FY20PN92594T504.pdf

PDF 26 KB Posted

Attached to
PN 92594 SOF Operations Support Facility Federal contract opportunity
Solicitation number
W912PM
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

This document includes a federal solicitation for the construction and design of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work involves building an approximately 36,000 square foot facility to sensitive compartmented information standards, including offices, conference rooms, training areas, medical exam rooms, server rooms, parking, utilities, security and fire protection systems. Sustainability, energy efficiency, and accessibility requirements are also included. Comprehensive interior design services are required. The period of performance is 540 calendar days. The resultant contract will be firm-fixed price awarded by the Department of the Army Corps of Engineers Engineering District Wilmington. The solicitation number is W912PM19R0021.

View the file

Other files for this federal contract opportunity

Other files attached to PN 92594 SOF Operations Support Facility, newest first.
File Type Posted
PN92594_W912PM19R00210005.pdf PDF
FY20PN92594A-602.pdf PDF
FY20PN92594IF601.pdf PDF
FY20PN92594A-102.pdf PDF
FY20PN92594A-412.pdf PDF
FY20PN92594A-601.pdf PDF
PN92594_0003_Technical Summary of Changes.pdf PDF
PN92594_W912PM19R00210003.pdf PDF
FY20PN92594T101.pdf PDF
10 44 16.pdf PDF
FY20PN92594T102.pdf PDF
FY20PN92594M-501.pdf PDF
FY20PN92594M-503.pdf PDF
03 30 00.00 10.pdf PDF
01 45 35.pdf PDF
PN92594_0002_Technical Summary of Changes.pdf PDF
FY20PN92594M-602.pdf PDF
PN92594_W912PM19R00210002.pdf PDF
FY20PN92594MP102.pdf PDF
08 33 23.pdf PDF
03 45 00.pdf PDF
FY20PN92594IN101.pdf PDF
FY20PN92594TA501.pdf PDF
FY20PN92594IN601.pdf PDF
FY20PN92594A-101.pdf PDF
FY20PN92594A-410.pdf PDF
01 33 00.00 37 Submittal Register.pdf PDF
PN 92594_RTA SPECS_VOL 01 (Amend0001).pdf PDF
PN92594_W912PM19R00210001.pdf PDF
PN 92594_RTA SPECS_VOL 05 (Amend0001).pdf PDF
Technical Summary of Changes to W912PM19R0021-0001_pn92594.pdf PDF
Site Visit Sign In Roster 92594 .pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
Show all 50

PN 92594 SOF Operations Support Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. REFER TO SHEET T-001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

B. INSTALL PERMANENT DETECTABLE TRACER WIRE IN ALL DUCT BANK DUCTS

PER I3A SECTIONS 3.5.10.2 AND 3.5.10.4.

C. INSTALL FABRIC MESH INNERDUCT, 3-3" CELL, IN EACH DUCT BANK DUCT PER

I3A SECTIONS 3.7.8 AND 3.7.8.4.

GENERAL NOTES THIS SHEET:

3"

3"

3"

3" 3" 3"

DUCT WITH (1) 25-PAIR UTP

COPPER (PART OF CLIN0005) AND

(1) GREEN 96-STR OS2 FIBER

6" PVC SCH. 40 CONDUIT, TYP.

DUCT WITH (1) YELLOW

96-STR OS2 FIBER

PROVIDE 2" CONCRETE MAT

BACKFILL

EXCAVATION

NEW AGGREGATE BASE

COURSE TO MATCH EXISTING

6" WARNING TAPE APPROX. 1'-0"

BELOW FINISH GRADE

FINISHED GRADE OR BUILDING SLAB

EXISTING BASE COURSE

DUCT WITH (1) BLUE 96-STR OS2

FIBER (PART OF CLIN0004)

DUCT WITH (1) RED

96-STR OS2 FIBER

(4) #6 REINFORCING BARS

M

IN

IM

U

M

METALLIC

CONDUIT

DIELECTRIC LINK THREADED

COUPLING SCHEDULE 80 PVC,

UL LISTED FOR THE

APPLICATION

PROVIDE 1/2" MINIMUM

SEPARATION BETWEEN

STEEL CONDUITS

SECURE SIDE NON-SECURE SIDE

METALLIC

CONDUIT

SEAL ENTIRE PERIMETER UL

CLASSIFIED FIRE STOPPING

SEALANT AND MINERAL WOOL

BACKUP

WALL

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E

1 2 3 4 5

A

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

AE

C

O M

S

ER

VI

C

E S, IN

C

S J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

K E

VA

/2

4/

7 8 9 10

B

C

D

E

F

G

TM

J

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

-W

2P M

R

T-504

TE

LE

C O

M D

ET

AI

LS

C . B

EN

N

ET

T

B.

M

AR

TI

R

P.

V

IT

O

N

E FY

PN

4T -5

.d w g

READY TO ADVERTISE

NO SCALE

TELECOM UG DUCT BANK DETAIL

NO SCALE

TYPICAL DI-ELECTRIC CONDUIT PENETRATION

DETAIL

MA

RK

DE

SC

RI

PT

IO

N

DA

TE

RE

VI

SE

D

IN

A

CC

O R

DA

NC

E

W

IT

H

AM

EN

DM

EN

T

M

AR

File details come from the government source that posted it. Updated .