FY20PN92594M-501.pdf
PDF 266 KB Posted
- Attached to
- PN 92594 SOF Operations Support Facility Federal contract opportunity
- Solicitation number
- W912PM
About this file
This solicitation requests proposals for the construction and design of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes construction of an approximately 36,000 square foot facility to sensitive compartmented information standards. It will include office, training, medical, operations, and support spaces. Information systems, fire protection and detection systems, emergency power, and an energy monitoring control system will be provided. Sustainability, antiterrorism/force protection measures, and Americans with Disabilities Act compliance are required. The period of performance is 540 calendar days. The resultant contract will be firm-fixed price. The soliciting agency is the Department of the Army Corps of Engineers Engineering District Wilmington.
View the file
Other files for this federal contract opportunity
Show all 50
PN 92594 SOF Operations Support Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTES:
1. "D" IS THROAT DIA OR SIDE DIM. OF SQUARE CONN.
2. MIN LENGTH OF STRAIGHT DUCT ABOVE CD IS "D".
3. ABOVE DETAILS ARE REPRESENTATIVE OF STANDARD DUCT CONNECTIONS,
ONLY. THESE DETAILS ARE NOT INTENDED TO SHOW ALL POSSIBLE DUCT
CONNECTIONS.
MIN
"D""D"
AIR FLOW
CEILING
DIFFUSER
END
OF
DUCT
MIN
"D" "D"
4"
MIN
45°
VOLUME
DAMPERCEILING
EXHAUST OR
RETURN REGISTER
M
IN
R=1.5D
CEILING
DIFFUSER
FLEXIBLE DUCT
WHERE INDICATED
NOTE 2
SPIN-IN FITTING
W/ BUTTERFLY
DAMPER
SUPPLY
DUCT
CLG
M
IN
MIN
"D"
4"
MIN
45°
CEILING DIFFUSER
NOTE 2
VOLUME
DAMPER
CLG
VD
VD
BALANCING DAMPER
MAIN DUCT
W
L= 1/4"W, 4" MIN.
PLAN
ELEVATION
NOTES:
1. TRANSITION AS REQUIRED WHEN BRANCH OR RUNOUT DUCT DEPTH IS
SAME OR LARGER THAN THE MAIN DUCT
45° L
1"
MIN
1"
MIN
VD
DUCT OPENING
AIR TIGHT GASKET
TO RUN AROUND EDGE
OF ACCESS PANEL
COIL/DAMPER
AIRFLOWAIRFLOW
PROVIDE VISUAL PORTS
AT ALL LOCATIONS
EXCEPT HEATING COILS
ACCESS PANEL SIZE SCHEDULE
DUCT SIZE
6" TO 15"
15" TO 21"
21" AND ABOVE
ACCESS PANEL SIZE
10" W x (DUCT DEPTH - 2")D
12" W x (DUCT DEPTH - 2")D
18" W x (DUCT DEPTH - 2")D
ALL OTHER ACCESS PANELS TO BE A MINIMUM OF 15" x 15" WHERE DUCT SIZE ALLOWS. USE FOR CAM LATCHES ON PANELS LARGER THAN 15" x 15"
SIZE.
HINGE
TWO COATS OF VAPOR
BARRIER COATING WITH
GLASS CLOTH EMBEDDED
BETWEEN COATS
(TYP)
EXTERNAL INSULATION
ALL AROUND,
(TYP BOTH SIDES)
ADHESIVE
(TYP)
MIN. 14 GAGE STEEL
WALL SLEEVE
PROVIDE A MIN. OF 1/8"
PER FOOT CLEARANCE
BASED ON THE WIDTH
AND HEIGHT OF THE
DAMPER
1 1/2"x1 1/2"x10
GAGE RETAINING
ANGLES. ANGLES
MUST LAP
STRUCTURAL
OPENING 1" MIN.
AND COVER
CORNERS OF
OPENING
(TYP)
ACCESS
DOOR
BREAKAWAY SLIP
JOINT, DUCT TO
SLEEVE
(TYP)
SLEEVE 6" MAX.
