Amendment 0002_G-101.pdf

PDF 527 KB Posted

Attached to
ELECTRICAL SWITCHING STATION NORTH, WATERVLIET ARSENAL, NEW YORK
Solicitation number
W912DS26RA015
Issued by

About this file

This document is a Site Access and Laydown Plan drawing for construction at Watervliet Arsenal in Watervliet, New York, prepared by the U.S. Army Corps of Engineers, New York District. The drawing depicts contractor access routes, material storage areas, and construction limits for a North Switch Station project, with an amendment issued on April 16, 2026.

The plan designates a 100' by 300' contractor laydown area and parking space located in the ball field area, accessible via a future Gillespie Gate. Key requirements for contractors include: installing gravel parking and following storm water codes; providing temporary construction fencing around the laydown area covered with fabric mesh (contractor branding prohibited); maintaining the area and restoring it to like-new condition upon project completion; coordinating all material storage and laydown areas with the Contracting Officer within designated construction limits. Contractors must obtain electrical connections for trailers and temporary facilities, provide temporary internet connectivity for contractor and government use, and adhere to Watervliet Arsenal parking policy WVAR 190-01 and temporary construction permit requirements. Parking is restricted to the designated laydown area; no parking is allowed within the immediate construction area except for material and personnel drop-off/pick-up. Soil containment and testing areas are limited to project construction limits. The plan references existing 480V/1PH power available from breaker 100A in Building 40 that contractors may utilize.

View the file

Other files

File Type Posted
Amendment 0016.pdf PDF
Amendment 0015.pdf PDF
Amendment 0015_23 09 00 and 23 09 23.02.pdf PDF
Amendment 0015_JA for Johnson Controls Inc Metasys.pdf PDF
Amendment 0015_Submittal REGISTER.pdf PDF
Amendment 0014.pdf PDF
Amendment 0013.pdf PDF
Amendment 0012.pdf PDF
Amendment 0011.pdf PDF
Amendment 0011_RFI Photos.pdf PDF
Amendment 0011_33 57 55.pdf PDF
Amendment 0010.pdf PDF
Amendment 0010_Pictures_Switches Nameplates.pdf PDF
Amendment 0009.pdf PDF
Amendment 0009_Photos.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Amendment 0007_Pictures.pdf PDF
Amendment 0007_Site Visit Photos Compressed.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004_01 14 00.pdf PDF
Amendment 0004.pdf PDF
Amendment 0004_C-001.pdf PDF
Amendment 0003.pdf PDF
Amendment 0003_ Site Visit Photos.pdf PDF
Amendment 0003_Site Visit Sign In Sheet_06MAY2026.pdf PDF
Amendment 0002.pdf PDF
Amendment 0002_01 14 00.pdf PDF
Amendment 0002_01 50 00.pdf PDF
Amendment 0001_JA - ESS North - North - Square D.pdf PDF
Amendment 0001_ JA - ESS North - CAC-IDS.pdf PDF
Amendment 0001_ Dwg MS101.pdf PDF
Amendment 0001.pdf PDF
Amendment 0001_ JA - ESS North - Fire Alarm.pdf PDF
Amendment 0001_ Spec 33 57 55.pdf PDF
Evaluation Factors.pdf PDF
Drawings.pdf PDF
Specifications.pdf PDF
Solicitation - W912DS26RA015.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAME 50

FOUNTAIN

D A L L I S A

SCALE W A G N E R

NATIONAL

GUARD

STORAGE

AREA

SHED

P.O.L. FACILITY

NO 19

NO 1

R O A D

VETMEM

A V E N U E

FOUNTAIN

M

OIL TANK

GA

NT

RY

C

RA

NE

W

AY

GA

NT

RY

C

RA

NE

W

AY

ST

EW

AR

T

PL

AT

FO

RM

NO

TA

LC

OT

T

R

OA

D

W H

I T T

M O

R E

M A

C N

U T

T L A

N E

RO

AD

GA

S

PU

MP

S

B E

N E

T S

T R

E E

T

B R

O A

D W

A Y

LANE

SCALE

138139

NO 17

MAIN

SUBSTATION

NO 1

SCALE

W E S T E R V E L T A V E N U E

R O A D

NO 1

ME

TT

LE

R

R

OA

D

R O

A D

B R

O A

D W

A Y

PARADE

GROUNDS

BALL

FIELD

BRICKERPROPERTY

DISPOSAL

AREA

ROLL-OFF

DUMPSTER

T E N T H S T R E E T

PLAY

GROUND

DRINKING FOUNTAIN

G I B

S O

N

S T

R E

E T

POOL

FLAGPOLE

3 R D A V E

P A R K E R R O A D

SYMINGTON STREET

M O

N R

O E

S T

R E

E T

FACILITIES WATERVLIET ARSENAL, NY

OIL

STORAGE

A

RN

OL

D

LA

NE

F A

R L E

Y

R

I V E

W H

I T T

M O

E

A

D

S C

H U

L L

A

D

M O R D E C A I D R I V E

B U

F F

I N G

T

R E

E T

TH

OR

NT

ON

OA

D

G I B S O N S T R E E T

SOUTH

GATEG

I L L

E S

P I E

A D

SHAKER ROAD N.Y.

STATE OVERPASS

WORTH

ROAD

B A K E R R

O A D

B A K

E R

R O

A D

B A K E R R

O A D

PARKER ROAD

152 141

35A

41A

12NAME PKG

PKG

PKG

PKG 39

OIL TANK

PKG33

GA

NT

RY

C

RA

NE

W

AY

GA

NT

RY

C

RA

NE

W

AY

PK

G

NO

PK

G

138139

PKG

M3

MAIN

SUBSTATION

PKG 32

NO 1

PKG

SCALE

PKG

NO 1

P

KG

M O

N R

O E

S T

R E

E T

SHAKER ROAD N.Y.

