FY20PN92594A-602.pdf

PDF 88 KB Posted

Attached to
PN 92594 SOF Operations Support Facility Federal contract opportunity
Solicitation number
W912PM
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

This federal solicitation requests proposals for the construction and design of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes the construction of an approximately 36,000 square foot facility with spaces such as offices, conference rooms, training rooms, medical exam areas, latrines, mechanical and electrical rooms, and secure server rooms. The facility is to be built to sensitive compartmented information standards. Additional requirements include building systems for fire protection, power, communications, security, and sustainability/energy measures. The work must be completed within 540 calendar days of award. The resultant contract will be a firm-fixed price agreement. The soliciting agency is the Department of the Army Corps of Engineers Engineering District Wilmington.

View the file

Other files for this federal contract opportunity

Other files attached to PN 92594 SOF Operations Support Facility, newest first.
File Type Posted
PN92594_W912PM19R00210005.pdf PDF
FY20PN92594IF601.pdf PDF
FY20PN92594A-102.pdf PDF
FY20PN92594A-412.pdf PDF
FY20PN92594A-601.pdf PDF
PN92594_0003_Technical Summary of Changes.pdf PDF
PN92594_W912PM19R00210003.pdf PDF
03 30 00.00 10.pdf PDF
01 45 35.pdf PDF
PN92594_0002_Technical Summary of Changes.pdf PDF
FY20PN92594M-602.pdf PDF
PN92594_W912PM19R00210002.pdf PDF
FY20PN92594MP102.pdf PDF
FY20PN92594T101.pdf PDF
10 44 16.pdf PDF
FY20PN92594T102.pdf PDF
FY20PN92594M-501.pdf PDF
FY20PN92594M-503.pdf PDF
08 33 23.pdf PDF
03 45 00.pdf PDF
FY20PN92594IN101.pdf PDF
FY20PN92594TA501.pdf PDF
FY20PN92594IN601.pdf PDF
FY20PN92594A-101.pdf PDF
FY20PN92594A-410.pdf PDF
FY20PN92594T504.pdf PDF
01 33 00.00 37 Submittal Register.pdf PDF
PN 92594_RTA SPECS_VOL 01 (Amend0001).pdf PDF
PN92594_W912PM19R00210001.pdf PDF
PN 92594_RTA SPECS_VOL 05 (Amend0001).pdf PDF
Technical Summary of Changes to W912PM19R0021-0001_pn92594.pdf PDF
Site Visit Sign In Roster 92594 .pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
Show all 50

PN 92594 SOF Operations Support Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. REFER TO SHEET G-003 FOR ABBREVIATIONS.

B. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS AND

SYMBOLS.

C. REFER TO ARCHITECTURAL PLANS FOR DOOR TAG LOCATIONS.

D. COORDINATE REQUIRED FIRE RATED DOORS WITH FIRE RATED

PARTITIONS, REFER TO LIFE SAFETY PLAN.

E. FRAME DEPTH FOR WRAP-AROUND HOLLOW METAL FRAMES SHALL

BE THE WIDTH OF THE PARTITION PLUS 1-1/8" OR AS NOTED. SEE

PARTITION TYPES, SHEET A-601.

F. SEE SPECIFICATIONS FOR DOOR HARDWARE SETS. REVIEW ALL

HARDWARE SETS AND LOCK FUNCTIONS WITH CONTRACTING

OFFICER PRIOR TO DEVELOPING FINAL HARDWARE SETS.

G. REFER TO ELECTRICAL AND TELECOM DRAWINGS FOR POWER

AND/OR CARD READER ACCESS REQUIREMENTS.

H. DOORS LOCATED NEAR PERPENDICULAR WALLS ARE TO BE SET

WITH FRAME 4" FROM FACE OF PERPENDICULAR WALL, UNO.

I. SEE SH IN601 FOR FINISH OF FIELD PAINTED HM FRAMES AND HM

DOORS.

J. REFER TO TY SERIES DRAWINGS FOR DOOR DETAIL NUMBERS IN

SECURITY SYSTEM REQUIREMENTS.

K. GAPS AROUND DOORS IN SMOKE PARTITIONS ARE TO MEET THE

LIMITS OF NFPA 80. PROVIDE LATCHING AND SELF-CLOSING DOORS

FOR DOORS IN SMOKE PARTITIONS.

L. FINISH FOR ALL WOOD DOORS TO MATCH WV-1 UNO. REFER TO

IN601 FOR FINISH INFORMATION.

M. AT STC RATED DOORS, PROVIDE DOUBLE 4", MIN 18 GA METAL STUD

BOX BEAM ATTACHED TO STRUCTURE TOP AND BOTTOM.

GENERAL NOTES THIS SHEET:

GL-1: VISION GLASS, CLEAR, LAMINATED, STC 50

GL-2: FRAMELESS GLASS DOOR CLEAR GLAZING

GL-3: FRAMELESS GLASS DOOR CLEAR GLAZING WITH FROSTED FILM

GL-4: 3/8" TEMPERED GLASS DISPLAY CASE SHELVING AND DOORS

GLAZING TYPES:

H

W

H

W W

W

SEE PLAN

VARIES

6" 6"

H

H

W

H

W

A B C D OVHD

GL AS

SCHED

2" H

2" W 2"

2" H

2" W W 2"

4" H

2" W 2"

4" H

4" W 4"

F1 F2 F3 F4

2" H

2" W W 2"

2' -0

2"

F2A

4' 2' 0 4' 8' 1/4"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E:

1 2 3 4 5

A

GRAPHIC SCALES

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

AR

O

LI

N

A

AE

C

O M

S

ER

VI

C

ES

, I

N C

S J

EF

FE

R

SO

N S

T

ST

E

R

O

AN

O

KE

V A

/2

4/

7 8 9 10

B

C

D

E

F

G

TM

J

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

-W

2P M

R

A-602

D O

O R

S C

H

ED

U

LE

C

LB

C

LB

R M

G

FY

PN

4A

-6

.d w g

READY TO ADVERTISE

DOOR SCHEDULE

DOOR

NO.

DOOR

TYPE

DOOR INFORMATION FRAME INFORMATION

HW

SET

SECURITY

DOOR

DETAIL COMMENTS

SIZE DOOR

MATL

DOOR

FINISH U/C

GL

Type

FIRE

RATING

FRAME

TYPE

FRAME

MATL

FRAME

FINISH

DETAILS

WIDTH HEIGHT HEAD JAMB SILL

1513 A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 3/A-610 4/A-610 19 SMOKE RATED

33 A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 9/A-610

SIM

10/A-610

SIM

1 3/TY501

21 A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 9/A-610 10/A-610 35

22 A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 9/A-610 10/A-610 35

210 A 3' - 6" 7' - 0" WD PREFIN 45 MIN F1 HM PNT 5/A-610 6/A-610 29 2/TY501 STC 45

220 A 4' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 20

230 A 3' - 0" 7' - 0" WD PREFIN 3/4" F1 HM PNT 3/A-610 4/A-610 09

240 A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 3/A-610 4/A-610 19 SMOKE RATED

250 A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 1/A-610 2/A-610 08

250A A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 3/A-610 4/A-610 07

2001 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 10

2002A A 3' - 0" 7' - 0" WD PREFIN 1/4" F1 HM PNT 1/A-610 2/A-610 15

2002B A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14.1 STC 50

2003 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 19 SMOKE RATED

2100 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14.3 STC 50

2101 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2102 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2103 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2104 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 15

2200A A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14.3 STC 50

2200B A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14.3 STC 50

2202 C 3' - 0" 9' - 0" GL GL-2 - GL 7/A-610 8/A-610 43

2203 C 3' - 0" 9' - 0" GL GL-2 - GL 7/A-610 8/A-610 43

2204 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 16 STC 50

2205 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2206 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2207 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 23 SMOKE RATED

2300A A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 41 2/TY501 STC 50

2300B A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 33 3/TY501 STC 50

2300C A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14.4 3/TY501 STC 45

2300D A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 33 3/TY501 STC 45

2301 A 3' - 6" 7' - 0" WD PREFIN 45 MIN F1 HM PNT 5/A-610 6/A-610 29 2/TY501 STC 45

2302 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2303 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 16 STC 50

2305A B 2' - 6" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 45

2305B A 2' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 23.1

2306 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2307 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 15

2308 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2309 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 15

2310 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

2311 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

DOOR SCHEDULE

DOOR

NO.

DOOR

TYPE

DOOR INFORMATION FRAME INFORMATION

HW

SET

SECURITY

DOOR

DETAIL COMMENTS

SIZE DOOR

MATL

DOOR

FINISH U/C

GL

Type

FIRE

RATING

FRAME

TYPE

FRAME

MATL

FRAME

FINISH

DETAILS

WIDTH HEIGHT HEAD JAMB SILL

11A A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 9/A-610 10/A-610 35

11B A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 13/A-610 14/A-610 03 3/TY501

12A A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 9/A-610 10/A-610 35

12B A 3' - 0" 7' - 0" HM PNT 1 HR F3 HM PNT 13/A-610 14/A-610 03 3/TY501

110 A 3' - 6" 7' - 0" WD PREFIN 45 MIN F1 HM PNT 5/A-610 6/A-610 29.1 2/TY501 STC 45

120 A 3' - 6" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 38

130 A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 3/A-610 4/A-610 08

140 A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 3/A-610 4/A-610 19 SMOKE RATED

150 A 3' - 0" 7' - 0" WD PREFIN 1/2" F1 HM PNT 3/A-610 4/A-610 08

1001A A 3' - 6" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 31

1001B A 3' - 6" 7' - 0" HM PNT F1 HM PNT 11/A-610 12/A-610 04 4/TY501

1002A A 3' - 6" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 42 1/TY501 STC 45

1002B A 3' - 6" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 37

1003 A 3' - 6" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 36.1 3/TY501 STC 45

1004 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 12

1005 B 3' - 0" 7' - 0" WD PREFIN F2 HM PNT 3/A-610 4/A-610 45.1 SMOKE RATED

1006 A 3' - 6" 7' - 0" WD PREFIN 1 HR F3 HM PNT 9/A-610 10/A-610 24

1007 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 15

1008 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14 STC 50

1100 C 3' - 0" 8' - 0" GL GL-3 - GL 7/A-610 8/A-610 43

1101 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 14 STC 50

1102 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 14 STC 50

1103 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 14 STC 50

1104 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14 STC 50

1105 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 14 STC 50

1106A A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12.1

1106B A 3' - 0" 7' - 0" WD PREFIN 1/4" F1 HM PNT 3/A-610 4/A-610 15

1200 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 17

1201 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

1202 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

1203 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 13 STC 45

1300 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 14.2

1301 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 15

1302 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 12

1400A A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 36 STC 50

1400B A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 5/A-610 6/A-610 36 STC 50

1500A A 3' - 0" 7' - 0" HM PNT F1 HM PNT 3/A-610 4/A-610 32

1500B A 3' - 0" 7' - 0" HM PNT F1 HM PNT 11/A-610 12/A-610 05

1501AA A 3' - 0" 7' - 0" WD PREFIN 3/4" F1 HM PNT 3/A-610 4/A-610 07

1501AB A 3' - 0" 7' - 0" WD PREFIN 3/4" F1 HM PNT 1/A-610 2/A-610 08

1502AA A 3' - 0" 7' - 0" WD PREFIN 3/4" F1 HM PNT 3/A-610 4/A-610 07

1502AB A 3' - 0" 7' - 0" WD PREFIN 3/4" F1 HM PNT 1/A-610 2/A-610 08

1503A A 3' - 0" 7' - 0" HM PNT 1/2" F1 HM PNT 3/A-610 4/A-610 11 SMOKE RATED

1503B A 3' - 0" 7' - 0" HM PNT F1 HM PNT 3/A-610 4/A-610 18 SMOKE RATED

1503C OVHD 5' - 0" 8' - 0" STL PREFIN - STL 47 MANUAL OPERATION,

SMOKE RATED, FUSIBLE

LINK

1504 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 17

1505 D 3' - 8" 6' - 8" STL PREFIN F4 STL PNT 46 3/TY501 CLASS 5A ARMORY

DOOR AND

DUTCH-STYLE DAY GATE

1506 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 12

1507 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 12

1508A A 3' - 0" 7' - 0" WD PREFIN F3 HM PNT 9/A-610 10/A-610 25 SMOKE RATED

1508B A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 1/A-610 2/A-610 15

1509A A 4' - 0" 7' - 0" HM PNT F3 HM PNT 9/A-610 10/A-610 22 SMOKE RATED

1509B OVHD 8' - 0" 8' - 0" STL PREFIN - STL 47 ELECTRIC OPERATION

1510 4' - 0" 7' - 0" HM PNT F2A HM PNT 1/A-611 2/A-610

SIM

1511 A 3' - 0" 7' - 0" WD PREFIN F1 HM PNT 3/A-610 4/A-610 19.1

1512 A 3' - 6" 7' - 0" WD PREFIN 45 MIN F1 HM PNT 3/A-610 4/A-610 30.1 2/TY501 STC 45

1/4" = 1'-0"A-602

1 DOOR TYPES

1/4" = 1'-0"A-602

2 FRAME TYPES

OPNG FOR LVR

MA

RK

DE

SC

RI

PT

IO

N

DA

TE

RE

VI

SE

D

IN

A C C

OR

DA

N C E

W

IT

H

AM

EN

DM

EN

T

M

AR

2 0

1 1

Sheets
A-101 - FIRST FLOOR PLAN
A-102 - SECOND FLOOR PLAN
A-402 - STAIR PLANS AND SECTIONS
A-412 - EXAM ROOM ENLARGED PLAN AND ELEVATIONS
A-531 - INTERIOR DETAILS
A-601 - PARTITION TYPES
A-602 - DOOR SCHEDULE

File details come from the government source that posted it. Updated .