ON ALL SIDES
(TYP)
FIRE DAMPER
ATTACHED TO WALL
SLEEVE WITH 1/4"
BOLTS OR WELDED
FUSIBLE
LINK
FLOOR
NOTES:
1. INSTALL FIRE DAMPER PER THE MANUFACTURER'S INSTALLATION
REQUIREMENTS TO MEET UL 555.
2. WHEN FULLY RETRACTED, FIRE DAMPER CURTAIN MUST NOT OBSTRUCT AIR
STREAM.
RECTANGULAR (SHOWN) OR
ROUND SUPPLY AIR DUCTWORK.
REFER TO PLANS FOR SIZE
DUCT SIZE 2" GREATER
THAN NOMINAL GRILLE SIZE
MANUAL VOLUME DAMPER
1" FLANGE (TYP)
DUCT MOUNTED SUPPLY
GRILLE. REFER TO
PLANS FOR DUCT SIZE
6" MIN
SUPPLY GRILLE
SECURE WITH SCREWS
6" MIN
DUCT SIZE 2" GREATER
THAN NOMINAL GRILLE SIZE
1" FLANGE
45° CLINCH
COLLAR TAP VD
V D
TYP
1/4" THREADED ROD
L3x3x1/4, 5" LONG
L5x3 1/2x5/16, LLH
LENGTH TO SUIT
DUCT SIZE AND
SUPPORT PIPE
SPACING
NOTE 1
L5x3 1/2x5/16, LLH
NOTE 1
MEMBRANE
ROOF INSULATION
PIPE 3" STD WELD
PL 3/8x6x6
DUCT
INSULATION
(WHERE
APPLICABLE)
LINING
(WHERE
APPLICABLE)
ROOF
SURFACE
WELD TO STEEL BEAMS.
COORDINATE WITH
STRUCTURAL.
STEEL BEAM. SEE
STRUCTURAL.
NOTES:
1. COORDINATE LENGTH AND PLACEMENT WITH STEEL ROOF BEAMS. SEE STRUCTURAL.
2. ALIGN PIPES WITH THE CENTERLINES OF ROOF BEAMS. BEAM SPAN VARIES.
3. PROVIDE L3x3x1/4 BRACING FROM TOP FLANGE TO ADJACENT BEAM BOTTOM FLANGE AT EACH
PIPE.
AS FLEXIBLE BLANKET INSULATION.
A. RIGID INSULATION SHALL BE SAME THICKNESS
NOTE:
(WHERE REQ'D)
INSULATION
FLEXIBLE BLANKET
NOTE A
RIGID INSULATION,
WALL
OPENING
PREPARED
SLEEVE OR
PACKING
SEALANT
DUCT
TO WALL)
IS EXPOSED (ATTACH
COLLAR WHERE DUCT
4" WIDE CLOSURE
B. TYPICAL FOR ALL WALL TYPES.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A S
O F
O P
E R
A T
IO
N
S F
A C
IL
IT
Y F
Y
P
N
W
IL
M
IN
G T
O N
D
IS
T
R
IC
T W
IL
M
IN
G
T O
N N
O R
T H
C A
R O
L
IN
A
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
/2
/1
7 8 9 10
B
C
D
E
F
G
T M
J
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
-W P
M R
M-501
M E
C H
A N
IC
A
L D
E T
A
IL
S
D P
A
T B
M
C L W
F Y
P
N M
-5 .d w g
READY TO ADVERTISE
NO SCALEM-501
1 TYPICAL DUCT CONNECTION DETAILS
NO SCALEM-501
2 TYPICAL DUCT TAKE-OFF DETAIL
NO SCALEM-501
4 TYPICAL DUCT ACCESS PANEL DETAIL
NO SCALEM-501
5 TYPICAL HORIZONTAL FIRE DAMPER DETAIL
NO SCALEM-501
3 TYPICAL EXPOSED SUPPLY GRILLE DETAIL
NO SCALEM-501
TYPICAL ROOF-MOUNTED DUCT SUPPORT
DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
M A
R
NO SCALEM-501
TYPICAL DUCT PENETRATION
THRU WALLS
| Sheets |
| M-501 - MECHANICAL DETAILS |
| M-503 - MECHANICAL DETAILS |
| M-602 - MECHANICAL SCHEDULES |
| MP102 - SECOND FLOOR PIPING PLAN |
File details come from the government source that posted it. Updated .