACKGROUND
COLOR: WHITE
VA BLUE
RED (OSHA)
BLACK
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge d et ai ls .d w bn or av ed :6
/1 8/
0:
lo t:6
/2 2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
Office of
Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK503
133BNJF
SIGNAGE & FURNISHINGS
DETAILS 3
1-" HT. TITLE LETTERING & 5/8" HT.
BODY LETTERING, OPTIMA BOLD TYPE
FACE UNLESS NOTED OTHERWISE,
INITIAL CAP AND LOWER CASE; SEE
MESSAGE LAYOUT A & B
36" X 24" POLYCARBONATE SIGN PANEL,
1/4" THICK (MIN.), SINGLE FACE WITH
NON-GLARE MATTE FINISH W/UV
INHIBITORS, OVER ALUMINUM SIGN
PANEL. SECURE TO PANEL WITH
COUNTERSUNK STAINLESS STEEL FLAT
HEAD SCREWS APPROXIMATELY 12" O.C.
PRECAST CONCRETE POST SEE 2/LK5043'-0"
9"
2' -0
2"
1"
3' -6
2"
51 2"
SCALE:1
VISITOR INFORMATION/REGULATIONS MEDIUM SIGN DETAIL (NC-01.01-c2)
1"=1'
VISITOR INFORMATION
We welcome you to these hallowed grounds. To preserve the dignity, beauty and serenity of the cemetery, we ask you to observe our cemetery restrictions. Thank you for your cooperation.
LAYOUT A
SCALE: 1"=6"
The following activities are prohibited:
Any form of sports or recreation, including, but not limited to jogging, bicycling, skating and picnicking.
NOTE:
VISITORS INFORMATION AND FLORAL
REGULATIONS SIGN TEXT TO BE
VERIFIED AT TIME OF PROJECT NEED.
SUBMIT SHOP DRAWINGS TO VA/COR
FOR REVIEW AND APPROVAL
Text As Shown On Details
3' -6
2' -6
R
EC
ES
S
AR
EA
3'-0" ALUMINUM SIGN PANEL;
COLOR AND FINISH SHALL BE APPROVED
IN THE SUBMITTAL PROCESS AND IN
ACCORDANCE WITH THE VA SIGNAGE
DESIGN GUIDE MANUAL.
2 1/2" HT. LETTERING, OPTIMA
BOLD TYPE FACE, INITIAL CAP
AND LOWER CASE; SEE
SIGNAGE SCHEDULE FOR
COPY
PRECAST CONCRETE POST;
RECESS = 2 1/4" X 2'-6" X 3/8"
DP. (3) SIDES; NO RECESS ON
INSIDE OF POSTS
℄4'-0" TO BACK OF
CURB OR WALK, TYP.
FINISHED GRADE
PRECAST CONCRETE COLLAR
SEE DETAIL 4/LK507
8"
2"
51 2"
2" 1"
SCALE:2
POST & PANEL ONE LINE OF TEXT DETAIL (NC-04.01-c2)
1"=1'
PANEL 'A'
TYPE FACE TO BE OPTIMA BOLD NARROW
Committal Shelter 3
PANEL 'B'
Maintenance Building
PANEL 'C'
TYPE FACE TO BE OPTIMA BOLD NARROW
Committal Shelter 2
SCALE:3
POST & PANEL TWO LINES OF TEXT DETAIL (NC-04.02-c2)
1"=1'
Columbarium 1 Exit
3'-0"
1' -0
2"
1 1/2"
1 1/2" 3 3/4"
1 1/2" 3 3/4"
Text As Shown On Details
3' -6
2' -6
R
EC
ES
S
AR
EA
3'-0" ALUMINUM SIGN PANEL;
COLOR AND FINISH SHALL BE APPROVED
IN THE SUBMITTAL PROCESS AND IN
ACCORDANCE WITH THE VA SIGNAGE
DESIGN GUIDE MANUAL.
2 1/2" HT. LETTERING, OPTIMA BOLD
TYPE (FOR TEXT WITH FIT ISSUES
UTILIZE OPTIMA BOLD NARROW)
FACE UNLESS NOTED OTHERWISE,
INITIAL CAP AND LOWER CASE
PRECAST CONCRETE POST;
RECESS = 2 1/4" X 2'-6" X 3/8"
DP. (3) SIDES; NO RECESS ON
INSIDE OF POSTS; SEE 1/LK504
℄2'-0" TO BACK OF
CURB OR WALK, TYP.
FINISHED GRADE
PRECAST CONCRETE COLLAR
SEE DETAIL 4/LK507
1' -0
2"
51 2"
2" 1"
3 3/4"
LAYOUT 'A'
All Corteges
LAYOUT 'B'
TYPE FACE TO BE OPTIMA BOLD NARROW
Columbarium 1 Committal Shelter
LAYOUT 'C'
TYPE FACE TO BE OPTIMA BOLD NARROW
Columbarium 1&2 Administration
LAYOUT 'D'
TYPE FACE TO BE OPTIMA BOLD NARROW
Columbarium 1 Committal Shelter
LAYOUT 'E'
Sections 45 - 48 Sections 50 - 58
LAYOUT 'F'
Sections 45 - 48 Sections 50 - 58
LAYOUT 'G'
Exit Cemetery
LAYOUT 'H'
TYPE FACE TO BE OPTIMA BOLD NARROW
Gravesite Locator Office
LAYOUT 'I'
TYPE FACE TO BE OPTIMA BOLD NARROW
LAYOUT 'J'
Office: Restrooms Information & Parking
LAYOUT 'K'
LAYOUT 'L'
Cemetery
Exit
LAYOUT 'M'
TYPE FACE TO BE OPTIMA BOLD NARROW
Administration Grave Locator
EXAMPLE LAYOUT
FOR DIMENSIONS ONLY
PANEL 'D'
Committal Shelter 1
Exit Office
EQ. EQ.
3 3/4"4" 4"
EQ. EQ.
2"
Gravesite Locator Office
LAYOUT B
TYPEFACE TO BE OPTIMA BOLD EXTRA NARROW
SCALE: 1"=6"
LAYOUTS FOR CONSTRUCTION
Public gathering of a partisan nature.
Littering of grounds.
Cutting, breaking or injuring of trees, shrubs, grass or other plantings Allowing pets to run loose.
Boisterous actions.
CEMETERY HOURS
Sunrise to Sunset Daily
1 1/2"
PANEL 'E'
Columbarium 3
PRECAST CONCRETE COLLAR.
SEE DETAIL 4/LK507
POST SETTING/FOOTING;
DETAIL: SEE 5/LK504
POST SETTING/FOOTING
DETAIL: SEE 5/LK504
POST SETTING/FOOTING
DETAIL: SEE 5/LK504
Floral Regulations
1. Fresh cut flowers may be placed on graves at any time. Temporary metal containers are available.
2. Artificial flowers may be placed on graves during the period of October 10 through April 1.
3. Floral items will be removed from graves as soon as they become faded or unsightly.
4. Plantings will not be permitted on graves at any time. Potted plants will be permitted on graves only during the period 10 days before and after Easter Sunday and Memorial Day.
5. Christmas wreaths or grave blankets are permitted on graves during the Christmas season and will be removed not later than January 20 of each year. Grave floral blankets may not be larger than 2 by 3 feet.
6. During the lawn mowing and grounds maintenance season, all floral items will be removed from graves. Flower pick-up dates are posted on "Next Flower Pick-Up" signs posted at cemetery entrances.
7. Statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.
8. Floral items and other types of decorations will not be secured to or laid upon headstone markers or niche covers.
11 2"
4" 1 2"
1"
8"
℄ Committal Shelter 3
3'-0"
8"
EQ.
EQ.
2 1/2"
2 3/8"
EXAMPLE LAYOUT
FOR DIMENSIONS ONLY
LAYOUTS FOR
CONSTRUCTION
2 38" MIN
BACKGROUND COLOR: CAST BRONZE
TEXT COLOR: WHITE
BACKGROUND COLOR: CAST BRONZE
TEXT COLOR: WHITE
TEXT COLOR: WHITE (TYP.)
BACKGROUND COLOR:
SHIP YARD GREY (TYP.)
TEXT COLOR: WHITE (TYP.)
BACKGROUND COLOR:
SHIP YARD GREY (TYP.)
"FLORAL REGULATIONS"
HEADER TO BE OPTIMA BOLD
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge d et ai ls .d w bn or av ed :6
/1 8/
0:
lo t:6
/2 2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
Office of
Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK504
134BNJF
SIGNAGE & FURNISHINGS
DETAILS 4
EQUALEQUAL
5 12"
1/8" THICK MEDIUM BRONZE
ANODIZED FINISH ALUMINUM
PANEL BOTH SIDES
WELD TO FRAME
PAINT ALL EXPOSED SURFACES
SEE DETAILS 1,2,3/LK503
16" DIA. MINIMUM 3"
STAINLESS STEEL
BOLT AND SHIELD
PRECAST CONCRETE POST;
RECESS = 2 1/4" X 2'-6" X 3/8" DP. (3)
SIDES; NO RECESS ON INSIDE OF POSTS
SEE DETAIL 4/LK504
SCALE:6
SIGN PANEL CONNECTION DETAIL
1"=2"
SCALE:1
PRECAST CONCRETE POST SIGN PANEL MOUNTING DETAIL
1"=1"
7 1/2"
3/ 8"
R
EC
ES
S, T
YP
AL
L
SI
D
ES
1/
2"
3 3/4"
1/8"
TYP. ALUMINUM SIGN PANEL
(WHERE SHOWN)
3/16"Ø X 2" SS TAMPER
PROOF SCREW &
EXPANSION SHIELD
PRECAST CONCRETE
POST; LIGHT SANDBLAST
FINISH
4" 1/8" 1/8"
5/8" 5/8"
1"1"
7 1/2"
3/ 8"
R
EC
ES
S, T
YP
AL
L
SI
D
ES
1/
2"
(3) #3 EQUALLY
SPACED REBAR
PRECAST
CONCRETE
POST; LIGHT
SANDBLAST
FINISH
NOTE:
SEE INDIVIDUAL SIGN TYPE DETAILS
FOR 3/8" RECESS HEIGHT AND
LOCATION ON OVERALL POST
7 1/2"
1" C
H
AM
FE
R
, T
YP
(A
LL
E D
G
ES
1/
2"
4 5/8"
3/8" RECESS (BELOW);
ALL SIDES
PRECAST CONCRETE
POST; LIGHT SANDBLAST
FINISH
7 1/2"
1"
5 1/2"
PRECAST CONCRETE POST WITH 1"
CHAMFER ON ALL SIDES & TOP;
LIGHT SANDBLAST FINISH
SECTION PLAN VIEW
TOP ELEVATION
SCALE:3
PRECAST CONCRETE POST DETAIL 7 1/2"
1"=3"
PRECAST CONCRETE COLLAR; SEE
2/LK504
4,000 PSI CONCRETE
FOOTING, 18" DIA. SLOPE
TOP OF FOOTING 14" PER
FOOT AT TOP
FINISHED GRADE
COMPACTED AGGREGATE
BASE
COMPACTED SUBGRADE
TOPSOIL
SCALE:5
PRECAST CONCRETE POST SETTING DETAIL
1"=6"
SCALE:2
PRECAST CONCRETE CONCRETE COLLAR DETAIL (SINGLE POST)
1"=6"
4' -0
" M
IN
6"
M
IN
#3 REBAR,
SPACING AND
CONT. PER SPEC
PRECAST CONCRETE
COLLAR; LIGHT
SANDBLAST FINISH
2'-0"
2' -0
4"
11 4"
6"
6"
11 4"
4"
81 2 "
3" 1"
