This document provides details for a federal construction contract opportunity with the U.S. Army Corps of Engineers Nashville District. The solicitation seeks a firm fixed-price contract to rehabilitate turbine generator units at Old Hickory Power Plant in Hendersonville, Tennessee, with an estimated value between $25-100 million. The scope of work includes rewinding generators for units 1-3 to increase output to 45 megawatts, replacing turbine runners for the same units, and potentially replacing unit 4's turbine runner. Additional electrical, turbine, and mechanical work involves upgrades and refurbishment of systems to support the increased load. The two-year project consists of model testing and design for the first unit, followed by 18-month installation periods for the remaining base units. The pre-bid site visit will take place on May 5, 2022, and all visit requests must be submitted in advance to the specified POC. The question and answer period is open, with technical inquiries to be submitted through the listed ProjNet website.
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
212768522 Text Box
SKETCH 3 - STUD STIRRUPS ARRANGEMENT AT STATOR SPLIT FLANGES (4 FLANGES)
SKETCH 4 - INSTALLATION OF RETAINING PLATES ON TOP OF BOTTOM SHELF
SKETCH 5 - INSTALLATION OF RETAINING PLATES ON TOP OF INTERMEDIATE SHELF
SKETCH 6 - INSTALLATION OF RETAINING PLATES OVER THE TOP SHELF AND
INSTALLATION OF TIGHTENING PLATES
SKETCH 7 - POSITION OF KEYBARS
H N
-L S-
2- Q
-T -0
_r ev F
RAPPORT D'ANOMALIE
ANOMALY REPORT
DER NC
AR CC
Detection Chantier/ Site Erection Fournisseur/ Supplier Inspection à la réception / As Found Garantie/ POC
(*) Obligation par le fournisseur de compléter cette information/Supplier must complete this mandatory information
Numéro Projet / Project N° Unité / Unit Fournisseur / Supplier Réf. Fournisseur / Supplier Ref. : Réf. Chantier / Site Ref. :
H10395 1
Nom du Projet / Project Name (*) # OA / PO Ligne/Line TRA 210315 Rev. : --
OLD HICKORY WBS # (Budget) : Responsabilité/Responsibility
No. Dessin / Drawing Rev. # Item
TBD
528E594
Titre d’anomalie / Anomaly Title : pipe for dill/drain bearing oil reservoir QTÉ/QTY 2
É m et te u r
Is su er
DESCRIPTION :
See next page
INSPECTEUR / INSPECTOR : DATE :
TRAITEMENT SUGGERE / DISPOSITION PROPOSAL :
See next page
PLEASE SEND WORD FORMAT ONLY TO : hydro.ncr@ge.com
À réapprovisionner / Re-Order (AR) À réparer / repair: GE Fourn/Supplier (NC) Accepté dans l’état / Use as is (NC)
À refaire / Rework (AR) Accepté matériel équivalent/ Use equivalent material (DER) Modif de la conception/ Design modif (NC)
Mise au rebut / Scrap (NC) Changement au contrat / Contract Change (CC) Autres/ Others
Type de défaut / Defect Type : (voir / see HN-LS-2-Q-T-052) Code : 10-2 A B C
G E
DETAILS DE LA DISPOSITION / DISPOSITION DETAILS :
The following steps shall be followed to install the oil pipe:
1. Since the oil pipes are passing between circuit rings 7 & 9 (neutral side), the section of the pipe shall be insulated using the same insulation procedure that was previously submitted for the circuit rings (12 half-lapped layers of insulating tape. Apply one coat of insulating resin 15120A on the pipes and between each layer of insulating tape. When finished with the insulating tape, apply resin 15120A and add one half lapped layer of glass tape over the insulation for mechanical protection)
2. The minimum airgap distance between the insulated pipe and circuit rings shall be greater than 0.8”. Mechanically secure the pipe to maintain equal distance between the two rings
3. It shall be added 2 dielectric unions at the end of the insulated section of pipe (one in each end), see picture below:
4. Perform pressure test for that section as per system parameters
5. A Megger/Hi pot is not required now (after pipe installation), because a final hipot/DC ramp test will be done after rotor installation
PRESCRIT PAR / PRESCRIBED BY : Edson Alves DATE : 04/23/2021
D is tr ib ut io n
Fournisseur / Supplier Client : Information Approbation / Approval Traitement/ treatment
PQL / SQL / BUYER Info Action Équipe GDT / GDT Team
Montage / Site Erection Info Action Autres / Others Ettiene Marcote, Bradley Berreth
212537673 Texte écrit à la machine 48 13 16.00 item 33.1
H N
-L S-
2- Q
-T -0
_r ev F
C
LI
E N
T
S i r eq ui s
If re qu ire d
A pp ro ba tio n
A pp ro va l
Section réservée pour Client et GE / For Client & GE use only Accepté / Accepted Commentaires / Comments :
Accepté tel que noté / Accepted as noted
Refusé / Rejected Signature :
Date :
Ré-inspecté par / Re-inspected by Date Ré-inspecté par / Re-inspected by : Client (Optionnel / Optional) Date
NCR ref.
Non Conformity Management Deviation Request.
PROJECT / PROJET DRAWING N° / PLAN PART NAME / NOM DE LA PIECE
UNIT / UNITE SUPPLIER / FOURNISSEUR CUSTOMER / CLIENT
N O
N C
O N
F O
R M
IT
Y
DETECTION PHASE ORIGIN PROCESS RESPONSIBLE ORGIN PROCESS
CHARACTERISTIC DEFECT / DEFAUT SPECIFIED / SPECIFIE MEASURED / MESURE
DESCRIPTION :
REPORTED BY / RAPPORTEE
PAR:
DATE:
HEN - Installed Base / Generator (HNA &
HLA)
Site Erection
See DescriptionAssembly Interference
528e594
Morin Serge
USACOE
MARCOTTE Etienne
OLD HICKORY 1584
H10395
TRA210315
22/04/2021
4 (GE1)
See Description
When reinstalling UGGB oil pan fill and drain pipes (items 34 & 35 of OEM dwg 528e594), the circuit ring interferes with the OEM path.
OEM routing was just above circuit ring but new circuit ring is taller. See attached pictures.
NCR ref.
Non Conformity Management Deviation Request.
C U
R A
T
IV
E T
R E
A T
M E
N T
TREATMENT / TRAITEMENT :
DEFINED BY / DEFINI PAR : DATE:
C U
S T
O M
E R
D E
C
IS
IO
N ACCEPTED AS SUCH / ACCEPTE COMME TEL
Comments :
ACCEPTED WITH REMARKS / ACCEPTE AVEC
REMARQUES
REJECTED / REFUSE
Name & Signature / Nom et Signature :
Date :
VERIFIED BY / VERIFIE PAR :
DATE :
TRA210315