A0002_Att_20_(New)_40-D-7017_0002.PDF

PDF 250 KB Posted

Attached to
Hyrum Dam Spillway Replacement Federal contract opportunity
Solicitation number
140R4024R0020
Issued by
Department of the Interior Bureau of Reclamation

About this file

This document appears to be a set of standard technical drawings and details for the installation of chain link fencing. It provides specifications and installation requirements for concrete-mounted fence posts, fencing fabric, gates, and other typical fence components. The drawings illustrate various post mounting details, fence elevation and plan views, and considerations for installing fencing on steep slopes. While this document does not appear to be directly related to a specific federal contract opportunity, it likely contains relevant technical information that could be referenced in a solicitation for chain link fencing installation or replacement projects.

View the file

Other files for this federal contract opportunity

Other files attached to Hyrum Dam Spillway Replacement, newest first.
File Type Posted
A0003_Att_6_Updated_Solicitation_Pages_12-14_0003.pdf PDF
A0003_Att_7_Updated_Continuation_of_Section_B_in_Excel_Format_0003.xlsx XLSX spreadsheet
Sol_140R4024R0020_Amd_0003.pdf PDF
A0003_Att_1_Informational_Page_0003.pdf PDF
A0003_Att_2_140R4024R0020_Additional_Technical_Questions_and_Answers_0003.pdf PDF
A0003_Att_3_(Revised)_188-D-60267_0003.pdf PDF
A0003_Att_4_(Revised)_03_30_00___Cast-In-Place_Concrete_0003.pdf PDF
A0003_Att_5_(Revised)_33_46_36___Drain_Pipes_0003.pdf PDF
A0002_Att_12_(New)_188-D-60215_Existing_Spillway-Dike_Plan_0002.pdf PDF
A0002_Att_2_140R4024R0020_Contracting_Questions_and_Answers_0002.pdf PDF
A0002_Att_3_Updated_Solicitation_Pages_62-67_0002.pdf PDF
A0002_Att_5_(New)_01_14_20_-_Reservoir_Spillway_and_Outlet_Works_Operations_0002.pdf PDF
A0002_Att_9_(New)_35_21_20_-_Stoplog_Guides_0002.pdf PDF
A0002_Att_10_(New)_51_00_20_-_Reservoir_Water_Surface_Elevation_Data_0002.pdf PDF
A0002_Att_13_(Revised)_188-D-60379_Gate_Hoist_Enclosure_Panel_Schedules_0002.pdf PDF
A0002_Att_15_(New)_40-D-4335_0002.pdf PDF
A0002_Att_17_(New)_40-D-6551_0002.pdf PDF
A0002_Att_1_Informational_Page_0002.pdf PDF
A0002_Att_4_140R4024R0020_Technical_Questions_and_Answers_0002.pdf PDF
A0002_Att_6_(New)_01_46_20_-_Testing_Agency_Services_0002.pdf PDF
A0002_Att_7_(Revised)_02_41_07_-_Removal_and_Disposal_of_Existing_Features_0002.pdf PDF
A0002_Att_11_(Revised)_51_02_82_-_Hazardous_Materials_Survey_and_Analytical_Results_0002.pdf PDF
Sol_140R4024R0020_Amd_0002.pdf PDF
A0002_Att_19_(New)_40-D-6592_0002.PDF PDF
A0002_Att_23_Evaluations_of_Potential_Filter_Sand_and_Drain_Gravel_Sources_for_Hyrum_Dam_Modifications_0002.pdf PDF
A0002_Att_18_(New)_40-D-6552_0002.pdf PDF
A0002_Att_21_(New)_40-D-60001_0002.pdf PDF
A0002_Att_8_(Replacement)_31_03_33_-_Removal_and_Control_of_Water_0002.pdf PDF
A0002_Att_14_(New)_40-D-4334_0002.pdf PDF
A0002_Att_22_(New)_40-D-60002_0002.pdf PDF
A0002_Att_16_(New)_40-D-6477_0002.pdf PDF
A0002_Att_25_Hyrum_Spillway_Replacement_Geological_Investigations_2022_0002.pdf PDF
A0002_Att_24_Geologic_Investigations_of_Hyrum_Dam_Spillway_2016-2019_0002.pdf PDF
Sol_140R4024R0020_Amd_0001.pdf PDF
A0001_Att_1_Informational_Page_0001.pdf PDF
A0001_Att_2_Site_Visit_Sign-in_Sheet_0001.pdf PDF
Sol_140R4024R0020.pdf PDF
Attachment_7_SF24_Bid_Bond_Form.pdf PDF
Solicitation_No__140R4024R0020_Hyrum_Dam_Spillway_Replacement.pdf PDF
Attachment_3_Current_Spillway_Drawings_(Info_Only).pdf PDF
Attachment_2_140R4024R0020_Drawings_90_.pdf PDF
Attachment_4_Continuation_of_Section_B_in_Excel_Format.xlsx XLSX spreadsheet
Attachment_5_Construction_Wage_Rate_Requirements_for_Cache_County__UT.pdf PDF
Attachment_6_Subcontracting_Plan_Template.docx DOCX document
Attachment_1_140R4024R0020_Specifications_90_.pdf PDF
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Top of concrete

Grout

Edge of concrete

2"

Varies, 6" min

Edge of concrete Bar 3/8x3/8x0'-9"

Chain link fabric on outside of fenced area

Chain link fabric on inside of fenced area for this installation only.

