Amendment_0006_Attachment_9.pdf

PDF 26 KB Posted

Attached to
FY13 Flight Activity Facility, Lakehurst Naval Station, New Jersey
Solicitation number
W912DS-13-R-0017
Issued by

About this file

Amendment 0006 Attachment 9

View the file

Other files

File Type Posted
EP602.pdf PDF
EP407.pdf PDF
EP601.pdf PDF
EP411.pdf PDF
10_56_26.pdf PDF
ET105.pdf PDF
M-701.pdf PDF
ES105.pdf PDF
EP404.pdf PDF
Amendment_0007.pdf PDF
A-606.pdf PDF
41_22_13.15.pdf PDF
F-103.pdf PDF
ET601.pdf PDF
ET106.pdf PDF
ET103.pdf PDF
Amendment_0006_Attachment_6.pdf PDF
Amendment_0006_Attachment_4.pdf PDF
Amendment_0006_Attachment_2.pdf PDF
Amendment_0006_Attachment_10.pdf PDF
Amendment_0006_Attachment_3.pdf PDF
Amendment_0006_Attachment_8.pdf PDF
Amendment_0006.pdf PDF
Amendment_0006_Attachment_1.pdf PDF
Amendment_0006_Attachment_5.pdf PDF
Amendment_0006_Attachment_7.pdf PDF
Amendment_0005_Revised_Drawings.pdf PDF
Amendment_0005.pdf PDF
WBS_Fill-In.pdf PDF
Revised_drawings_-_Amendment_4.pdf PDF
Amendment_0004.pdf PDF
Specifications_-_Amendment__4.pdf PDF
Revised_Civil_Drawings_-_Amendment_3.pdf PDF
Revised_Architectural_Drawing_2_-_Amendment_3.pdf PDF
Specifications_-_Amendment_3.pdf PDF
Revised_Architectural_Drawing_1_-_Amendment_3.pdf PDF
Revised_Interior_Drawings_-_Amendment_3.pdf PDF
AMENDMENT_0003.pdf PDF
Amendment_0002.pdf PDF
Amendment_2 _Revised_Specs..pdf PDF
Amendment_2 _Drawings.pdf PDF
Drawings_1__M-306_and_M-603.pdf PDF
Amendment_0001.pdf PDF
Drawings_2___B-107_THRU_B-111.pdf PDF
Drawing_Vol_1B_.pdf PDF
00800_Exhibits.pdf PDF
Drawing_Vol_2C.pdf PDF
Spec_-_Volume_2.pdf PDF
Drawing_Vol_1A_.pdf PDF
Drawing_Vol_2A.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FY13 CERDEC FLIGHT ACTIVITY FACILITY

LAKEHURST NAES - JB MCGUIRE/DIX/LAKEHURST, NEW JERSEY JUNE 7, 2013

SECTION 10 51 13

METAL LOCKERS

05/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A653/A653M (2011) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A924/A924M (2010a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process

ASTM B 456 (2003; R 2009) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium

ASTM D 6386 (2010) Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Product and Hardware Surfaces for Painting

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FS AA-L-00486 (Rev J) Lockers, Clothing, Steel

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction

(LEED-NC)

1.2 SUSTAINABLE DESIGN REQUIREMENTS

1.2.1 Recycled Content

See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. Postconsumer recycled content plus one-half of preconsumer recycled content not less than 25 percent.

1.2.2 Local/Regional Materials

See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total local material requirements.

SECTION 10 51 13 Page 1

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Types; G, RO

Location; G, RO

Installation

Numbering system

SD-03 Product Data

Material

Locking Devices

Handles

Finish

Locker components

Assembly instructions

Recycled Content; (LEED)

Documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating cost for each product having recycled content.

Local/Regional Materials; (LEED)

Documentation indicating distance between manufacturing facility and the project site. Indicate distance of raw material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project.

Waste Management; (LEED)

Documentation indicating percentages by weight of materials and products that are recycled and/or salvaged nonhazardous construction debris.

SD-04 Samples

Color chips; G, RO

SECTION 10 51 13 Page 2

1.4 DELIVERY, HANDLING, AND STORAGE

Deliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturer's name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.

1.5 FIELD MEASUREMENTS

To ensure proper fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location

1.6 QUALITY ASSURANCE

1.6.1 Color Chips

Provide a minimum of three color chips, not less than 3 inches square, of each color indicated.

Government may request performance-characteristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486. Lockers not conforming will be rejected.

PART 2 PRODUCTS

2.1 TYPES

Locker must have the following type and size in the location and quantities indicated. Locker finish colors will be as scheduled.

2.1.1 Two Person Lockers

Two person lockers must be as follows:

1215 inches wide, 1512 inches deep, and 72 inches overall height, 52 inches opening height, without base.

2.1.2 Double-Tier ALSE Support Shop Lockers

Double-tier lockers must be as follows:

18 inches wide, 42 inches deep, and 72 inches high, without base.

Lockers shall have doors front and back for through access.

2.2 MATERIAL

2.2.1 Galvanized Steel Sheet

ASTM A653/A653M and ASTM A924/A924M, commercial quality, minimized spangle, galvanized steel sheet with not less than G60 zinc coating. Prepare surface of sheet for painting in accordance with ASTM D 6386, Method A.

Minimum uncoated sheet thickness shall be 0.064 inch (16 gage).

2.2.2 Chromium Coating

Nickel and chromium electrodeposited on the specified base metal. Conform to ASTM B 456, SC-3, as applicable to the base metal.

SECTION 10 51 13 Page 3

2.2.3 Finish

FS AA-L-00486, powder coat.

2.2.3.1 Color

As indicated in Section 09 06 90 COLOR SCHEDULE.

2.3 COMPONENTS

2.3.1 Built-In Locks

Built-in locks are not required.

2.3.2 Coat Hooks

FS AA-L-00486, chromium plated.

2.3.3 Hanger Rods

FS AA-L-00486.

2.3.4 Door Handles

FS AA-L-00486. Provide zinc alloy or steel handles with a chromium coating.

2.3.5 Doors

FS AA-L-00486, not less than 0.079 inch (14 gage) thick steel sheet, except doors to ALSE Support Shop Lockers on shop side only shall be 13 gauge expanded metal.

2.3.5.1 Hinges

In addition to the requirements of FS AA-L-00486, provide 5-knuckle hinges, minimum 2 inches high. Fabricate knuckle hinges from not less than 0.0787 inch thick steel sheet. A full height piano hinge may be provided if standard with the manufacturer. Weld or bolt hinges to the door frame.

Weld, bolt, or rivet hinges to the door.

2.3.5.2 Latching Mechanisms

FS AA-L-00486, recessed.

2.3.6 Latch Strikes

FS AA-L-00486. Fabricate from not less than 0.0787 inch thick steel sheet, except latch strike may be continuous from top to bottom and fabricated as part of the door framing.

2.3.7 Door Ventilation

Provide manufacturer's standard louvers in solid steel locker doors v, except omit louvers at doors on Cooridor 004 side of ALSE Support Shop lockers.

2.3.8 Silencers

FS AA-L-00486.

SECTION 10 51 13 Page 4

2.3.9 Back and Side Panels, Tops, and Bottoms

FS AA-L-00486, not less than 0.052 inch (18 gage) thick steel sheet.

2.3.10 Sloping Locker Tops

Provide sloping locker tops in addition to the locker-section flat tops.

Sloping tops must be continuous in length. Provide fillers or closures at the exposed end of sloping tops. Fabricate sloping tops from not less than 0.0478-inch thick steel sheet.

2.3.11 Shelves

FS AA-L-00486. Fabricate from not less than 0.064 inch (16 gage) thick steel sheet.

2.3.12 Number Plates

FS AA-L-00486. Aluminum . Provide consecutive numbers.

2.3.13 Fastening Devices

Provide bolts, nuts, and rivets as specified in FS AA-L-00486.

2.4 BENCHES

a. Bench tops shall be made of butcher block, maple hardwood 1-1/4 inches thick and width as shown on drawings. Apply double coat of satin-gloss sealer for protection.

b. Pedestals: Manufacturer's standard brushed 16 gage stainless steel pedestal. The pedestal shall be secured to the floor with concrete anchors. Overall pedestal height shall be 16 inches.

PART 3 EXECUTION

3.1 ASSEMBLY AND INSTALLATION

Assemble lockers according to the locker manufacturer's instructions.

Align lockers horizontally and vertically. Secure lockers to wall and base with screws as indicated. Bolt adjacent lockers together. Adjust doors to operate freely without sticking or binding and to ensure they close tightly.

3.2 NUMBERING SYSTEM

Install number plates on lockers consecutively as indicated .

3.3 FIELD QUALITY CONTROL

3.3.1 Testing

Government may request performance-characteristic tests on assembled lockers in accordance with FS AA-L-00486. Lockers not conforming will be rejected.

3.3.2 Repairing

Remove and replace damaged and unacceptable portions of completed work with

SECTION 10 51 13 Page 5 new.

3.3.3 Cleaning

Clean surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner. Remove equipment, surplus materials, and rubbish from the site.

3.4 WASTE MANAGEMENT

Disposal and recycling of waste materials, including corrugated cardboard recycling, shall be in accordance with the Waste Management Plan specified in Section 01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT. Identify manufacturer's policy for collection or return of construction scrap and unused material and packaging material. Institute construction waste separation and recycling to take advantage of manufacturer's programs.

When such a service is not available, seek local recyclers to reclaim the materials.

-- End of Section --

SECTION 10 51 13 Page 6

File details come from the government source that posted it. Updated .