Specifications_-_Amendment__4.pdf

PDF 65 KB Posted

Attached to
FY13 Flight Activity Facility, Lakehurst Naval Station, New Jersey
Solicitation number
W912DS-13-R-0017
Issued by

About this file

Amendment 0004 Revised Specifications

View the file

Other files

File Type Posted
EP602.pdf PDF
EP407.pdf PDF
EP601.pdf PDF
EP411.pdf PDF
10_56_26.pdf PDF
ET105.pdf PDF
M-701.pdf PDF
ES105.pdf PDF
EP404.pdf PDF
Amendment_0007.pdf PDF
A-606.pdf PDF
41_22_13.15.pdf PDF
F-103.pdf PDF
ET601.pdf PDF
ET106.pdf PDF
ET103.pdf PDF
Amendment_0006_Attachment_6.pdf PDF
Amendment_0006_Attachment_4.pdf PDF
Amendment_0006_Attachment_2.pdf PDF
Amendment_0006_Attachment_10.pdf PDF
Amendment_0006_Attachment_3.pdf PDF
Amendment_0006_Attachment_9.pdf PDF
Amendment_0006_Attachment_8.pdf PDF
Amendment_0006.pdf PDF
Amendment_0006_Attachment_1.pdf PDF
Amendment_0006_Attachment_5.pdf PDF
Amendment_0006_Attachment_7.pdf PDF
Amendment_0005_Revised_Drawings.pdf PDF
Amendment_0005.pdf PDF
WBS_Fill-In.pdf PDF
Revised_drawings_-_Amendment_4.pdf PDF
Amendment_0004.pdf PDF
Revised_Civil_Drawings_-_Amendment_3.pdf PDF
Revised_Architectural_Drawing_2_-_Amendment_3.pdf PDF
Specifications_-_Amendment_3.pdf PDF
Revised_Architectural_Drawing_1_-_Amendment_3.pdf PDF
Revised_Interior_Drawings_-_Amendment_3.pdf PDF
AMENDMENT_0003.pdf PDF
Amendment_0002.pdf PDF
Amendment_2 _Revised_Specs..pdf PDF
Amendment_2 _Drawings.pdf PDF
Drawings_1__M-306_and_M-603.pdf PDF
Amendment_0001.pdf PDF
Drawings_2___B-107_THRU_B-111.pdf PDF
Drawing_Vol_1B_.pdf PDF
00800_Exhibits.pdf PDF
Drawing_Vol_2C.pdf PDF
Spec_-_Volume_2.pdf PDF
Drawing_Vol_1A_.pdf PDF
Drawing_Vol_2A.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FY13 CERDEC FLIGHT ACTIVITY FACILITY

LAKEHURST NAES - JB MCGUIRE/DIX/LAKEHURST, NEW JERSEY MAY 30, 2013

SECTION 08 71 00

DOOR HARDWARE

08/08

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

BHMA A156.1 (2006) Butts and Hinges

BHMA A156.13 (2005) Mortise Locks & Latches, Series 1000

BHMA A156.15 (2006) Closer Holder Release Devices

BHMA A156.16 (2002) Auxiliary Hardware

BHMA A156.18 (2006) Materials and Finishes

BHMA A156.21 (2006) Thresholds

BHMA A156.22 (2005) Door Gasketing and Edge Seal Systems

BHMA A156.3 (2001) Exit Devices

BHMA A156.4 (2000) Door Controls - Closers

BHMA A156.5 (2001) Auxiliary Locks & Associated Products

BHMA A156.6 (2005) Architectural Door Trim

BHMA A156.7 (2003) Template Hinge Dimensions

BHMA A156.8 (2005) Door Controls - Overhead Stops and Holders

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 101 (2012) Life Safety Code

NFPA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening Protectives

SECTION 08 71 00 Page 1

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specification for Standard Steel Doors and Frames

UNDERWRITERS LABORATORIES (UL)

UL Bld Mat Dir (2011) Building Materials Directory

1.2 SUBMITTALS

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES.

SD-02 Shop Drawings

Hardware schedule; G, RO

Hardware consultant shall seal and sign the door hardware construction submittal.

Keying system; G, RO

SD-03 Product Data

Hardware items; G, RO

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule items, Data Package 1; G, RO

Submit data package in accordance with Section 01 78 23.00 18

OPERATION AND MAINTENANCE DATA.

SD-11 Closeout Submittals

Key Bitting; G, RO

1.3 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Reference Mfr. UL Mark Publi- Name Key (If fire BHMA Hard- cation and Con- rated Finish ware Quan- Type Catalog trol and Designa- Item tity Size No. Finish No. Symbols listed) tion

1.4 KEY BITTING CHART REQUIREMENTS

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (AA1, AA2, etc.).

