About this file

This solicitation requests proposals for the construction and design of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes construction of an approximately 36,000 square foot facility to sensitive compartmented information standards. It will include office, training, medical, operations, and support spaces. Information systems, fire protection and detection systems, emergency power, and an energy monitoring control system will be provided. Sustainability, antiterrorism/force protection measures, and Americans with Disabilities Act compliance are required. The period of performance is 540 calendar days. The resultant contract will be firm-fixed price. The soliciting agency is the Department of the Army Corps of Engineers Engineering District Wilmington.

View the file

Other files for this federal contract opportunity

Other files attached to PN 92594 SOF Operations Support Facility, newest first.
File Type Posted
PN92594_W912PM19R00210005.pdf PDF
FY20PN92594IF601.pdf PDF
FY20PN92594A-102.pdf PDF
FY20PN92594A-602.pdf PDF
FY20PN92594A-412.pdf PDF
FY20PN92594A-601.pdf PDF
PN92594_0003_Technical Summary of Changes.pdf PDF
PN92594_W912PM19R00210003.pdf PDF
03 30 00.00 10.pdf PDF
01 45 35.pdf PDF
PN92594_0002_Technical Summary of Changes.pdf PDF
FY20PN92594M-602.pdf PDF
PN92594_W912PM19R00210002.pdf PDF
FY20PN92594MP102.pdf PDF
FY20PN92594T101.pdf PDF
10 44 16.pdf PDF
FY20PN92594T102.pdf PDF
FY20PN92594M-503.pdf PDF
08 33 23.pdf PDF
03 45 00.pdf PDF
FY20PN92594IN101.pdf PDF
FY20PN92594TA501.pdf PDF
FY20PN92594IN601.pdf PDF
FY20PN92594A-101.pdf PDF
FY20PN92594A-410.pdf PDF
FY20PN92594T504.pdf PDF
01 33 00.00 37 Submittal Register.pdf PDF
PN 92594_RTA SPECS_VOL 01 (Amend0001).pdf PDF
PN92594_W912PM19R00210001.pdf PDF
PN 92594_RTA SPECS_VOL 05 (Amend0001).pdf PDF
Technical Summary of Changes to W912PM19R0021-0001_pn92594.pdf PDF
Site Visit Sign In Roster 92594 .pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
Show all 50

PN 92594 SOF Operations Support Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTES:

1. "D" IS THROAT DIA OR SIDE DIM. OF SQUARE CONN.

2. MIN LENGTH OF STRAIGHT DUCT ABOVE CD IS "D".

3. ABOVE DETAILS ARE REPRESENTATIVE OF STANDARD DUCT CONNECTIONS,

ONLY. THESE DETAILS ARE NOT INTENDED TO SHOW ALL POSSIBLE DUCT

CONNECTIONS.

MIN

"D""D"

AIR FLOW

CEILING

DIFFUSER

END

OF

DUCT

MIN

"D" "D"

4"

MIN

45°

VOLUME

DAMPERCEILING

EXHAUST OR

RETURN REGISTER

M

IN

R=1.5D

CEILING

DIFFUSER

FLEXIBLE DUCT

WHERE INDICATED

NOTE 2

SPIN-IN FITTING

W/ BUTTERFLY

DAMPER

SUPPLY

DUCT

CLG

M

IN

MIN

"D"

4"

MIN

45°

CEILING DIFFUSER

NOTE 2

VOLUME

DAMPER

CLG

VD

VD

BALANCING DAMPER

MAIN DUCT

W

L= 1/4"W, 4" MIN.

PLAN

ELEVATION

NOTES:

1. TRANSITION AS REQUIRED WHEN BRANCH OR RUNOUT DUCT DEPTH IS

SAME OR LARGER THAN THE MAIN DUCT

45° L

1"

MIN

1"

MIN

VD

DUCT OPENING

AIR TIGHT GASKET

TO RUN AROUND EDGE

OF ACCESS PANEL

COIL/DAMPER

AIRFLOWAIRFLOW

PROVIDE VISUAL PORTS

AT ALL LOCATIONS

EXCEPT HEATING COILS

ACCESS PANEL SIZE SCHEDULE

DUCT SIZE

6" TO 15"

15" TO 21"

21" AND ABOVE

ACCESS PANEL SIZE

10" W x (DUCT DEPTH - 2")D

12" W x (DUCT DEPTH - 2")D

18" W x (DUCT DEPTH - 2")D

ALL OTHER ACCESS PANELS TO BE A MINIMUM OF 15" x 15" WHERE DUCT SIZE ALLOWS. USE FOR CAM LATCHES ON PANELS LARGER THAN 15" x 15"

SIZE.

HINGE

TWO COATS OF VAPOR

BARRIER COATING WITH

GLASS CLOTH EMBEDDED

BETWEEN COATS

(TYP)

EXTERNAL INSULATION

ALL AROUND,

(TYP BOTH SIDES)

ADHESIVE

(TYP)

MIN. 14 GAGE STEEL

WALL SLEEVE

PROVIDE A MIN. OF 1/8"

PER FOOT CLEARANCE

BASED ON THE WIDTH

AND HEIGHT OF THE

DAMPER

1 1/2"x1 1/2"x10

GAGE RETAINING

ANGLES. ANGLES

MUST LAP

STRUCTURAL

OPENING 1" MIN.

