Amendment_0006_Attachment_3.pdf
PDF 171 KB Posted
- Solicitation number
- W912DS-13-R-0017
About this file
Amendment 0006 Attachment 3
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MD MD
MDMD
LV LV
1 2 3 4 5 6 6.8 7
H
H.1
J
K
L
M
N
N.8
P
P.5
H101
LOW-BAY
HANGAR
SPECIAL
TOOLS
ROOM
VESTIBULE
AVIONICS
SHOP
AVIATION
SUPPORT
FLIGHT
OPS
VESTIBULE
FE
MATCH LINE
SEE 1/EL101
MATCH LINE
SEE 1/EL101
MATCH LINE
SEE 1/EL104
MATCH LINE
SEE 1/EL105
Z
X1
X1
Z Z Z Z Z
Z
Z
Z Z
Z
Z Z Z Z Z
Z
Z
Z
Z Z
Z
Z
Z
Z Z Z Z Z Z
Z
Z
Z Z Z Z Z Z Z Z
Z
Z
Z
Z Z
Z
Z Z
Z Z
Z
Z Z Z Z Z
Z
Z
LTG3 - 10,12
LT
G
- 1
3, LT
G
- 1
7, 19 17 15 13
15 13
19 17 15 13
20 18 16 14
20 18 16 14
20 18
LTG3 - 14,16
121232527
27 25
25 23
212325
25 23 21
LTG3 - 21,23
LTG3 - 25,27
LLC4
LL
C
LLC2
LLC1
125A120B
TYPICAL
T1 T1
T1T1
T1 T1
LV
X1
TYPICAL
LTG3 - 24
PC
LTG3 - 24
PC
LTG3 - 18,20
3 16
3.42.7 5.9 7.1
8.4
WE
WE
WE
LV
LV
EL102
WE
LTG5 - 18
VIA LCP5
PC
10' AFG
LTG3 - 9,11 1
5.5 6 6.8 6.9 7
N
N.8
P
5.8 5.9 7.1
C C
C
CEC
C
LTG3 - 26
M
AY
N
YD
A
/E B
O R
D
ER
FI
LE
N
AM
E:
S ub m itt ed b y:
Pl ot
D at e:
FS
B
Te le ph on e
0-
, F ax
-7
B ro ad w ay E xt
St e
0, O kl ah om a C ity , O
K Ar ch ite ct s
En gi ne er s Pl an ne rs
A N
SI
D
U . S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il
FS
B
/0 2/
S O
L-
-B -N
U M
B
W
FY
Q
-1 0-
D -0
FY
C
ER
D
EC
F lig ht A ct iv ity F ac ilit y La ke hu rs t N
AE
S
JB
M cG ui re /D ix /L ak eh ur st
, N ew
J er se y
US Army Corps of Engineers
New York District
SHEET OF 530
S O
LI
C
IT
A
TI
O
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
S
IZ
E
S U
B M
IT
TE
D B
Y:
P
LO
T D
AT
E:
C O
N
TR
A C
T N
O
P
LO
TT
E
D B
Y:
D
ES
C
R
IP
TI
O
N M
AR
K
A
PP
R
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
D
2 3
C
4 5
A
B
SHEET
REFERENCE
NUMBER
0 1"
Fr an kf ur t S ho rt B ru za
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
GARY W.
JAMES
16166
O K L A H O M A
LI
C
EN
SE
D
PROFESS IO NA L
ENG
IN
EER
xx xx c-xx x.
dw g
C :\U se rs
\fx r\D oc um en ts
\R ev it\
2_
E le c_ fx r.r vt
6/
/2
6:
:0
P
M
6/
/2
6:
:0
P
M
EL102
LI
G
H
TI
N G
P
LA
N
AR
EA
B
JT
L
M
BK
P R
M
M
BK
SCALE: 3/32" = 1'-0"
1 LIGHTING PLAN - AREA BN
0 5'-4" 10'-8" 21'-4"
A
KEY PLAN
UPUPUP
B
D
C
E
F G
GENERAL NOTES
A. REFER TO DRAWING E-001 FOR THE LEGEND AND
ABBREVIATIONS.