SECTION 08 71 00 Page 2

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.5 QUALITY ASSURANCE

1.5.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.5.1 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware subcontractor, using Activity, Joint Base personnel and a representative from BEST/Stanley shall meet to discuss key requirements for the facility. A keying schedule will be developed at this meeting. Once the keying schedule has been finalized, the Contractor shall order the BEST cores.

1.6 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown in hardware schedule. Deliver permanent keys and removable cores to the Joint Base, either directly or by certified mail to be installed by the government. Deliver construction master keys with the locks.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Provide hardware to be applied to metal manufactured to template. Promptly furnish template information or templates to door and frame manufacturers.

Conform to BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 80 for fire doors and NFPA 101 for exit doors, as well as to other requirements indicated, even if such hardware is not specifically mentioned under paragraph entitled "Hardware Schedule." Provide the label of Underwriters Laboratories, Inc. for such hardware listed in UL Bld Mat Dir or labeled and listed by another testing laboratory acceptable to the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the

SECTION 08 71 00 Page 3 identifying mark will be visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.

2.3.1 Hinges

BHMA A156.1, 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for exterior doors and reverse-bevel interior doors so that pins will be nonremovable when door is closed. Other antifriction bearing hinges may be provided in lieu of ball-bearing hinges.

2.3.2 Locks and Latches

2.3.2.1 Mortise Locks and Latches

BHMA A156.13, Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to suit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Install knobs and roses of mortise locks with screwless shanks and no exposed screws.

2.3.2.2 Combination Locks

BHMA A 156.2. Heavy-duty, mechanical combination lockset with 5 pushbuttons, standard-sized knob or lever, 3/4 inch deadlocking latch, 2-3/4 inch back-set. Provide deadbolt key override option. Safelock, Simplex, and Venn are acceptable manufacturers. Provide a hardware grade equivalent to Grade 1, series 4000. Provide a 5-year parts and labor warranty.

A door into a sensitive area shall be fitted with a FF-L-2740A X-09 Heavy-duty, combination Electromechanical Deadbolt lock for pedestrian doors, with a drill resistant dial ring mounting plate, 2-3/4 inch back-set, with Automatic Lock Reset, High-Security combination scramble, and resistant to all forms of external manipulation and environmental attack. KABA-MAS is the acceptable manufacturer. Three Modes of Operation: 1) The Single Combination Mode allows access by dialing a six-digit combination. 2) The Dual Combination Mode allows access only when two separate codes are entered within 10 seconds of one another. 3) The Supervisory/Subordinate Mode allows access by a subordinate only after a supervisor code has been entered. Audit Feature: Lock shall have a full compliment of auditing features, including non-resettable openings log, and unsuccessful attempts log (audits after 3 unsuccessful attempts) that resets once the proper access code is entered. Lock shall generate its own electrical energy with each turn of the dial, with no batteries or wires required. Lock shall be designed to fit industry standard door mounting pattern.

2.3.3 Exit Devices

BHMA A156.3, Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons, not less than 7 by 2-1/4 inch.

2.3.4 Exit Locks With Alarm

BHMA A156.5, Type E0431 (with full-width horizontal actuating bar) for single doors; Type E0431 (with actuating bar) or E0471 (with actuating bar

SECTION 08 71 00 Page 4 and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified. Provide terminals for connection to remote indicating panel. Provide outside control key.

2.3.5 Cylinders and Cores

Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with seven pin tumblers. Provide cylinders and cores from the Best Lock Corporation, no substitution, using the keyway standard at JB McGuire/Dix/Lakehurst. Rim cylinders and mortise cylinders shall have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.

2.3.6 Keying System

Provide a master keying system Provide construction interchangeable cores.

Provide key cabinet as specified.

The Contractor shall coordinate a keying system meeting. The Contractor’s Project Manager, Superintendent, Hardware Subcontractor, Designer of Record, Contracting Officer, Public Works Base Hardware Specialist, and the Using Activity shall attend this meeting to establish the keying system for the project. This meeting is intended to identify Base limitations, the necessary security, and access control within the facility. The meeting shall produce a marked up copy of the floor plan indicating the doors to receive locks and the doors to be keyed together, and any master keying.

Comm rooms shall be keyed to JB MDL Public Works Utility Master Key.

2.3.7 Lock Trim

Cast, forged, or heavy wrought construction and commercial plain design.