VARIES
3" 6"
3' -3
2" BACKER ROD AND SEALANT
SECTION PLAN VIEW
TOP ELEVATION
2"
2"
1"
4"
8"
8"
2"
2"
4"
4"
51 2"
1 4" (3) #3 EQUALLY
SPACED REBAR
2"
8"
51 2"
4"
1/4" RECESS (BELOW);
ALL SIDES
SCALE:4
PRECAST CONCRETE POST DETAIL 5 1/2"
1"=3"
PRECAST CONCRETE
POST; LIGHT SANDBLAST
FINISH
NOTE:
SEE INDIVIDUAL SIGN TYPE DETAILS
FOR 1/4" RECESS HEIGHT AND
LOCATION ON OVERALL POST
PRECAST CONCRETE POST WITH 1"
CHAMFER ON ALL SIDES & TOP;
LIGHT SANDBLAST FINISH
1" C
H
AM
FE
R
AL
L
ED
G
ES
PRECAST
CONCRETE
POST; LIGHT
SANDBLAST
FINISH℄
2"
EQUAL
1 8" R
EV
EA
L
1-1/4" X 1-1/2" X 1/8"
THICK ALUMINUM
CHANNEL FRAME ALL
4 SIDES MEDIUM
BRONZE ANODIZED
FINISH
1"X1" ALUMINUM TUBE 11 GAUGE
WITH
MITERED CORNERS.
WELD AND GRIND SMOOTH
PAINT ALL EXPOSED SURFACES TO
MATCH SIGN PANEL
8'-0"
3' -6
6"
3'-8" 1'-6"
1' -9
PLAN
2'-10"
6"
2'-0"
2' -0
2'-10"
UNLESS NOTED OTHERWISE
4"
6"
FLORAL
REGULATIONS
1' -1
7/
8"
1' -9
3 4"
4"
1' 2-1/2"1
4" TYP.
FLORAL REGULATIONS DECAL
CLEAR DECALS W/ VICTOR
LETTERING TO BE OPTIMA
BOLD, UPPER & LOWER CASE,
TITLE TO BE 1" HT., ALL OTHER
TEXT TO BE 3/16" HT.
HANDLE
4" SQUARE HOLD FOR
ANCHOR BOLT
VA/COR TO REVIEW
LOCATIONS PRIOR TO
ANCHORING
OPENING
POWDER
COATED STEEL
RECEPTACLE SPECIAL HINGE LID WITH
FLORAL REGULATIONS
DECAL ATTACHED
(SEE LID PLAN VIEW)
HANDLE
POWDER COATED
STEEL RECEPTACLE;
COLOR AND FINISH
SHALL BE APPROVED
IN THE SUBMITTAL
PROCESS AND IN
ACCORDANCE WITH
THE VA SIGNAGE
DESIGN GUIDE
MANUAL.
TRASH RECEPTACLE
PERSPECTIVE
FLOWER VASE RECEPTACLE
PERSPECTIVE
BOTTOM VIEW
LID PLAN VIEW
FLORAL
REGULATIONS
1. Fresh cut flowers may be placed on graves at any time of the year. Plastic floral cones are available for use within the cemetery and are located in the receptacle below.
2. Floral items will be removed from graves as soon as they become faded and unsightly or to facilitate mowing.
3. Artificial flowers and potted plants may be placed on graves November 1 through April 15 only.
4. Potted plants may be placed on graves 10 days before to 10 days after Easter Sunday and Memorial Day only.
5. Seasonal holiday adornments such as Christmas wreaths, potted poinsettias and other seasonal adornments may be placed on graves from Dec. 1 through Jan. 20. Grave blankets may not be larger than two feet by three feet.
