About this file
This solicitation requests proposals for the construction of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes building a 36,000 square foot facility to sensitive compartmented information standards. It will include office, training, medical, and operations areas along with necessary support facilities. The period of performance is 540 calendar days. Supporting requirements include utility connections, parking, security lighting, site work, and sustainability measures. Comprehensive interior design services are also required. The Department of the Army Corps of Engineers Engineering District Wilmington will award a firm-fixed price contract. The response deadline has passed and award is anticipated.
View the file
Other files for this federal contract opportunity
Show all 50
PN 92594 SOF Operations Support Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-301
4'-4" 16'-0" 122'-8" 16'-0"
'-5
'-7
'-7
'-1 0"
'-9
CORRIDOR
LOBBY
SECURITY
CORRIDOR
JANITOR
STAIR 1
ELEVATOR
ELEV MACH
ROOM
AUDITORIUM
1400A
OPEN OFFICE
GEAR STORAGE
WOMEN
COMM
ELEC
WOMEN
JANITOR
EQUIPMENT
LOCKERS
STAIR 2
WELLNESS
CONFERENCE
OFFICE
OFFICE
OFFICE
ARMS ROOM
TESTING AND
EQPT
OPEN OFFICE
CORR
1504MEN
MEN
EQUIPMENT
MAINTENANCE
AREA
PRINT/COPY
OPEN OFFICE
OPEN OFFICE
AV OFFICE
VEST
1502A
ELEC
TRAINING
FURN STORAGE
EXAM ROOM
OFFICE
OFFICE
WAITING
AV OFFICE
VEST
1501A
VESTIBULE
VESTIBULE
A-301
FIRST FLOOR
MECHANICAL
VESTIBULE
1500A
A-402
9'
-2
1500B
B
B
A
B
A
B
A
B
A
1106A
B
B
1502AB
AA
AA
A
1508B
A
B
1508A
1500A
A-405
A-406
A-408
A-407
HFEA
C G I
B
145'-4"
1' -7
'-5
'-7
'-5
'-7
'-5
'-7
1'
-7
9'-0"
A-202
A-201
A-202
A-201P41
P41
P41C
P41
P41
P41
P41B
P41
P41B
P41
P41
P41
P21
P21 P61
P61P21A
P81
P81
P81
P81
P21
P21
P21A
P21A
P21A
P21A
P21
P21
P41 P41
P41
P21A
P21A P41D
P21
6'-4"
7'-8 1/8"
P22A
D
COMM
P21
P02 P02
P02
P02
P21 P21
P21
P21A
P21A
P21A
P02 P02
P61
'-5
6'
-0
5' -0
/4
1'-0" 20'-5" 8'-7"
'-8
1'-4 1/2"
5'-1 1/4"
7'-6 1/4"10'-6 1/2" 7 1/2"
7'-4 1/2" 17'-4"
9' -1
1/
8" 3'
-7
/4
6' -0
1'
-0
12'-8" 6'-7 1/2"
1'-7 1/4"
'-9
3'-3 3/4"
5'-7"
3' -4
8'
-3
/2
6' -1
'-2
8'
-9
/4
4'-10" 8'-9 3/4" 6'-1 1/2" 5'-6"
1'-0 5/8"
A-403
9.01
9.01
1503C
P41D
P41D
P21A
8.01
4'-0 5/8"
P12A
A-302
A-303
A-304
A-301
A-30110.02
10.02
10.03
10.07
10.05
10.04
3'-1" 4'-1 1/2" 5'-8 1/2" 17'-9" 42'-0" 42'-0" 17'-9" 9'-10"
3'-1" 3'-1" 5'-11"
9'-0" 9'-0"
163'-4"
4'-4"
1501AB
10.08 10.08
10.08
10.09
7' -6
P21A
5.01
A-405
A-412
5.01
LAUNDRY
1503A
A
11'-7" 11'-7"
AUDITORIUM
1400B
A-401
P02 10.08
A-506
A-506
A-506
A-506
A-506
7' -6
/2
A-406
A-507
A-507
P02 P01
P41
P41
P41
P41
P41
P41
P41
3.04 3.04
A-531
A-531
A-531
8.02
VERIFY
15'-5"
P41D
P21AP41D
P41P41B
P41B
P52A
P41
10.07
9.04 9.05
9.04 9.04
9.04
9.049.04 9.04
1'-9 7/8"
/4
8.03
10.14 10.14
10.14
A. REFER TO SHEET G-005 FOR ABBREVIATIONS.
B. REFER TO SHEET A-001 FOR GENERAL NOTES,
LEGENDS AND SYMBOLS.
C. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, FIRE
PROTECTION, TELECOM AND ELECTRICAL DRAWINGS
AND SPECIFICATIONS FOR ADDITIONAL WORK AND
COORDINATE EXTENT WITH RESPECTIVE TRADES.
D. ALL DIMENSIONS ARE TO FINISH FACE OF NEW GWB,
MASONRY OR CONCRETE INTERIOR PARTITIONS,
COLUMN CENTERLINE, OR FACE OF ROUGH OPENING
UNO.
E. PROVIDE SOLID FRT WD BLOCKING AT PARTITIONS AS
REQUIRED TO ACCOMMODATE INSTALLATION OF
CASEWORK, LOCKERS, GRAB BARS, AV EQUIPMENT,
SIGNAGE AND ALL SCHEDULED EQUIPMENT AND
ACCESSORIES.
F. FIRE RATED PARTITIONS ARE NOTED BY PARTITION
TYPE. REFER TO LIFE SAFETY PLANS FOR REQUIRED
FIRE RATED AND/OR SMOKE PARTITION LOCATIONS.
G. ALL NEW INTERIOR PARTITIONS SHALL BE TYPE P22
UNO. REFER TO SHEET A-601 FOR PARTITION TYPES.
H. SEE SHEET A-100 FOR SECURE BOUNDARY LOCATIONS.
I. SEE IN-SERIES PLAN SHEETS FOR EXTENTS OF RAISED
ACCESS FLOORING.
J. PROVIDE FACE OF NON-STC RATED GWB COLUMN
WRAPS AT 1'-0" FROM COLUMN CENTER LINE, TYP UNO.
PROVIDE FACE OF STC-RATED GWB COLUMN WRAPS
AT 1'-2" FROM COLUMN CENTER LINE, TYP UNO. SEE
INTERIOR DETAILS SHEETS.
GENERAL NOTES THIS SHEET:
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
FY
0, P
N
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
AE
C
O M
S
ER
VI
C
ES
, I
N C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
/2
4/
7 8 9 10
B
C
D
E
F
G
TM
J
N
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
-W
2P M
R
A-101
FI
R
ST
F
LO
O
R P
LA
N
C
LB
C
LB
R M
G
FY
PN
4A
-1
.d w g
READY TO ADVERTISE
1/8" = 1'-0"
FIRST FLOOR PLAN
SHEET KEYNOTES:
3.04 12" X 24" PRECAST CONCRETE SPLASHBLOCK
5.01 STEEL BOLT DOWN PIPE BOLLARD, 4-1/2" x 36"
8.01 CENTER OVERHEAD COILING DOOR ON THE AISLE
BETWEEN LOCKERS. COORDINATE WITH FINAL
LOCKER LAYOUT.
8.02 LOUVER L1 ABOVE DOOR. SEE SHEET A-611.
8.03 CENTER DOOR IN ROOM.
9.01 CONTINUE P21 WALL TYPE OVER CONC TOP OF
ARMS ROOM. ALIGN FACE OF GWB WITH ADJACENT
P21 WALL AND LAMINATED GWB AS PART OF P81
WALL TYPE BELOW.
9.04 GWB CONTROL JOINT FROM TOP OF DOOR OPENING
TO STRUCTURE ABOVE. ALIGN WITH EDGE OF
OPENING.
9.05 GWB CONTROL JOINT. ALIGN WITH GWB CONTROL
JOINT ACROSS CORRIDOR.
10.02 30.5"W X 42"H RECESSED CELL PHONE LOCKER. SEE
5/A-411 FOR ELEVATION.
10.03 36"X36"X96" DOUBLE TIER WIRE MESH EQUIPMENT
LOCKER, TYP OF 54
10.04 36" DEEP x 87" HIGH BULK STORAGE RACKS WITH
THREE ADJUSTABLE STEEL WIRE DECKING SHELVES
10.05 DASHED LINES INDICATE AREAS DEDICATED FOR
PALLET STORAGE
10.07 18"X60" HDPE LOCKER ROOM PEDESTAL BENCH -
ANCHOR TO FLOOR
10.08 SEMI-RECESSED FIRE EXTINGUISHER CABINET
10.09 WALL MOUNTED FIRE EXTINGUISHER
10.14 PROVIDE 4'-0" HIGH WALL PROTECTION AND CORNER
GUARDS ON ALL WALLS IN CORRIDOR 1500 AND
VESTIBULE 1500A. COLOR OF WALL PROTECTION,
CORNER GUARDS AND TRIM TO MATCH WALL
COLOR.
MA
RK
DE
SC
RI
PT
IO
N
DA
TE
RE
VI
SE
D
IN
A C C
OR
DA
N C E
W
IT
H
AM
EN
DM
EN
T
M
AR
2 0
1 1
| Sheets |
| A-101 - FIRST FLOOR PLAN |