FY20PN92594T101.pdf

PDF 401 KB Posted

Attached to
PN 92594 SOF Operations Support Facility Federal contract opportunity
Solicitation number
W912PM
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

This document summarizes a Request for Proposal for the construction and design of an Operations Support Facility at Fort Bragg, North Carolina. The scope of work includes building a 36,000 square foot facility to sensitive compartmented information standards, including a command section, life support area, private and open office areas, planning and training areas, security office, medical area, operations center, auditorium, and support spaces. The project also includes information systems, fire protection and detection systems, an elevator, backup power, raised floor, security systems, and site utilities. Comprehensive interior design services are required. The period of performance is 540 calendar days. The resultant contract will be firm-fixed price. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Wilmington.

View the file

Other files for this federal contract opportunity

Other files attached to PN 92594 SOF Operations Support Facility, newest first.
File Type Posted
PN92594_W912PM19R00210005.pdf PDF
PN92594_0005_Technical Summary of Changes.pdf PDF
PN 92594_RTA SPECS_VOL 01.pdf PDF
FY20PN92594A-602.pdf PDF
FY20PN92594A101.pdf PDF
FY20PN92594A-531.pdf PDF
FY20PN92594A-402.pdf PDF
FY20PN92594A-412.pdf PDF
FY20PN92594A-601.pdf PDF
PN92594_W912PM19R00210004.pdf PDF
PN92594_0003_Technical Summary of Changes.pdf PDF
PN92594_W912PM19R00210003.pdf PDF
10 44 16.pdf PDF
FY20PN92594T102.pdf PDF
FY20PN92594M-501.pdf PDF
FY20PN92594M-503.pdf PDF
FY20PN92594IN601.pdf PDF
FY20PN92594A-101.pdf PDF
FY20PN92594A-410.pdf PDF
FY20PN92594T504.pdf PDF
01 33 00.00 37 Submittal Register.pdf PDF
60584960 Table of Contents.pdf PDF
FY20PN92594CG101.pdf PDF
FY20PN92594IN102.pdf PDF
FY20PN92594S-001.pdf PDF
FY20PN92594L-101.pdf PDF
08 33 23.pdf PDF
03 45 00.pdf PDF
FY20PN92594IN101.pdf PDF
FY20PN92594TA501.pdf PDF
PN 92594_RTA SPECS_VOL 05 (Amend0001).pdf PDF
Technical Summary of Changes to W912PM19R0021-0001_pn92594.pdf PDF
Site Visit Sign In Roster 92594 .pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
J&A W912PM19R0021 (PN92594) Chillers.pdf PDF
Show all 50

PN 92594 SOF Operations Support Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

CORRIDOR

LOBBY

SECURITY

CORRIDOR

JANITOR

STAIR 1

ELEVATOR

ELEV MACH

ROOM

AUDITORIUM

1400A

OPEN OFFICE

GEAR STORAGE

WOMEN

COMM

ELEC

WOMEN

JANITOR

EQUIPMENT

LOCKERS

STAIR 2

WELLNESS

CONFERENCE

OFFICE

OFFICE

OFFICE

ARMS ROOM

TESTING AND

EQPT

OPEN OFFICE

CORR

1504MEN

MEN

EQUIPMENT

MAINTENANCE

AREA

PRINT/COPY

OPEN OFFICE

OPEN OFFICE

AV OFFICE

VEST

1502A

ELEC

TRAINING

FURN STORAGE

EXAM ROOM

OFFICE

OFFICE

WAITING

AV OFFICE

VEST

1501A

VESTIBULE

VESTIBULE

FIRST FLOOR

MECHANICAL

VESTIBULE

1500A

1500B

B

B

A

B

A

B

A

B

A

1106A

B

B

1502AB

AA

AA

A

1508B

A

B

1508A

1500A

COMM

1503C

1501AB

LAUNDRY

1503A

A

AUDITORIUM

1400B

1 1

2 2

3 3

4 4

5 5

6 6

7 7

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

T-401

T-402

1 1 1

2 2

2 2

27.0227.24 27.01

27.02

27.01

27.01

27.02

27.01

27.02

27.02

27.02

27.01

27.02

27.02

27.0127.01

SECURE WORK

AREA BOUNDARY

27.01

27.02

27.02

AV AV

AV

2 2

2 2

27.46

27.46

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2

AVAV

6'-6" AFF. 6'-6" AFF.

6'-3" AFF. 6'-3" AFF.

AV

5'-8" AFF.

AV

5'-8" AFF.

AV AV

5'-6" AFF.

2 2

27.02

MOUNT OUTLETS AT 46"

ABOVE COUNTERTOPS.

AV

AV

AV

AV

AV

AV

AV

AV

GENERAL NOTES THIS SHEET:

A. REFER TO SHEET T-001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

B. ALL COMMUNICATIONS CABLING OUTSIDE OF THE SWA AREA SHALL BE

ROUTED TO ROOM 1512; ALL COMMUNICATIONS OUTLET CABLING INSIDE THE

SWA AREA SHALL BE ROUTED TO ROOM 110.

C. REFER TO THE T-500 SERIES SHEETS FOR OUTLET DETAILS.

D. REFER TO AV DRAWINGS (TA), FOR MONITOR HEIGHTS, FOR AV OUTLETS.

8' 4' 0 8' 16' 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E

1 2 3 4 5

A

GRAPHIC SCALES

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

AE

C

O M

S

ER

VI

C

E S, IN

C

S J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

K E

VA

/2

4/

7 8 9 10

B

C

D

E

F

G

TM

J

N

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

-W

2P M

R

T-101

TE

LE

C O

M F

IR

ST

F

LO

O R

P

LA

N

C . B

EN

N

ET

T

B.

M

AR

TI

R

P.

V

IT

O

N

E FY

PN

4T -1

.d w g

READY TO ADVERTISE

1/8" = 1'-0"

TELECOMMUNICATIONS FIRST FLOOR PLAN

SHEET KEYNOTES:

27.01 1-PORT VOICE OUTLET, MOUNTED 4'-6" AFF.TYP.

27.02 VOICE/DATA OUTLET, MOUNTED 18" AFF.TYP.

27.24 1-PORT VOICE OUTLET FOR ELEVATOR WITH CONNECTION TO BE

MADE IN THE ELEVATOR MACHINE ROOM.

27.46 TELECOM FLOOR BOXES ARE "PASS-THRUS" ONLY. ALL CABLES ARE

TO BE HARDWIRED INTO THE FURNITURE DIRECTLY. ALL OTHER

LOCATIONS WILL HAVE THE OUTLETS INSTALLED IN THE FLOOR

BOXES THEMSELVES. TYPICAL FOR THE OPS ROOM 2201 AND

CONFERENCE ROOM 1104 TABLES.

MA

RK

DE

SC

RI

PT

IO

N

DA

TE

RE

VI

SE

D

IN

A

CC

O R

DA

NC

E

W

IT

H

AM

EN

DM

EN

T

M

AR

File details come from the government source that posted it. Updated .