2"

CL. 3/8" Pl.

and fence post

8"

Varies, 4" min.

Post dia.

+2-inches min.

CL. Fence post

Edge of concrete

Chain link fabric on outside of fenced area

Top of concrete

9"

6"1 1/2"

9"6"

1/ 2"

CL. 13/16"Ø Holes in plate for 5/8"Ø expansion anchors

2 1/2" Min., Typical of sloped surface

1/

2"

2"

1' -2

M in

Chain link fabric

3/8" Pl.

Chain link fabric

Chain link fabric

3/8" Pl.

CL. Fence post and mounting plate

5" 1 1/2"

4"

5"

1/ 2"

4"

8"

DETAIL - SURFACE MOUNTED POST

DETAIL - EMBEDDED POST

(For slabs 1'-2" thick or greater or wall surfaces)

DETAIL - SIDE MOUNTED POST

4 1/2"

CL. 13/16"Ø Holes in plate for 5/8"Ø adhesive anchors

3/8" Pl.

Top railTop rail

End post

Top of concrete

For fabric height less than 7-feet

Barbed wire continuous at 45° across walk gate for fabric height equal to or greater than 7-feet, see Detail 1

Brace all panels containing gate, corner, pull or end posts

Truss rod with tightener

Barbed wire

Gate post

Tension wire Corner panel

Corner post

Top rail

End Post

Corner Post

Single Barbed wire gate

Top rail

Truss rod with tightener

Pull post

Barbed wire Top rail

Brace rail, see Note 9

Truss rod with tightener

Brace rail, see Note 9 Brace corner post both ways, see Note 9

Gate Leaf Width

Single gate

TYPICAL ELEVATION

VIEW A-A

AA

DETAIL 1

PANELS ADJOINING PULL POST

Ties

Tension band

Post cap

Top rail

Chain link fabric

Tension wire Top of concrete

Tension bar

Tension band

Rail end cup and brace band

Ties

Top rail sleeve

Top of concrete

O U

TS

ID

E

Barbed wire

End brace band

For mounting, see Detail 1, 2, or 3 as specified

H ei gh t of c ha in li nk f ab ri c

2"

N om in al f en ce h ei gh t

Outrigger/Barbed Wire Arm

Brace rail, see Note 9

Brace band

Truss rod with tightener

LINE POST END POST, CORNER POST,

OR GATE POST

Gate post Corner post

Line post

0" M ax

Po st s pa ci ng

Single gate

10'-0" Max.

Post spacing

Dimension face to face of posts

10'-0" Max.

Post spacing

TYPICAL FENCING PLAN

Li nk s ru n pe rp en di cu la r to s lo pe

Provide terminal posts at slope changes

Bias cut parallel to posts and back weave around tension bar according to standard practice.

For mounting, see Detail 1, 2, or 3 as specified

FENCE INSTALLATION ON STEEP SLOPES

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -7

7-

R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-0 4-

LA

S T

S A V

ED

B Y

R R O

D R

IG

U

EZ

S

TA

N D

A R D

D R A W

IN

G

S

S

TA

N D

A R D

A N

D T

YP

IC

A L

D

ES

IG

N

S

C H

A

IN

L

IN

K F

EN

C

IN

G

CHAIN LINK FENCING

REQUIREMENTS

CONCRETE

INSTALLATION

PLAN, ELEVATIONS, AND

DETAILS

DENVER, CO

40-D-7017

1999-04-30

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

G.E. SHERARD

D.L. BORING

T.C. GRABER

NOTES

1. See specific site plan for overall fence dimensions and size, location and swing of gates.

2. Install pull posts at the end of each run, at maximum intervals of 500 feet, and at vertical and horizontal changes in alignment greater than 30 degrees.

3. Weld all joints between tubular gate frame members or use heavy fittings to provide rigid and watertight connections.

4. Gate dimensions are face to face of gate posts.

5. Provide latches, stops and keepers for all gates as specified.

6. End post, corner posts, pull posts, and gate posts are designated as terminal posts.

7. Chain link fabric shall be attached to fence framework in accordance with the Chain Link Fence Manufacturer's Institute (CLFMI) Product Manual.

8. Chain link fences are 6 foot high fabric unless otherwise noted on specific site plans.

9. Brace rails and truss rods are not required for fabric height of 6 feet or less.

R

EV

N O

1.

-0 4-

D

Ry an

, T yl er J

P .E

U

PD

A

TE

D D

R A W

IN

G

T

EX

T S

TY

LE

B O

R D

ER

A

N D

TI

TL

E B

LO

C K T

O C

U R R

EN

T D

R A W

IN

G

R

EC

O R D

S S

YS

TE

M

N

U M

B

ER

ED

N

O

TE

S A

N D

M A D

E M

IN

O

R R

EV

IS

IO

N

S

T.C. GRABER

M.R. O'SHEA

Structural and Architectural Group

R el ea se d

Sheets and Views
22 x 34

File details come from the government source that posted it. Updated .