6. Floral items and decorations may be removed for grounds maintenance.
7. Permanent plantings, statues, vigil lights, breakable objects of any nature, and similar commemorative items are not permitted on graves at any time.
8. Floral items and other types of decorations will not be secured to headstones or markers.
7- 1/
2"
4 FLOWER VASE RECEPTACLE PER
SPECIFICATIONS
1 TRASH RECEPTACLE PER SPECIFICATIONS
5 GRAVEL SPLASH AREA
SEE PLAN DETAIL THIS SHEET
6 DO NOT DRINK SIGN, 4 PER HYDRANT
120 DEGREES APART
7 TRASH DECAL
PER SPECIFICATIONS
8 FLOWER VASES DECAL
PER SPECIFICATIONS
1' -0
Flower Vases Trash
CL
CL
9 7-1/2" SQ. PRECAST CONCRETE POST.
ALL PLUMBING TO BE CAST INTO
PRECAST POST FOR CONNECTION
AFTER INSTALLATION.
2' -4
5"
4"
ELEVATION
(ABOVE GROUND)
10 FOOTING PER MANUFACTURER;
COORDINATE WITH IRRIGATION. SEE
ELEVATION (BELOW GROUND) DETAIL, THIS
SHEET.
ANCHOR TO CONCRETE PER MANUFACTURERS
RECOMMENDATIONS; VA/COR TO REVIEW
LOCATIONS PRIOR TO ANCHORING
WATER FAUCET ASSEMBLY PER
SPECIFICATIONS; COORDINATE WITH
IRRIGATION
Flower Vases
2"
2" 90° ELBOW
2" X 3/4" REDUCER
3/4" COPPER TYPE K
DOMESTIC PIPING FROM
PVC SUPPLY TO CURB
STOP VALVE/ PRESSURE
REDUCING REGULATOR
CURB STOP VALVE
BRASS PRESSURE
REDUCING REGULATOR
1/2" COPPER TYPE K DOMESTIC PIPING
FROM CURB STOP VALVE/PRESSURE
REDUCING REGULATOR TO SPIGOT
ASSEMBLY
BRICK
PVC PIPE RISER
8" WASHED ROUND GRAVEL
8" WASHED ROUND GRAVEL
12" X 22" CONCRETE
VALVE BOX WITH METAL LID
1'-6"
3/8" WASHED ROUND
GRAVEL (12" MIN. DEPTH),
COMPACTED
FILTER FABRIC,
12" MINIMUM DEPTH
1/2" COPPER TUBING CAST
INTO CONCRETE SIGN POST
FOR CONNECTIONS AFTER
INSTALLATION
CONCRETE FOOTING
COMPACTED SUBGRADE
3' -0
2' -4
ELEVATION
(BELOW GROUND)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge d et ai ls .d w bn or av ed :6
/1 8/
0:
lo t:6
/2 2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
Office of
Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK505
135BNJF
SIGNAGE & FURNISHINGS
DETAILS 5
SCALE:1
FLOWER WATERING STATION
1"=1'
SCALE:3
SIGN PLACEMENT
1"=5'
BACK OF CURB (BOC)
SECTION MARKER
TRAFFIC REGULATORY SIGN
STREET SIGN
BACK OF CURB (BOC)
DIRECTIONAL SIGNS
BACK OF CURB (BOC)
2'-0"
2' -0
2' -0
10'-0", TYP.
PLACEMENT:
1. SIGHT TRIANGLES AT INTERSECTIONS
AND DRIVEWAYS FOR SAFETY
REASONS, SIGNS MUST NOT BE
PLACED IN THE SIGHT TRIANGLE
(SHADED AREA) WHERE THEY CAN
OBSCURE A DRIVER'S VISION.
