bafbrwhq15415.pdf

PDF 39 KB Posted

Attached to
RECOVERY-CRWU062071-Repair-Wing Headquarters, Building. 706
Solicitation number
W912LC-09-B-5001
Issued by

About this file

MECHANICAL SPECIFICATIONS RECOVERY - CRWU262071 - Repair Wing Headquarters Building. 706

View the file

Other files

File Type Posted
bafbrwhq15732.pdf PDF
025 A108.PDF PDF
090 E006.PDF PDF
068 M202.PDF PDF
058 M002.PDF PDF
07530 - ELASTOMERIC SINGLE PLY MEMBRANE-FINAL REV-2 _2_.pdf PDF
106 E602.pdf PDF
TEMP TRAILERS-SITE UTILITY.pdf PDF
104 E502.PDF PDF
062 M006.PDF PDF
098 E206.PDF PDF
105 E601.pdf PDF
102 E404.PDF PDF
067 M201.PDF PDF
023 A106.PDF PDF
002 G001.PDF PDF
Summary SOW 6 Aug 09.pdf PDF
018 A026.PDF PDF
TEMP TRAILERS-ARCH.pdf PDF
Bid Addendum 1a CRWU 06-2071.pdf PDF
066 M104.PDF PDF
Bid Schedule Repair Wing HQ final.doc DOC document
BAFBRWHQ 05120.pdf PDF
BAFBRWHQ 03050.pdf PDF
bafbrwhq15732.pdf PDF
bafbrwhq15486.pdf PDF
bafbrwhq15840.pdf PDF
bafbrwhq15820.pdf PDF
bafbrwhq15150.pdf PDF
bafbrwhq15140.pdf PDF
bafbrwhq15995.pdf PDF
bafbrwhq15785.pdf PDF
bafbrwhq15181.pdf PDF
bafbrwhq15815.pdf PDF
bafbrwhq15950.pdf PDF
bafbrwhq15838.pdf PDF
bafbrwhq15145.pdf PDF
bafbrwhq15195.pdf PDF
bafbrwhq15155.pdf PDF
bafbrwhq15550.pdf PDF
bafbrwhq15410.pdf PDF
bafbrwhq15855.pdf PDF
bafbrwhq15900.pdf PDF
bafbrwhq15075.pdf PDF
bafbrwhq15140.pdf PDF
bafbrwhq15055.pdf PDF
bafbrwhq13915.pdf PDF
bafbrwhq15145.pdf PDF
bafbrwhq15122.pdf PDF
bafbrwhq15110.pdf PDF
Show 40 more

Latest 50 of 254 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 15415 REPAIR WING HEADQUARTERS, BLDG 706

DRINKING FOUNTAINS AND WATER COOLERS CRWU 06-2071

06/09/09 15415-1 BUCKLEY AFB

SECTION 15415 - DRINKING FOUNTAINS AND WATER COOLERS

PART 1 - GENERAL

1.01 SUMMARY

A. This Section includes the following water coolers and related components:

1. Pressure water coolers.

2. Fixture supports.

1.02 REFERENCES:

A. Applicable Standards (Latest Edition):

1. Air-Conditioning & Refrigeration Institute (ARI):

a. 1010 - Self-Contained, Mechanically Refrigerated Drinking-Water Coolers.

b. Directory of Certified Drinking-Water Coolers.

2. American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE):

a. 34 - Designation and Safety Classification of Refrigerants.

3. ASME International (ASME):

a. A112.6.1M - Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for

Public Use.

b. A112.18.1 - Plumbing Fixture Fittings.

c. A112.18.2 - Plumbing Fixture Waste Fittings.

d. A112.19.2M - Vitreous China Plumbing Fixtures.

4. Federal Government:

a. Public Law 90-480: Architectural Barriers Act.

b. Public Law 101-336: Americans with Disabilities Act (ADA).

5. International Code Council, Inc. (ICC):

a. A117.1 - Accessible and Usable Buildings and Facilities (ANSI).

6. NFPA:

a. 70 - National Electrical Code.

7. NSF International (NSF):

a. 42 - Drinking Water Treatment Units - Aesthetic Effects.

b. 53 - Drinking Water Treatment Units - Health Effects.

c. 61 - Drinking Water System Components - Health Effects.

1.03 DEFINITIONS:

A. Accessible Water Cooler: Fixture that can be approached and used by people with disabilities.

B. Fitting: Device that controls flow of water into or out of fixture.

C. Fixture: Drinking fountain or water cooler unless one is specifically indicated.

D. Water Cooler: Electrically powered fixture for generating and delivering cooled drinking water.

1.04 SUBMITTALS:

A. General: Submit each item in this Article in accordance with SECTION 15050 - BASIC

MECHANICAL MATERIALS AND METHODS.

B. Product Data: For each fixture indicated. Include rated capacities, furnished specialties, and accessories.

C. Field quality-control test reports.

SECTION 15415 REPAIR WING HEADQUARTERS, BLDG 706

DRINKING FOUNTAINS AND WATER COOLERS CRWU 06-2071

BUCKLEY AFB 15415-2 06/09/09

D. Operation and Maintenance Data: For fixtures to include in emergency, operation, and maintenance manuals.

1.05 QUALITY ASSURANCE:

A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use.

B. Regulatory Requirements: Comply with requirements in ICC A117.1, Public Law 90-480, and Public Law 101-336 for fixtures for people with disabilities.

C. NSF Standard: Comply with NSF 61 for fixture materials that will be in contact with potable water.

D. ARI Standard: Comply with ARI 1010 for water coolers and with ARI's "Directory of Certified Drinking Water Coolers" for type and style classifications.

