10 22 13.pdf

PDF 22 KB Posted

Attached to
WWYK250063 - INSTALL REACT VII FACILITY, B9001, POST V19
Solicitation number
FA813726R0026
Issued by

About this file

This is a technical specification document for wire mesh partitions at Tinker Air Force Base, Oklahoma, dated April 2019 (Section 10 22 13).

The specification establishes requirements for wire mesh partitions in two duty classifications: normal duty for standard industrial use and heavy duty for extra heavy industrial use. Normal duty partitions utilize 10 gauge wire with 1-1/2 inch mesh, while heavy duty partitions use 6 gauge wire with 2 inch mesh. All partitions must include complete assemblies with fasteners, capping bars, adjustable floor sockets, bracing, doors, hardware, and other components necessary for rigid installation. Material requirements mandate that metal posts and framing contain a minimum of 15 percent post-consumer recycled content and wire materials contain a minimum of 50 percent post-industrial recycled content. Steel materials must conform to ASTM A36/A36M for structural steel and AISI SG03-3 for cold-formed steel. The specification includes detailed dimensional requirements for vertical frames (1-1/4 by 5/8 inch channels for normal duty; 1-1/2 by 3/4 by 1/8 inch channels for heavy duty), horizontal frames, center reinforcing bars, capping bars, corner posts, and line posts that vary by partition height. Doors must feature mortise-type locks with six-pin tumblers and specified hinge configurations. Service windows are 24 inches wide by 15 inches high with slide-up mechanisms. Installation requirements mandate plumb, level, and true-to-line alignment within 1/8 inch tolerance per 10 feet, with expansion bolt anchoring and specified bolt spacing. All ferrous metal surfaces must be phosphate-treated and painted with gray enamel in the shop, with touch-up provisions for field damage.

View the file

Other files

File Type Posted
250063_ATT 10_Submittal Register.xlsx XLSX spreadsheet
26 05 73 POWER STUDIES.pdf PDF
26 20 00.pdf PDF
09 90 00.pdf PDF
23 09 13.pdf PDF
23 36 00.00 40.pdf PDF
08 71 00.pdf PDF
05 40 00.pdf PDF
10 14 00.10.pdf PDF
08 33 23.pdf PDF
08 11 13.pdf PDF
07 92 00.pdf PDF
01 33 16.00 10.pdf PDF
01 32 16.00 20.pdf PDF
image.png PNG image
250063 React VII_Hardware schedule 25MAR26 JL.xlsx XLSX spreadsheet
JOIST SPECIAL INSPECTIONS.xlsx XLSX spreadsheet
ELECTRICAL PANEL SCHEDULE U18L.xlsx XLSX spreadsheet
esvEH_singledual_2023_V2.pdf PDF
lk406gn05t4_spec.pdf PDF
2_-_HE05-JINV-S11EE---GNT---L_001.pdf PDF
ERV Schedule_TAFB B9001_O-212477.xlsx XLSX spreadsheet
4500-CIVIL.pdf PDF
250063_ATT 10_Submittal Register.pdf PDF
250063_ATT 9_SOW.pdf PDF
250063_ATT 11_Drawings.pdf PDF
WWYK250063-04March2026.pdf PDF
2020 TAFB Facility Standard.pdf PDF
2026 TAFB Electrical Standard - Signed.pdf PDF
SOW Att 02a_Controlled Area Training.pptx PPTX presentation
SOW Att 02c_Controlled Area Training - Certificate.pdf PDF
22 00 00.pdf PDF
28 31 76.pdf PDF
23 09 23.02.pdf PDF
07 14 00.pdf PDF
08 51 23.pdf PDF
10 44 16.pdf PDF
07 21 16.pdf PDF
00 72 00.pdf PDF
00 71 00.pdf PDF
01 78 00.pdf PDF
01 33 00.pdf PDF
000_TABLE OF CONTENTS.pdf PDF
01 78 23.pdf PDF
esvperf_singledual_2023_V2.pdf PDF
lrad331965pd_spec.pdf PDF
REACT VII SA-01.pdf PDF
TAFB B9001 VAV Schedule.pdf PDF
ARCH-COMBINED.pdf PDF
4500-MUG.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 10 22 13

WI RE MESH PARTI TI ONS

04/17

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

AMERI CAN I RON AND STEEL I NSTI TUTE ( AI SI )

AI SI SG03- 3 ( 2002; Suppl 2001- 2004; R 2008) Col d- For med St eel Desi gn Manual Set

ASTM I NTERNATI ONAL ( ASTM)

ASTM A36/ A36M ( 2014) St andar d Speci f i cat i on f or Car bon St r uct ur al St eel

1. 2 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Wi r e Mesh Par t i t i ons

Show l ayout , det ai l s, mat er i al s, di mensi ons, f i ni shes, and al l i nf or mat i on necessar y f or f abr i cat i on and i nst al l at i on.

SD- 03 Pr oduct Dat a

Wi r e Mesh Par t i t i ons

Submi t f or each t ype of par t i t i on, door , and wi ndow.

1. 3 DELI VERY, STORAGE, AND HANDLI NG

Del i ver mat er i al s i n manuf act ur er ' s or i gi nal , unopened cont ai ner s or packagi ng wi t h l abel s i nt act and l egi bl e. Del i ver , st or e, and handl e mat er i al s so as t o pr event damage. Repl ace damaged or def ect i ve mat er i al s wi t h new.

1. 4 DESCRI PTI ON OF WORK

Wi r e mesh par t i t i ons must be al l wi r e t ype or sheet met al base t ype, nor mal dut y f or nor mal i ndust r i al use, heavy dut y f or ext r a heavy i ndust r i al use. Pr ovi de par t i t i ons compl et e wi t h f ast ener s, cappi ng bar s, adj ust abl e f l oor socket s, br aci ng, door s, har dwar e, and ot her i t ems necessar y f or a compl et e, useabl e, and r i gi d i nst al l at i on.

Apr i l 2019 Page 1 SECTI ON 10 22 13

PART 2 PRODUCTS

2. 1 PRODUCT SUSTAI NABI LI TY CRI TERI A

For pr oduct s i n t hi s sect i on, wher e appl i cabl e and t o ext ent al l owed by per f or mance cr i t er i a, pr ovi de and document t he f ol l owi ng:

2. 2 MATERIALS

Met al post and f r ami ng mat er i al s l i s t ed bel ow must cont ai n a mi ni mum of 15 per cent post - consumer r ecycl ed cont ent and wi r e mat er i al s must cont ai n a mi ni mum of 50 per cent post - i ndust r i al r ecycl ed cont ent . Pr ovi de dat a i dent i f y i ng per cent age of r ecycl ed cont ent f or met al post and f r ami ng mat er i al s. Al so pr ovi de dat a i dent i f y i ng per cent age of r ecycl ed cont ent f or wi r e mat er i al s.

2. 2. 1 St eel Shapes, Pl at es, and Bar s

ASTM A36/ A36M.

2. 2. 2 Col d- For med St eel

AI SI SG03- 3.

2. 2. 3 Wi r e Mesh

Car bon st eel wi r e, woven di amond mesh, i nt er medi at e cr i mped.

2. 2. 4 Fl oor Socket s

Cast or f or ged st eel or duct i l e i r on, adj ust abl e, appr oxi mat el y 2- 1/ 2 i nches hi gh.

2. 3 NORMAL DUTY PARTI TI ONS

2. 3. 1 Wi r e Mesh

10 gage wi r e, 1- 1/ 2 i nch mesh.

2. 3. 2 Ver t i cal Fr ames

1- 1/ 4 by 5/ 8 i nch col d- r ol l ed C sect i on channel s or 1- 1/ 4 by 5/ 8 by 1/ 8 i nch channel s. Pr ovi de onl y C channel s wher e f r ames ar e i nst al l ed t oe t o t oe wi t hout post s.

2. 3. 3 Hor i zont al Fr ames

1 by 5/ 8 i nch channel s.

2. 3. 4 Cent er Rei nf or ci ng Bar

One 1 by 1/ 2 by 1/ 8 i nch channel wi t h al l wi r es woven t hr ough, or t wo 1 by 3/ 8 by 1/ 8 i nch channel s bol t ed t oget her wi t h mesh i n bet ween.

2. 3. 5 Cappi ng Bar

2- 1/ 4 by one by 1/ 8 i nch channel or 2 by 1/ 4 i nch f l at bar .

Apr i l 2019 Page 2 SECTI ON 10 22 13

2. 3. 6 Cor ner Post s

St r uct ur al st eel angl es, 1- 1/ 4 by 1- 1/ 4 by 1/ 8 i nch.

2. 3. 7 Li ne Post s

Unl ess ot her wi se i ndi cat ed, pr ovi de par t i t i ons mor e t han 12 f eet hi gh wi t h f l at bar l i ne post s bol t ed bet ween ver t i cal f r ame channel s. Si zes of post s must be as f ol l ows:

Par t i t i on Hei ght Si ze of Post s

12 f eet t o 14 f eet 8 i nches 1- 3/ 4 by 5/ 16 i nch or 2 by 1/ 4 i nch

14 f eet 8 i nches t o 19 f eet 8 i nches 2- 1/ 2 by 5/ 16 i nch

19 f eet 8 i nches t o 23 f eet 8 i nches 3 by 5/ 16 i nch

2. 3. 8 Hi nged Door s

Fr ames must be 1- 1/ 4 by 1/ 2 by 1/ 8 i nch channel s wi t h 1- 1/ 4 by 1/ 8 i nch f l at bar cover on t op and bot t om r ai l s and on hi nge st i l e and a 1- 3/ 8 by 3/ 4 by 1/ 8 i nch angl e r i vet ed t o t he l ock st i l e. Pr ovi de 1 1/ 2 pai r s of r egul ar wei ght , wr ought st eel , non- r emovabl e pi n, but t hi nges r i vet ed or wel ded t o t he door and t he door openi ng f r ame f or each door .

2. 3. 9 Sheet Met al Base

Hot - or col d- r ol l ed sheet st eel , not l i ght er t han 16 gage.

2. 4 HEAVY DUTY PARTI TI ONS

2. 4. 1 Wi r e Mesh

6 gage wi r e, 2 i nch mesh.

2. 4. 2 Panel Fr ames

1- 1/ 2 by 3/ 4 by 1/ 8 i nch st eel channel s.

2. 4. 3 Cent er Rei nf or ci ng Bar

One 1- 1/ 2 by 3/ 4 by 1/ 8 i nch channel wi t h al l wi r es woven t hr ough, or t wo 1- 1/ 4 by 3/ 8 by 1/ 8 i nch channel s bol t ed t oget her wi t h mesh i n bet ween.

2. 4. 4 Cappi ng Bar

St r uct ur al st eel channel , 3 i nch by 4. 1 pounds.

2. 4. 5 Cor ner Post s

St r uct ur al st eel angl es, 1- 3/ 4 by 1- 3/ 4 by 1/ 8 i nch.

2. 4. 6 Li ne Post s

Unl ess ot her wi se i ndi cat ed, pr ovi de par t i t i ons wi t h f l at bar l i ne post s bol t ed bet ween ver t i cal f r ame channel s. Si zes of post s must be as f ol l ows:

Apr i l 2019 Page 3 SECTI ON 10 22 13

Par t i t i on Hei ght Si ze of Post s

7 f eet t o 12 f eet 2- 1/ 2 by 5/ 16 i nch

12 f eet t o 16 f eet 3 by 5/ 16 i nch or 2- 1/ 2 by 3/ 8 i nch

16 f eet t o 20 f eet 3- 1/ 2 by 5/ 16 i nch

2. 4. 7 Hi nged Door s

Fr ames must be 1- 1/ 2 by 3/ 4 by 1/ 8 i nch channel s wi t h 1- 1/ 2 by 1/ 8 i nch f l at bar cover on t op and bot t om r ai l s and on hi nge st i l e and a 1- 5/ 8 by 7/ 8 by 1/ 8 i nch angl e r i vet ed t o t he l ock st i l e. Pr ovi de 1- 1/ 2 pai r s of heavywei ght , wr ought st eel , non- r emovabl e pi n, but t hi nges r i vet ed or wel ded t o t he door and t he door openi ng f r ame f or each door .

2. 5 SLI DI NG DOORS

Fr ames must be 1- 1/ 2 by 3/ 4 by 1/ 8 i nch channel s wi t h 1- 1/ 2 by 1/ 8 i nch f l at bar cover al l ar ound. Pr ovi de t wo f our - wheel , r ol l er bear i ng hanger s and st eel box t r ack f or each door .

2. 6 DOOR OPENI NG FRAMES

Pr ovi de f r ames t he same si ze and shape as t he ver t i cal f r ames f or t he mesh panels.

2. 7 LOCKS

Pr ovi de each door wi t h a mor t i se t ype l ock wi t h a s i x- pi n t umbl er l ock cyl i nder on t he out si de and a r ecessed knob on t he i nsi de.

2. 8 SERVI CE WI NDOWS

Sl i de up t ype, mount ed i n st andar d mesh panel r ei nf or ced wi t h channel t r acks. Openi ng must be 24 i nches wi de by 15 i nches hi gh unl ess ot her wi se i ndi cat ed. Pr ovi de t wo spr i ng l oaded l at ches, oper abl e onl y f r om t he i nsi de, t o l ock wi ndow i n open and cl osed posi t i ons. For m shel f of 12 gage sheet st eel , 12 i nches deep by 25 i nches wi de, unl ess ot her wi se indicated.

2. 9 FABRICATION

2. 9. 1 St andar d Panel s

Wi r e must be woven i nt o di amond mesh, i nt er medi at e cr i mped, and secur el y c l i nched t o f r ames. Joi nt s must be mor t i sed and t enoned. Wi r e must be cont i nuous at cent er r ei nf or ci ng bar s, ei t her woven t hr ough a s i ngl e channel or bol t ed bet ween t wo channel s. Panel ver t i cal f r ames must have 1/ 4 i nch bol t hol es 12 i nches o. c. f or nor mal dut y par t i t i ons; and 3/ 8 i nch bol t hol es 18 i nches o. c. f or heavy dut y par t i t i ons.

2. 9. 2 Sheet Met al Base Panel s

Upper por t i on must be as speci f i ed f or st andar d panel s, except t hat t he wi r e must be cl i nched i nt o t he cent er r ei nf or ci ng bar . For m sheet st eel t o f i t bet ween t he panel f r ames and secur el y bol t t o t he f r ames.

Apr i l 2019 Page 4 SECTI ON 10 22 13

2. 9. 3 Door s and Ser vi ce Wi ndows

Const r uct i on must be si mi l ar t o t hat speci f i ed f or panel s. Wi r e mesh must be t he same as t hat used i n t he adj acent par t i t i on panel s.

2. 9. 4 Finish

Thor oughl y c l ean f er r ous met al , t r eat wi t h phosphat e, and pai nt wi t h gr ay enamel i n t he shop.

PART 3 EXECUTI ON

3. 1 INSTALLATION

3. 1. 1 Wi r e Mesh Par t i t i ons

I nst al l pl umb, l evel , and t r ue t o l i ne, wi t hi n a t ol er ance of 1/ 8 i nch i n 10 f eet or t he hei ght or r un of t he par t i t i on, i f l ess t han 10 f eet .

Anchor f l oor socket s t o t he f l oor wi t h expansi on bol t s. Bol t ver t i cal f r ames and post s t oget her wi t h 1/ 4 i nch bol t s 12 i nches o. c. f or nor mal dut y par t i t i ons; and 3/ 8 i nch bol t s 18 i nches o. c. f or heavy dut y par t i t i ons. Secur e t op f r ames t o a cont i nuous cappi ng bar wi t h 1/ 4 i nch di amet er U bol t s not mor e t han 28 i nches o. c.

3. 1. 2 Door s and Ser vi ce Wi ndows

I nst al l i n accor dance wi t h t he manuf act ur er s ' r ecommendat i ons. Adj ust as r equi r ed so t hat door s , wi ndows, and har dwar e oper at e f r eel y and pr oper l y.

3. 1. 3 Bracing

Br ace f r ee st andi ng par t i t i ons mor e t han 20 f eet i n l engt h, at i nt er val s not gr eat er t han 20 f eet wi t h a st eel channel br ace connect ed t o t he cappi ng bar and anchor ed t o t he bui l di ng wal l or f r ami ng member ; wi t h a st r uct ur al st eel I sect i on or t ube post wel ded t o a 9 by 9 i nch st eel base pl at e anchor ed t o t he f l oor wi t h 4 expansi on bol t s; or as i ndi cat ed.

3. 1. 4 Touch-Up

Cl ean and pai nt scr at ches, abr asi ons, and ot her damage t o shop pai nt ed sur f aces t o mat ch t he shop- appl i ed f i ni sh.

Repai r mi nor sur f ace r ust ar eas. Cl ean and pr i me wi t h r ust i nhi bi t i ve pr i mer pai nt . Appl y f i nal pai nt t o mat ch shop- appl i ed f i ni shes.

- - End of Sect i on - -

Apr i l 2019 Page 5 SECTI ON 10 22 13

File details come from the government source that posted it. Updated .