2. ENSURE THE LOCATION OF A SIGN
DOES NOT BLOCK A DRIVER'S VISION
OF PEDESTRIANS. NO SIGNS IN THE
SIGHT TRIANGLE APPLIES TO
ROADWAY INTERSECTIONS AS WELL
AS DRIVEWAYS.
3. TRAFFIC REGULATORY SIGNS SUCH AS
STOP, YIELD, STREET, AND
PEDESTRIAN CROSSING ARE AN
EXCEPTION TO THIS RULE.
4. SIGNS MUST BE LOCATED A MINIMUM
OF 25 LINEAR FEET APART FROM ONE
ANOTHER TO ENSURE LEGIBILITY.
5. WHEN INSTALLING SIGNS, ADJUST
LOCATIONS FOR UTILITIES, IRRIGATION
LINES AND STREET TREES.
SCALE:2
'DO NOT DRINK' MARKER SIGN
1"=2"
Do Not
Drink
SECURE W/ (2)
16" X 2" S.S.
TAMPER-PROOF
SCREWS & EXPANSION
SHIELDS
8" THICK ALUMINUM
SIGN PANEL; COORDINATE
WITH HYDRANT MANUFACTURER
FOR ATTACHMENT TO POST
1' -3
4"
4"
SCALE:4
POST & PANEL THREE LINES OF TEXT DETAIL (NC-04.03-c2)
1"=5'
All Funerals Public Information Center
3'-0"
1' -6
2" 3 3/4"
1 11/16"
1 11/16" 3 3/4"
1 11/16"
3 3/4" 1 11/16"
3 3/4"
Text As Shown On Details
3' -6
3'-0"
℄2'-0" TO BACK OF
CURB OR WALK, TYP.
FINISHED GRADE
PRECAST CONCRETE COLLAR
SEE 4/LK507
1' -6
2"
51 2"
2" 1"
2' -6
R
EC
ES
S
AR
EA
ALUMINUM SIGN PANEL
SEE 6/LK504
2 1/2" HT. LETTERING, OPTIMA BOLD
NARROW TYPE FACE (FOR TEXT WITH
FIT ISSUES UTILIZE OPTIMA BOLD
NARROW), INITIAL CAP AND LOWER
CASE
PRECAST CONCRETE POST;
RECESS = 2 1/4" X 2'-6" X 3/8"
DP. (3) SIDES; NO RECESS ON
INSIDE OF POSTS; SEE 1/LK504
LAYOUT 'A'
TYPE FACE TO BE OPTIMA BOLD NARROW
VALVE BOX (LOCATION PER PLAN)
COORDINATE WITH IRRIGATION
SPLASH AREA AGGREGATE TO MATCH
EXISTING FLOWER WATERING STATIONS
FLOWER VASE RECEPTACLE
TRASH RECEPTACLE:
TAPERED DOME LID W/
SELF-CLOSING DOOR
2% MAX
SLOPE EITHER
DIRECTION
5" THICK REINFORCED CONC. PAD W/ 14" RADIUS
@ EDGE, TYP. MEDIUM BROOM FINISH
RUB OUT ALL SURFACE TOOL MARKS
SCALE:1A
FLORAL REGULATIONS
1"=3"
FLORAL REGULATIONS
SEE DETAIL 1A/LK505
HANDLE
FLORAL REGULATIONS NOTE: SUBMIT
SHOP DRAWINGS. FINAL VERBAGE TO BE
REVIEWED AND APPROVED BY VA/COR
NOTE: COORDINATE WITH
IRRIGATION AND ALL UTILITIES
'-0
'-0
50'-0"
NOTE: FINAL SIGN
PLACEMENT TO BE STAKED
AND APPROVED BY VA/COR
PRIOR TO INSTALLATION.
POST SETTING/FOOTING
DETAIL: SEE 5/LK504
COLOR AND FINISH SHALL
BE APPROVED IN THE
SUBMITTAL PROCESS AND
IN ACCORDANCE WITH THE
VA SIGNAGE DESIGN
GUIDE MANUAL.
