This document appears to be a technical drawing and specifications for guard posts and related components for a federal contract opportunity. The drawing provides details on the construction of steel pipe sleeves, concrete bases, and reinforcement for guard posts in a non-security application. It includes specific dimensions, materials (steel pipe, HDPE pipe, concrete), and fabrication requirements. The drawing references a related federal contract opportunity for the Hyrum Dam Spillway Replacement project, which involves the construction of a new spillway and removal of the existing spillway, associated mechanical and electrical features, roadway realignment, and other civil works. The project is being procured by the Department of the Interior Bureau of Reclamation, with an anticipated performance period from March 2025 through January 2029.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4' -6
8" Std. steel pipe sleeve
6" Std. steel pipe (5'-3" long)
6" Std. pipe cap
CL. 3/8"x4" Headed concrete anchor (8 req'd per pipe sleeve spaced @ 90°)
Rockfill
18"Ø Single wall perforated HDPE pipe 2'
-0
(M in
(M in
6" 3"
TOC
Upper bar 11Øx3/8 with 6 3/4"Ø hole in center
Lower bar 11Øx3/8 with 7"Ø hole in center
Foundation, see Note 1
4' -6
3"
4' -0
1"
Drill 7/8"Ø holes through pipe to receive 2-#6 rebar that are 1'-2" in length. Locate rebar 90° from each other and tack weld rebar to pipe.
Crown top of fill concrete for runoff
1' -0
Surfacing material (if applicable)
6" Std. steel pipe filled with concrete
18"Ø Concrete base
Finished grade Crown base for runoff
Foundation reinforcement not shown, see Note 1
TOC
4' -6
3"
2' -3
(M ax
1"
1' -0
3"
M in
S ee
N ot e
Crown top of fill concrete for runoff
6" Std. steel pipe filled with concrete
Surfacing material (if applicable)
Finished grade Crown base for runoff
TOC
Drill 7/8"Ø holes through pipe to receive 2-#6 rebar that are 1'-2" in length.
Locate rebar 90° from each other and tack weld rebar to pipe.
18"Ø Concrete base
DO NOT GALVANIZE STEEL PIPE
FOR FOUNDATION EMBEDDED IN COMMON SOIL CONDITION
GALVANIZE PIPE SLEEVE
DO NOT GALVANIZE STEEL PIPE
REMOVABLE GUARD POST AND SLEEVE FOR SLAB-ON-GRADE CONDITION
DO NOT GALVANIZE STEEL PIPE
FOR FOUNDATION EMBEDDED IN ROCK CONDITION
A
LW
A
YS
T H
IN
K
S A
FE
TY
SHEET
D
C
B
A
D
C
B
A
B U
R
EA
U O
F R
EC
LA
M
A
TI
O N
U .S
D
EP
A R
TM
EN
T
O F
TH
E
IN
TE
R
IO
R
C A D
S
YS
TE
M
A ut oC A D
4.
0S
LM
S T
EC
H
C A D
F
IL
EN
A M
E
-D -6
-R D
-1 .D
W G
LA
S T
S A V
ED
D A
TE
-0 4-
LA
S T
S A V
ED
B Y
R R O
D R
IG
U
EZ
S
TA
N D
A R D
D R A W
IN
G
S
S
TA
N D
A R D
A N
D T
YP
IC
A L
D
ES
IG
N
S
M
IS
C
EL
LA
N
EO
U
S M
ET
A
LW
O R K
TYPICAL GUARD POSTS
NON-SECURITY
APPLICATION
DENVER, CO
40-D-60002
2015-03-23
DESIGNED
DRAWN
CHECKED
TECH. APPR.
APPROVED
ADMIN APPROVAL -
Bernard Lajimodiere
RBarthel
Olaff G. Huerta
Barthel, Rodney J P.E.
Plant Structures Group
Bernstein, Alfred I P.E.
Plant Structures Group
ASTM denotes American Society for Testing and Materials
AWS denotes American Welding Society
AWWA denotes American Water Works Association
COR denotes Contracting Officer's Representative
HDPE denotes high density polyethylene
Max. denotes maximum
Min. denotes minimum psi denotes pounds per square inch
Rebar denotes concrete reinforcement
Std. denotes standard
TOC denotes top of concrete
Typ. denotes typical
All welds, sections and details are typical for all similar conditions.
Coat steel guard post and upper bar per specifications or as directed by COR.
Unless noted otherwise, galvanize pipe sleeve and lower bar after fabrication per ASTM A385.
Fabricated Metalwork:
Bars _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ASTM A36 Std. Steel Pipe _ _ _ _ _ _ _ _ _ _ _ _ _ ASTM A53, Grade B Rebar _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ASTM A615
HDPE Pressure Pipe: ASTM F405.
Unless noted otherwise, make all welds continuous and in the shop.
Unless noted otherwise, fabricator shall determine edge preparation and root opening for groove welds.
Arc-Welding Electrodes: Filler metal and required shielding gases or fluxes shall be per AWS D1.1 with filler metal for steel having a minimum tensile strength of 70,000 psi.
Rockfill per ASTM C33, Coarse Aggregate, Size No. 57.
Unless noted otherwise, concrete structural design is based on concrete with a minimum compressive strength of 2,500 psi at 28 days and reinforcement with a minimum yield strength of 60,000 psi.
NOTES
1. Foundation design engineer shall verify foundation stability and the concrete and reinforcement strength requirements.
2. 12" Embedment in moderately weathered or less weathered rock and 24" embedment in intensely-to-moderately weathered or more weathered rock. Rock weathering classifications are defined within drawing 40-D-7022.
3. Install guard posts at locations shown on specifications drawings and/or as directed by COR.
GENERAL NOTES
R
EV
N O
R
EV
N O
-0 4-
D
U
PD
A
TE
D D
R A W
IN
G
T
EX
T S
TY
LE
T
O C
U R R
EN
T D
R A W
IN
G
R
EC
O R D
S S
YS
TE
M
M
IN
O R R
EV
IS
IO
N
S
-0 4-
D
M
IN
O R M
O D
IF
IC
A
TI
O N
S
Re le as ed
File details come from the government source that posted it. Updated .