This document appears to be a set of standard technical drawings and details for the installation of chain link fencing. It provides specifications and installation requirements for concrete-mounted fence posts, fencing fabric, gates, and other typical fence components. The drawings illustrate various post mounting details, fence elevation and plan views, and considerations for installing fencing on steep slopes. While this document does not appear to be directly related to a specific federal contract opportunity, it likely contains relevant technical information that could be referenced in a solicitation for chain link fencing installation or replacement projects.
View the file
Other files for this federal contract opportunity
Show all 45
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Top of concrete
Grout
Edge of concrete
2"
Varies, 6" min
Edge of concrete Bar 3/8x3/8x0'-9"
Chain link fabric on outside of fenced area
Chain link fabric on inside of fenced area for this installation only.
2"
CL. 3/8" Pl.
and fence post
8"
Varies, 4" min.
Post dia.
+2-inches min.
CL. Fence post
Edge of concrete
Chain link fabric on outside of fenced area
Top of concrete
9"
6"1 1/2"
9"6"
1/ 2"
CL. 13/16"Ø Holes in plate for 5/8"Ø expansion anchors
2 1/2" Min., Typical of sloped surface
1/
2"
2"
1' -2
M in
Chain link fabric
3/8" Pl.
Chain link fabric
Chain link fabric
3/8" Pl.
CL. Fence post and mounting plate
5" 1 1/2"
4"
5"
1/ 2"
4"
8"
DETAIL - SURFACE MOUNTED POST
DETAIL - EMBEDDED POST
(For slabs 1'-2" thick or greater or wall surfaces)
DETAIL - SIDE MOUNTED POST
4 1/2"
CL. 13/16"Ø Holes in plate for 5/8"Ø adhesive anchors
3/8" Pl.
Top railTop rail
End post
Top of concrete
For fabric height less than 7-feet
Barbed wire continuous at 45° across walk gate for fabric height equal to or greater than 7-feet, see Detail 1
Brace all panels containing gate, corner, pull or end posts
Truss rod with tightener
Barbed wire
Gate post
Tension wire Corner panel
Corner post
Top rail
End Post
Corner Post
Single Barbed wire gate
Top rail
Truss rod with tightener
Pull post
Barbed wire Top rail
Brace rail, see Note 9
Truss rod with tightener
Brace rail, see Note 9 Brace corner post both ways, see Note 9
Gate Leaf Width
Single gate
TYPICAL ELEVATION
VIEW A-A
AA
DETAIL 1
PANELS ADJOINING PULL POST
Ties
Tension band
Post cap
Top rail
Chain link fabric
Tension wire Top of concrete
Tension bar
Tension band
Rail end cup and brace band
Ties
Top rail sleeve
Top of concrete
O U
TS
ID
E
Barbed wire
End brace band
For mounting, see Detail 1, 2, or 3 as specified
H ei gh t of c ha in li nk f ab ri c
2"
N om in al f en ce h ei gh t
Outrigger/Barbed Wire Arm
Brace rail, see Note 9
Brace band
Truss rod with tightener
LINE POST END POST, CORNER POST,
OR GATE POST
Gate post Corner post
Line post
0" M ax
Po st s pa ci ng
Single gate
10'-0" Max.
Post spacing
Dimension face to face of posts
10'-0" Max.
Post spacing
TYPICAL FENCING PLAN
Li nk s ru n pe rp en di cu la r to s lo pe
Provide terminal posts at slope changes
Bias cut parallel to posts and back weave around tension bar according to standard practice.
For mounting, see Detail 1, 2, or 3 as specified
FENCE INSTALLATION ON STEEP SLOPES
A
LW
A
YS
T H
IN
K
S A
FE
TY
SHEET
D
C
B
A
D
C
B
A
B U
R
EA
U O
F R
EC
LA
M
A
TI
O N
U .S
D
EP
A R
TM
EN
T
O F
TH
E
IN
TE
R
IO
R
C A D
S
YS
TE
M
A ut oC A D
4.
0S
LM
S T
EC
H
C A D
F
IL
EN
A M
E
-D -7
7-
R D
-1 .D
W G
LA
S T
S A V
ED
D A
TE
-0 4-
LA
S T
S A V
ED
B Y
R R O
D R
IG
U
EZ
S
TA
N D
A R D
D R A W
IN
G
S
S
TA
N D
A R D
A N
D T
YP
IC
A L
D
ES
IG
N
S
C H
A
IN
L
IN
K F
EN
C
IN
G
CHAIN LINK FENCING
REQUIREMENTS
CONCRETE
INSTALLATION
PLAN, ELEVATIONS, AND
DETAILS
DENVER, CO
40-D-7017
1999-04-30
DESIGNED
DRAWN
CHECKED
TECH. APPR.
APPROVED
PEER REVIEWER -
G.E. SHERARD
D.L. BORING
T.C. GRABER
NOTES
1. See specific site plan for overall fence dimensions and size, location and swing of gates.
2. Install pull posts at the end of each run, at maximum intervals of 500 feet, and at vertical and horizontal changes in alignment greater than 30 degrees.
3. Weld all joints between tubular gate frame members or use heavy fittings to provide rigid and watertight connections.
4. Gate dimensions are face to face of gate posts.
5. Provide latches, stops and keepers for all gates as specified.
6. End post, corner posts, pull posts, and gate posts are designated as terminal posts.
7. Chain link fabric shall be attached to fence framework in accordance with the Chain Link Fence Manufacturer's Institute (CLFMI) Product Manual.
8. Chain link fences are 6 foot high fabric unless otherwise noted on specific site plans.
9. Brace rails and truss rods are not required for fabric height of 6 feet or less.
R
EV
N O
1.
-0 4-
D
Ry an
, T yl er J
P .E
U
PD
A
TE
D D
R A W
IN
G
T
EX
T S
TY
LE
B O
R D
ER
A
N D
TI
TL
E B
LO
C K T
O C
U R R
EN
T D
R A W
IN
G
R
EC
O R D
S S
YS
TE
M
N
U M
B
ER
ED
N
O
TE
S A
N D
M A D
E M
IN
O
R R
EV
IS
IO
N
S
T.C. GRABER
M.R. O'SHEA
Structural and Architectural Group
R el ea se d
| Sheets and Views |
| 22 x 34 |
File details come from the government source that posted it. Updated .