AND COVER

CORNERS OF

OPENING

(TYP)

ACCESS

DOOR

BREAKAWAY SLIP

JOINT, DUCT TO

SLEEVE

(TYP)

SLEEVE 6" MAX.

ON ALL SIDES

(TYP)

FIRE DAMPER

ATTACHED TO WALL

SLEEVE WITH 1/4"

BOLTS OR WELDED

FUSIBLE

LINK

FLOOR

NOTES:

1. INSTALL FIRE DAMPER PER THE MANUFACTURER'S INSTALLATION

REQUIREMENTS TO MEET UL 555.

2. WHEN FULLY RETRACTED, FIRE DAMPER CURTAIN MUST NOT OBSTRUCT AIR

STREAM.

RECTANGULAR (SHOWN) OR

ROUND SUPPLY AIR DUCTWORK.

REFER TO PLANS FOR SIZE

DUCT SIZE 2" GREATER

THAN NOMINAL GRILLE SIZE

MANUAL VOLUME DAMPER

1" FLANGE (TYP)

DUCT MOUNTED SUPPLY

GRILLE. REFER TO

PLANS FOR DUCT SIZE

6" MIN

SUPPLY GRILLE

SECURE WITH SCREWS

6" MIN

DUCT SIZE 2" GREATER

THAN NOMINAL GRILLE SIZE

1" FLANGE

45° CLINCH

COLLAR TAP VD

V D

TYP

1/4" THREADED ROD

L3x3x1/4, 5" LONG

L5x3 1/2x5/16, LLH

LENGTH TO SUIT

DUCT SIZE AND

SUPPORT PIPE

SPACING

NOTE 1

L5x3 1/2x5/16, LLH

NOTE 1

MEMBRANE

ROOF INSULATION

PIPE 3" STD WELD

PL 3/8x6x6

DUCT

INSULATION

(WHERE

APPLICABLE)

LINING

(WHERE

APPLICABLE)

ROOF

SURFACE

WELD TO STEEL BEAMS.

COORDINATE WITH

STRUCTURAL.

STEEL BEAM. SEE

STRUCTURAL.

NOTES:

1. COORDINATE LENGTH AND PLACEMENT WITH STEEL ROOF BEAMS. SEE STRUCTURAL.

2. ALIGN PIPES WITH THE CENTERLINES OF ROOF BEAMS. BEAM SPAN VARIES.

3. PROVIDE L3x3x1/4 BRACING FROM TOP FLANGE TO ADJACENT BEAM BOTTOM FLANGE AT EACH

PIPE.

AS FLEXIBLE BLANKET INSULATION.

A. RIGID INSULATION SHALL BE SAME THICKNESS

NOTE:

(WHERE REQ'D)

INSULATION

FLEXIBLE BLANKET

NOTE A

RIGID INSULATION,

WALL

OPENING

PREPARED

SLEEVE OR

PACKING

SEALANT

DUCT

TO WALL)

IS EXPOSED (ATTACH

COLLAR WHERE DUCT

4" WIDE CLOSURE

B. TYPICAL FOR ALL WALL TYPES.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

1 2 3 4 5

A

F O

R T

B R

A G

G N

O R

T H

C A

R O

L

IN

A S

O F

O P

E R

A T

IO

N

S F

A C

IL

IT

Y F

Y

P

N

W

IL

M

IN

G T

O N

D

IS

T

R

IC

T W

IL

M

IN

G

T O

N N

O R

T H

C A

R O

L

IN

A

A E

C O

M S

E R

V

IC

E S

IN

C

S

J E

F F

E R

S O

N S

T S

T E

R O

A N

O K

E V

A

/2

/1

7 8 9 10

B

C

D

E

F

G

T M

J

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

-W P

M R

M-501

M E

C H

A N

IC

A

L D

E T

A

IL

S

D P

A

T B

M

C L W

F Y

P

N M

-5 .d w g

READY TO ADVERTISE

NO SCALEM-501

1 TYPICAL DUCT CONNECTION DETAILS

NO SCALEM-501

2 TYPICAL DUCT TAKE-OFF DETAIL

NO SCALEM-501

4 TYPICAL DUCT ACCESS PANEL DETAIL

NO SCALEM-501

5 TYPICAL HORIZONTAL FIRE DAMPER DETAIL

NO SCALEM-501

3 TYPICAL EXPOSED SUPPLY GRILLE DETAIL

NO SCALEM-501

TYPICAL ROOF-MOUNTED DUCT SUPPORT

DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D

IN

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

M A

R

NO SCALEM-501

TYPICAL DUCT PENETRATION

THRU WALLS

Sheets
M-501 - MECHANICAL DETAILS
M-503 - MECHANICAL DETAILS
M-602 - MECHANICAL SCHEDULES
MP102 - SECOND FLOOR PIPING PLAN

File details come from the government source that posted it. Updated .