STATE OVERPASS

ROUTE 155 WORTH

B A K

E R

R O

D

PARKER ROAD

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N M

A R

K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

US Army Corps of Engineers

U S

A

R M

Y

C

O R

F

E

N G

I N

E E

R S

N E

W

Y

O R

K

D

I S

T R

I C

T

F

E D

E R

A L

P

L A

Z A

N E

W

Y

O R

K

N

Y

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

A

Y or k S t P or tla nd , M

E

7.

3.

SHEET ID

W A

T E

R V

L I E

T

A

R S

E N

A L

W A

T E

R V

L I E

T

N

W

Y

R

K

N O

R T

H

S

W I T

H

A

T I O

N

X

A N

S I

D

I S

S U

F

N

S T

R U

C T

I O

N

G-101

S I T

E

A

C C

E S

S

A

L

Y

D O

W

L A

N

H L S

D S

E

L D

A

B C

T

X

SCALE: 1" = 200'

CONTRACTOR ACCESS AND LAYDOWN PLANC1

SCALE: 1"=75'

SWITCH STATION ENLARGED PLANA5

FUTURE GILLESPIE

GATE ROADWAYS

CONSTRUCTION LIMITS

0 200' 400'

Scale: 1" = 200'-0"

0 75' 600'

Scale: 1" = 75'-0"

NEW SWITCH

STATION BUILDING

CONTRACTOR ACCESS AT

FUTURE GILLESPIE GATE

NOTES:

1. THE CONTRACTOR MUST COORDINATE MATERIAL STORAGE AND LAYDOWN AREAS WITH THE

CONTRACTING OFFICER. LAYDOWN AREAS AND MATERIAL STORAGE AREAS MUST OCCUR ONLY WITHIN

THE CONSTRUCTION LIMITS AND DESIGNATED LAYDOWN AREA.

2. 100' BY 300' SPACE TO BE USED FOR CONTRACTOR LAYDOWN AREA AND PARKING. CONTRACTOR MUST

WORK AROUND EXISTING SHED, BACKSTOP FENCE, BALL FIELD, AND BLEACHERS TO REMAIN.

2.1. INSTALL GRAVEL PARKING

2.2. FOLLOW ANY STORM WATER CODES

2.3. PROVIDE MAINTENANCE TO THE AREA (EXISTING SNOW REMOVAL)

2.4. PROVIDE TEMPORARY CONSTRUCTION FENCING AROUND LAYDOWN AREA, SEE DETAIL A1/C-504.

2.5. RESTORE LAYDOWN AREA GRAVEL PARKING AND FENCE TO LIKE-NEW CONDITION AT THE END OF

THE PROJECT.

3. FENCING SURROUNDING THE LAYDOWN AREA MUST BE COVERED IN FABRIC MESH AND CONTRACTOR

BRANDING OR LABELING IS PROHIBITED.

4. CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL CONNECTIONS (FEEDER TAP, LOCAL DISCONNECT, AND WIRING REQUIRED) FOR TRAILERS AND TEMPORARY FACILITIES. THE TRAILERS MUST BE LOCATED WITHIN THE CONTRACTOR LAYDOWN AREA IN THE BALL FIELD, SEE THE PLAN VIEW C1 ON THIS SHEET.

5. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY INTERNET CONNECTIVITY FOR CONTRACTOR AND

GOVERNMENT AT LAYDOWN AREAS AND ON PROJECT SITE.

6. CONTRACTOR PARKING IS LIMITED TO WITHIN THE CONTRACTOR LAYDOWN AREA AND AREAS ALLOWED PER WVAR 190-01 MOTOR VEHICLE TRAFFIC SUPERVISION. NO ADDITIONAL LOCATIONS FOR ON SITE

PARKING WILL BE ALLOWED.

7. SOIL CONTAINMENT AND TESTING AREAS ARE LIMITED TO THE PROJECT CONSTRUCTION LIMITS.

8. CONTRACTORS TO ADHERE TO WVA PARKING POLICY WVAR190-01 (MOTOR VEHICLE TRAFFIC

SUPERVISION) FOR THE DURATION OF THE PROJECT. CONTRACTORS ARE ONLY ALLOWED TO PARK WITHIN DESIGNED LOCATIONS ON POST OR WITHIN THE CONFINES OF THE CONTRACTOR'S DESIGNATED

LAYDOWN AREA, AS DIRECTED BY THE WATERVLIET ARSENAL.

9. CONTRACTORS TO ADHERE TO THE "WATERVELIET ARSENAL (WVA) TEMPORARY CONSTRUCTION PERMIT APPLICATION & TECHNICAL REVIEW" REQUIREMENTS FOR THE DURATION OF THE PROJECT, AS DICTATED

BY THE WATERVLIET ARSENAL.

10. NO POV PARKING ALLOWED WITHIN THE CONFINES OF THE IMMEDIATE CONSTRUCTION AREA. ANY VEHICLES OPERATING IN THE IMMEDIATE CONSTRUCTION AREA WILL BE ALLOWED FOR MATERIAL AND

PERSONNEL PICK-UP AND DROP-OFF ONLY.

CONSTRUCTION

LIMITS

CONTRACTOR LAYDOWN

AREA, SEE NOTE 2

CONTRACTOR CAN UTILIZE THE

EXISTING 480V/ 1PH POWER IN

B.42 FED FROM BREAKER 100A

IN B.40

A M

E N

D M

E N

T

190-01 (MOTOR VEHICLE TRAFFIC

Sheets and Views
G-101

File details come from the government source that posted it. Updated .