B. MOUNT ALL TYPE Z LIGHT FIXTURES IN THE
HANGAR AT HEIGHT INDICATED USING AIRCRAFT
CABLE ATTACHED TO 1/4-20 EYEBOLTS LOCATED
NEAR EACH CORNER OF THE FIXTURE. SWAY
BRACE FIXTURE AT (4) EYEBOLTS USING
GRIPPLE OR AN EQUAL PRODUCT.
C. SWAY BRACE ALL OVERHEAD ELECTRICAL
EQUIPMENT TO PREVENT IT FROM MOVING WHEN
THE CEILING FAN UNITS ARE ACTIVATED.
SHEET KEYNOTES
1. THIS LIGHTING CONTROL PANEL CONTROLLING
(4) SEPARATE LIGHTING CIRCUITS USING
INTERNAL SWITCHING RELAYS. MOUNT BOTTOM
OF LIGHTING CONTROL PANEL AT 8'-0" AFF.
REFERENCE DETAIL 3 ON SHEET EL602.
2. HANGAR MANUAL LIGHTING CONTROL STATION.
SEE DETAIL 3 ON SHEET EL602.
3. FIXURES SHALL BE ENERGIZED CONTINUOUSLY,
AND SERVE AS BOTH "NIGHT LIGHT" AND
EMERGENCY EGRESS FIXTURES.
4. NOT USED.
5. NOT USED.
6. MOUNT LIGHT FIXTURE AT 41'-9" AFF.
7. MOUNT LIGHT FIXTURE AT 43'-6" AFF.
8. MOUNT LIGHT FIXTURE AT 40'-2" AFF.
9. MOUNT LIGHT FIXTURE AT 38'-6" AFF .
10. MOUNT LIGHT FIXTURE AT 36'-11" AFF.
11. MOUNT LIGHT FIXTURE AT 35'-8" AFF.
12. AVOID INSTALLING ANY ELECTRICAL EQUIPMENT
WITHIN 10'-0" OF THE HEF DISCHARGE
EQUIPMENT UNLESS THE ELECTRICAL
EQUIPMENT IS INSTALLED ABOVE THE HEF
DISCHARGE EQUIPMENT. THIS INCLUDES, BUT IS
NOT LIMITED TO, LIGHT FIXTURES, LIGHTING
CONTROL DEVICES, CONDUIT, WIRE, ETC.
(TYPICAL)
13. AVOID INSTALLING ANY ELECTRICAL EQUIPMENT
WITHIN 5'-0" OF THE OUTSIDE RADIUS OF THE
CEILING FAN. THIS INCLUDES, BUT IS NOT
LIMITED TO, LIGHT FIXTURES, LIGHTING
CONTROL DEVICES, CONDUIT, WIRE, ETC.
CONDUIT AND WIRING WHICH SERVES THE
CEILING FAN ITSELF OR PASSES COMPLETELY
OVER THE CEILING FAN'S BLADES BY 36" OR
MORE SHALL BE EXEMPTED AS LONG AS THERE
ARE NO PULL BOXES WITHIN THE CEILING FAN'S
RADIUS.(TYPICAL)
14. MOUNT LIGHT FIXTURE UNDER MECHANICAL
PLATFORM AT APPROXIMATELY 36'-9" AFF.
15. NOT USED.
16. CHAIN MOUNT AT 41'-0" AFF.
17. HOME RUN CIRCUIT TO DEDICATED 277V 20A 1
POLE NORMALLY ON CIRCUIT BREAKER IN
CENTRAL EMERGENCY LIGHTING INVERTER.
18. ALSO SEE SHEET ES103 FOR WALL-MOUNTED
LIGHTS AT 28'-6" AFF.
19. EMERGENCY BATTERY BALLAST SHALL BE
CONNECTED TO AN UNSWITCHED HOT
CONDUCTOR ON THE SAME LIGHTING CIRCUIT.
20. LOCATE SWITCH AT TOP OF THE SHIPS LADDER.
FIELD VERIFY LOCATION. SWITCH SHALL
CONTAIN A 12-HOUR TIMER, TO AUTOMATICALLY
EXTINGUISH THE MECHANICAL AREA LIGHTS IF
NOT OTHERWISE TURNED OFF.
SCALE: 3/32" = 1'-0"
2 MECHANICAL PLTFORM LIGHTING
0 5'-4" 10'-8" 21'-4"
N
TA
G A
D D
E D
, C C
T
C O
R R
EC
TE
D
/1 1/
File details come from the government source that posted it. Updated .