FY20PN92594A-102.pdf

PDF 191 KB Posted

Attached to
PN 92594 SOF Operations Support Facility Federal contract opportunity
Solicitation number
W912PM
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

This solicitation requests proposals for the construction of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes construction of a 36,000 square foot facility to sensitive compartmented information standards. It will include office, training, medical, and operations areas along with necessary supporting facilities such as parking, utilities, and site improvements. Sustainability, energy efficiency, and security requirements are also specified. Proposals are due under Solicitation Number W912PM. The resultant contract will be a firm-fixed price agreement awarded by the Department of the Army Corps of Engineers Engineering District Wilmington. The period of performance is 540 calendar days.

View the file

Other files for this federal contract opportunity

Other files attached to PN 92594 SOF Operations Support Facility, newest first.
File Type Posted
PN92594_W912PM19R00210005.pdf PDF
FY20PN92594IF601.pdf PDF
FY20PN92594A-602.pdf PDF
FY20PN92594A-412.pdf PDF
FY20PN92594A-601.pdf PDF
PN92594_0003_Technical Summary of Changes.pdf PDF
PN92594_W912PM19R00210003.pdf PDF
03 30 00.00 10.pdf PDF
01 45 35.pdf PDF
PN92594_0002_Technical Summary of Changes.pdf PDF
FY20PN92594M-602.pdf PDF
PN92594_W912PM19R00210002.pdf PDF
FY20PN92594MP102.pdf PDF
FY20PN92594T101.pdf PDF
10 44 16.pdf PDF
FY20PN92594T102.pdf PDF
FY20PN92594M-501.pdf PDF
FY20PN92594M-503.pdf PDF
08 33 23.pdf PDF
03 45 00.pdf PDF
FY20PN92594IN101.pdf PDF
FY20PN92594TA501.pdf PDF
FY20PN92594IN601.pdf PDF
FY20PN92594A-101.pdf PDF
FY20PN92594A-410.pdf PDF
FY20PN92594T504.pdf PDF
01 33 00.00 37 Submittal Register.pdf PDF
PN 92594_RTA SPECS_VOL 01 (Amend0001).pdf PDF
PN92594_W912PM19R00210001.pdf PDF
PN 92594_RTA SPECS_VOL 05 (Amend0001).pdf PDF
Technical Summary of Changes to W912PM19R0021-0001_pn92594.pdf PDF
Site Visit Sign In Roster 92594 .pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
Show all 50

PN 92594 SOF Operations Support Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-301

4'-4" 16'-0" 122'-8" 16'-0"

'-5

'-7

'-7

'-7

STAIR 1

PRINT/COPY

ELEC

COMM

WOMEN

BREAK ROOM

STAIR 2

OFFICE

OFFICE

OFFICE

TRAINING

OPEN OFFICE

OPEN OFFICE

MEN

VEST

2300A

JANITOR

TRAINING

OFFICE

COMM

OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

OPEN OFFICE

PRINT/COPY

VEST

2300B

OPEN OFFICE

OPEN OFFICE

TRAINING

OPEN OFFICE

TRAINING

OFFICE

OFFICE

STOR

VEST

250A

A-301

OPEN OFFICE

0A

2002B

A

B

A

A

C

D

09 23

A

B

CORRIDOR

HFEA

C G I

B

9'-0" 29'-1" 87'-2" 29'-1"

A-405

P41C

P41D

P41B

P41B

P41 P41B P41B

P41B

P41P41

P41

P41

P41

P41

P52B

P52B P52B

P52B

P41A

P41A

P41

A-202

A-201

A-201

A-202

OPEN OFFICE

P21

P41 P22

P41

P41 P41C

P41D

P41D

P21A

P21

P22A

P22A

D

P41P41

P22A

P02

P02

P02

P02

P12 P02

P12AP12A

P02

P02

P02

P02

P02 P02 P02 P02 P02 P02

P02

P02

4' -2

/8

9'

-1

3/ 4"

'-8

/8

1' -0

'-8

/2

6' -5

/8

'-1

/2

'-1

/2

2'-3 1/8"

2'-4" 10'-7 7/8" 6'-2 1/2"

2'-0 1/4"

1' -0

'-1

/8

6' -3

/4

10'-8 3/4" 2'-10 3/4"

5'-2 3/8"

1' -0

1'-9"

6' -0

9' -1

1/

8" 1'

-8

/8

3'-10 1/2" 10'-6 1/2"

P22

P22 P41 P41

1'-0" 12'-4 3/8" 11'-7" 11'-7"

'-4

A-403

P12C P12C

1'-9"

A-410

P41A

P41A

P41 P41

P41

1' -3

/4

6'-1 1/4"

ELEC CLOSET

2305A

2'-1 3/8"

3' -0

5'-6"

A-411 2

A-302

A-303

A-304

R 177'-8"

A-301

A-301

P22

P41D

163'-4"

4'-4"

7'-9" 4'-1 1/2" 5'-8 1/2" 17'-9" 42'-0" 42'-0" 17'-9" 9'-10" 6'-2"

1' -7

'-7

'-5

'-7

'-5

'-7

'-5

1'

-7

7' -1

1/

4"

2' -6

7'

-0

/4

P12

10.08

10.08 10.08 8'-1 3/8" 5'-6"

13'-5"

3' -0

A-405

R 180'-0"

6.11 6.11

TO

R

AD

C

T R

D

IM

. N

TS

'-6

/4

RADIUS CENTER -

ALIGNED WITH

COL LINE E

A-401

2'-11"

FACP CLOSET

2305B

B

'-9

" 1'-2" 6'-0 1/2"

2' -0

5' -0

6'-0 1/2" 8'-11"

2' -0

P41

P52AP52A

P41D 10.08

10.08

A-507

A-507

A-507

A-507

A-411

A-507

A-532

A-532

A-532

A-532

A-532

A-532

A-532

A-532

R 175'-11"

ELEVATOR

A-411

A-411

1' -7

/2

A-531

1'-0"

P52

A-531

A-507

OH

P21A

27.03 27.04

9.04 9.04 9.06

3' -6

A-507

OH

8.03

8.03

5' -0

A-532

29'-6 3/4" 29'-6 3/4"

10.08

A-402

9.07

A. REFER TO SHEET G-005 FOR ABBREVIATIONS.

B. REFER TO SHEET A-001 FOR GENERAL NOTES,

LEGENDS AND SYMBOLS.

C. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, FIRE

PROTECTION, TELECOM AND ELECTRICAL DRAWINGS

AND SPECIFICATIONS FOR ADDITIONAL WORK AND

COORDINATE EXTENT WITH RESPECTIVE TRADES.

D. ALL DIMENSIONS ARE TO FINISH FACE OF NEW GWB,

MASONRY OR CONCRETE INTERIOR PARTITIONS,

COLUMN CENTERLINE, OR FACE OF ROUGH OPENING

UNO.

E. PROVIDE SOLID FRT WD BLOCKING AT PARTITIONS AS

REQUIRED TO ACCOMMODATE INSTALLATION OF

CASEWORK, LOCKERS, GRAB BARS, AV EQUIPMENT,

SIGNAGE AND ALL SCHEDULED EQUIPMENT AND

ACCESSORIES.

F. FIRE RATED PARTITIONS ARE NOTED BY PARTITION

TYPE. REFER TO LIFE SAFETY PLANS FOR REQUIRED

FIRE RATED AND/OR SMOKE PARTITION LOCATIONS.

G. ALL NEW INTERIOR PARTITIONS SHALL BE TYPE P22

UNO. REFER TO SHEET A-601 FOR PARTITION TYPES.

H. SEE SHEET A-100 FOR SECURE BOUNDARY LOCATIONS.

I. SEE IN-SERIES PLAN SHEETS FOR EXTENTS OF RAISED

ACCESS FLOORING.

J. PROVIDE FACE OF NON-STC RATED GWB COLUMN

WRAPS AT 1'-0" FROM COLUMN CENTER LINE, TYP UNO.

PROVIDE FACE OF STC-RATED GWB COLUMN WRAPS

AT 1'-2" FROM COLUMN CENTER LINE, TYP UNO. SEE

INTERIOR DETAILS SHEETS.

GENERAL NOTES THIS SHEET:

8' 4' 0 8' 16' 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E:

1 2 3 4 5

A

GRAPHIC SCALES

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

AR

O

LI

N

A

AE

C

O M

S

ER

VI

C

ES

, I

N C

S J

EF

FE

R

SO

N S

T

ST

E

R

O

AN

O

KE

V A

/2

4/

7 8 9 10

B

C

D

E

F

G

TM

J

N

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

-W

2P M

R

A-102

SE

C

O N

D F

LO

O

R P

LA

N

C

LB

C

LB

R M

G

FY

PN

4A

-1

.d w g

READY TO ADVERTISE

1/8" = 1'-0"

SECOND FLOOR PLAN OVERALL

SHEET KEYNOTES:

6.11 BUILT-IN PERSONAL STORAGE LOCKERS - 15

LOCKERS, 15"W X 15"H X 15"D, 5 WIDE X 3 HIGH,

PLAM-2

8.03 CENTER DOOR IN ROOM.

9.04 GWB CONTROL JOINT FROM TOP OF DOOR

OPENING TO STRUCTURE ABOVE. ALIGN WITH

EDGE OF OPENING.

9.06 GWB CONTROL JOINT. ALIGN WITH CORNER OF

ALCOVE ACROSS CORRIDOR.

9.07 1 HOUR FIRE RATED HORIZONTAL SHAFTWALL

CONSISTING OF 4" C-H STUDS WITH 1" LINER

PANEL AND 1 LAYER 5/8" TYPE 'X' GYPSUM BOARD

IN CONCRETE FLOOR OPENING. SEE PARTITION

TYPE NOTE 'N' ON SHEET A-601. INSTALL TOP AT

16'-0" ELEVATION, ALIGNED WITH ADJACENT

CONCRETE FLOOR SLAB.

10.08 SEMI-RECESSED FIRE EXTINGUISHER CABINET

27.03 GFGI KNOWLEDGE WALL AND FRAME. SEE AV

DRAWINGS.

27.04 GFGI AV CREDENZAS

MA

RK

DE

SC

RI

PT

IO

N

DA

TE

RE

VI

SE

D

IN

A C C

OR

DA

N C E

W

IT

H

AM

EN

DM

EN

T

M

AR

2 0

Sheets
A-102 - SECOND FLOOR PLAN

File details come from the government source that posted it. Updated .