E. ASHRAE Standard: Comply with ASHRAE 34 for water coolers. Provide HFC 134a (tetrafluoroethane) refrigerant, unless otherwise indicated.

1.06 EXTRA MATERIALS:

A. Furnish extra materials described below that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1. Filter Cartridges: Equal to 5 percent of amount installed for each type and size indicated, but no fewer than 1 of each.

PART 2 - PRODUCTS

2.01 PRESSURE WATER COOLERS:

A. Water Coolers, (EWC-1):

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Elkay Manufacturing Co.

b. Halsey Taylor.

c. Haws Corporation.

d. Larco, Inc.

e. Oasis Corporation.

f. Sunroc Corp.

2. Description: Accessible, ARI 1010, Type PB, pressure with bubbler, Style W, wall-mounting water cooler for adult-mounting height.

a. Cabinet: Single, all stainless steel.

b. Bubbler: One, with adjustable stream regulator, located on each cabinet deck.

c. Control: Push button or Push bar.

d. Supply: NPS 3/8 (DN 10) with ball, gate, or globe valve.

e. Filter: One or more water filters complying with NSF 42 and NSF 53 for cyst and lead reduction to below EPA standards; with capacity sized for unit peak flow rate.

f. Drain(s): Grid with NPS 1-1/4 (DN 32) minimum horizontal waste and trap complying with ASME A112.18.1.

g. Cooling System: Electric, with hermetically sealed compressor, cooling coil, air-cooled condensing unit, corrosion-resistant tubing, refrigerant, corrosion-resistant-metal storage tank, and adjustable thermostat.

SECTION 15415 REPAIR WING HEADQUARTERS, BLDG 706

DRINKING FOUNTAINS AND WATER COOLERS CRWU 06-2071

06/09/09 15415-3 BUCKLEY AFB

(1) Capacity: 8 gph (0.0084 L/s) of 50oF (10oC) cooled water from 80oF (27oC) inlet water and 90oF (32oC) ambient air temperature.

h. Support: Type II, water cooler carrier. Refer to "Fixture Supports" Article.

2.02 FIXTURE SUPPORTS:

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Josam Co.

2. MIFAB Manufacturing, Inc.

3. Smith, Jay R. Mfg. Co.

4. Tyler Pipe; Wade Div.

5. Watts Drainage Products Inc.; a div. of Watts Industries, Inc.

6. Zurn Plumbing Products Group; Specification Drainage Operation.

B. Description: ASME A112.6.1M, water cooler carriers. Include vertical, steel uprights with feet and tie rods and bearing plates with mounting studs matching fixture to be supported.

1. Type II: Bi-level, hanger-type carrier with three vertical uprights.

2. Supports for Accessible Fixtures: Include rectangular, vertical, steel uprights instead of steel pipe uprights.

PART 3 - EXECUTION

3.01 EXAMINATION:

A. Examine roughing-in for water and waste piping systems to verify actual locations of piping connections before fixture installation. Verify that sizes and locations of piping and types of supports match those indicated.

B. Examine walls and floors for suitable conditions where fixtures are to be installed.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.02 APPLICATIONS:

A. Use carrier off-floor supports for wall-mounting fixtures, unless otherwise indicated.

B. Use chrome-plated brass or copper tube, fittings, and valves in locations exposed to view.

Plain copper tube, fittings, and valves may be used in concealed locations.

3.03 INSTALLATION:

A. Install off-floor supports affixed to building substrate and attach wall-mounting fixtures, unless otherwise indicated.

B. Install mounting frames affixed to building construction and attach recessed water coolers to mounting frames, unless otherwise indicated.

C. Install fixtures level and plumb. For fixtures indicated for children, install at height required by authorities having jurisdiction.

D. Install water-supply piping with shutoff valve on supply to each fixture to be connected to water distribution piping. Use ball, gate, or globe valve. Install valves in locations where they can be easily reached for operation. Valves are specified in SECTION 15110 - VALVES.

E. Install trap and waste piping on drain outlet of each fixture to be connected to sanitary drainage system.

F. Install pipe escutcheons at wall penetrations in exposed, finished locations. Use deep-pattern escutcheons where required to conceal protruding pipe fittings. Escutcheons are specified in

SECTION 15050 BASIC MECHANICAL MATERIALS AND METHODS.

SECTION 15415 REPAIR WING HEADQUARTERS, BLDG 706

DRINKING FOUNTAINS AND WATER COOLERS CRWU 06-2071

BUCKLEY AFB 15415-4 06/09/09

G. Seal joints between fixtures and walls and floors using sanitary-type, one-part, mildew-resistant, silicone sealant. Match sealant color to fixture color. Sealants are specified in

DIVISION 7.

3.04 CONNECTIONS:

A. Piping installation requirements are specified in other DIVISION 15 Sections. Drawings indicate general arrangement of piping, fittings, and specialties.

B. Connect fixtures with water supplies, stops, and risers, and with traps, soil, waste, and vent piping. Use size fittings required to match fixtures.

C. Ground equipment in accordance with DIVISION 16.

D. Connect wiring in accordance with DIVISION 16.

3.05 FIELD QUALITY CONTROL:

A. Water Cooler Testing: After electrical circuitry has been energized, test for compliance with requirements. Test and adjust controls and safeties.

1. Remove and replace malfunctioning units and retest as specified above.

2. Report test results in writing.

3.06 ADJUSTING:

A. Adjust fixture flow regulators for proper flow and stream height.

B. Adjust water cooler temperature settings.

3.07 CLEANING:

A. After completing fixture installation, inspect unit. Remove paint splatters and other spots, dirt, and debris. Repair damaged finish to match original finish.

B. Clean fixtures, on completion of installation, according to manufacturer's written instructions.

END OF SECTION 15415