MCON P856, Manchester Tank Farm Improvements, Manchester Fuel Depot, Fleet Logistics Center Puget Sound (FLCPS), Manchester, Washington

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
N44255-21-R-2000
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Port Orchard WA 98366, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation seeks design and construction services for the MCON P856 Manchester Tank Farm Improvements project at the Manchester Fuel Depot in Manchester, Washington. The Naval Facilities Engineering Command, on behalf of the Department of the Navy, seeks to award a firm fixed-price contract to construct new aboveground storage tanks, secondary containment systems, and perimeter roadways. Offerors must demonstrate experience designing and constructing fuel storage tanks over 50,000 barrels, secondary containment structures, tank demolition over 35,000 barrels, and cathodic protection or automatic tank gauging systems. Proposals will be evaluated on technical experience, past performance, and price, with award made to the lowest priced technically acceptable offer. The response deadline is January 28, 2021.

The solicitation utilizes no set-aside designations. The primary NAICS code is 237990 and PSC code S206. The work includes building new multi-product tanks with 100,000 barrel total capacity within secondary containment per UFC 3-460-01 by January 2024. Portions of work will be conducted in potentially contaminated areas at the Manchester Fuel Depot in Port Orchard, Washington. The contract value is not disclosed but is estimated in excess of $25 million based on project details and facility upgrades required.

Notice text

The contract requirements include all design, repair, labor, material, equipment, supervision and associated costs to construct new Aboveground Storage Tanks (AST), which will provide AST’s within a secondary containment system designed in accordance with the Unified Facilities Criteria (UFC) 3-460-01 and the current Standard Tank Design AW 78-24-27. The tanks will be multi-product, 100 percent internally coated, with a fixed cone roof; they will be connected to both the JP-5 and F-76 piping systems, and sited to avoid mapped seismic fault lines. Portions of the associated secondary containment and perimeter roadways will be located within potentially contaminated sites.

Files

File Type Posted
Amendment 0013.pdf PDF
Amendment 0012.pdf PDF
Amendment 0012.pdf PDF
Amendment 0011.pdf PDF
PPI Responses 10.pdf PDF
Revised Wage Determination.pdf PDF
Amendment 0010.pdf PDF
Amendment 0009.pdf PDF
Amendment 0009.pdf PDF
PPI Responses 9.pdf PDF
Amendment 0008.pdf PDF
PPI Responses 7.pdf PDF
Site Visit Sign-in Sheet.pdf PDF
Amendment 0007.pdf PDF
PPI Responses 6.pdf PDF
Attachment Merchantable Timber Requirements.pdf PDF
Attachment Contractor Environmental and Safety Guide January 2020.pdf PDF
Amendment 0006.pdf PDF
Attachment MFD Contractor Dig Permit.pdf PDF
Attachment Chemical Analytical Data Report.pdf PDF
Picture 2 Pole 13 Photo.pdf PDF
Amendment 0005.pdf PDF
PPI Responses 5.pdf PDF
Picture 1 Junction Box Photo.pdf PDF
Amendment 0004.pdf PDF
PPI Responses 0004.pdf PDF
Attachment N SECNAV 5512 Form.pdf PDF
Attachment J Base Access Request Form 2.xls XLS spreadsheet
PPI Responses.pdf PDF
Site Visit Sign In Sheet.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Attachment 0001 SECNAV 5512 Form.pdf PDF
Attachment K Small Business Subcontracting Record.docx DOCX document
Attachment M COVID-19 Screening Questionnaire.pdf PDF
Attachment I EXAMPLE Overhead Forms.xlsx XLSX spreadsheet
Attachment L Small Business Participation and Commitment Strategy.docx DOCX document
Solicitation_N44255-21-R-2000.pdf PDF
Attachments A-B-C-D-E-F-G-H-I.docx DOCX document
Attachment H Construction Wage Determination.pdf PDF
Attachment J Base Access Request Form.xls XLS spreadsheet
Show all 42

Notice history

Similar open opportunities

Opportunity Agency Set-aside Responses due
DESC2103C - Bulk Fuel Storage Tanks Phase II, Yokota Air Base, Japan Yokota Air Base, Japan · NAICS 237120 ENDIST Japan No set-aside
Z1DA--NRM-CON-663A4-27-001 Under Dispenser Containment (UDC) and sump installation at VAMC American Lake Tacoma, Washington 98493, United States · NAICS 237120 Veterans Integrated Service Network 20 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity