FY20PN92594M-503.pdf
PDF 275 KB Posted
- Attached to
- PN 92594 SOF Operations Support Facility Federal contract opportunity
- Solicitation number
- W912PM
About this file
This document includes a federal contract solicitation and related mechanical drawings and details. The solicitation seeks construction and design services for an approximately 36,000 square foot Operations Support Facility at Fort Bragg, North Carolina to sensitive compartmented information standards. Scope of work encompasses construction of the facility including command, life support, office, training, and operations areas along with supporting mechanical, electrical, plumbing, and security systems. Sustainability measures and accommodations for individuals with disabilities are required. The period of performance is 540 calendar days. The resultant contract will be firm-fixed price awarded by the Department of the Army Corps of Engineers Wilmington District.
View the file
Other files for this federal contract opportunity
Show all 50
PN 92594 SOF Operations Support Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"D"
MIN
6D
A
IR
F L O
W
CONICAL TEE
DUCT
MAIN
NOTE B
TERMINAL UNIT,
NOTE A
TRANSITION
DUCT SIZE AS
INDICATED
NOTES:
A.
B.
C.
INSTALL UNIT TO HAVE FULL ACCESS FOR SERVICE. DO NOT LOCATE
ABOVE LIGHTS. INSTALL FREE OF OBSTRUCTIONS WITH ACCESS TO
CONTROL PANEL.
RUNOUT SIZE AS NOTED ON FLOOR PLANS OR SCHEDULE.
PIPING CONNECTIONS TO REHEAT COILS AND ALL DUCTWORK SHALL
BE IN ACCORDANCE WITH THE APPLICABLE DETAILS.
M
IN
8"x8"x3/8" STEEL
PLATE
WELD PLATE
TO PIPE
SECURE TO ROOF SLAB WITH (4)
3/8" DIA. EXPANSION BOLTS OR
WELD TO STEEL DECK
CONCRETE ROOF SLAB
OR STEEL ROOF DECK
ROOF SYSTEM
INSULATION
AND MEMBRANE
PRE-MOULDED FLEXIBLE
PIPE COUNTER FLASHING
CLAMPING RING
ROOF
SURFACE
WELD PIPE SADDLE
SUPPORT TO PIPE.
PROVIDE WATER
TIGHT CONNECTION
HIGH COMPRESSIVE
STRENGTH INSULATION
INSERT UNDER SHIELD
PIPE AND
INSULATION
INSULATION
PROTECTION SHIELD
SEALANT
2" STEEL PIPE
2-1/2" STEEL PIPE
PROVIDE ALUMINUM
JACKET
DETAIL NOTES:
1. PROVIDE RESTRAINING CLAMPS 8'-0" O.C.
DRAW THRU
BLOW THRU
2" PLUS X
1" MINIMUM
X
2X
UNIT TYPE A B
WHERE X = STATIC PRESSURE IN PAN
A
B 1" [25mm]
DRAIN PAN
DIELECTRIC
FITTING
SPLASH BLOCK
CLEAN OUT
PITCH DOWN
TOWARD DRAIN
DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS
THE NIPPLE ON THE DRAIN PAN. PIPING SHALL BE
RIGID COPPER TYPE L
NOTES:
1. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS ARE TO BE
CONNECTED.
DIAL TYPE PRESSURE
GAUGE (0-100 PSIG)
CHECK VALVE
BALL VALVE (TYP)
FLOW
FLANGE
HORIZONTAL
INLINE PUMP
STRAINER
CONCRETE FLOOR
PIPE SUPPORT (TYP)
NOTES:
A.
B.
C.
D.
E.
F.
G.
UL CLASSIFIED FIRESTOPPING SEALANT AND MINERAL WOOL BACKUP.
TERMINATE INSULATION AT WALL OR ROOF PENETRATION. INSULATION SHALL OVERLAP
CONTINUOUS SLEEVE.
CONDUCTIVE TAPE WITH CONDUCTIVE ADHESIVE SHALL OVERLAP PENETRATION PLATE AND
TECHNICAL SECURITY BOUNDARY BY AT LEAST 2" ON ALL SIDES.
FOR REFRIGERANT PIPING ONLY. GROUND PIPING PENETRATIONS THROUGH ROOF WITH NO. 4
WIRE TO THE BUILDING GROUND. GROUND PIPING WITHIN 6" OF SECURE BOUNDARY.
TERMINATE INSULATION AT WALL OR ROOF PENETRATION. INSULATION SHALL OVERLAP
CONTINUOUS SLEEVE AND PENETRATION PLATE. EXTEND INSULATION AT LEAST 2" PAST END
OF PENETRATION PLATE ON ALL SIDES.
FOR HYDRONIC AND DOMESTIC WATER PIPING ONLY. NON-FERROUS COUPLING DI-ELECTRIC
BREAK (6" MAX).
WALL PENETRATIONS ARE FOR WALL TYPES P41 AND P52A. REFER TO ARCHITECTURAL
DRAWING A-601.
SLEEVE
WALL OR ROOF
NOTE A (TYP)
INSULATION (WHERE
REQUIRED). NOTE B
NOTE D
1/8"
1/8"
SWA OR SAP BOUNDARY
(TYP)
CONTINUOUS
CIRCUMFERENTIAL
WELDS
UNBROKEN SLEEVE,
LENGTH: 12"
PENETRATION PLATE
BRONZE SUPPORT CLAMP (TYP)
BRONZE FASTENER (TYP)
CONDUCTIVE TAPE WITH CONDUCTIVE
ADHESIVE (NOTE C)
INSULATION (WHERE
REQUIRED). NOTE E
6" MIN
6" MINBONDING STRAP
NOTE F
STEEL FRAME
AIR DUCT
FILLET WELD 1/2" DIA.
STEEL BARS TO 1-1/4" x
1/4" BAR STEEL FRAME
SPOT WELD 1/2" DIA.
BARS AT EACH
INTERSECTION (TYP.)
1/2" DIA. STEEL
BARS 6" O.C.
EACH WAY (TYP.)
STEEL SCREWS. FRAME TO DUCT. SPOT WELD SCREW
HEAD TO FRAME OR USE 2" #10 PIN-IN HEXHEAD
TAMPER RESISTANT SCREWS (IN LIEU OF WELDING)
THERMOMETER
FLOW SWITCH
FLEXIBLE
CONNECTORS
TEST PLUGS
CHS
EVAPORATOR
CHR
DDC
TEMPERATURE
SENSOR TO ECC
PRESSURE
GAUGE
FS
TT TT
1/8"
1/8"
INSULATION
FLOOR
WALL OR
PIPE
EXPOSED)
NOTE:
SHALL BE FIRESTOPPED WITH A UL-CLASSIFIED SYSTEM.
PIPE PENETRATIONS IN FIRE-RATED CONSTRUCTION
THIS DETAIL IS FOR NONFIRE-RATED CONSTRUCTION.
(WHERE
ESCUTCHEON
PACKING
REQUIRED)
(WHERE
JOINT BACKING
SEALANT WITH
SLEEVE
ALUMINUM
JACKET
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A S
O F
O P
E R
A T
IO
N
S F
A C
IL
IT
Y F
Y
P
N
W
IL
M
IN
G T
O N
D
IS
T
R
IC
T W
IL
M
IN
G
T O
N N
O R
T H
C A
R O
L
IN
A
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
/2
/1
7 8 9 10
B
C
D
E
F
G
T M
J
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
-W P
M R
M-503
M E
C H
A N
IC
A
L D
E T
A
IL
S
D P
A
T B
M
C L W
F Y
P
N M
-5 .d w g
READY TO ADVERTISE
NO SCALEM-503
1 TYPICAL VAV BOX INSTALLATION DETAIL
NO SCALEM-503
3 TYPICAL PIPE SUPPORT - ROOF DETAIL
NO SCALEM-503
4 TYPICAL CONDENSATE DRAIN TRAP DETAIL
NO SCALEM-503
5 TYPICAL VERTICAL IN-LINE PUMP DETAIL
NO SCALEM-503
TYPICAL SECURE PIPING PENETRATION
DETAIL
NO SCALEM-503
7 TYPICAL SECURITY MANBARS DETAIL
NO SCALEM-503
AIR COOLED CHILLER PIPE CONNECTION
DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
M A
R
NO SCALEM-503
TYPICAL PIPE PENETRATIONS
THRU WALLS AND FLOORS
| Sheets |
| M-501 - MECHANICAL DETAILS |
| M-503 - MECHANICAL DETAILS |
| M-602 - MECHANICAL SCHEDULES |
| MP102 - SECOND FLOOR PIPING PLAN |