WWYK250063-04March2026.pdf
PDF 76 KB Posted
- Solicitation number
- FA813726R0026
About this file
This is an overhead door electrical specifications drawing (Sheet E-104) for a facility upgrade project located in Tinker AFB, Oklahoma. The drawing details the electrical requirements for two overhead doors (103A and 105A) serving a loading dock and adjacent offices and material testing rooms. Door 103A requires 115 VAC single-phase power, while Door 105A requires 230 VAC single-phase power. Both doors utilize standard 24V, 3-button control stations (open, close, stop) mounted in NEMA 1 flush interior enclosures.
The electrical scope of work mandates that contractors safely remove, preserve, and reinstall all existing electrical components currently located in or within walls designated for fire-rated assembly upgrades, coordinating all work with the general contractor. Affected components include power and lighting panels, junction boxes, conduits, wiring devices, fire alarm devices, and low-voltage cabling. Contractors must de-energize all affected systems prior to removal, complete reinstallation with full functional testing and re-energization upon completion, and ensure all work complies with current NEC codes and relevant life safety standards. The wall to be upgraded to a fire-rated wall requires electrical work on both sides of the installation.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
35%
DESIGN
W W
YK
IN
ST
AL
L R
EA
CT
V
II F
AC
ILI
TY
B9
1, V1
O
C T
TE
PA
-C
SA
G
D P
ER
R
Y
E-104
T
KI
SE
R
C H
IX
O
N
En gr
\D es ig n\ s\
\2
3\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
OV
ER
HE
AD
D
OO
R
EL
EC
TR
IC
AL
SP
EC
IF
IC
AT
IO
NS
E-104
OVERHEAD DOOR ELECTRICAL SPECIFICATIONS
SCALE: 1/8" = 1'-0"
PROJECT LOCATION
B9001 KEY PLAN
OVERHEAD DOOR - ELECTRICAL SPECIFICATIONS
DOOR NO. POWER
103A 115 VAC - SINGLE PHASE
105A 230 VAC - SINGLE PHASE
CONTROL STATION
24V, 3 BUTTON, OPEN,
CLOSE, STOP (STD)
24V, 3 BUTTON, OPEN,
CLOSE, STOP (STD)
CONTROL STATION MOUNTING
NEMA 1
FLUSH INTERIOR
NEMA 1
FLUSH INTERIOR
NOTES
1. COORDINATE CONTROL STATION INSTALLATION WITH
CONSTRUCTION OF RATED WALL ASSEMBLIES
1. COORDINATE CONTROL STATION INSTALLATION WITH
CONSTRUCTION OF RATED WALL ASSEMBLIES
AI
SL
E
U
U
V
V
W
W
W
V
U
LOADING
DOCK
OFFICE 2
MATERIAL TESTING ROOM-1
OFFICE 1
MATERIAL TESTING ROOM-2
PB
UL18-27
M
103A
PB
U18L-33, 35
105A
File details come from the government source that posted it. Updated .