About this file

This file is a drawings document (Drawings.pdf) supporting the solicitation for construction of a chilled water plant and site utility upgrades at the VA Medical Center in West Haven, Connecticut (Solicitation Number W912WJ26RA008). The document contains technical drawings and plans related to the project scope, which includes demolition of the existing chilled water plant (Building 16a) and construction of a new multi-story facility with chillers, cooling towers, pumps, and associated mechanical and electrical equipment. The drawings also depict the new fuel tank farm construction, site utility upgrades including replacement of fire protection and domestic water mains from Campbell Avenue to Building 15, and utility main loops for chilled water supply/return, steam supply, condensate return, domestic water, and fire protection water originating from the new plant and extending to Building 1.

The drawings illustrate additional project components including redundant electrical feeders from the utility demarcation point to Building 19, new water storage tanks, and the coordination requirements necessary for work within an active medical center campus. The technical plans address civil/site, mechanical, electrical, plumbing, structural, geotechnical, and architectural disciplines. The project must comply with DVA Physical Security Resiliency Design Requirements (PSRDM) and achieve USGBC LEED Silver certification for the chilled water plant. The Contracting Officer is the Department of the Army Corps of Engineers Engineering District New England, and the work requires careful coordination to minimize impact on ongoing medical center operations.

View the file

Other files

File Type Posted
Amendment 0005.pdf PDF
Amendment 0005 - Submission Requirements and Evaluation Criteria (Clean).pdf PDF
Amendment 0005 - Submission Requirements and Evaluation Criteria (Track Changes).pdf PDF
Amendment 0004 - VA Hospital New Customer Load Report - 7_28_26.pdf PDF
Amendment 0004 - 12018711_Spec013000_Response.pdf PDF
Amendment 0004 - 12018255_01-ED101_01-EP101-Response.pdf PDF
Amendment 0004.pdf PDF
Amendment 0004 - 12018718_12018724_Spec013000_Response.pdf PDF
Amendment 0003 - Submission Requirements and Evaluation Criteria (Track Changes).pdf PDF
Amendment 0003.pdf PDF
Amendment 0003 - Plan T600.pdf PDF
Amendment 0003 - Submission Requirements and Evaluation Criteria (Clean).pdf PDF
Solicitation - W912WJ26RA008.pdf PDF
Amendment 0003 - JA 03 (JCI ESS_Redacted).pdf PDF
Amendment 0003 - Revisions to Specification Sections 270511-280500-281300-282300.pdf PDF
Amendment 0002 - Specs Section 01 22 00.pdf PDF
Amendment 0002 - Submission Requirements and Evaluation Criteria (Clean).pdf PDF
Amendment 0002 - Submission Requirements and Evaluation Criteria (Track Changes).pdf PDF
Amendment 0002.pdf PDF
Amendment 0002 - Bidding Schedule.pdf PDF
Amendment 0001.pdf PDF
Amendment 0001 - Submission Requirements and Evaluation Criteria.pdf PDF
Specifications - Volume I.pdf PDF
Contractor Appendix Binder.pdf PDF
Specifications - Volume II.pdf PDF
JA 05 - AMAZ_Redacted.pdf PDF
JA 02 - JCI Fire_Redacted.pdf PDF
JA 03 - JCI ESS_Redacted.pdf PDF
JA 04 - Assa Abloy_Redacted.pdf PDF
JA (Class) - Interior Finishes_Redacted.pdf PDF
JA 01 - Siemens_or_JCI HVAC BAS_Redacted.pdf PDF
Submission Requirements and Evaluation Criteria.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .