This document includes a sound masking functional diagram and details for a federal contract opportunity to construct an Operations Support Facility at Fort Bragg, North Carolina. The scope of work involves constructing an approximately 36,000 square foot facility to sensitive compartmented information standards. It includes office, meeting, training, and support spaces. Systems include fire detection and suppression, mass notification, cyber security, electrical, HVAC, communications infrastructure, and security features. The period of performance is 540 calendar days. The contract will be firm-fixed price awarded by the Department of the Army Corps of Engineers Engineering District Wilmington. Solicitation number is W912PM and opportunity name is PN 92594 SOF Operations Support Facility.

View the file

Other files for this federal contract opportunity

Other files attached to PN 92594 SOF Operations Support Facility, newest first.
File Type Posted
PN92594_W912PM19R00210005.pdf PDF
PN92594_0005_Technical Summary of Changes.pdf PDF
PN 92594_RTA SPECS_VOL 01.pdf PDF
FY20PN92594A-412.pdf PDF
FY20PN92594A-601.pdf PDF
FY20PN92594A-602.pdf PDF
FY20PN92594A101.pdf PDF
FY20PN92594A-531.pdf PDF
FY20PN92594A-402.pdf PDF
PN92594_W912PM19R00210004.pdf PDF
PN92594_0003_Technical Summary of Changes.pdf PDF
PN92594_W912PM19R00210003.pdf PDF
08 33 23.pdf PDF
03 45 00.pdf PDF
FY20PN92594IN101.pdf PDF
FY20PN92594T101.pdf PDF
10 44 16.pdf PDF
FY20PN92594T102.pdf PDF
FY20PN92594M-501.pdf PDF
FY20PN92594M-503.pdf PDF
FY20PN92594IN601.pdf PDF
FY20PN92594A-101.pdf PDF
FY20PN92594A-410.pdf PDF
FY20PN92594T504.pdf PDF
01 33 00.00 37 Submittal Register.pdf PDF
60584960 Table of Contents.pdf PDF
FY20PN92594CG101.pdf PDF
FY20PN92594IN102.pdf PDF
FY20PN92594S-001.pdf PDF
FY20PN92594L-101.pdf PDF
PN 92594_RTA SPECS_VOL 05 (Amend0001).pdf PDF
Technical Summary of Changes to W912PM19R0021-0001_pn92594.pdf PDF
Site Visit Sign In Roster 92594 .pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
Show all 50

PN 92594 SOF Operations Support Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SMCM

TO FIRE ALARM/LIFE

SAFETY PANEL

S2 S2

VESTIBULE AND LOBBY

COMM ROOM 110

FIRST FLOOR

SECOND FLOOR

SMCM

TO FIRE ALARM/LIFE

SAFETY PANEL

S2 S2

COORIDOR 2000

AND VESTIBULES

COMM ROOM 210

S2 S2S2S2

COORIDOR 2000

AND VESTIBULES

S2S2

27.43

27.43

TO LAN

TO LAN

GENERAL NOTES THIS SHEET:

A. LAYOUT IS LOGICAL. NOT ALL EQUIPMENT, DEVICES AND QUANTITIES ARE SHOWN, FOR

REPRESENTATION PURPOSES ONLY.

B. SEE RCP FLOOR PLANS FOR SOUND MASKING EMITTER LOCATIONS.

C. WALL MOUNT SOUND MASKING CONTROL MODULE (SMCM) IN COMM ROOMS. PROVIDE 120V POWER

RECEPTACLE FOR EACH SMCM. COORDINATE MOUNTING LOCATIONS IN COMM ROOMS WITH COR.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

1 2 3 4 5

A

F O

R T

B R

A G

G N

O R

T H

C A

R O

L

IN

A S

O F

O P

E R

A T

IO

N

S F

A C

IL

IT

Y F

Y

P

N

W

IL

M

IN

G T

O N

D

IS

T

R

IC

T W

IL

M

IN

G

T O

N N

O R

T H

C A

R O

L

IN

A

A E

C O

M S

E R

V

IC

E S

IN

C

S

J E

F F

E R

S O

N S

T S

T E

R O

A N

O K

E V

A

/2

/1

7 8 9 10

B

C

D

E

F

G

T M

J

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

-W P

M R

TA501

S O

U N

D M

A S

K

IN

G F

U N

C T

IO

N

A L D

IA

G

R A

M

A A

D

IL

M A

N

J M

A R

T

IN

E L A

S W

A Y F Y

P

N T

A .d w g

READY TO ADVERTISE

NO SCALE

SOUND MASKING LOGIC DIAGRAM

SHEET KEYNOTES:

27.43 CATEGORY 6A UTP CABLE. TYPICAL FOR ALL INTERCONNECTIONS EACH FLOOR.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D

IN

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

M A

R

Sheets
TA501 - SOUND MASKING FUNCTIONAL DIAGRAM

File details come from the government source that posted it. Updated .