2.3.7.1 Lever Handles

Provide lever handles in lieu of knobs . Conform to the minimum requirements of BHMA A156.13 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.8 Keys

Furnish one file key, one duplicate key, and one working key for each key change and for each master keying system. Stamp each key with appropriate key control symbol and "U.S. property - Do not duplicate." Do not place room number on keys.

2.3.9 Door Bolts

BHMA A156.16. Provide dustproof strikes for bottom bolts, except for doors having metal thresholds. Automatic latching flush bolts: BHMA A156.3, Type 25.

SECTION 08 71 00 Page 5

2.3.10 Closers

BHMA A156.4, Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers and other features necessary for the particular application. Size closers in accordance with manufacturer's recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

2.3.11 Overhead Holders

BHMA A156.8.

2.3.12 Closer Holder-Release Devices

BHMA A156.15.

2.3.13 Door Protection Plates

BHMA A156.6.

2.3.13.1 Sizes of Armor Mop and Kick Plates

Provide armor, mop, and kick plates conforming to BHMA A 156.6. Provide door kick plates on all doors with closers and doors leading to corridors or circulation spaces. Provide armor plates on all doors that receive cart traffic. Provide mop plates on all doors in rooms that have a mop-able floor finish.

2 inch less than door width for single doors; one inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors .

Provide a minimum 36 inch armor plates for flush doors, except 16 inch high armor plates on fire doors. Provide 4 inch mop plates.

2.3.14 Door Stops and Silencers

BHMA A156.16. Silencers Type L03011. Provide three silencers for each single door, two for each pair.

2.3.15 Thresholds

BHMA A156.21.

2.3.16 Weather Stripping Gasketing

BHMA A156.22. Provide the type and function designation where specified in paragraph entitled "Hardware Schedule". Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weather stripped doors not to exceed 1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E 283.

Provide weather stripping with one of the following:

2.3.16.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide bronze anodized aluminum.

SECTION 08 71 00 Page 6

2.3.17 Rain Drips

Extruded aluminum, not less than 0.08 inch thick, bronze anodized. Set drips in sealant and fasten with stainless steel screws.

2.3.17.1 Door Rain Drips

Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.17.2 Overhead Rain Drips

Approximately 1-1/2 inch high by 2-1/2 inch projection, with length equal to overall width of door frame. Align bottom with door frame rabbet.

2.3.18 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of proper type, quality, size, quantity, and finish with hardware. Provide stainless steel or nonferrous metal fasteners that are exposed to weather. Provide fasteners of type necessary to accomplish a permanent installation.

2.5 FINISHES

BHMA A156.18. Provide hardware in BHMA 630 finish (satin stainless steel), except hardware for bronze aluminum doors, unless specified otherwise.

Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish .

Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

Match hardware finish for aluminum doors to match the doors. Provide hardware in BHMA 612 finish (satin bronze), unless specified otherwise.

Finish surface door closers bronze paint finish. Provide steel hinges in BHMA 639 finish (satin bronze plated) . Provide exposed parts of concealed closers finish to match lock and door trim.

2.6 KEY CABINET AND CONTROL SYSTEM

BHMA A156.5, Type required to yield a capacity (number of hooks) 25 percent greater than the number of key changes used for door locks.

2.7 KEY BOXES

Provide Knox Box Company, Series 3200 high security commercial key box without tamper switch. Box shall be flush mounted with hinged door.

Provide unit with 1/4 inch plate steel housing and 1/2 inch thick steel door with interior gasket seal. Box and lock shall be UL listed. Lock shall have 1/8 inch dust cover. Lock shall have double action rotating tumblers and hardened steel pins accessed by a biased cut key. Finish

SECTION 08 71 00 Page 7 shall be dark bronze. Provide 2 keys for each box keyed to JBMDL Fire Department Standard.

At Hangar Doors: Flush mount box on masonry wall near the hangar door opening where shown on drawings, mounted at 5 feet AFF to centerline of box.

b. At South Entry: Flush mount box on metal wall panel mounted at 5 feet AFF to centerline of box.

PART 3 EXECUTION

3.1 INSTALLATION

Install hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weather Stripping Installation

Handle and install weather stripping to prevent damage. Provide full contact, weather-tight seals. Operate doors without binding.

3.1.1.1 Stop-Applied Weather Stripping

Fasten in place with color-matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.2 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves.

3.2 FIRE DOORS AND EXIT DOORS

Install hardware in accordance with NFPA 80 for fire doors, NFPA 101 for exit doors .

3.3 HARDWARE LOCATIONS

SDI/DOOR A250.8, unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 KEY CABINET AND CONTROL SYSTEM

Locate where directed . Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Furnish complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.

SECTION 08 71 00 Page 8

3.5 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, as directed, errors in cutting and fitting and damage to adjoining work.

3.6 HARDWARE SETS

SECTION 08 71 00 Page 9

Provide hardware for aluminum doors under this section. Deliver Hardware templates and hardware, except field-applied hardware to the aluminum door and frame manufacturer for use in fabricating the doors and frames.

Set No. 01

Provide each RU door(s) with the following:

1 ALL HARDWARE BY DOOR MANUFACTURER

Set No. 02

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA ENTRANCE LOCK ND92HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA WALL STOP WS407CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Set No. 03

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA ENTRANCE LOCK ND92HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

3 EA SILENCER SR64 GRY IVE

Set No. 04

Provide each PR door(s) with the following:

8 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 SET AUTO FLUSH BOLT FB31P OR FB41P AS REQ 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA STOREROOM LOCK ND96HD RHO 14-042 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA COORDINATOR COR X FL X MTG BRKTS X

HW PREPS X LENGTH AS REQ 628 IVE

1 SET ASTRAGAL 9605A HEIGHT AS REQ

(OMIT @ NON-RATED DOORS) CL NGP

2 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

2 EA KICK PLATE 8400 10" X 1" LDW 630 IVE

2 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

Set No. 05

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA STOREROOM LOCK ND96HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

SECTION 08 71 00 Page 10

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR &

PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

Set No. 06

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA STOREROOM LOCK ND96HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

Set No. 07

Provide each PR door(s) with the following:

6 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 SET AUTO FLUSH BOLT FB31P OR FB41P AS REQ 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA STOREROOM LOCK ND96HD RHO 14-042 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 SET ASTRAGAL 9605A HEIGHT AS REQ

(OMIT @ NON-RATED DOORS) CL NGP

2 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

2 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

2 EA KICK PLATE 8400 10" X 1" LDW 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

Set No. 08

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA STOREROOM LOCK ND96HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

Set No. 09

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

SECTION 08 71 00 Page 11

1 EA CLASSROOM LOCK ND94HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA WALL STOP WS407CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Set No. 10

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA CLASSROOM LOCK ND94HD RHO 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

Set No. 11

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA FIRE EXIT HARDWARE 98NL-F LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH KEYED CONST. CORE 626 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS 5050B H & J BRN NGP

Set No. 12

Provide each PR door(s) with the following:

8 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

2 EA PUSH BAR 9100 LENGTH AS REQ 630 VON

2 EA OFFSET DOOR PULL 8190-0-O 630 IVE

2 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

2 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 MEETING STILE SEAL BY DOOR MANUFACTURER

1 PERIMETER SEAL BY FRAME MANUFACTURER

Set No. 13 Not Used

Set No. 14

Provide each PR door(s) with the following:

6 EA HINGE 5BB1HW 4.5 X 4.5 630 IVE

2 EA DUMMY TOUCH BAR 350 LENGTH AS REQ 630 VON

2 EA DUMMY PULL 990DT 626 VON

SECTION 08 71 00 Page 12

2 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

2 EA KICK PLATE 8400 10" X 1" LDW 630 IVE

2 EA WALL STOP WS407CCV 630 IVE

2 EA SILENCER SR64 GRY IVE

Set No. 15 For use on door(s):

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 630 IVE

1 EA PUSH PLATE 8200 4" X 16" 630 IVE

1 EA PULL PLATE 8303EZ-0 4" X 16" 630 IVE

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR & PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 EA WALL STOP WS407CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Set No. 16

Provide each SGL door(s) with the following:

4 EA HINGE 5BB1HW 4.5 X 4.5 630 IVE

1 EA DUMMY TOUCH BAR 350 LENGTH AS REQ 630 VON

1 EA OFFSET DOOR PULL 8190-0-O 630 IVE

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 PERIMETER SEAL BY FRAME MANUFACTURER

Set No. 17

Provide each PR door(s) with the following:

8 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

2 EA PUSH BAR 9100 LENGTH AS REQ 630 VON

2 EA OFFSET DOOR PULL 8190-0-O 630 IVE

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA AUTO. OPERATOR 9540 SERIES X MTG BKRT, SPCRS

& PLATE AS REQ (LHR LEAF) 628 LCN

2 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 EA POWER SUPPLY PS914-4RL GRY VON

1 EA BOLLARD ACTUATOR 8310-3853TWB LCN

1 EA WEATHER RING 8310-800 LCN

1 EA ACTUATOR, WALL MOUNT 8310-856T LCN

1 EA RECEIVER 8310-865 LCN

1 EA BOLLARD POST 8310-866 LCN

1 EA FLUSH MOUNT BOX 8310-868F LCN

1 MEETING STILE SEAL BY DOOR MANUFACTURER

1 PERIMETER SEAL BY FRAME MANUFACTURER

Set No. 18

Provide each PR door(s) with the following:

8 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

2 EA POWER TRANSFER EPT-10 689 VON

1 EA MULLION KR4954 HEIGHT AS REQ 689 VON

SECTION 08 71 00 Page 13

1 EA PANIC HARDWARE RX-EL98EO LENGTH AS REQ 630 VON

1 EA PANIC HARDWARE RX-EL98NL-OP LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING

WITH KEYED CONST. CORE 626 SCH

2 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA MORTISE CYLINDER SFIC HOUSING X TP AS REQ

WITH KEYED CONST. CORE 626 SCH

2 EA OFFSET DOOR PULL 8190-0-O 630 IVE

1 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA AUTO. OPERATOR 9540 SERIES X MTG BKRT, SPCRS

& PLATE AS REQ (LHR LEAF) 628 LCN

2 EA WALL STOP WS407CCV 630 IVE

1 EA POWER SUPPLY PS914-4RL GRY VON

2 EA ACTUATOR, WALL MOUNT 8310-856T LCN

2 EA FLUSH MOUNT BOX 8310-868F LCN

2 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 MEETING STILE SEAL BY DOOR MANUFACTURER

1 PERIMETER SEAL BY FRAME MANUFACTURER

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 19 For use on door(s):

Provide each SGL door(s) with the following:

4 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA POWER TRANSFER EPT-10 689 VON

1 EA PANIC HARDWARE RX-EL98NL-OP LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH

KEYED CONST. CORE 626 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA PUSH BUTTON SWITCH 603RDEX LOC

1 EA OFFSET DOOR PULL 8190-0-O 630 IVE

1 EA AUTO. OPERATOR 9540 SERIES X MTG BKRT,

SPCRS & PLATE AS REQ 628 LCN

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 EA POWER SUPPLY PS914-4RL GRY VON

2 EA ACTUATOR, WALL MOUNT 8310-856T LCN

2 EA FLUSH MOUNT BOX 8310-868F LCN

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 PERIMETER SEAL BY FRAME MANUFACTURER

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

CONNECT PANIC HARDWARE TO REMOTE ACTIVATION SWITCH IN RECEPTION/SECURITY 157.

Set No. 20

Provide each SGL door(s) with the following:

2 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 630 IVE

1 EA EU STOREROOM LOCK ND96HDEU RHO X RX SWITCH 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

SECTION 08 71 00 Page 14

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR

& PLATE AS RE 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 21

Provide each PR door(s) with the following:

5 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 630 IVE

1 SET AUTO FLUSH BOLT FB31P OR FB41P AS REQ 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA EU STOREROOM LOCK ND96HDEU RHO 14-042 X RX SWITCH 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 SET ASTRAGAL 9605A HEIGHT AS REQ (OMIT

@ NON-RATED DOORS) CL NGP

2 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

2 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

2 EA KICK PLATE 8400 10" X 1" LDW 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

1 EA POWER SUPPLY PS902 SCE

2 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 22

Provide each SGL door(s) with the following:

2 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 630 IVE

1 EA EU STOREROOM LOCK ND96HDEU RHO X RX SWITCH 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 23

SECTION 08 71 00 Page 15

Provide each PR door(s) with the following:

5 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA ELECTRIC HINGE 5BB1 4.5 X 4.5 TW8 630 IVE

1 SET AUTO FLUSH BOLT FB31P OR FB41P AS REQ 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA EU STOREROOM LOCK ND96HDEU RHO 14-042 X RX SWITCH 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 SET ASTRAGAL 9605A HEIGHT AS REQ (OMIT

@ NON-RATED DOORS) CL NGP

2 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

2 EA KICK PLATE 8400 10" X 1" LDW 630 IVE

2 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

1 EA POWER SUPPLY PS902 SCE

2 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 24

Provide each PR door(s) with the following:

8 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

2 EA POWER TRANSFER EPT-10 689 VON

1 EA MULLION KR4954 HEIGHT AS REQ 689 VON

1 EA PANIC HARDWARE RX-EL98EO LENGTH AS REQ 630 VON

1 EA PANIC HARDWARE RX-EL98NL-OP LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH

KEYED CONST. CORE 626 SCH

2 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA MORTISE CYLINDER SFIC HOUSING X TP AS REQ

WITH KEYED CONST. CORE 626 SCH

2 EA OFFSET DOOR PULL 8190-0-O 630 IVE

2 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

2 EA WALL STOP WS407CCV 630 IVE

1 EA POWER SUPPLY PS914-2RS GRY VON

2 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 MEETING STILE SEAL BY DOOR MANUFACTURER

1 PERIMETER SEAL BY FRAME MANUFACTURER

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 25

Provide each PR door(s) with the following:

6 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

2 EA POWER TRANSFER EPT-10 689 VON

1 EA MULLION KR9954 HEIGHT AS REQ 689 VON

1 EA FIRE EXIT HARDWARE RX-EL98DT-F X 499F LENGTH AS REQ 630 VON

1 EA FIRE EXIT HARDWARE RX-EL98NL-F X 499F LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH

KEYED CONST. CORE 626 SCH

2 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

SECTION 08 71 00 Page 16

EXISTING BEST KEY SYSTEM 626 BES

1 EA MORTISE CYLINDER SFIC HOUSING X TP AS REQ

WITH KEYED CONST. CORE 626 SCH

1 SET ASTRAGAL 9605A HEIGHT AS REQ CL NGP

2 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

2 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

2 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS 5050B H & J BRN NGP

1 EA POWER SUPPLY PS914-2RS-FA GRY VON

2 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 MEETING STILE SEAL BY DOOR MANUFACTURER

1 PERIMETER SEAL BY FRAME MANUFACTURER

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

WIRE THE ELECTRIFIED LATCH BOLTS TO THE FIRE ALARM SYSTEM. THE ELECTRIFIED

LATCH BOLTS ARE TO REMAIN IN THE EXTENDED POSITION UPON ACTIVATION OF THE

FIRE ALARM SYSTEM, UNLESS MANUALLY RETRACTED BY THE PUSH PADS OR KEY OVERRIDE.

Set No. 26

Provide each SGL door(s) with the following:

4 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA POWER TRANSFER EPT-10 689 VON

1 EA PANIC HARDWARE RX-EL98NL-OP LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH

KEYED CONST. CORE 626 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA OFFSET DOOR PULL 8190-0-O 630 IVE

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 EA POWER SUPPLY PS914-2RS GRY VON

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 PERIMETER SEAL BY FRAME MANUFACTURER

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 27

Provide each SGL door(s) with the following:

4 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA POWER TRANSFER EPT-10 689 VON

1 EA PANIC HARDWARE RX-EL98NL LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING

WITH KEYED CONST. CORE 626 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" CL NGP

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

SECTION 08 71 00 Page 17

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 EA POWER SUPPLY PS914-2RS GRY VON

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 28

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1 4.5 X 4.5 (NRP @ OUTSWING DRS) 630 IVE

1 EA STOREROOM LOCK ND96HD RHO X LESS STRIKE 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA ELECTRIC STRIKE 6212WF DS-LC FSE VOLTAGE AS REQ 630 VON

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 100S SERIES X SIZE & BRKT AS REQ 630 GLY

1 SET SEALS 5050B H & J (USE SILENCERS

@ NON-RATED DOORS) BRN NGP

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

WIRE ELECTRIC MONITOR SWITCH TO BALANCED MAGNETIC SWITCH FOR

REQUEST TO EXIT CAPABILITY.

Set No. 29

Provide each RU door(s) with the following:

HARDWARE BY DOOR MANUFACTURER

Set No. 30

Provide each SGL door(s) with the following:

2 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA ELECTRIC HINGE 5BB1HW 4.5 X 4.5 TW8 630 IVE

1 EA EU STOREROOM LOCK ND96HDEU RHO X RX SWITCH 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" CL NGP

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 31

Provide each PR door(s) with the following:

8 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

SECTION 08 71 00 Page 18

1 EA MANUAL FLUSH BOLT FB458-12" (BOTTOM) 626 IVE

1 EA MANUAL FLUSH BOLT FB458-24" (TOP) 626 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA STOREROOM LOCK ND96HD RHO 14-042 630 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA ASTRAGAL BY DOOR MANUFACTURER

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

2 EA KICK PLATE 8400 10" X 1" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 SET SEALS 5050B HEIGHT AS REQ

(MOUNT TO ASTRAGAL) BRN NGP

1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" CL NGP

2 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

Set No. 32

Provide each PR door(s) with the following:

8 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA MULLION KR4954 HEIGHT AS REQ 689 VON

1 EA PANIC HARDWARE LD98EO LENGTH AS REQ 630 VON

1 EA PANIC HARDWARE LD98NL LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH

KEYED CONST. CORE 626 SCH

2 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA MORTISE CYLINDER SFIC HOUSING X TP AS REQ

WITH KEYED CONST. CORE 626 SCH

1 EA MULLION SEAL 5100 HEIGHT AS REQ BLK NGP

2 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

2 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" CL NGP

2 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

Set No. 33

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA PANIC HARDWARE 99EO LENTH AS REQ 626 VON

1 EA STAND-ALONE TRIM EXG7 EV 15 MS VD9

(MAGNETIC STRIPE ONLY FEATURE) 626 BES

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

CARDS FOR ACCESS CONTROL CARD READERS SHALL OPERATE STAND-ALONE TRIM.

SECTION 08 71 00 Page 19

Set No. 34

Not Used

Set No. 35

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA ELECTRIC HINGE 5BB1HW 4.5 X 4.5 TW8 630 IVE

1 EA PANIC HARDWARE 98EO LENGTH AS REQ 630 VON

1 EA ALARM KIT 98-ALK RX X SS PUSH BAR TRIM

LENGTH AS REQ (HARDWIRED) 628 VON

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA MORTISE CYLINDER SFIC HOUSING X TP AS REQ

WITH KEYED CONST. CORE 626 SCH

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

THE CYLINDER IN THE EXIT DEVICE WILL DISARM THE EXIT DEVICE ALARM.

Set No. 36

Provide each SGL door(s) with the following:

3 EA HINGE BY SOUND DOOR & FRAME MANUFACTURER

1 EA ELEC. POWER TRANSFER EPT-5 626 PHI

1 EA COMBINATION LOCK LKM7000-X-09 (STRIKE AS REQ) 626 MAS

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA OVERHEAD STOP 900S SERIES X SIZE & BRKT AS REQ 630 GLY

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS BY SOUND DOOR & FRAME MANUFACTURER

1 EA DOOR BOTTOM BY SOUND DOOR & FRAME MANUFACTURER

1 EA THRESHOLD BY SOUND DOOR & FRAME MANUFACTURER

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 37

Provide each SGL door(s) with the following:

3 EA HINGE BY SOUND DOOR & FRAME MANUFACTURER

1 EA ELEC. POWER TRANSFER EPT-5 626 PHI

1 EA COMBINATION LOCK LKM7000-X-09 (STRIKE AS REQ) 626 MAS

1 EA SURFACE CLOSER P4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

SECTION 08 71 00 Page 20

1 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS BY SOUND DOOR & FRAME MANUFACTURER

1 EA DOOR BOTTOM BY SOUND DOOR & FRAME MANUFACTURER

1 EA THRESHOLD BY SOUND DOOR & FRAME MANUFACTURER

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 38

Provide each SGL door(s) with the following:

3 EA HINGE BY SOUND DOOR & FRAME MANUFACTURER

1 EA ELEC. POWER TRANSFER EPT-5 626 PHI

1 EA COMBINATION LOCK LKM7000-X-09 (STRIKE AS REQ) 626 MAS

1 EA SURFACE CLOSER 4040XP MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 EA WALL STOP WS407CCV 630 IVE

1 SET SEALS BY SOUND DOOR & FRAME MANUFACTURER

1 EA DOOR BOTTOM BY SOUND DOOR & FRAME MANUFACTURER

1 EA THRESHOLD BY SOUND DOOR & FRAME MANUFACTURER

1 EA POWER SUPPLY PS902 SCE

1 EA BALANCED MAGNETIC SWITCH BY ACCESS CONTROL

1 CARD READER BY ACCESS CONTROL

1 POWER SUPPLY FOR CARD READER BY ACCESS CONTROL (IF REQUIRED)

Set No. 39

Provide each SGL door(s) with the following:

3 EA HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA PANIC HARDWARE LD98NL LENGTH AS REQ 630 VON

1 EA RIM CYLINDER 80-159 HOUSING WITH

KEYED CONST. CORE 626 SCH

1 EA IC CORE ONLY, KEYED SFIC CORE TO MATCH

EXISTING BEST KEY SYSTEM 626 BES

1 EA SURFACE CLOSER 4040XP SCUSH MTG BRKT, SPCR

& PLATE AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE

1 SET SEALS 164V H & J AL NGP

1 EA OH RAIN DRIP 16A DOOR WIDTH + 4" CL NGP

1 EA DOOR SWEEP C627A LENGTH AS REQ CL NGP

1 EA THRESHOLD 653 LENGTH AS REQ AL NGP

-- End of Section --

SECTION 08 71 00 Page 21

SECTION 10 75 16

FLAGPOLES

05/13

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA 611 (1998; R 2004) Voluntary Specification for Anodized Architectural Aluminum

ASTM INTERNATIONAL (ASTM)

ASTM B 241/B 241M (2002) Standard Specification for Aluminum and Aluminum-Alloy Seamless Pipe and Seamless Extruded Tube

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01330 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Flagpoles; G, AE

Include plans, elevations, details, and attachments to other work. Show general arrangement, jointing, fittings, accessories, grounding, anchoring, and support.

SD-03 Product Data

Flagpoles

Include construction details, material descriptions, dimensions of individual components and profiles, operating characteristics, fittings, accessories, and finishes for flagpoles.

SD-04 Samples

Flagpoles

Submit for each type of exposed finish required, in manufacturer's standard sizes.

SD-10 Operation and Maintenance Data

Flagpoles

SECTION 10 75 16 Page 1

Submit for flagpoles to include in operation and maintenance manuals.

1.3 QUALITY ASSURANCE

Obtain flagpoles as complete units, including fittings, accessories, bases, and anchorage devices, from single source from single manufacturer.

1.4 DELIVERY, STORAGE AND HANDLING

Spiral wrap flagpoles with heavy paper and enclose in a hard fiber tube or other protective container.

PART 2 PRODUCTS

2.1 FLAGPOLES

2.1.1 Flagpole Construction

Construct flagpoles in one piece if possible. If more than one piece is necessary, comply with the following:

a. Fabricate shop and field joints without using fasteners, screw collars, or lead caulking.

b. Provide self-aligning, snug-fitting joints.

2.1.2 Exposed Height

30 feet.

2.1.3 Aluminum Flagpoles

Provide cone -tapered flagpoles fabricated from seamless extruded tubing complying with ASTM B 241/B 241M, Alloy 6063, with a minimum wall thickness of 3/16 inch.

2.1.4 Metal Foundation Tube

Manufacturer's standard corrugated-steel foundation tube, not less than

0.064 inch nominal wall thickness. Provide with 3/16 inch steel bottom plate and support plate; 3/4 inch diameter, steel ground spike; and steel centering wedges welded together. Galvanize steel after assembly. Provide loose hardwood wedges at top of foundation tube for plumbing pole.

a. Provide flashing collar of same material and finish as flagpole.

2.2 FITTINGS

2.2.1 Finial Ball

Manufacturer's standard flush-seam ball, sized as indicated or, if not indicated, to match flagpole-butt diameter.

a. 0.063-inch spun aluminum, finished to match flagpole.

SECTION 10 75 16 Page 2

2.2.2 Internal Halyard, Winch System

Manually operated winch with control stop device and removable handle, stainless-steel cable halyard, and concealed revolving truck assembly with plastic-coated counterweight and sling. Provide flush access door secured with cylinder lock. Finish truck assembly to match flagpole.

a. Halyard Flag Snaps: Provide two stainless-steel swivel snap hooks per halyard.

1. Provide with neoprene or vinyl covers.

2.3 GENERAL FINISH REQUIREMENTS

a. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.

b. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

2.4 ALUMINUM FINISH

Clear Anodic Finish: AAMA 611, AA-M12C22A41, Class I, 0.018 mm or thicker.

PART 3 EXECUTION

3.1 EXAMINATION

a. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances, including foundation; accurate placement, pattern, orientation of anchor bolts, and other conditions affecting performance of the Work.

b. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

a. Prepare uncoated metal flagpoles that are set in foundation tubes by painting below-grade portions with a heavy coat of bituminous paint.

b. Foundation Excavation: Excavate to neat clean lines in undisturbed soil. Remove loose soil and foreign matter from excavation and moisten earth before placing concrete. Place and compact drainage material at excavation bottom.

c. Provide forms where required due to unstable soil conditions and for perimeter of flagpole base at grade. Secure and brace forms to prevent displacement during concreting.

d. Place concrete, as specified in Section 03 30 00 CAST-IN-PLACE CONCRETE. Compact concrete in place by using vibrators. Moist-cure exposed concrete for not less than seven days or use nonstaining curing compound.

e. Trowel exposed concrete surfaces to a smooth, dense finish, free of

SECTION 10 75 16 Page 3 trowel marks, and uniform in texture and appearance. Provide positive slope for water runoff to perimeter of concrete base.

3.3 FLAGPOLE INSTALLATION

a. General: Install flagpoles where shown and according to Shop Drawings and manufacturer's written instructions.

b. Ground Set: Place foundation tube, center, and brace to prevent displacement during concreting. Place concrete. Plumb and level foundation tube and allow concrete to cure. Install flagpole, plumb, in foundation tube.

1. Foundation Tube: Place tube seated on bottom plate between steel centering wedges and install hardwood wedges to secure flagpole in place. Place and compact sand in foundation tube and remove hardwood wedges. Seal top of foundation tube with a 2-inch layer of elastomeric joint sealant and cover with flashing collar.

-- End of Section --