COLOR AND FINISH SHALL BE
APPROVED IN THE SUBMITTAL
PROCESS AND IN ACCORDANCE
WITH THE VA SIGNAGE DESIGN
GUIDE MANUAL.
No Tome
El Agua
4"
4"
4"
EQ.
EQ.
EQ. EQ. EQ. EQ.
CL
CL
CL
CL
CL
CL CL CL CL
EQ.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
F
O
A
Fi le
P at h:
y
:\1
\1 v a nc a m id w es t -g ra ve si te e xp an si on le av en w or th k an sa s\ _0 ci vi l\_ c ad fi le s\
_0 sh ee ts \1
_c _s ig na ge d et ai ls .d w bn or av ed :6
/1 8/
0:
lo t:6
/2 2/
:0
PM
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18704 JUNE 22, 2026
Date:
LEAVENWORTH NATIONAL CEMETERY
GRAVESITE EXPANSION
897CM3025
150 MUNCIE ROAD; LEAVENWORTH, KANSAS 66048
BID DOCUMENTS
Office of
Design and Construction
Services
BID SUBMITTAL
OF ---
IRRIGATION:
EC DESIGN
400 5th St West Des Moines, IA 50265
(515) 225-6265
COST ESTIMATING:GEOTECHNICAL:
TERRACON
15620 W 113th St Lenexa, KS 66219
(913) 202-7598
OCMI
2100 North Greenville Ave. #1150 Richardson, TX 75082
(469) 431-0571
TECHNOLOGY:
IMEG
900 E. Prima Ctr Pkwy #320 Scottsdale, AZ 85258
(480) 222-3789 LK506
136BNJF
SIGNAGE & FURNISHINGS
DETAILS 6
SERVICE SEALS NOTES
1. REMOVE & REPLACE EXISTING (5) SEALS AS FOLLOWS: ARMY, MARINE CORPS, NAVY,
AIR FORCE, AND COAST GUARD SEALS. SALVAGE EXISTING SEALS TO BE HANDED OVER
TO THE NCA.
2. REMOVE EXISTING GRANITE WALL, BASE, AND ASSOCIATED FOUNDATION ELEMENTS AS
REQUIRED FOR CONSTRUCTION OF NEW WALL. CONTRACTOR IS TO PERFORM ALL
DEMOLITION NECESSARY TO COMPLETE THE WORK. EXISTING UNDERGROUND WALL
FOUNDATION CONDITIONS ARE UNKNOWN. UPON EXPOSURE, CONTRACTOR IS TO
COORDINATE WITH COR TO DETERMINE ABANDONMENT OR REUSE OF EXISTING
FOUNDATION ELEMENTS.
3. FINAL PLACEMENT AND ALIGNMENT OF PROPOSED WALL IS TO BE COORDINATED WITH
THE COR BASED ON FIELD CONDITIONS AND DETERMINATION OF EXISTING
FOUNDATION CONDITIONS.
3. PROVIDE NEW GRANITE WALL FOR NEW SEALS. NEW GRANITE WALL IS TO MATCH
EXISTING WALL IN SIZE, SHAPE, APPEARANCE, COLOR, AND TEXTURE.
4. INSTALL THE (6) NEW SEALS IN NEW LOCATION AS SHOWN ON THE DETAIL.
5. ORDER OF SEALS (LEFT TO RIGHT): ARMY, MARINE CORPS, NAVY, AIR FORCE, SPACE
FORCE, COAST GUARD.
EXISTING ARMY
SERVICE SEAL TO
BE REMOVED
LOCATION OF NEW MARINE
CORPS SERVICE SEAL
MOCKUP AND PATCHING
REVIEW PRIOR TO
ACCEPTANCE AND
CONTINUATION OF WORK
LOCATION OF NEW
NAVY SERVICE SEAL
TO BE INSTALLED
EXISTING COAST
GUARD SERVICE SEAL
TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .