FY20PN92594MP102.pdf
PDF 346 KB Posted
- Attached to
- PN 92594 SOF Operations Support Facility Federal contract opportunity
- Solicitation number
- W912PM
About this file
This document contains a Request for Proposal (RFP) soliciting construction and design services for an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes construction of an approximately 36,000 square foot facility to sensitive compartmented information standards. It requires command, life support, office, training, medical, and operations areas. Ancillary requirements include information systems, mass notification, cybersecurity, fire protection, elevator, backup power, raised floor, redundant chiller, security systems, furnishings, and site improvements. Sustainability and energy measures must be incorporated. The period of performance is 540 calendar days. The resultant contract will be firm-fixed price awarded by the Department of the Army Corps of Engineers Engineering District Wilmington.
View the file
Other files for this federal contract opportunity
Show all 50
PN 92594 SOF Operations Support Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STAIR 1
PRINT/COPY
ELEC
COMM
WOMEN
BREAK ROOM
STAIR 2
OFFICE
OFFICE
OFFICE
TRAINING
OPEN OFFICE
OPEN OFFICE
MEN
VEST
2300A
JANITOR
TRAINING
OFFICE
COMM
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
OPEN OFFICE
PRINT/COPY
VEST
2300B
OPEN OFFICE
OPEN OFFICE
TRAINING
OPEN OFFICE
TRAINING
OFFICE
OFFICE
STOR
VEST
250A
HFEDA
C G I
B
M-302
TU-23
TU-24
TU-20
TU-21
TU-22
TU-25
TU-15
TU-14
TU-16
TU-17
TU-18
TU-13
TU-12
TU-11
TU-10
TU-08
TU-06
TU-19
TU-07
TU-09
TU-03
TU-51
TU-05TU-04
TU-01
3/4" HWS
3/4" HWR
3/4" HWS
3/4" HWR
1" HWR
1" HWS3/4" HWR
3/4" HWS
1 1/2" HWR
1 1/2" HWS
3/4" HWR
3/4" HWS
3/4" HWS
3/4" HWR
1" HWR
1" HWS
1" HWS
1" HWR
1" HWR
1" HWS
OPEN OFFICE
TU-52
TU-02
T
T
T T T
T
T
T T
T T
T T
T T
T
T
T
T
T
T
T
T
T T
SS-04a
SS-04b
SS-05a
SS-05b
SS-05c
6" CHWS
6" CHWR
2" HWS
2" HWR
1" HWS
1" HWR
C H
W R
C H
W S
M-301
M-302
M-302
M-303
SS-08b
SS-08a
1" D 1" D
1" D
3/4" D
3/4" D
TU-18
TU-17
TU-16
TU-15
TU-14
TU-13
TU-12
TU-11
TU-07
TU-10 TU-08 TU-06
TU-01
TU-25
TU-21
TU-22
TU-20
TU-23
TU-24
TU-19
TU-09
TU-52
TU-51
TU-02
T
TU-03
T
TU-04
T
TU-05
3/4" HWR
3/4" HWS
RL
RS
RL
RS
RL
RS
1" D
R S
R S
R L
R L
RL
RS
RL
RS
RL
RS
SS-08
T
SS-05
3/4" D
RS
RL
RS
RL
RL
RS
RL
RS 1" D
ELEVATOR
CORRIDOR
M-301
3/4" HWR
3/4" HWS
3/4" HWR
3/4" HWS
23.021
23.02123.021
23.021
23.011
23.013 23.014
23.015
23.016
23.017 23.018
23.019
23.020
SS-04c
1" D
1" D
3/4" D
RL
RS
RL
RS
RL
RS
23.02123.021
23.021
23.021
3/4" HWR
3/4" HWS
RS
RL
23.021
23.021
23.021
23.021
23.021
23.02123.021
23.021
23.021
23.021
1" HWR
1" HWS
DP
C
C
23.012
23.04423.044
23.058
T
SS-04
8' 4' 0 8' 16'
1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A S
O F
O P
E R
A T
IO
N
S F
A C
IL
IT
Y F
Y
P
N
W
IL
M
IN
G T
O N
D
IS
T
R
IC
T W
IL
M
IN
G
T O
N N
O R
T H
C A
R O
L
IN
A
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
/2
/1
7 8 9 10
B
C
D
E
F
G
T M
J
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
-W P
M R
MP102
S E
C O
N D
F L O
O R
P
IP
IN
G
P L A
N
D P
A
T B
M
C L W
F Y
P
N M
P .d w g
READY TO ADVERTISE
1/8" = 1'-0"
SECOND FLOOR PIPING PLAN
⎔ SHEET KEYNOTES:
23.011 6" CHWS UP FROM FIRST FLOOR THROUGH
SECURE BOUNDARY AT UTILITY CHASE
WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.012 6" CHWR DOWN TO FIRST FLOOR THROUGH
SECURE BOUNDARY AT UTILITY CHASE
WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.013 2 1/2" HWS UP FROM FIRST FLOOR THROUGH
SECURE BOUNDARY AT UTILITY CHASE
WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.014 2 1/2" HWR DOWN TO FIRST FLOOR THROUGH
SECURE BOUNDARY AT UTILITY CHASE
WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.015 6" CHWS UP TO AHU-01 THROUGH SECURE
BOUNDARY AT UTILITY CHASE WALL.
PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.016 6" CHWR DOWN FROM AHU-01 THROUGH
SECURE BOUNDARY AT UTILITY CHASE
WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.017 1 1/2" HWS UP TO AHU-01 THROUGH SECURE
BOUNDARY AT UTILITY CHASE WALL.
PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.018 1 1/2" HWR DOWN FROM AHU-01 THROUGH
SECURE BOUNDARY AT UTILITY CHASE
WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.019 1" HWS THROUGH SECURE BOUNDARY AT
SWA WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.020 1" HWR THROUGH SECURE BOUNDARY AT
SWA WALL. PROVIDE DIELECTRIC BREAK AT
PENETRATION.
23.021 GROUND REFRIGERANT PIPING
PENETRATIONS THROUGH ROOF WITH NO. 4
WIRE TO THE BUILDING GROUND. GROUND
REFRIGERANT LINE WITHIN 6" OF SECURE
BOUNDARY.
23.044 3/4" HWS&R BRANCH UP TO UH-03.
23.058 TERMINATE CONDENSATE DRAIN 1" ABV
FLOOD LEVEL OF SINK.
GENERAL NOTES THIS SHEET (PIPING)
A. REFER TO SHEET M-001 FOR MECHANICAL LEGEND AND
GENERAL NOTES.
B. CONTRACTOR SHALL ENSURE THE BOTTOM OF THE VAV
BOXES ARE A MINIMUM OF 6” ABOVE CEILING GRID IN ORDER
TO PROVIDE THE REQUIRED SERVICE CLEARANCE, AND
MAINTAIN SERVICE CLEARANCE ON CONTROL SIDE OF VAV
BOX, AS INDICATED.
C. ALL PIPING RUNOUTS TO HYDRONIC EQUIPMENT SHALL BE ¾”
UNLESS OTHERWISE INDICATED.
D. ROUTE CONDENSATE PIPING FROM DUCTLESS SPLIT SYSTEMS
TO NEAREST FLOOR DRAINS.
E. SIZE ALL REFRIGERANT PIPING PER MANUFACTURER’S
RECOMMENDATIONS.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
M A
R
| Sheets |
| M-501 - MECHANICAL DETAILS |
| M-503 - MECHANICAL DETAILS |
| M-602 - MECHANICAL SCHEDULES |
| MP102 - SECOND FLOOR PIPING PLAN |
File details come from the government source that posted it. Updated .