Construction of Chilled Water Plant and Site Utility Upgrades at VA Medical Center in West Haven, CT
Closed Solicitation Posted
- Solicitation number
- W912WJ26RA008
- Agency
-
ENDIST New England
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- West Haven, Connecticut, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers, New England District seeks proposals on behalf of the Department of Veterans Affairs for the Chilled Water Plant Replacement and Site Utility Improvements (Phase A2) at the VA Connecticut Healthcare System, with Volume I due November 20, 2026. No set-aside is used, but the unrestricted best-value competition requires every offeror to include several brand-name components, each justified under other-than-full-and-open-competition approvals.
Work is performed at 950 Campbell Avenue, West Haven, Connecticut, on a medical center campus that remains operational throughout construction. Scope includes demolition of Building 16A, a new multi-story chilled water plant with chillers, cooling towers, and pumps, a new fuel tank farm, replacement of water mains from Campbell Avenue to Building 15, utility main loops, redundant electrical feeders, and new water storage tanks. The chilled water plant must meet USGBC LEED Silver, and the project must comply with DVA Physical Security Resiliency Design Requirements. Work hours are 6:00 AM to 4:00 PM, Monday through Friday. Major utility shutdowns are limited to Friday 7:00 PM through Sunday 7:00 PM, steam shutdowns to May 1 through September 30, and chilled water shutdowns to November 1 through April 1.
Required brand-name items are Assa Abloy Accentra Large Format lock cores, Johnson Controls electronic security systems, a Johnson Controls/Simplex fire alarm system, Siemens or Johnson Controls building automation, and SCADA programming by AMAZ Consulting, the incumbent SCADA programmer.
Evaluation uses four factors in descending importance: Past Performance, Management Approach, Small Business Participation Commitment Document, and Price, with non-price factors significantly more important than price. Award eligibility requires Past Performance at Satisfactory or Neutral Confidence and Management Approach and Small Business Participation at Acceptable. Offerors submit up to five projects completed within ten years; prime contractors need $40 million or more in construction cost, heavy utility scope, and at least three contributing disciplines. Fewer than two relevant projects yields Neutral Confidence and ineligibility. Small business participation must reach at least 10 percent of Total Acquisition Value (base plus all options), with goals for disadvantaged, woman-owned, HUBZone, service-disabled veteran-owned, and veteran-owned small businesses.
The firm-fixed-price contract is awarded to one responsible offeror, with base and option items evaluated together. The estimated price range is $75 million to $150 million. Option Item 0006 is a $1.4 million United Illuminating electrical service allowance, and options may be exercised up to Notice to Proceed. Performance runs 1,280 calendar days after Notice to Proceed. Bid guarantee is 20 percent of bid price or $3 million, whichever is less, and performance and payment bonds are 100 percent of contract price.
Amendment 0005 moves the design under revision for VA Standards Alert 003C2B-SA029, which is expected to reduce chillers, pumps, cooling towers, and fuel oil tank volume. Only Volume I is due November 20, 2026. USACE intends to issue a final design amendment in February 2027 with a new deadline for Volumes II and III, and all properly submitted Volume I packages will be invited to submit those volumes. Amendment 0006 adds Government property clauses (FAR 52.245-1 and 52.245-9; DFARS 252.245-7003 and 252.245-7005) and denies concurrent resubmission of a revised Volume I.
NAICS is 236220, and PSC is Y1NB, Construction of Heating and Cooling Plants.
Notice text
2 versions
Update #2 · Latest ·
The scope of the chilled water plant replacement consists of the demolition of the existing chilled water plant (building 16a) and construction of a new multi-story chilled water plant to include chillers, cooling towers, pumps, and all associated mechanical and electrical equipment. Due to the close proximity of the existing fuel tank farm adjacent to the existing chilled water plant, a new fuel tank farm will need to be constructed as part of the project, which primarily serves the central boiler plant, requiring close coordination with the medical center and ongoing related projects.The scope of the site utility upgrades consists of the replacement and upgrade of the existing fire protection water main and the domestic water main from Campbell Avenue to Building 15. Site utility upgrades also include providing utility main loops of chilled water supply and return, steam supply, condensate return, domestic water supply, and fire protection water supply which will originate from the new chilled water plant and back-feed to Building 1. The work also includes the installation of redundant electrical feeder from the utility demarcation point to Building 19 and coordination with the local electrical utility provider to provide further electrical redundancy offsite as well. In addition, new water storage tanks will be constructed. This project involves civil/site, mechanical, electrical, plumbing, structural, geotechnical, and architectural disciplines. The project must also comply with the DVAs Physical Security Resiliency Design Requirements (PSRDM). It is expected that the chilled water plant will be constructed to meet USGBC LEED Silver certification. The work is located adjacent to and within an active Medical Center campus which will be operational at all times. Impact to on-going operations must be kept to a minimum and carefully coordinated with the Contracting Officer and VAMC staff. In addition, the work area is constrained due to the active medical center operations which will limit laydown and storage areas during construction.
Update #1 ·
The scope of the chilled water plant replacement consists of the demolition of the existing chilled water plant (building 16a) and construction of a new multi-story chilled water plant to include chillers, cooling towers, pumps, and all associated mechanical and electrical equipment. Due to the close proximity of the existing fuel tank farm adjacent to the existing chilled water plant, a new fuel tank farm will need to be constructed as part of the project, which primarily serves the central boiler plant, requiring close coordination with the medical center and ongoing related projects.The scope of the site utility upgrades consists of the replacement and upgrade of the existing fire protection water main and the domestic water main from Campbell Avenue to Building 15. Site utility upgrades also include providing utility main loops of chilled water supply and return, steam supply, condensate return, domestic water supply, and fire protection water supply which will originate from the new chilled water plant and back-feed to Building 1. The work also includes the installation of redundant electrical feeder from the utility demarcation point to Building 19 and coordination with the local electrical utility provider to provide further electrical redundancy offsite as well. In addition, new water storage tanks will be constructed. This project involves civil/site, mechanical, electrical, plumbing, structural, geotechnical, and architectural disciplines. The project must also comply with the DVAs Physical Security Resiliency Design Requirements (PSRDM). It is expected that the chilled water plant will be constructed to meet USGBC LEED Silver certification. The work is located adjacent to and within an active Medical Center campus which will be operational at all times. Impact to on-going operations must be kept to a minimum and carefully coordinated with the Contracting Officer and VAMC staff. In addition, the work area is constrained due to the active medical center operations which will limit laydown and storage areas during construction.
Files
Show all 39
Notice history
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J041--Building 2 Steam Station Replacement | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z2DA | replace chiller 1 B104 | 580-24-111 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| J041--Condensate Pump Replacement | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| NTX VAMC Utility Tunnel Pump Room | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--598-22-115 Site Utility Infrastructure-NLR | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity